921 resultados para Corneal hysteresis


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (doctoral)--Vereinigte Friedrichs-Universitat Halle-Wittenberg.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (doctoral)--Ludwigs-Universität Giessen, 1895.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Thesis (doctoral)--Universitat Zurich.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of a gas flow field on the size of raceway has been studied experimentally using a two-dimensional (2-D) cold model. It is observed that as the blast velocity from the tuyere increases, raceway size increases, and when the blast velocity is decreased from its highest value, raceway size does not change much until the velocity reaches a critical velocity. Below the critical velocity, raceway size decreases with decreasing velocity but is always larger than that for the same velocity when the velocity increased. This phenomenon is called raceway hysteresis. Raceway hysteresis has been studied in the presence of different gas flow rates and different particle densities. Raceway hysteresis has been observed in all the experiments. The effect of liquid flow, with various superficial velocities, on raceway hysteresis has also been studied. A study of raceway size hysteresis shows that interparticle and particle-wall friction have a very large effect on raceway size. A hypothesis has been proposed to describe the hysteresis phenomenon in the packed beds. The relevance of hysteresis to blast furnace raceways has been discussed. Existing literature correlations for raceway size ignore the frictional effects. Therefore, their applicability to the ironmaking blast furnace is questionable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Differential heart rates during heating and cooling (heart rate hysteresis) are an important thermoregulatory mechanism in ectothermic reptiles. We speculate that heart rate hysteresis has evolved alongside vascularisation, and to determine whether this phenomenon occurs in a lineage with vascularised circulatory systems that is phylogenetically distant from reptiles, we measured the response of heart rate to convective heat transfer in the Australian freshwater crayfish, Cherax destructor. Heart rate during convective heating (from 20 to 30 degreesC) was significantly faster than during cooling for any given body temperature. Heart rate declined rapidly immediately following the removal of the heat source, despite only negligible losses in body temperature. This heart rate 'hysteresis' is similar to the pattern reported in many reptiles and, by varying peripheral blood flow, it is presumed to confer thermoregulatory benefits particularly given the thermal sensitivity of many physiological rate functions in crustaceans. (C) 2004 Published by Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate the efficacy of hyperbaric oxygen therapy in the treatment of alkali-induced corneal burns in an animal model. Methods: Twenty-four rabbits were randomized into a control group (n = 12) and hyperbaric oxygen treatment group (n = 12). After induction of anaesthesia, the alkali burn model was established by application of 1 N sodium hydroxide to one eye of each rabbit. The hyperbaric oxygen treatment group was treated each day for 21 days with hyperbaric oxygen at 2.4 Atmospheres Absolute (ATA) for 1 h. The eyes of the animals were examined daily for 2 weeks and then weekly until the end of the trial. The principal endpoint was that of perforation of the cornea at which time the animals were killed with a lethal dose of either intravenous or intraperitoneal barbiturate and the eyes immediately enucleated and fixed in 10% neutral buffered formalin. All animals in which complete healing took placed were also killed, the eyes removed, fixed and examined histologically. Photographs were taken of the rabbit's eyes at weekly intervals and the area of vascularization and epithelial defects in the hyperbaric and control groups were compared. Results: Equal numbers (seven) of the control and hyperbaric oxygen treated groups had perforated corneas and there was no statistical difference in the mean time to perforation (control 30.1 days; treated 30 days). There was also no statistical difference between the two groups with respect to epithelial defect size. Conclusion: Treatment with hyperbaric oxygen for 1 h daily for 21 days had no beneficial effect on alkali-induced corneal burns.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. To compare the efficacy of two forms of eye care (hypromellose and Lacri-Lube combination vs polyethylene/Cling wrap covers) for intensive care patients. Design. Randomised-controlled trial. Setting. University affiliated, tertiary referral hospital. Patients and participants. One hundred ten patients with a reduced or absent blink reflex were followed through until they regained consciousness, were discharged from the facility during study enrolment, died or developed a positive corneal ulcer or eye infection. Interventions. All patients received standard eye cleansing every 2 h. In addition to this, group one (n=60) received a treatment combining hypromellose drops and Lacri-Lube (HL) to each eye every 2 h. Group two (n=50) had polyethylene covers only placed over the eye to create a moisture chamber. Measurements and results. Corneal ulceration was determined using corneal fluorescein stains and mobile slit lamp evaluation, performed daily. No patients had corneal ulceration in the polyethylene cover group, but 4 patients had corneal ulceration in the HL group. Conclusions. Polyethylene covers are as effective as HL in reducing the incidence of corneal damage in intensive care patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The presence of primary cilia in corneal endothelial cells of a range of species from six non-mammalian vertebrate classes (Agnatha, Elasmobranchii, Amphibia, Teleostei, Reptilia, and Aves) is examined by scanning and transmission electron microscopy. Our aim is to assess whether these non-motile cilia protruding into the anterior chamber of the eye are a consistent phylogenetic feature of the corneal endothelium and if a quantitative comparison of their morphology is able to shed any new light on their function. The length (0.42-3.80 mum) and width (0.12-0.44 mum) of the primary cilia varied but were closely allied with previous studies in mammals. However, interspecific differences such as the presence of a terminal swelling in the Teleostei and Amphibia suggest there are functional differences. Approximately one-third of the endothelial cells possess cilia but the extent of