907 resultados para Coronary
Resumo:
The purpose of this study was to prospectively compare free-breathing navigator-gated cardiac-triggered three-dimensional steady-state free precession (SSFP) spin-labeling coronary magnetic resonance (MR) angiography performed by using Cartesian k-space sampling with that performed by using radial k-space sampling. A new dedicated placement of the two-dimensional selective labeling pulse and an individually adjusted labeling delay time approved by the institutional review board were used. In 14 volunteers (eight men, six women; mean age, 28.8 years) who gave informed consent, signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), vessel sharpness, vessel length, and subjective image quality were investigated. Differences between groups were analyzed with nonparametric tests (Wilcoxon, Pearson chi2). Radial imaging, as compared with Cartesian imaging, resulted in a significant reduction in the severity of motion artifacts, as well as an increase in SNR (26.9 vs 12.0, P < .05) in the coronary arteries and CNR (23.1 vs 8.8, P < .05) between the coronary arteries and the myocardium. A tendency toward improved vessel sharpness and vessel length was also found with radial imaging. Radial SSFP imaging is a promising technique for spin-labeling coronary MR angiography.
Resumo:
IPH has estimated and forecast clinical diagnosis rates of CHD (heart attack and/or angina) among adults for the years 2010, 2015 and 2020. In the Republic of Ireland, the data are based on the Survey of Lifestyle, Attitudes and Nutrition (SLÁN) 2007 . The data describe the number of people who report that they have experienced doctor-diagnosed heart attack and/or angina in the previous 12 months (annual clinical diagnosis). Data is available by age and sex for each Local Health Office of the Health Service Executive (HSE) in the Republic of Ireland. In Northern Ireland, the data are based on the Health and Social Wellbeing Survey 2005/06 . The data describe the number of people who report that they have experienced doctor-diagnosed heart attack and/or angina at any time in the past (lifetime clinical diagnosis). Data are available by age and sex for each Local Government District in Northern Ireland. Clinical diagnosis rates in the Republic of Ireland relate to the previous 12 months and are not directly comparable with clinical diagnosis rates in Northern Ireland which relate to anytime in the past. The IPH estimated prevalence per cents may be marginally different to estimated prevalence per cents taken directly from the reference study. There are two reasons for this: 1) The IPH prevalence estimates relate to 2010 while the reference studies relate to earlier years (Northern Ireland Health and Social Wellbeing Survey 2005/06, Survey of Lifestyle, Attitudes and Nutrition 2007, Understanding Society 2009). Although we assume that the risk of the condition in the risk groups do not change over time, the distribution of the number of people in the risk groups in the population changes over time (eg the population ages). This new distribution of the risk groups in the population means that the risk of the condition is weighted differently to the reference study and this results in a different overall prevalence estimate. 2) The IPH prevalence estimates are based on a statistical model of the reference study. The model includes a number of explanatory variables to predict the risk of the condition. Therefore the model does not include records from the reference study that are missing data on these explanatory variables. A prevalence estimate for a condition taken directly from the reference study would include these records.
Resumo:
The feasibility of three-dimensional (3D) whole-heart imaging of the coronary venous (CV) system was investigated. The hypothesis that coronary magnetic resonance venography (CMRV) can be improved by using an intravascular contrast agent (CA) was tested. A simplified model of the contrast in T(2)-prepared steady-state free precession (SSFP) imaging was applied to calculate optimal T(2)-preparation durations for the various deoxygenation levels expected in venous blood. Non-contrast-agent (nCA)- and CA-enhanced images were compared for the delineation of the coronary sinus (CS) and its main tributaries. A quantitative analysis of the resulting contrast-to-noise ratio (CNR) and signal-to-noise ratio (SNR) in both approaches was performed. Precontrast visualization of the CV system was limited by the poor CNR between large portions of the venous blood and the surrounding tissue. Postcontrast, a significant increase in CNR between the venous blood and the myocardium (Myo) resulted in a clear delineation of the target vessels. The CNR improvement was 347% (P < 0.05) for the CS, 260% (P < 0.01) for the mid cardiac vein (MCV), and 430% (P < 0.05) for the great cardiac vein (GCV). The improvement in SNR was on average 155%, but was not statistically significant for the CS and the MCV. The signal of the Myo could be significantly reduced to about 25% (P < 0.001).
