985 resultados para Conjugate gradient methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. Coronary MDCT angiography has been shown to be an accurate noninvasive tool for the diagnosis of obstructive coronary artery disease (CAD). Its sensitivity and negative predictive value for diagnosing percentage of stenosis are unsurpassed compared with those of other noninvasive testing methods. However, in its current form, it provides no information regarding the physiologic impact of CAD and is a poor predictor of myocardial ischemia. CORE320 is a multicenter multinational diagnostic study with the primary objective to evaluate the diagnostic accuracy of 320-MDCT for detecting coronary artery luminal stenosis and corresponding myocardial perfusion deficits in patients with suspected CAD compared with the reference standard of conventional coronary angiography and SPECT myocardial perfusion imaging. CONCLUSION. We aim to describe the CT acquisition, reconstruction, and analysis methods of the CORE320 study.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Minimal perfect hash functions are used for memory efficient storage and fast retrieval of items from static sets. We present an infinite family of efficient and practical algorithms for generating order preserving minimal perfect hash functions. We show that almost all members of the family construct space and time optimal order preserving minimal perfect hash functions, and we identify the one with minimum constants. Members of the family generate a hash function in two steps. First a special kind of function into an r-graph is computed probabilistically. Then this function is refined deterministically to a minimal perfect hash function. We give strong theoretical evidence that the first step uses linear random time. The second step runs in linear deterministic time. The family not only has theoretical importance, but also offers the fastest known method for generating perfect hash functions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A single-beam gradient trap could potentially be used to hold a stylus for scanning force microscopy. With a view to development of this technique, we modeled the optical trap as a harmonic oscillator and therefore characterized it by its force constant. We measured force constants and resonant frequencies for 1-4-mu m-diameter polystyrene spheres in a single-beam gradient trap using measurements of back-scattered light. Force constants were determined with both Gaussian and doughnut laser modes, with powers of 3 and 1 mW, respectively. Typical values for spring constants were measured to be between 10(-6) and 4 x 10(-6) N/m. The resonant frequencies of trapped particles were measured to be between 1 and 10 kHz, and the rms amplitudes of oscillations were estimated to be around 40 nm. Our results confirm that the use of the doughnut mode for single-beam trapping is more efficient in the axial direction. (C) 1996 Optical Society of America.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Little consensus exists in the literature regarding methods for determination of the onset of electromyographic (EMG) activity. The aim of this study was to compare the relative accuracy of a range of computer-based techniques with respect to EMG onset determined visually by an experienced examiner. Twenty-seven methods were compared which varied in terms of EMG processing (low pass filtering at 10, 50 and 500 Hz), threshold value (1, 2 and 3 SD beyond mean of baseline activity) and the number of samples for which the mean must exceed the defined threshold (20, 50 and 100 ms). Three hundred randomly selected trials of a postural task were evaluated using each technique. The visual determination of EMG onset was found to be highly repeatable between days. Linear regression equations were calculated for the values selected by each computer method which indicated that the onset values selected by the majority of the parameter combinations deviated significantly from the visually derived onset values. Several methods accurately selected the time of onset of EMG activity and are recommended for future use. Copyright (C) 1996 Elsevier Science Ireland Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study investigated the effect of two anti-pronation taping techniques on vertical navicular height, an indicator of foot pronation, after its application and 20 min of exercise. The taping techniques were: the low dye (LD) and low dye with the addition of calcaneal slings and reverse sixes (LDCR). A repeated measures study was used. It found that LDCR was superior to LD and control immediately after application and exercise. LD was better than control immediately after application but not after exercise. These findings provide practical directions to clinicians regularly using anti-pronation