978 resultados para Dental Amalgam
Resumo:
The aim of this study was to evaluate the degree of conversion and hardness of a dental composite resin Filtek (TM) Z-350 (3M ESPE, Dental Products St. Paul, MN) photo-activated for 20 s of irradiation time with two different light guide tips, metal and polymer, coupled on blue LED Ultraled LCU (Dabi Atlante, SP, Brazil). With the metal light tip, power density was of 352 and with the polymer was of 456 mW/cm(2), respectively. Five samples (4 mm in diameter and 2mm in thickness-ISO 4049), were made for each Group evaluated. The measurements for DC (%) were made in a Nexus-470 FT-IR, Thermo Nicolet, E.U.A. Spectroscopy (FTIR). Spectra for both uncured and cured samples were analyzed using an accessory of reflectance diffuse. The measurements were recorded in absorbance operating under the following conditions: 32 scans, 4 cm(-1) resolution, 300-4000 cm(-1) wavelength. The percentage of unreacted carbon double bonds (% C=C) was determined from the ratio of absorbance intensities of aliphatic C=C (peak at 1637 cm(-1)) against internal standard before and after curing of the sample: aromatic C-C (peak at 1610 cm(-1)). The Vickers hardness measurements (top and bottom surfaces) were performed in a universal testing machine (Buehler MMT-3 digital microhardness tester Lake Bluff, Illinois USA). A 50 gf load was used and the indenter with a dwell time of 30 s. The data were submitted to the test t Student at significance level of 5%. The mean values of degree of conversion for the polymer and metal light guide tip no were statistically different (p = 0.8389). The hardness mean values were no statistically significant different among the light guide tips (p = 0.6244), however, there was difference between top and bottom surfaces (p < 0.001). The results show that so much the polymer light tip as the metal light tip can be used for the photo-activation, probably for the low quality of the light guide tip metal.
Resumo:
Dental composite resins possess good esthetic properties, and are currently among the most popular dental restorative materials. Both organic and inorganic phases might influence the material behavior, the filler particle features and rate are the most important factors related to improvement of the mechanical properties of resin composites. Thus, the objective of this study was to evaluate the effect of three different composite resins on the polymerization process by Vickers hardness test. The samples were prepared using three different composite resins, as follow: group I-P-60 (3M/ESPE); group II-Herculite XRV (Kerr), and group III-Durafill (Heraeus-Kulzer). The samples were made in a polytetrafluoroethylene mould, with a rectangular cavity measuring 7 mm in length, 4 mm in width, and 3 mm in thickness. The samples were photo-activated by one light-curing unit based on blue LEDs (Ultrablue III-DMC/Brazil) for 20 and 40 s of irradiation times. The Vickers hardness test was performed 24 h after the photo-activation until the standardized depth of 3 mm. The Vickers hardness mean values varied from 158.9 (+/- 0.81) to 81.4 (+/- 1.94) for P-60, from 138.7 (+/- 0.37) to 61.7 (+/- 0.24) for Herculite XRV, and from 107. 5 (+/- 0.81) to 44.5 (+/- 1.36) for Durafill composite resins photo-activated during 20 s for the 1st and 2nd mm, respectively. During 40 s of photo-activation, the Vickers hardness mean values were: from 181.0 (+/- 0.70) to 15.6 (+/- 0.29) for P-60, and from 161.8 (+/- 0.41) to 11.2 (+/- 0.17) for Herculite XRV composite resins, for the 1st and 3th mm, respectively. For Durafill composite resin the mean values varied from 120.1 (+/- 0.66) to 61.7 (+/- 0.20), for the 1st and 2nd mm, respectively. The variation coefficient (CV) was in the most of the groups lower than 1%, then the descriptive statistic analysis was used. The Vickers hardness mean values for Durafill were lower than P-60 and Herculite XRV composite resins for 20 and 40 s of irradiation time. The polymerization process was greatly affected by the composition of the composite resins.
