960 resultados para Contrast echocardiography
Resumo:
The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.
Resumo:
The analysis of histological sections has long been a valuable tool in the pathological studies. The interpretation of tissue conditions, however, relies directly on visual evaluation of tissue slides, which may be difficult to interpret because of poor contrast or poor color differentiation. The Chromatic Contrast Visualization System (CCV) combines an optical microscope with electronically controlled light-emitting diodes (LEDs) in order to generate adjustable intensities of RGB channels for sample illumination. While most image enhancement techniques rely on software post-processing of an image acquired under standard illumination conditions, CCV produces real-time variations in the color composition of the light source itself. The possibility of covering the entire RGB chromatic range, combined with the optical properties of the different tissues, allows for a substantial enhancement in image details. Traditional image acquisition methods do not exploit these visual enhancements which results in poorer visual distinction among tissue structures. Photodynamic therapy (PDT) procedures are of increasing interest in the treatment of several forms of cancer. This study uses histological slides of rat liver samples that were induced to necrosis after being exposed to PDT. Results show that visualization of tissue structures could be improved by changing colors and intensities of the microscope light source. PDT-necrosed tissue samples are better differentiated when illuminated with different color wavelengths, leading to an improved differentiation of cells in the necrosis area. Due to the potential benefits it can bring to interpretation and diagnosis, further research in this field could make CCV an attractive technique for medical applications.
Resumo:
Recently, the deterministic tourist walk has emerged as a novel approach for texture analysis. This method employs a traveler visiting image pixels using a deterministic walk rule. Resulting trajectories provide clues about pixel interaction in the image that can be used for image classification and identification tasks. This paper proposes a new walk rule for the tourist which is based on contrast direction of a neighborhood. The yielded results using this approach are comparable with those from traditional texture analysis methods in the classification of a set of Brodatz textures and their rotated versions, thus confirming the potential of the method as a feasible texture analysis methodology. (C) 2010 Elsevier B.V. All rights reserved.
Resumo:
Introdução: Embora a imagem com segunda harmônica esteja largamente disponível na maioria dos aparelhos de ultra-sonografia, sua acurácia para avaliar a morfologia e a função do apêndice atrial esquerdo (AAE) permanece precariamente caracterizada. Objetivos: Explorar o desempenho diagnóstico da ecocardiografia transtorácica com segunda harmônica (ETTsh) na avaliação do AAE após eventos neurológicos agudos. Métodos: Realizamos um estudo transversal em pacientes com eventos neurológicos isquêmicos agudos, encaminhados para realização de ETTsh e Ecocardiografia Transesofágica (ETE). As análises da área longitudinal máxima e do pico da velocidade de esvaziamento de fluxo do AAE foram realizadas por observadores cegos. Resultados: Foram avaliados 51 pacientes (49% femininas, 62 ± 12 anos) com eventos neurológicos isquêmicos agudos. Contraste ecocardiográfico espontâneo foi observado em 11 (22%) pacientes no AE, em 7(14%) no AAE e em 3 (6%) na aorta torácica descendente. Trombo no AAE foi identificado em apenas 2 (4%) pacientes. O mapeamento e a análise do AAE foi factível na maioria dos casos (98%), tanto para o estudo com Doppler quanto para avaliação da área do AAE. Observamos uma associação positiva e significativa entre o ETTsh e o ETE, tanto para a avaliação das velocidades máximas de esvaziamento do AAE (r=0,63; p<0,001) quanto para a área longitudinal máxima do AAE (r=0,73; p<0,001). Ademais, todos os pacientes com trombos no AAE ou contraste espontâneo (n=7) tiveram velocidade de esvaziamento inferior a 50 cm/s no mapeamento transtorácico (valor preditivo negativo de 100%). Na análise multivariada ajustada para diversos potenciais preditores transtorácicos de risco, a velocidade máxima de esvaziamento do AAE permaneceu independentemente associada com trombos no AAE ou contraste espontâneo. Conclusão: ETTsh pode fornecer informações relevantes a respeito da morfologia e dinâmica do AAE. Em particular, pacientes com velocidades altas de esvaziamento do AAE podem não necessitar de avaliação adicional com ETE.
Resumo:
Recruiters make many inferences about applicants' abilities and interpersonal attributes on the basis of applicants' resumes. For example, every once in a while, a good resume leaves a strong positive impression and the recruiter creates a high expectation for the selection interview. What if a disappointing interview follows? Will the great resume help or hurt the candidate? The purpose of this study is to assess the impact of a good resume on the recruiter’s evaluation of a candidate when a non-enthusiastic interview follows as well as the interacting role of gender. The results of two online experiments (n=454) where participants played the role of the recruiter, showed that, on average, a very good resume (vs. no resume) before a non-enthusiastic interview did not affect the recruiter’s evaluation of the candidate. However, when the recruiter’s and the candidate’s gender were taken into consideration, a different picture emerged. While no effect was found for male recruiters, the candidate’s resume had a clear significant impact on female recruiter’s evaluations: when the candidate was also a female, the good resume shown before the non-enthusiastic interview performance tended to help, whereas when the candidate was a male, the good resume had a significant negative effect on female recruiters’ evaluation of the candidate. In sum, in situations where the resume had a strong impact on the recruiter’s evaluation (female recruiters), the direction of the effect was moderated by the candidate’s gender. Gender differences in information processing as well as in-group/out-group biases due to gender matching are used to hypothesize and explain the main findings.