taping techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction. Advantages of the bicaval versus the biatrial technique have been reported, emphasizing atrial electrical stability and less tricuspid regurgitation. Objective. To analyze the impact of the surgical technique on long-term pulmonary pressures, contractility, and graft valvular behavior after heart transplantation. Methods. Among 400 orthotopic heart transplantation recipients from 1985 to 2010, we selected 30 consecutive patients who had survived beyond 3 years. The biatrial versus bicaval surgical technique groups included 15 patients each. Their preoperative clinical characteristics were similar. None of the patients displayed a pulmonary vascular resistance or pulmonary artery pressure over 6U Wood or 60 mm Hg, respectively. We evaluated invasive hemodynamic parameters during routine endomyocardial biopsies. Two-dimensional echocardiographic parameters were obtained from routine examinations. Results. There were no significant differences regarding right atrial pressure, systolic pulmonary artery pressure, pulmonary capillary wedge pressure, pulmonary vascular resistance, cardiac index, systolic blood pressure, left ventricular ejection fraction, and mitral regurgitation (P > .05). Tricuspid regurgitation increased significantly over the 3 years of observation only among the biatrial group (P = .0212). In both groups, the right atrial pressure, pulmonary wedge capillary pressure, transpulmonary gradient, and pulmonary vascular resistance decreased significantly (P < .05) from the pre- to the postoperative examination. In both groups cardiac index and systemic blood pressure increased significantly after transplantation (P < .05). Comparative analysis of the groups only showed significant differences regarding right atrial pressure and degree of tricuspid regurgitation; the bicaval group showing the best performance. Conclusions. Both surgical techniques ensure adequate left ventricular function in the long term; however, the bicaval technique provided better trends in hemodynamic performance, as well as a lower incidence and severity of tricuspid valve dysfunction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Acute mesenteric ischemia is a potentially fatal vascular emergency with mortality rates ranging between 60% and 80%. Several studies have extensively examined the hemodynamic and metabolic effects of superior mesenteric artery occlusion. On the other hand, the cardiocirculatory derangement and the tissue damage induced by intestinal outflow obstruction have not been investigated systematically. For these reasons we decided to assess the initial impact of venous mesenteric occlusion on intestinal blood flow distribution, and correlate these findings with other systemic and regional perfusion markers. Methods. Fourteen mongrel dogs were subjected to 45 min of superior mesenteric artery (SMAO) or vein occlusion (SMVO), and observed for 120 min after reperfusion. Systemic hemodynamics were evaluated using Swan-Ganz and arterial catheters. Regional blood flow (ultrasonic flow probes), intestinal O(2)-derived variables, and mesenteric-arterial and tonometric-arterial pCO(2) gradients (D(mv-a)pCO(2) and D(t-a)pCO(2)) were also calculated. Results. SMVO was associated with hypotension and low cardiac output. A significant increase in the regional pCO(2) gradients was also observed in both groups during the ischemic period. After reperfusion, a progressive reduction in D(mv-a)pCO(2) occurred in the SMVO group; however, no improvement in D(t-p)CO(2) was observed. The histopathologic injury scores were 2.7 +/- 0.5 and 4.8 +/- 0.2 for SMAO and SMVO, respectively. Conclusions. SMV occlusion promoted early and significant hemodynamic and metabolic derangement at systemic and regional levels. Additionally, systemic pCO(2) gradient is not a reliable parameter to evaluate the local intestinal oxygenation. Finally, the D(t-a)pCO(2) correlates with histologic changes during intestinal congestion or ischemia. However, minor histologic changes cannot be detected using this methodology. (C) 2010 Elsevier Inc. