932 resultados para Complications: accidental injection
Resumo:
Objective: To compare multidetector-row computed tomographic (MDCT) enterography with magnetic resonance (MR) enterography performed upon acute exacerbation of Crohn's disease. Subjects and Methods: Fifty-seven patients (mean age 33.5) with proven Crohn's disease and symptoms suggesting acute exacerbation were prospectively included. After oral administration of 1-2 liters of 5% methylcellulose, MDCT and MR enterography were performed on each patient (mean delay <24 h). Three radiologists blindly and independently evaluated each examination for technical quality and in terms of 8 pathological features of Crohn's disease. Observers' agreement, sensitivity and specificity resulted from comparison with the reference standard [surgery (n = 24), endoscopy (n = 17) and long-term follow-up (n = 16)]. Results: MDCT enterography demonstrated fewer artifacts than MR enterography (p < 0.0001). In 48 MDCT/MR enterography examinations, active disease was demonstrated: abscesses (n = 11), fistulas (n = 13), stenoses (n = 23) and/or intestinal inflammation (n = 38). Observers' agreement (range 0.56-0.87) was not significantly different between MDCT and MR enterography, neither in terms of sensitivity (range 58-95%) nor specificity (range 67-100%) for each of the 8 pathological features. Conclusion: Statistically, MR enterography is of similar diagnostic value as MDCT enterography for acute complications of Crohn's disease. Since the typical Crohn's disease patient is young and will very likely undergo life-long imaging, and given concerns about radiation exposure with MDCT, MR enterography should be the preferred modality.
Resumo:
This work presents an alternative to generate continuous phase shift of sinusoidal signals based on the use of super harmonic injection locked oscillators (ILO). The proposed circuit is a second harmonic ILO with varactor diodes as tuning elements. In the locking state, by changing the varactor bias, a phase shift instead of a frequency shift is observed at the oscillator output. By combining two of these circuits, relative phases up to 90 could be achieved. Two prototypes of the circuit have been implemented and tested, a hybrid version working in the range of 200-300 MHz and a multichip module (MCM) version covering the 900¿1000 MHz band.
Resumo:
This paper presents a new method and circuit for the conversion of binary phase-shift keying (BPSK) signals into amplitude shift keying signals. The basic principles of the conversion method are the superharmonic injection and locking of oscillator circuits, and interference phenomena. The first one is used to synchronize the oscillators, while the second is used to generate an amplitude interference pattern that reproduces the original phase modulation. When combined with an envelope detector, the proposed converter circuit allows the coherent demodulation of BPSK signals without need of any explicit carrier recovery system. The time response of the converter circuit to phase changes of the input signal, as well as the conversion limits, are discussed in detail.
Resumo:
This paper demonstrates the feasibility of a new circuit for the conversion of binary phase-shift keying signals into amplitude-shift keying signals. In its simplest form, the converter circuit is composed by a power divider, a couple of second harmonic injection-locked oscillators, and a power combiner. The operation of the converter circuit relies on the frequency synchronization of both oscillators and the generation of an interference pattern by combining their outputs, which reproduces the original phase modulation. Two prototypes of the converter have been implemented. The first one is a hybrid version working in the 400-530-MHz frequency range. The second one has been implemented using multichip-module technology, and is intended to work in the 1.8-2.2-GHz frequency range.
Resumo:
Purpose: Fluoroscopy-guided sacroiliac joint (SIJ) injections are technically difficult to perform because of the complex anatomy with helicoidal conformation of the joint. Our study describes the procedure of CT-guided SIJ injection, its feasibility and its rate of success. Methods and materials: Retrospective study included 46 consecutive patients. The procedure was performed by 3 MSK radiologists and consisted in a puncture with a posterior approach in the inferior articular part of SIJ, then in an injection of iodinated contrast agent (1ml) with CT control of SIJ space opacification and finally in an injection of slowacting corticosteroid. The SIJ approach was noticed as correct if there was an inferior articular puncture and if the needle was in the articular space, and as impossible if there was ankylosis or osteophytosis. The study was divided in two successive periods: period 1 (4 first months) and period 2 (12 last months). Results: SIJ opacification was successful in 57% (26/46). We observed a learning curve: opacification was succeeded in 66% (23/35) and there was incorrect approach in 9% (3/35) during period 2 versus respectively 27% (3/11) and 45% (5/11) during period 1. Causes of failure were incorrect approach in 40% (6/20 too low, 2/20 too high), impossible approach in 30% (6/20) and unexplained in 30% (6/20). Mean duration of procedure was about 28 minutes. No complication occurred. Conclusion: CT guided SIJ injection is safe and successful in 66% after a training period. The success depends on SIJ correct approach and also on anatomical lesions.