A robust Bayesian approach to null intercept measurement error model with application to dental data
Resumo:
Measurement error models often arise in epidemiological and clinical research. Usually, in this set up it is assumed that the latent variable has a normal distribution. However, the normality assumption may not be always correct. Skew-normal/independent distribution is a class of asymmetric thick-tailed distributions which includes the Skew-normal distribution as a special case. In this paper, we explore the use of skew-normal/independent distribution as a robust alternative to null intercept measurement error model under a Bayesian paradigm. We assume that the random errors and the unobserved value of the covariate (latent variable) follows jointly a skew-normal/independent distribution, providing an appealing robust alternative to the routine use of symmetric normal distribution in this type of model. Specific distributions examined include univariate and multivariate versions of the skew-normal distribution, the skew-t distributions, the skew-slash distributions and the skew contaminated normal distributions. The methods developed is illustrated using a real data set from a dental clinical trial. (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Dental composites can be improved by heat treatment, as a possible way to increase mechanical properties due to additional cure (post-cure). Direct dental composites are essentially similar to the indirect ones, supposing they have the same indication. Therefore, to establish a heat treatment protocol for direct composites, using as indirect (photoactivated by continuous and pulse-delay techniques), a characterization (TG/DTG and DSC) is necessary to determine parameters, such as mass loss by thermal decomposition, heat of reaction and glass transition temperature (T (g)). By the results of this study, a heat treatment could be carried out above 160 A degrees C (above T (g), and even higher than the endset exothermic event) and under 180 A degrees C (temperature of significant initial mass loss).
Resumo:
Lead (Pb) poisoning is preventable but continues to be a public health problem in several countries. Measuring Pb in the surface dental enamel (SDE) using microbiopsies is a rapid, safe, and painless procedure. There are different protocols to perform these microbiopsies, but the reliability of dental enamel lead levels (DELL) determination is dependent upon biopsy depth (BD). It is established that DELL decrease from the outermost superficial layer to the inner layer of dental enamel. The aim of this study was to determine DELL obtained by two different microbiopsy techniques on SDE termed protocol I and protocol II. Two consecutive enamel layers were removed from the same subject group (n = 138) for both protocols. Protocol I consisted of a biopsied site with a diameter of 4 mm after the application of 10 l HCl for 35 s. Protocol II involved a biopsied site of 1.6 mm diameter after application of 5 l HCl for 20 s. The results demonstrated that there were no significant differences for BD and DELL between homologous teeth using protocol I. However, there was a significant difference between DELL in the first and second layers using both protocols. Further, the BD in protocol II overestimated DELL values. In conclusion, SDE analyzed by microbiopsy is a reliable biomarker in protocol I, but the chemical method to calculate BD in protocol II appeared to be inadequate for measurement of DELL. Thus, DELL could not be compared among studies that used different methodologies for SDE microbiopsies.
Resumo:
Purpose: The aim of this in situ double-blind randomised crossover study was to investigate the effect of calcium (Ca) pre-rinse on the composition of plaque and on enamel prior to the use of fluoride (F) dentifrice. Materials and Methods: During four phases (14 days each) of this study, 10 volunteers had agreed to wear dental appliances containing two healthy bovine enamel blocks. A fresh solution containing 20% weight/volume (w/v) sucrose was dripped on the enamel blocks ex vivo for 5 min three times a day. Subsequently, the appliances were replaced in the mouth, and the volunteers rinsed their mouth with 10 mL of a Ca (150 mmol/L) or a placebo rinse (1 min). In sequence, a slurry (1:3 w/v) of F (1030 ppm) or placebo dentifrice was dripped onto the blocks ex vivo for 1 min. During this time, the volunteers brushed their teeth with the respective dentifrice. The appliances were replaced in the mouth, and the volunteers rinsed their mouth with water. The plaque formed on the blocks was analysed for F and Ca. The enamel demineralisation as well as the incorporation of F on enamel was evaluated by cross-sectional microhardness and alkali-soluble F analysis, respectively. Data were tested using analysis of variance (P < 0.05). Results: The Ca pre-rinse prior to the use of the F dentifrice led to a three- and sixfold increase in the plaque F and Ca concentrations, respectively. It also did not have any additive effect on the F content on the enamel and the demineralisation of the enamel, in comparison with the use of F dentifrice alone. Conclusions: A Ca lactate rinse used prior to the F dentifrice was able to change the mineral content in the plaque, but it was unable to prevent enamel demineralisation.
Resumo:
Different compositions of visible-light-curable triethylene glycol dimethacrylate/bisglycidyl methacrylate copolymers used in dental resin formulations were prepared through copolymerization photoinitiated by a camphorquinone/ethyl 4-dimethylaminobenzoate system irradiated with an Ultrablue IS light-emitting diode. The obtained copolymers were evaluated with differential scanning calorimetry. From the data for the heat of polymerization, before and after light exposure, obtained from exothermic differential scanning calorimetry curves, the light polymerization efficiency or degree of conversion of double bonds was calculated. The glass-transition temperature also was determined before and after photopolymerization. After the photopolymerization, the glass-transi-tion temperature was not well defined because of the breadth of the transition region associated with the properties of the photocured dimethacrylate. The glass-transition temperature after photopolymerization was determined experimentally and compared with the values determined with the Fox equation. In all mixtures, the experimental value was lower than the calculated value. Scanning electron microscopy was used to analyze the morphological differences in the prepared copolymer structures. (C) 2007 Wiley Periodicals, Inc.
