984 resultados para Counting, light microscope


Relevância:

30.00% 30.00%

Publicador:

Resumo:

A proof-of-concept study was reported on analysis of antigen–antibody recognition based on resonant Rayleigh scattering response of single Au nanoparticles in an imaging chamber. As benefited by a traditional dark-field microscope and a spectrograph, individual Au nanoparticles (30 nm) were observed with high signal-to-noise ratio and they were effectively utilized to monitor changes in refractive index induced by specific binding of the adsorbates. Using PSA antigen as a model, a LSPR ?max shift of about 2.85 nm was recorded for a molecular binding corresponding to 0.1 pg ml-1 of the protein biomarker. This result successfully demonstrates a non-labeling detection system for proteins as well as thousands of different chemical or biological species, and it possesses a great potential as a sensitive, on-chip and multiplexing detection.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A proof-of-concept study was reported on analysis of antigen-antibody recognition based on resonant Rayleigh scattering response of single Au nanoparticles on a microimaging chamber. As benefited by a traditional dark-field microscope and a spectrograph, tiny 30 nm Au nanoparticles were effectively used as nanosensors to monitor changes in refractive index induced by every single binding of the adsorbates. The individual Au nanoparticles were observed with very high signal-to-noise ratio, and a LSPR ?max shift of about 2.5 nm accounting for the detection of PSA antigen with concentration as low as 0.1 pg ml-1 was recorded. This resulted in the successful demonstration of a non-labelling detection system for proteins as well as thousands of different chemical or biological species with possibility of miniaturization and multiplexing scheme.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The spectroscopic capability of the photon scanning tunneling microscope is exploited to study directly the launch and propagation of surface plasmons on thin silver films. Two input beams, of different wavelength, are incident through the prism in a prism-Ag film-air-fibre tip system. Both excite surface plasmons at the Ag-air interface and light of both wavelengths is coupled into the fibre probe via the respective surface plasmon evanescent fields. One laser beam is used for instrument control. The second, or probe beam is tightly focused on the sample, within the area of the unfocused or control beam, giving a well-defined and symmetrical, confined surface plasmon launch site. However, the image at the probe wavelength is highly asymmetrical in section with an exponential tail extending beyond one side of the launch site. This demonstrates in a very direct fashion;the propagation of surface plasmons; a propagation length of similar to 11.7 mu m is measured at a probe wavelength of 543.5 nm. On rough Ag films the excitation of localised scattering centres is also observed in addition to the launch of delocalised surface plasmons.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Visible light is emitted from the Au-air interface of Al-I-Au thin-film tunnel junctions (deposited over a thin layer of CaF2 on glass) as a result of the decay of surface plasmon polaritons (SPPs). We show the surface topography of such a Au film and relate its large-scale features to the outcoupling of fast SPP's to photons. The absence of short-scale roughness features is explained by thier disappearance through surface diffusion. To confirm this a controlled sequence of 5-nm, 20-ms scanning tunneling microscope (STM) W tip crashes has been used to produce indentations 3 nm deep with a lateral dimension of 5-7 nm on a Au crystal in air at room temperature. Four sequences of indentations were drawn in the form of a square box. Right from the start, feature decay is observed and over a period of 2 h a succession of images shows that the structure disappears into the background as a result of surface diffusion. The surface diffusion constant is estimated to be 10(-18) cm2 s-1. The lack of light output via slow mode SPPs is an inevitable consequence of surface annealing.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pathogens in seeds imply quarantine constraints for exportation. This research aimed to quantify nematodes and fungus populations in seed samples of forage grasses from the main Brazilian producing states, and to multiply the nematodes in vitro, as well to study the taxonomy of the nematodes detected. Seed samples of 237 lots of different forage grasses from São Paulo, Minas Gerais, Mato Grosso do Sul, Mato Grosso, Bahia, and Goias States were collected and shipped for analyses in the Nematology and Plant Pathology Laboratories at FCAV[long dash]UNESP [long dash] Jaboticabal( SP) by Comercio e Industria Matsuda Imp., Exp. Ltd. Nematodes were extracted from 10 g of seeds. To detect the fungus, the Blotter-test was applied. The identifications were done by using a photonic microscope and a stereomicroscope. For the study of in vitro multiplication of the nematodes, the following parthenogenetic species were selected: Aphelenchoides sexlineatus, Aphelenchus sp. and Ditylenchus montanus. Cultures of the fungi Fusarium sp. and Didymella brioniae were used as substrate to multiply the nematodes in Petri dishes. Each plate was inoculated with 10 mature females, then incubated in B.O.D. at 25 [plus or minus]1 [degree]C, in the dark. Thirty days after inoculation, the nematodes were extracted. The populations obtained in the suspensions were estimated in the microscope using Peters counting chamber, and the reproduction factor estimated. For the taxonomic study of the nematodes, morphological characters of specimens were recorded under the light and scanning electron microscopes. The results indicated a large distribution of nematodes and fungus in seeds of forage grasses in Brazil. The nematodes identified in the present study were: Aphelenchoides besseyi, A. bicaudatus, A. fragariae, A. sexlineatus, Ditylenchus myceliophagus, D. dipsaci, D. montanus, and Aphelenchus sp. In