Resumo:
To assess the impact of admission to different hospital types on early and 1-year outcomes in patients with acute coronary syndrome (ACS). Between 1997 and 2009, 31 010 ACS patients from 76 Swiss hospitals were enrolled in the AMIS Plus registry. Large tertiary institutions with continuous (24 hour/7 day) cardiac catheterisation facilities were classified as type A hospitals, and all others as type B. For 1-year outcomes, a subgroup of patients admitted after 2005 were studied. Eleven type A hospitals admitted 15987 (52%) patients and 65 type B hospitals 15023 (48%) patients. Patients admitted into B hospitals were older, more frequently female, diabetic, hypertensive, had more severe comorbidities and more frequent non-ST segment elevation (NSTE)-ACS/unstable angina (UA). STE-ACS patients admitted into B hospitals received more thrombolysis, but less percutaneous coronary intervention (PCI). Crude in-hospital mortality and major adverse cardiac events (MACE) were higher in patients from B hospitals. Crude 1-year mortality of 3747 ACS patients followed up was higher in patients admitted into B hospitals, but no differences were found for MACE. After adjustment for age, risk factors, type of ACS and comorbidities, hospital type was not an independent predictor of in-hospital mortality, in-hospital MACE, 1-year MACE or mortality. Admission indicated a crude outcome in favour of hospitalisation during duty-hours while 1-year outcome could not document a significant effect. ACS patients admitted to smaller regional Swiss hospitals were older, had more severe comorbidities, more NSTE-ACS and received less intensive treatment compared with the patients initially admitted to large tertiary institutions. However, hospital type was not an independent predictor of early and mid-term outcomes in these patients. Furthermore, our data suggest that Swiss hospitals have been functioning as an efficient network for the past 12 years.
Resumo:
PURPOSE: To determine the diagnostic value of the intravascular contrast agent gadocoletic acid (B-22956) in three-dimensional, free breathing coronary magnetic resonance angiography (MRA) for stenosis detection in patients with suspected or known coronary artery disease. METHODS: Eighteen patients underwent three-dimensional, free breathing coronary MRA of the left and right coronary system before and after intravenous application of a single dose of gadocoletic acid (B-22956) using three different dose regimens (group A 0.050 mmol/kg; group B 0.075 mmol/kg; group C 0.100 mmol/kg). Precontrast scanning followed a coronary MRA standard non-contrast T2 preparation/turbo-gradient echo sequence (T2Prep); for postcontrast scanning an inversion-recovery gradient echo sequence was used (real-time navigator correction for both scans). In pre- and postcontrast scans quantitative analysis of coronary MRA data was performed to determine the number of visible side branches, vessel length and vessel sharpness of each of the three coronary arteries (LAD, LCX, RCA). The number of assessable coronary artery segments was determined to calculate sensitivity and specificity for detection of stenosis > or = 50% on a segment-to-segment basis (16-segment-model) in pre- and postcontrast scans with x-ray coronary angiography as the standard of reference. RESULTS: Dose group B (0.075 mmol/kg) was preferable with regard to improvement of MR angiographic parameters: in postcontrast scans all MR angiographic parameters increased significantly except for the number of visible side branches of the left circumflex artery. In addition, assessability of coronary artery segments significantly improved postcontrast in this dose group (67 versus 88%, p < 0.01). Diagnostic performance (sensitivity, specificity, accuracy) was 83, 77 and 78% for precontrast and 86, 95 and 94% for postcontrast scans. CONCLUSIONS: The use of gadocoletic acid (B-22956) results in an improvement of MR angiographic parameters, asssessability of coronary segments and detection of coronary stenoses > or = 50%.
Resumo:
Background: The incidence of cardiovascular events in HIV patients has fallen. Methods: We identified 81 patients with a history of coronary events from 2 hospitals in Spain to evaluate management of CVRF before and after the event. Results: The prevalence of coronary events was 2.15%. At the time of the coronary event, CVRF were highly prevalent. Decrease in total cholesterol (P=0.025) and LDLc(P=0.004) was observed. LDLc and HDLc were determined and the percentage of patients with LDLc &100 mg/dL remained stable at the last visit. Conclusions: The prevalence of coronary disease in our cohort was low. Although CVRF were highly.