Resumo:
The aim of this work was to evaluate the effect of the storage time on the thermal properties of triethylene glycol dimethacrylate/2,2-bis[4-(2-hydroxy-3-methacryloxy-prop-1-oxy)-phenyl]propane bisphenyl-alpha-glycidyl ether dimethacrylate (TB) copolymers used in formulations of dental resins after photopolymerization. The TB copolymers were prepared by photopolymerization with an Ultrablue IS light-emitting diode, stored in the dark for 160 days at 37 degrees C, and characterized with differential scanning calorimetry (DSC), dynamic mechanical analysis (DMA), and Fourier transform infrared spectroscopy with attenuated total reflection. DSC curves indicated the presence of an exothermic peak, confirming that the reaction was not completed during the photopolymerization process. This exothermic peak became smaller as a function of the storage time and was shifted at higher temperatures. In DMA studies, a plot of the loss tangent versus the temperature initially showed the presence of two well-defined peaks. The presence of both peaks confirmed the presence of residual monomers that were not converted during the photopolymerization process. (C) 2009 Wiley Periodicals, Inc. J Appl Polym Sci 112: 679-684, 2009
Resumo:
Este trabalho apresenta o desenvolvimento de um sistema de medição para a análise biomecânica da força desenvolvida durante a escovação dental, com aquisição e processamento de dados de dinamometria para a análise da escovação dental como um processo eficaz de higiene bucal. Foi desenvolvida uma célula de carga com extensômetros de resistência elétrica, montada em uma escova dental. A célula de carga foi construída com 2 Strain Gages montados em meia ponte de Wheatstone, medindo força em flexão, e 4 Strain Gages montados em ponte completa de Wheatstone medindo força de torque. A aquisição dos dados e análise foi feita através do software SAD2. Foram selecionados 6 indivíduos, dois do sexo masculino e 4 do sexo feminino, todos destros, e instruídos a escovarem os dentes por 1 minuto. Os valores medidos para a força de flexão média variam de 24gf à 526gf e para o esforço de torque médio de –76gfmm à 1890gfmm. A célula de carga desenvolvida mostrou-se repetitiva, com boa sensibilidade e confiável com um erro em flexão de 2,7% e 5,5% em torque. A célula de carga apresentou resultados semelhantes a de outros trabalhos publicados anteriormente, sendo estes válidos para uma análise quantitativa inicial no processo de escovação.
Resumo:
Ao se estudar as consequências sobre o bem-estar social de um mercado relevante onde há elevada concentração na produção, deve-se identificar, primeiramente, se a competição potencial existe. Uma forma de detecta-la seria através do exame das barreiras à entrada da concorrência no mercado relevante em estudo. O objetivo deste artigo é avaliar, no setor brasileiro de creme dental, as barreiras para firmas: entrarem ou; aumentarem sua participação de mercado. A motivação para este estudo decorre da mudança na estrutura deste mercado relevante, uma vez que, em janeiro de 1995, a Colgate, empresa com a segunda maior fatia do mercado nacional, adquiriu a Kolynos, firma detentora de metade do faturamento brasileiro deste setor.