addition, species of the fungi Fusarium, Helminthosporium and Phoma were recovered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the subcutaneous response of rat connective tissue to light-cure MTA and Angelus MTA. These materials were placed in polyethylene and dentin tubes and implanted into dorsal connective tissue of Wistar rats for 30 and 60 days. The specimens were prepared to be stained with hematoxylin-eosin, Von Kossa, and without stain for polarized light and evaluated in an optic microscope. The Angelus MTA showed a mild inflammatory response at 30 days and none at 60 days, characterized by organized connective tissue, presence of some chronic inflammatory cells, and induction of mineralized tissue formation. Light-cure MTA presented a moderate chronic inflammatory response at 30 days that decreased at 60 days but was more intense than with Angelus MTA and without dystrophic calcifications. It was possible to conclude that light-cure MTA was similar to MTA at 60 days, but it did not stimulate mineralization.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A sample scanning confocal optical microscope (SCOM) was designed and constructed in order to perform local measurements of fluorescence, light scattering and Raman scattering. This instrument allows to measure time resolved fluorescence, Raman scattering and light scattering from the same diffraction limited spot. Fluorescence from single molecules and light scattering from metallic nanoparticles can be studied. First, the electric field distribution in the focus of the SCOM was modelled. This enables the design of illumination modes for different purposes, such as the determination of the three-dimensional orientation of single chromophores. Second, a method for the calculation of the de-excitation rates of a chromophore was presented. This permits to compare different detection schemes and experimental geometries in order to optimize the collection of fluorescence photons. Both methods were combined to calculate the SCOM fluorescence signal of a chromophore in a general layered system. The fluorescence excitation and emission of single molecules through a thin gold film was investigated experimentally and modelled. It was demonstrated that, due to the mediation of surface plasmons, single molecule fluorescence near a thin gold film can be excited and detected with an epi-illumination scheme through the film. Single molecule fluorescence as close as 15nm to the gold film was studied in this manner. The fluorescence dynamics (fluorescence blinking and excited state lifetime) of single molecules was studied in the presence and in the absence of a nearby gold film in order to investigate the influence of the metal on the electronic transition rates. The trace-histogram and the autocorrelation methods for the analysis of single molecule fluorescence blinking were presented and compared via the analysis of Monte-Carlo simulated data. The nearby gold influences the total decay rate in agreement to theory. The gold presence produced no influence on the ISC rate from the excited state to the triplet but increased by a factor of 2 the transition rate from the triplet to the singlet ground state. The photoluminescence blinking of Zn0.42Cd0.58Se QDs on glass and ITO substrates was investigated experimentally as a function of the excitation power (P) and modelled via Monte-Carlo simulations. At low P, it was observed that the probability of a certain on- or off-time follows a negative power-law with exponent near to 1.6. As P increased, the on-time fraction reduced on both substrates whereas the off-times did not change. A weak residual memory effect between consecutive on-times and consecutive off-times was observed but not between an on-time and the adjacent off-time. All of this suggests the presence of two independent mechanisms governing the lifetimes of the on- and off-states. The simulated data showed Poisson-distributed off- and on-intensities, demonstrating that the observed non-Poissonian on-intensity distribution of the QDs is not a product of the underlying power-law probability and that the blinking of QDs occurs between a non-emitting off-state and a distribution of emitting on-states with different intensities. All the experimentally observed photo-induced effects could be accounted for by introducing a characteristic lifetime tPI of the on-state in the simulations. The QDs on glass presented a tPI proportional to P-1 suggesting the presence of a one-photon process. Light scattering images and spectra of colloidal and C-shaped gold nano-particles were acquired. The minimum size of a metallic scatterer detectable with the SCOM lies around 20 nm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis presents a new imaging technique for ultracold quantum gases. Since the first observation of Bose-Einstein condensation, ultracold atoms have proven to be an interesting system to study fundamental quantum effects in many-body systems. Most of the experiments use optical imaging rnmethods to extract the information from the system and are therefore restricted to the fundamental limitation of this technique: the best achievable spatial resolution that can be achieved is comparable to the wavelength of the employed light field. Since the average atomic distance and the length scale of characteristic spatial structures in Bose-Einstein condensates such as vortices and solitons is between 100 nm and 500 nm, an imaging technique with an adequate spatial resolution is needed. This is achieved in this work by extending the method of scanning electron microscopy to ultracold quantum gases. A focused electron beam is scanned over the atom cloud and locally produces ions which are subsequently detected. The new imaging technique allows for the precise measurement of the density distribution of a trapped Bose-Einstein condensate. Furthermore, the spatial resolution is determined by imaging the atomic distribution in one-dimensional and two-dimensional optical lattices. Finally, the variety of the imaging method is demonstrated by the selective removal of single lattice site. rn