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Protein purification that combines the use of molecular mass exclusion membranes with electrophoresis is particularly powerful as it uses properties inherent to both techniques. The use of membranes allows efficient processing and is easily scaled up, while electrophoresis permits high resolution separation under mild conditions. The Gradiflow apparatus combines these two technologies as it uses polyacrylamide membranes to influence electrokinetic separations. The reflux electrophoresis process consists of a series of cycles incorporating a forward phase and a reverse phase. The forward phase involves collection of a target protein that passes through a separation membrane before trailing proteins in the same solution. The forward phase is repeated following clearance of the membrane in the reverse phase by reversing the current. We have devised a strategy to establish optimal reflux separation parameters, where membranes are chosen for a particular operating range and protein transfer is monitored at different pH values. In addition, forward and reverse phase times are determined during this process. Two examples of the reflux method are described. In the first case, we describe the purification strategy for proteins from a complex mixture which contains proteins of higher electrophoretic mobility than the target protein. This is a two-step procedure, where first proteins of higher mobility than the target protein are removed from the solution by a series of reflux cycles, so that the target protein remains as the leading fraction. In the second step the target protein is collected, as it has become the leading fraction of the remaining proteins. In the second example we report the development of a reflux strategy which allowed a rapid one-step preparative purification of a recombinant protein, expressed in Dictyostelium discoideum. These strategies demonstrate that the Gradiflow is amenable to a wide range of applications, as the protein of interest is not necessarily required to be the leading fraction in solution. (C) 1997 Elsevier Science B.V.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here, we examine morphological changes in cortical thickness of patients with Alzheimer`s disease (AD) using image analysis algorithms for brain structure segmentation and study automatic classification of AD patients using cortical and volumetric data. Cortical thickness of AD patients (n = 14) was measured using MRI cortical surface-based analysis and compared with healthy subjects (n = 20). Data was analyzed using an automated algorithm for tissue segmentation and classification. A Support Vector Machine (SVM) was applied over the volumetric measurements of subcortical and cortical structures to separate AD patients from controls. The group analysis showed cortical thickness reduction in the superior temporal lobe, parahippocampal gyrus, and enthorhinal cortex in both hemispheres. We also found cortical thinning in the isthmus of cingulate gyrus and middle temporal gyrus at the right hemisphere, as well as a reduction of the cortical mantle in areas previously shown to be associated with AD. We also confirmed that automatic classification algorithms (SVM) could be helpful to distinguish AD patients from healthy controls. Moreover, the same areas implicated in the pathogenesis of AD were the main parameters driving the classification algorithm. While the patient sample used in this study was relatively small, we expect that using a database of regional volumes derived from MRI scans of a large number of subjects will increase the SVM power of AD patient identification.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. The objective of our study was to describe the T1 and T2 signal intensity characteristics of papillary renal cell carcinoma (RCC) and clear cell RCC with pathologic correlation. MATERIALS AND METHODS. Of 539 RCCs, 49 tumors (21 papillary RCCs and 28 clear cell RCCs) in 45 patients were examined with MRI. Two radiologists retrospectively and independently assessed each tumor`s T1 and T2 signal intensity qualitatively and quantitatively (i.e., the signal intensity [SI] ratio [tumor SI/renal cortex SI]). Of the 49 tumors, 37 (76%) were assessed for pathology features including tumor architecture and the presence of hemosiderin, ferritin, necrosis, and fibrosis. MRI findings and pathology features were correlated. Statistical methods included summary statistics and Wilcoxon`s rank sum test for signal intensity, contingency tables for assessing reader agreement, concordance rate between the two readers with 95% CIs, and Fisher`s exact test for independence, all stratified by RCC type. RESULTS. Papillary RCCs and clear cell RCCs had a similar appearance and signal intensity ratio on T1-weighted images. On T2-weighted images, most papillary RCCs were hypointense (reader 1, 13/21; reader 2, 14/21), with an average mean signal intensity ratio for both readers of 0.67 +/- 0.2, and none was hyperintense, whereas most clear cell RCCs were hyperintense (reader 1, 21/28; reader 2, 17/28), with an average mean signal intensity ratio for both readers of 1.41 +/- 0.4 (p < 0.05). A tumor T2 signal intensity ratio of <= 0.66 had a specificity of 100% and sensitivity of 54% for papillary RCC. Most T2 hypointense tumors exhibited predominant papillary architecture; most T2 hyperintense tumors had a predominant nested architecture (p < 0.05). CONCLUSION. On T2-weighted images, most papillary RCCs are hypointense and clear cell RCCs, hyperintense. The T2 hypointense appearance of papillary RCCs correlated with a predominant papillary architecture at pathology.