Resumo:
O estudo das estruturas da placas maxilo-dentárias dos rincossauros Hyperodapedon Huxley, 1859, do Triássico da Formação Santa Maria, em nova abordagem histológica e ontogênica resultou na identificação da natureza do esmalte aprismático verdadeiro, de variados elementos histológicos dentinários e osteológicos, e de um centro de ossificação periosteal primário. Também foram encontradas evidências histológicas dos mecanismos de fusionamento maxilo-dentinário e amelo-maxilar. Com estes elementos, inferimos os modelos de organogênese dental, da ontogênese maxilar e dos mecanismos de fusionamento maxilodental. Encontrou-se uma singular e raríssima coroa dental, imatura e ainda não erupcionada, na região posterior da placa dental e assim evidenciou-se a correta posição da margem odontogenicamente ativa. Adicionalmente inferiu-se a localização da posição da lâmina dentária embrionária. Constatou-se a não formação de alvéolos dentários, de cemento radicular e do espaço necessário à formação do ligamento periodontal e, assim, se deduziu a não formação do folículo dental embriônico. As presenças de especiais elementos anatômicos e histológicos nos tecidos ósseos periapicais evidenciam o crescimento radicular contínuo, enquanto a forma e o fusionamento radicular imediato depõe a favor de uma função dentária fisiológica diferenciada para as baterias dentárias maxilares dos Rincossauros do gênero Hyperodapedon. Os mecanismos que possibilitaram o controle embriônico para a deposição das lamelas de tecido ósseo coronal e seu preciso fusionamento sobre o esmalte dentário, declinam por modificações nas funções tardias do órgão reduzido do esmalte e pela presença de uma membrana oral com funções osteogênicas e também protetivas, situada nas porções posteriores da placa maxilo-dentária em desenvolvimento. Mudanças heterocrônicas no tempo de diferenciação das células da crista neural embriônica e em seus derivados, como a lâmina dentária e órgãos dentários embrionários ou correlacionadas com a organogênese das placas maxilo-dentárias e seus anexos periodontais, todos como condições plesiomórficas para Diápsidas Triássicos, poderiam ser as causas responsáveis pela origem e evolução deste estranho aparelho estomatognático nos clados de Hyperodapedon sp..
Resumo:
Não há concordância em relação ao número total e intervalo entre as aplicações do verniz de clorexidina (CLX) a 1%. Além disso, os resultados quanto ao período de redução dos níveis de estreptococos do grupo mutans (EGM) na saliva ou biofilme dental são controversos. O objetivo do presente trabalho foi avaliar, através de um estudo clínico randomizado e controlado, o efeito de diferentes posologias do verniz de CLX a 1% nos níveis de EGM. Pacientes com níveis de EGM ≥ 105 UFC/ml saliva, 11-16 anos, foram distribuídos em 4 grupos: grupo A (n=14): 1 aplicação do verniz de CLX; grupo B (n=14): 1 aplicação diária do verniz CLX, em 3 dias consecutivos; grupo C (n=15): 3 aplicações do verniz CLX com intervalo de 4 dias entre cada aplicação; grupo D (n=12): 1 aplicação diária do verniz placebo, em 3 dias consecutivos. Amostras de saliva e biofilme dental foram coletadas no início do estudo e 1, 4 e 8 semanas após o término das aplicações e foram cultivadas para avaliação dos níveis de EGM e bactérias totais. Os dados foram avaliados através do teste ANOVA (medidas repetidas) e teste de Tukey. Após 1 semana, observou-se uma leve redução nos níveis salivares de EGM nos grupos A, B e C (-0,70; -0,90; -0,41 log10 UFC/ml saliva; respectivamente), significativa somente nos grupos A e B (p < 0,05). Não foram observadas diferenças nos níveis salivares de EGM entre os grupos experimentais nos diferentes períodos do experimento. No biofilme dental, 1 semana após o término do tratamento, foi observado um aumento significativo nos níveis de bactérias totais em todos os grupos experimentais e uma redução significativa nos níveis de EGM apenas no grupo A. O verniz de CLX a 1% resultou em uma leve e curta redução nos níveis de EGM. Este estudo demonstrou que repetidas aplicações do verniz de clorexidina a 1% não aumentam o seu efeito na redução dos níveis de EGM.
Resumo:
Nowadays, composite resins are the direct restorative materials more important in dental clinical performance, due to their versatility and aesthetic excellence. Bis-GMA (2,2-bis[4(2-hydroxy-3-metacryloxypropoxy)phenil]propane) is the base monomer more frequently used in restorative composite resins. However, this monomer presents some disadvantages, such as high viscosity and two aromatic rings in its structure that can promote allergic reactions to the humans. In this work, the main purpose was to synthesize new monomers from glycidyl methacrylate to use in dental restorative materials. Structural characterization of the monomers was carried out through FTIR and NMR 1H, and eight composites were produced from the new monomers, by addition of silane-treated alumino silicate particles (inorganic filler) and a photocuring system (camphorquinone and ethyl 4-dimethylaminebenzoate). The composites were analyzed by environmental scanning electronic microscopy and the water sorption and solubility, compressive strength and elastic modulus were determined. A commercial composite resin [Z100 (3M)] was used to comparison effect. The new composites presented general characteristics similar to the commercial ones; however, they didn t present the properties expected. This behavior was attributed to the lower degree of monomer reaction and to the granulometry and size distribution of the mineral filler in the polymeric matrix