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND To determine the effect of photoactivated disinfection (PAD) using toluidine blue and a light-emitting diode (LED) in the red spectrum (wave length at 625-635 nm) on species associated with periodontitis and peri-implantitis and bacteria within a periodontopathic biofilm. METHODS Sixteen single microbial species including 2 Porphyromonas gingivalis and 2 Aggregatibacter actinomycetemcomitans and a multispecies mixture consisting of 12 species suspended in saline without and with 25% human serum were exposed to PAD. Moreover, single-species biofilms consisting of 2 P. gingivalis and 2 A. actinomycetemcomitans strains and a multi-species biofilm on 24-well-plates, grown on titanium discs and in artificial periodontal pockets were exposed to PAD with and without pretreatment with 0.25% hydrogen peroxide. Changes in the viability were determined by counting the colony forming units (cfu). RESULTS PAD reduced the cfu counts in saline by 1.42 log₁₀ after LED application for 30s and by 1.99 log₁₀ after LED application for 60s compared with negative controls (each p<0.001). Serum did not inhibit the efficacy of PAD. PAD reduced statistically significantly (p<0.05) the cfu counts of the P. gingivalis biofilms. The viability of the A. actinomycetemcomitans biofilms and the multi-species biofilms was statistically significantly decreased when PAD was applied after a pretreatment with 0.25% hydrogen peroxide. The biofilm formed in artificial pockets was more sensitive to PAD with and without pretreatment with hydrogen peroxide compared with those formed on titanium discs. CONCLUSIONS PAD using a LED was effective against periodontopathic bacterial species and reduced viability in biofilms but was not able to completely destroy complex biofilms. The use of PAD following pretreatment with hydrogen peroxide resulted in an additional increase in the antimicrobial activity which may represent a new alternative to treat periodontal and peri-implant infections thus warranting further testing in clinical studies.