708 resultados para DBD lamp


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Elétrica - FEIS

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The present work describes the photoelectrochemical hydrogen generation during a photodegradation of an organic compound. For this, it was chosen the reactive black 5 dye as a model of organic pollutant and its oxidation under TiO2 nanotube in a two compartment cell. The photoelectrocatalysis is conducted in 0.1 mol L-1 Na2SO4 pH 6 medium under photoanode biased at +1.0 V (SCE) and activated by UV and visible light using 150W Xe-Arc lamp (Oriel) and 125 W Hg lamp (Osram). The concomitant hydrogen production was monitored at cathodic compartment using a Pt cathode. Using optimized condition of Na2SO4 0.1 mol L-1 pH 6 as supporting electrolyte, applied potential of +1.0V it was verified 100% of discoloration and 72% of TOC removal of 1.0 x 10(-5) mol L-1 Reactive Black 5 dye after 120 min of treatment (rate constant of 10.6 x10(-2) min(-1)). The concomitant hydrogen generation was 44% in this condition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Improved methods for the detection of Histoplasma capsulatum are needed in regions with limited resources in which the organism is endemic, where delayed diagnosis of progressive disseminated histoplasmosis (PDH) results in high mortality rates. We have investigated the use of a loop-mediated isothermal amplification (LAMP) assay to facilitate rapid inexpensive molecular diagnosis of this disease. Primers for LAMP were designed to amplify the Hcp100 locus of H. capsulatum. The sensitivity and limit of detection were evaluated using DNA extracted from 91 clinical isolates of known geographic subspecies, while the assay specificity was determined using DNA extracted from 50 other fungi and Mycobacterium tuberculosis. Urine specimens (n = 6) collected from HIV-positive individuals with culture- and antigen-proven histoplasmosis were evaluated using the LAMP assay. Specimens from healthy persons (n = 10) without evidence of histoplasmosis were used as assay controls. The Hcp100 LAMP assay was 100% sensitive and specific when tested with DNA extracted from culture isolates. The median limit of detection was <= 6 genomes (range, 1 to 300 genomes) for all except one geographic subspecies. The LAMP assay detected Hcp100 in 67% of antigen-positive urine specimens (4/6 specimens), and results were negative for Hcp100 in all healthy control urine specimens. We have shown that the Hcp100 LAMP assay is a rapid affordable assay that can be used to expedite culture confirmation of H. capsulatum in regions in which PDH is endemic. Further, our results indicate proof of the concept that the assay can be used to detect Histoplasma DNA in urine. Further evaluation of this assay using body fluid samples from a larger patient population is warranted.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Monitoring non-ionizing radiant energy is increasingly demanded for many applications such as automobile, biomedical and security system. Thermal type infrared (IR) sensors can operate at room temperature and pyroelectric materials have high sensitivity and accuracy for that application. Working as thermal transducer pyroelectric sensor converts the non-quantified thermal flux into the output measurable quantity of electrical charge, voltage or current. In the present study the composite made of poly(vinylidene fluoride) -PVDF and lead zirconate titanate (PZT) partially recovered with polyaniline (PAni) conductor polymer has been used as sensor element. The pyroelectric coefficient p(T) was obtained by measuring the pyroelectric reversible current, i.e., measuring the thermally stimulated depolarization current (TSDC) after removing all irreversible contribution to the current such as injected charge during polarization of the sample. To analyze the sensing property of the pyroelectric material, the sensor is irradiated by a high power light source (halogen lamp of 250 W) that is chopped providing a modulated radiation. A device assembled in the laboratory is used to change the light intensity sensor, an aluminum strip having openings with diameters ranging from 1 to 10 mm incremented by one millimeter. The sensor element is assembled between two electrodes while its frontal surface is painted black ink to maximize the light absorption. The signal from the sensor is measured by a Lock-In amplifier model SR530 -Stanford Research Systems. The behavior of the output voltage for an input power at several frequencies for PZT-PAni/PVDF (30/ 70 vol%) composite follows the inverse power law (1/ f) and the linearity can be observed in the frequency range used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The food dye tartrazine (CI 19140) was exposed to UV irradiation from an artificial source, a mercury vapor lamp, and a natural one, sunlight. It was observed that conditions such as energy dose, irradiation time, pH and initial dye concentration affected its discoloration. There was 100% of color removal, after 30 min of irradiation, when a dye solution 1 x 10(-5) mol L-1 was submitted to an energy dose of 37.8 J cm(-2). Liquid Chromatography coupled to Diode Array Detection and Mass Spectrometry confirmed the cleavage of the chromophore group and the formation of five by-products at low concentration. Although by-products were formed, the Salmonella/microsome mutagenicity assay performed for both, the dye solution at a dose of 5.34 mg/plate and the solutions obtained after exposure to UV irradiation, did not present mutagenic activity for TA98 and TA100 with and without S9. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work we report the surface modification of different engineering polymers, such as, polyethylene terephthalate (PET), polyethylene (PE) and polypropylene (PP) by an atmospheric pressure plasma jet (APPJ). It was operated with Ar gas using 10 kV, 37 kHz, sine wave as an excitation source. The aim of this study is to determine the optimal treatment conditions and also to compare the polymer surface modification induced by plasma jet with the one obtained by another atmospheric pressure plasma source the dielectric barrier discharge (DBD). The samples were exposed to the plasma jet effluent using a scanning procedure, which allowed achieving a uniform surface modification. The wettability assessments of all polymers reveal that the treatment leads to reduction of more than 40 degrees in the water contact angle (WCA). Changes in surface composition and chemical bonding were analyzed by x-ray photoelectron spectroscopy (XPS) and Fourier-Transformed Infrared spectroscopy (FTIR) that both detected incorporation of oxygen-related functional groups. Surface morphology of polymer samples was investigated by Atomic Force Microscopy (AFM) and an increase of polymer roughness after the APPJ treatment was found. The plasma-treated polymers exhibited hydrophobic recovery expressed in reduction of the O-content of the surface upon rinsing with water. This process was caused by the dissolution of low molecular weight oxidized materials (LMWOMs) formed on the surface as a result of the plasma exposure. (C) 2014 Elsevier B.V. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Plasma polymer films are very attractive for industrial applications in several sectors such as in the electronic, mechanic, biomedic, coating and others, due to its good adhesion, being insoluble in mild acids and bases and having a high crosslinking structure. This work reports the physical, structural, and surface properties of the polymer obtained from an acetylene plasma polymerization technique and treated by dielectric barrier discharge (DBD). The film was deposited in a reactor supplied by a radio-frequency power source at low pressure. After deposition, the nanofilms were treated in a DBD plasma reactor operating in air. The treatment times varied from 1 to 5 min. The analysis of molecular structure of the samples was investigated by FTIR spectroscopy, showing absorption bands in 3480, 2930, 1720, 1450 and 1380 cm(-1). The water contact-angle was investigated by goniometric technique and presented values from 5 to 65 degrees. The aging effect of these films was also studied. The alteration in the films surface morphology was assessed by an atomic force microscopy (AFM) which indicated that the roughness increased from 60 nm to 160 nm as a result of the DBD treatment. The refractive index of the samples presented values near 1.7, measured by UV-Visible spectroscopy. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