Resumo:
Aim. Duplex scanning has been used in the evaluation of the aorta and proximal arteries of the lower extremities, but has limitations in evaluating the arteries of the leg. The utilization of ultrasonographic contrast (USC) may be helpful in improving the quality of the image in these arteries. The objective of the present study was to verify whether the USC increases the diagnostic accuracy of patency of the leg arteries and if it diminishes the time needed to perform duplex scanning.Methods. Twenty patients with critical ischemia (20 lower extremities) were examined by standard duplex scanning, duplex scanning with contrast and digital subtraction arteriography (DSA). The 3 arteries of the leg were divided into 3 segments, for a total of 9 segments per limb. Each segment was evaluated for patency in order to compare the 3 diagnostic methods. Comparison was made between standard duplex scanning and duplex scanning with contrast in terms of quality of the color-coded Doppler signal and of the spectral curve, and also of the time to perform the exams.Results. Duplex scanning with contrast was similar to arteriography in relation to patency diagnosis (p>0.3) and even superior in some of the segments. Standard duplex scanning was inferior to arteriography and to duplex scanning with contrast (p<0.001). There were improvements of 70% in intensity of the color-coded Doppler signal and 76% in the spectral curve after the utilization of contrast. The time necessary to perform the examinations was 23.7 minutes for standard duplex scanning and 16.9 minutes for duplex scanning with contrast (p<0.001).Conclusion. The use of ultrasonographic contrast increased the accuracy of the diagnosis of patency of leg arteries and diminished the time necessary for the execution of duplex scanning.
Resumo:
OBJECTIVE: To assess the cardiovascular features of Ullrich-Turner's syndrome using echocardiography and magnetic resonance imaging, and to correlate them with the phenotype and karyotype of the patients. The diagnostic concordance between the 2 methods was also assessed. METHODS: Fifteen patients with the syndrome were assessed by echocardiography and magnetic resonance imaging (cardiac chambers, valves, and aorta). Their ages ranged from 10 to 28 (mean of 16.7) years. The karyotype was analyzed in 11 or 25 metaphases of peripheral blood lymphocytes, or both. RESULTS: The most common phenotypic changes were short stature and spontaneous absence of puberal development (100%); 1 patient had a cardiac murmur. The karyotypes detected were as follows: 45,X (n=7), mosaics (n=5), and deletions (n=3). No echocardiographic changes were observed. In regard to magnetic resonance imaging, coarctation and dilation of the aorta were found in 1 patient, and isolated dilation of the aorta was found in 4 patients. CONCLUSION: The frequencies of coarctation and dilation of the aorta detected on magnetic resonance imaging were similar to those reported in the literature (5.5% to 20%, and 6.3% to 29%, respectively). This confirmed the adjuvant role of magnetic resonance imaging to Doppler echocardiography for diagnosing cardiovascular alterations in patients with Ullrich-Turner's syndrome.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
The aim of this study was to evaluate the shrinkage of a microhybrid dental composite resin photo-activated by one LED with different power densities by means of speckle technique. The dental composite resin Filtek (TM) Z-250 (3M/ESPE) at color A(2) was used for the samples preparation. Uncured composite was packed in a metallic mold and irradiated during 20 s from 100 to 1000 mW cm(-2). For the photo-activation of the samples, it was used a LED prototype (Light Emission Diode) with wavelength centered at 470 nm and adjustable power density until 1 W cm(-2). The speckle patterns obtained from the bottom composite surfaces were monitored using a CCD camera without lens. The speckle field is recorded in a digital picture and stored by CCD camera as the carrier of information on the displacement of the tested surface. The calculated values were obtained for each pair of adjacent patterns and the changes in speckle contrast as a function of time were obtained from six repeated measurements. The speckle contrasts obtained from the bottom surface with 100 mW cm(-1) were smaller than those than the other power densities. The higher power densities provided the higher shrinkage.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
1. A method for obtaining the end-systolic left ventricular (LV) pressure-diameter and stress-diameter relationships in man was critically analyzed.2. Pressure-diameter and stress-diameter relationships were determined throughout the cardiac cycle by combining standard LV manometry with M-mode echocardiography. Nine adult patients with heart disease and without heart failure were studied during intracardiac catheterization under three different conditions of arterial pressure, i.e., basal (B) condition (mean +/- SD systolic pressure, 102 +/- 10 mmHg) and two stable states of arterial hypertension (H(I), 121 +/- 12 mmHg; H(II), 147 +/- 17 mmHg) induced by venous infusion of phenylephrine after parasympathetic autonomic blockade with 0.04 mg/kg atropine.3. Significant reflex heart rate variation with arterial hypertension was observed (B, 115 +/- 20 bpm; H(I), 103 +/- 14 bpm; H(II), 101 +/- 13 bpm) in spite of the parasympathetic blockade with atropine. The linear end-systolic pressure-diameter and stress-diameter relationships ranged from 53.0 to 160.0 mmHg/cm and from 97.0 to 195.0 g/cm3, respectively.4. The end-systolic LV pressure-diameter and stress-diameter relationship lines presented high and variable slopes. The slopes, which are indicators of myocardial contractility, are susceptible to modifications by small deviations in the measurement of the ventricular diameter or by delay in the pressure curve recording.