Resumo:
Percutaneous transluminal coronary angioplasty (PTCA) is a widely accepted treatment of symptomatic coronary heart disease providing prompt and prolonged clinical, improvement in most patients. We have examined the value of this therapy in a group of 91 patients in their eighth decade treated by 133 consecutive angioplasties. Most patients had refractory or instable angor in spite of optimal pharmacotherapy. Multivessel disease was present in 67% and maintained left-ventricular function in 92% of the patients. The angiographic success rate of PTCA was 84%; technical failures occurred in 12% and adverse events in 14%. Two patients died. The rate of symptomatic restenosis was 24%. Survival and patients free of myocardial events were at 89% and 60%, respectively, estimated by Kaplan-Meier analysis. PTCA is an efficient and acceptable treatment for the elderly patient with severe and drug-resistant angina. Two years after PTCA the majority of patients was asymptomatic.
Resumo:
OBJECTIVES: The role of beta-blockers in the treatment of hypertension is discussed controversially and the data showing a clear benefit in acute coronary syndromes (ACS) were obtained in the thrombolysis era. The goal of this study was to analyze the role of pretreatment with beta-blockers in patients with ACS. METHODS: Using data from the Acute Myocardial Infarction in Switzerland (AMIS Plus) registry, we analyzed outcomes of patients with beta-blocker pretreatment in whom they were continued during hospitalization (group A), those without beta-blocker pretreatment but with administration after admission (group B) and those who never received them (group C). Major adverse cardiac events defined as composed endpoint of re-infarction and stroke (during hospitalization) and/or in-hospital death were compared between the groups. RESULTS: A total of 24,709 patients were included in the study (6,234 in group A, 12,344 in group B, 6,131 in group C). Patients of group B were younger compared to patients of group A and C (62.5, 67.6 and 68.4, respectively). In the multivariate analysis, odds ratio for major adverse cardiac events was 0.59 (CI 0.47-0.74) for group A and 0.66 (CI 0.55-0.83) for group B, while group C was taken as a reference. CONCLUSIONS: beta-Blocker therapy is beneficial in ACS and they should be started in those who are not pretreated and continued in stable patients who had been on chronic beta-blocker therapy before.
Resumo:
RATIONALE AND OBJECTIVES: Recent developments of MR imaging equipment enabled high-quality steady state-free-precession (Balanced FFE, True-FISP) MR-imaging with a substantial 'T2 like' contrast, resulting in a high signal intensity of the blood-pool without the application of exogenous contrast agents. It is hypothesized that Balanced-FFE may be valuable for contrast enhancement in 3D free-breathing coronary MRA. MATERIALS AND METHODS: Navigator-gated free-breathing cardiac triggered coronary MRA was performed in 10 healthy adult subjects and three patients with radiograph defined coronary artery disease using a segmented k-space 3D Balanced FFE imaging sequence. RESULTS: High contrast-to-noise ratio between the blood-pool and the myocardium (29 +/- 8) and long segment visualization of both coronary arteries could be obtained in about 5 minutes during free breathing using the present navigator-gated Balanced-FFE coronary MRA approach. First patient results demonstrated successful display of coronary artery stenoses. CONCLUSION: Balanced FFE offers a potential alternative for endogenous contrast enhancement in navigator-gated free-breathing 3D coronary MRA. The obtained results together with the relatively short scanning time warrant further studies in larger patient collectives.
Resumo:
PURPOSE: To investigate the feasibility of high-resolution selective three-dimensional (3D) magnetic resonance coronary angiography (MRCA) in the evaluation of coronary artery stenoses. MATERIALS AND METHODS: In 12 patients with coronary artery stenoses, MRCA of the coronary artery groups, including the coronary segments with stenoses of 50% or greater based on conventional x-ray coronary angiography (CAG), was performed with double-oblique imaging planes by orienting the 3D slab along the major axis of each right coronary artery-left circumflex artery (RCA-LCX) group and each left main trunk-left anterior descending artery (LMT-LAD) group. Ten RCA-LCX and five LMT-LAD MR angiograms were obtained, and the results were compared with those of conventional x-ray angiography. RESULTS: Among 70 coronary artery segments expected to be covered, a total of 49 (70%) segments were fully demonstrated in diagnostic quality. The identification of segmental location of stenoses showed as high an accuracy as 96%. The retrospective analysis for stenosis of 50% or greater yielded the sensitivity, specificity, and accuracy of 80%, 85%, and 84%, respectively. CONCLUSION: Selective 3D MRCA has the potential for segment-by-segment evaluation of major portions of the right and left coronary arteries with high accuracy.