With the imposition of the suspension of production and subsequent banning of incandescent light bulbs will be necessary to replace it by other more energy-efficient. Although the main alternative is the compact fluorescent lamp, the environmental impact caused by it due to incorrect disposal and the amount of harmonics included in the network resulting in losses related to the quality of electric power system makes them sought new alternatives for lighting systems that are efficient and have low environmental impact. In this context, the LED (Lighting Emitting Diode), based on solid-state components, is presented as an option for new projects and replacement of existing lighting. In this work we studied aspects of energy, environmental and economic impacts of a possible replacement of conventional lighting systems for new technology. From laboratory tests and surveys of the costs of different types of lamps used for residential lighting, we performed a comparative analysis considering energy and economic aspects which showed that the LED technology, but has a high initial investment, it is best when power quality and environmental preservation are relevant factors in decision making for the choice of technology to be used in the lighting system

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Energy efficiency is an increasingly important issue due to the current scenario where increasing demand is growing faster than the energy supplied. It is important, therefore, analyze and minimize electrical system losses. This study conducts a comparison of a system formed by a photovoltaic generator feeding an LED lamp directly without steps DC-AC -DC conversion, and a system using these conversion steps for the same lamp power. Losses in conversion steps are quantified and the degradation of power quality occurred due to conversion is evaluated

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work deals with the development of a switched-mode power supply circuit based on a Buck topology converter with a Boost Rectifier One-Cycle Control with Power Factor Correction developing, thus, a source of direct current for a module of 50 power LEDs that will be used in a lamp for public street lightning. It is presented, at first, some aspects about the most common technologies used in lamps of public street lightning in Brazil and a comparison with the White LED high power, which is the one that presents itself as the most promising among the existing market. Then it is presented the detailed development of the static converter switched PWM, consisting of a Boost rectifier with power factor correction and methodology of control One-Cycle Control associated with a Buck converter controlled by a PI method that operates as a direct current source . At the end of the simulation results of the circuit through the PSIM software are presented to verify the design behavior

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)