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have previously shown that H-1 pulsed-field-gradient (PFG) NMR spectroscopy provides a facile method for monitoring protein self-association and can be used, albeit with some caveats, to measure the apparent molecular mass of the diffusant [Dingley et al. (1995) J. Biomol. NMR, 6, 321-328]. In this paper we show that, for N-15-labelled proteins, selection of H-1-N-15 multiple-quantum (MQ) coherences in PFG diffusion experiments provides several advantages over monitoring H-1 single-quantum (SQ) magnetization. First, the use of a gradient-selected MQ filter provides a convenient means of suppressing resonances from both the solvent and unlabelled solutes. Second, H-1-N-15 zero-quantum coherence dephases more rapidly than H-1 SQ coherence under the influence of a PFG. This allows the diffusion coefficients of larger proteins to be measured more readily. Alternatively, the gradient length and/or the diffusion delay may be decreased, thereby reducing signal losses from relaxation. In order to extend the size of macromolecules to which these experiments can be applied, we have developed a new MQ PFG diffusion experiment in which the magnetization is stored as longitudinal two-spin order for most of the diffusion period, thus minimizing sensitivity losses due to transverse relaxation and J-coupling evolution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pneumococcal vaccination has been recommended for immunocompromised children, including patients with chronic kidney disease. We determined pneumococcal immunoglobulin (Ig) G antibodies to serotypes 4, 6B, 9V, 14, 18C, 19F, and 23F before and after 48 pediatric patients with chronic renal failure were administered heptavalent conjugated pneumococcal vaccine. The patients were between 1 and 9 years of age and were separated into a conservative treatment group (Group 1) and a dialysis group Group 2). The antibody response to the vaccinal serotypes was evaluated by measuring antibody concentrations before the first dose and 60 days after the second one. Pre-vaccinal IgG concentrations >= 0.35 mu g/ml were detected for all serotypes in at least 50% of the patients in both groups. Patients from both groups showed a statistically indistinguishable behavior in terms of the medians of post-vaccination IgG levels. An ""adequate"" vaccine response was defined as a post-immunization level of specific pneumococcal serotype antibody >= 0.35 mu g/ml, based on the World Health Organization`s (WHO) protective antibody concentration definition for pneumococcal conjugate vaccines, or on a fourfold increase over baseline for at least five of the seven antigens of the vaccine. An ""adequate"" vaccinal response was obtained in 100% of the patients of both groups using WHO`s definition, or in 45.8% of Group 1 patients and 37.5% of Group 2 patients when the criterion was a fourfold antibody increase over baseline antibody concentrations.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and objective: Light`s criteria are frequently used to evaluate the exudative or transudative nature of pleural effusions. However, misclassification resulting from the use of Light`s criteria has been reported, especially in the setting of diuretic use in patients with heart failure (HF). The objective of this study was to evaluate the utility of B-type natriuretic peptide (BNP) measurements as a diagnostic tool for determining the cardiac aetiology of pleural effusions. Methods: Patients with pleural effusions attributable to HF (n = 34), hepatic hydrothorax (n = 10), pleural effusions due to cancer (n = 21) and pleural effusions due to tuberculosis (n = 12) were studied. Diagnostic thoracentesis was performed for all 77 patients. Receiver operating characteristic (ROC) curves were constructed to determine the diagnostic accuracy of plasma BNP and pleural fluid BNP for the prediction of HF. Results: The areas under the ROC curves were 0.987 (95% CI 0.93-0.998) for plasma BNP and 0.949 (95% CI 0.874-0.986) for pleural fluid BNP, for distinguishing between patients with pleural effusions caused by HF (n = 34) and those with pleural effusions attributable to other causes (n = 43). The cut-off concentrations with the highest diagnostic accuracy for the diagnosis of HF as the cause of pleural effusion were 132 pg/mL for plasma BNP (sensitivity 97.1%, specificity 97.4%) and 127 pg/mL for pleural fluid BNP (sensitivity 97.1%, specificity 87.8%). Conclusions: In patients with pleural effusions of suspected cardiac origin, measurements of BNP in plasma and pleural fluid may be useful for the diagnosis of HF as the underlying cause.