Resumo:
The Emergency Department Assessment of Women with Acute Coronary Syndrome Click here to download PDF 353kb
Resumo:
Navigator-gated and corrected 3D coronary MR angiography (MRA) allows submillimeter image acquisition during free breathing. However, cranial diaphragmatic drift and relative phase shifts of chest-wall motion are limiting factors for image quality and scanning duration. We hypothesized that image acquisition in the prone position would minimize artifacts related to chest-wall motion and suppress diaphragmatic drift. Twelve patients with radiographically-confirmed coronary artery disease and six healthy adult volunteers were studied in both the prone and the supine position during free-breathing navigator-gated and corrected 3D coronary MRA. Image quality and the diaphragmatic positions were objectively compared. In the prone position, there was a 36% improvement in signal-to-noise ratio (SNR; 15.5 +/- 2.7 vs. 11.4 +/- 2.6; P < 0.01) and a 34% improvement in CNR (12.5 +/- 3.3 vs. 9.3 +/- 2.5, P < 0.01). The prone position also resulted in a 17% improvement in coronary vessel definition (P < 0.01). Cranial end-expiratory diaphragmatic drift occurred less frequently in the prone position (23% +/- 17% vs. 40% +/- 26% supine; P <0.05), and navigator efficiency was higher. Prone coronary MRA results in improved SNR and CNR with enhanced coronary vessel definition. Cranial end-expiratory diaphragmatic drift also was reduced, and navigator efficiency was enhanced. When feasible, prone imaging is recommended for free-breathing coronary MRA.
Resumo:
OBJECTIVE: The optimal coronary MR angiography sequence has yet to be determined. We sought to quantitatively and qualitatively compare four coronary MR angiography sequences. SUBJECTS AND METHODS. Free-breathing coronary MR angiography was performed in 12 patients using four imaging sequences (turbo field-echo, fast spin-echo, balanced fast field-echo, and spiral turbo field-echo). Quantitative comparisons, including signal-to-noise ratio, contrast-to-noise ratio, vessel diameter, and vessel sharpness, were performed using a semiautomated analysis tool. Accuracy for detection of hemodynamically significant disease (> 50%) was assessed in comparison with radiographic coronary angiography. RESULTS: Signal-to-noise and contrast-to-noise ratios were markedly increased using the spiral (25.7 +/- 5.7 and 15.2 +/- 3.9) and balanced fast field-echo (23.5 +/- 11.7 and 14.4 +/- 8.1) sequences compared with the turbo field-echo (12.5 +/- 2.7 and 8.3 +/- 2.6) sequence (p < 0.05). Vessel diameter was smaller with the spiral sequence (2.6 +/- 0.5 mm) than with the other techniques (turbo field-echo, 3.0 +/- 0.5 mm, p = 0.6; balanced fast field-echo, 3.1 +/- 0.5 mm, p < 0.01; fast spin-echo, 3.1 +/- 0.5 mm, p < 0.01). Vessel sharpness was highest with the balanced fast field-echo sequence (61.6% +/- 8.5% compared with turbo field-echo, 44.0% +/- 6.6%; spiral, 44.7% +/- 6.5%; fast spin-echo, 18.4% +/- 6.7%; p < 0.001). The overall accuracies of the sequences were similar (range, 74% for turbo field-echo, 79% for spiral). Scanning time for the fast spin-echo sequences was longest (10.5 +/- 0.6 min), and for the spiral acquisitions was shortest (5.2 +/- 0.3 min). CONCLUSION: Advantages in signal-to-noise and contrast-to-noise ratios, vessel sharpness, and the qualitative results appear to favor spiral and balanced fast field-echo coronary MR angiography sequences, although subjective accuracy for the detection of coronary artery disease was similar to that of other sequences.