protrusion above the cell surface varies greatly, supporting a dynamic process of retraction and elongation. The absence of primary cilia in primitive vertebrates (Agnatha and Elasmobranchii) that possess other mechanisms to control corneal hydration suggests an osmoregulatory and/or chemosensory function. (C) 2003 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An X-ray visualization technique has been used for the quantitative determination of local liquid holdups distribution and liquid holdup hysteresis in a nonwetting two-dimensional (2-D) packed bed. A medical diagnostic X-ray unit has been used to image the local holdups in a 2-D cold model having a random packing of expanded polystyrene beads. An aqueous barium chloride solution was used as a fluid to achieve good contrast on X-ray images. To quantify the local liquid holdup, a simple calibration technique has been developed that can be used for most of the radiological methods such as gamma ray and neutron radiography. The global value of total liquid holdup, obtained by X-ray method, has been compared with two conventional methods: drainage and tracer response. The X-ray technique, after validation, has been used to visualize and quantify, the liquid hysteresis phenomena in a packed bed. The liquid flows in preferred paths or channels that carry droplets/rivulets of increasing size and number as the liquid flow rate is increased. When the flow is reduced, these paths are retained and the higher liquid holdup that persists in these regions leads to the holdup hysteresis effect. Holdup in some regions of the packed bed may be an order of magnitude higher than average at a particular flow rate. (c) 2005 American Institute of Chemical Engineers

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To report a case of a perforated acute hydrops in a mentally retarded patient that was successfully managed with intracameral sulfur hexafluoride gas and cyanoacrylate tissue adhesive. Methods: Interventional case report. Results: A 14-year-old mentally retarded male patient with keratoconus presented with a perforated acute hydrops. A bandage contact lens was applied. However, following a large emesis 2 days later, the aqueous leak worsened with shallowing of the anterior chamber. Under general anesthesia, sulfur hexafluoride was injected to reform the anterior chamber and cyanoacrylate tissue adhesive was applied to the perforated site and covered by a bandage contact lens and temporary tarsorrhaphy. A follow-up examination at 1 month showed a formed anterior chamber with tissue adhesive in situ and no aqueous leak. Conclusions: The successful use of intracameral sulfur hexafluoride and tissue adhesive in the management of perforated acute hydrops may avoid emergency tectonic penetrating keratoplasty and reduce potential complications in the poorly cooperative patient.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When a gas is introduced at high velocity through a nozzle into a packed bed, it creates a raceway in the packed bed. It has been found that the raceway size is larger when it is formed by decreasing the gas velocity from its highest value than when it is formed by increasing the gas velocity. This phenomenon is known as raceway hysteresis. A hypothesis has been oroposed to explain the hysteresis phenomenon based on a force-balance approach which includes frictional, bed-weight, and pressure forces. According to this hypothesis, the frictional force acts in different directions when the raceway is expanding and contracting. In this article, the entire packed bed has been divided into radial and Cartesian co-ordinate systems, and the forces acting on the raceway have been solved analytically for a simplified one-dimensional case. Based on the force-balance approach, a general equation has been obtained to predict the diameter of the raceway for increasing And decreasing velocities. A reasonable agreement has been found between the theoretical predictions and experimental observations. The model has also been compared with published experimental and plant data. The hysteresis mechanism in the packed beds can be described reasonably by taking into consideration the direction of frictional forces for the increasing- and decreasin-velocity cases. The effects of the particleshape factor and void fraction on the raceway hysteresis are examined.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hysteresis models that eliminate the artificial pumping errors associated with the Kool-Parker (KP) soil moisture hysteresis model, such as the Parker-Lenhard (PL) method, can be computationally demanding in unsaturated transport models since they need to retain the wetting-drying history of the system. The pumping errors in these models need to be eliminated for correct simulation of cyclical systems (e.g. transport above a tidally forced watertable, infiltration and redistribution under periodic irrigation) if the soils exhibit significant hysteresis. A modification is made here to the PL method that allows it to be more readily applied to numerical models by eliminating the need to store a large number of soil moisture reversal points. The modified-PL method largely eliminates any artificial pumping error and so essentially retains the accuracy of the original PL approach. The modified-PL method is implemented in HYDRUS-1D (version 2.0), which is then used to simulate cyclic capillary fringe dynamics to show the influence of removing artificial pumping errors and to demonstrate the ease of implementation. Artificial pumping errors are shown to be significant for the soils and system characteristics used here in numerical experiments of transport above a fluctuating watertable. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Phakometric measurements of corneal and crystalline lens surface alignment are influenced by corneal asymmetry in which the corneal apex does not coincide with the limbal centre. The purpose of this study was to determine the horizontal separation (e) between these corneal landmarks. Measurements were made in 60 normal eyes (30 subjects) using the Orbscan Ilz corneal analysis workstation. Our results show that both corneal landmarks typically coincide, so that e = 0, but that inter-subject variations of about ±1 mm can be expected (so that the corneal apex may fall nasal or temporal to the visual axis). This suggests that no correction for corneal asymmetry is required when estimating average amounts of ocular alignment from samples of eyes but that the measurement of e is strongly recommended for measurements in individual eyes. © 2004 The College of Optometrists.