Resumo:
OBJECTIVE: Intravenous methadone is associated with increased risk of morbidity and mortality. A previous report from a methadone center in Fribourg, Switzerland, found a high prevalence (43%) of patients who injected oral methadone. We therefore wished to assess the prevalence of methadone injection among patients in oral methadone programs in 3 other Swiss cities--Lausanne, Geneva, and La Chaux-de-Fonds. METHOD: Subjects were randomly selected and interviewed by assistant psychologists who were not on the staff of the study centers. Participation was voluntary and anonymous. RESULTS: 164 patients participated in the study (n = 58 in Lausanne, 52 in Geneva, and 54 in La Chaux-de-Fonds). The prevalence of methadone injection was low (5%) and did not differ significantly between the cities. DISCUSSION: Less liberal policies cannot explain the lower prevalence of methadone injection in these three centers than in Fribourg. The high prevalence of methadone injection there is probably related to its separate methadone injection program: patients in oral methadone programs may be more likely to injection methadone when other patients authorized to do so. IN CONCLUSION: Although the 5% prevalence of methadone injection found in the 3 cities surveyed is low, it is not negligible. These results suggest that information on the risks associated with injection of methadone syrup should be provided to all methadone maintenance. This information is especially necessary when maintenance therapy is provided in the same center, or city as injectable methadone maintenance.
Resumo:
In this study, we investigated the effect of the xanthine oxidase (XO) inhibitor, allopurinol (ALP), on cardiac dysfunction, oxidative-nitrosative stress, apoptosis, poly(ADP-ribose) polymerase (PARP) activity and fibrosis associated with diabetic cardiomyopathy in mice. Diabetes was induced in C57/BL6 mice by injection of streptozotocin. Control and diabetic animals were treated with ALP or placebo. Left ventricular systolic and diastolic functions were measured by pressure-volume system 10 weeks after established diabetes. Myocardial XO, p22(phox), p40(phox), p47(phox), gp91(phox), iNOS, eNOS mRNA and/or protein levels, ROS and nitrotyrosine (NT) formation, caspase3/7 and PARP activity, chromatin fragmentation and various markers of fibrosis (collagen-1, TGF-beta, CTGF, fibronectin) were measured using molecular biology and biochemistry methods or immunohistochemistry. Diabetes was characterized by increased myocardial, liver and serum XO activity (but not expression), increased myocardial ROS generation, p22(phox), p40(phox), p47(phox), p91(phox) mRNA expression, iNOS (but not eNOS) expression, NT generation, caspase 3/7 and PARP activity/expression, chromatin fragmentation and fibrosis (enhanced accumulation of collagen, TGF-beta, CTGF and fibronectin), and declined systolic and diastolic myocardial performance. ALP attenuated the diabetes-induced increased myocardial, liver and serum XO activity, myocardial ROS, NT generation, iNOS expression, apoptosis, PARP activity and fibrosis, which were accompanied by improved systolic (measured by the evaluation of both load-dependent and independent indices of myocardial contractility) and diastolic performance of the hearts of treated diabetic animals. Thus, XO inhibition with ALP improves type 1 diabetes-induced cardiac dysfunction by decreasing oxidative/nitrosative stress and fibrosis, which may have important clinical implications for the treatment and prevention of diabetic cardiomyopathy and vascular dysfunction.
Resumo:
BACKGROUND: The aim of this communication is to describe an unusual and serious complication of retrobulbar anaesthesia for cataract surgery. HISTORY AND SIGNS: A 78-year-old female was referred for visual loss (light perception) 24 hours after apparently uneventful cataract surgery with retrobulbar anaesthesia in her left eye. Fundus examination revealed multiple arterial emboli and a localised retinal detachment. MRI revealed a retrobulbar hypersignal of the optic nerve associated with perineuritis. The cardiovascular examination was normal. We assumed this condition resulted from injection of the anaesthetic mixture into the optic nerve. THERAPY AND OUTCOME: In order to improve retinal circulation and oxygenation, the intraocular pressure was maximally lowered and anticalcic therapy administered, expecting optimal arterial dilatation. Methylprednisolone (1 g/day 3 days i. v., then rapidly tapered) was also added. The retina slowly reattached but visual acuity remained unchanged. CONCLUSIONS: Retrobulbar anaesthesia is routinely used for ocular surgery. Serious complications may still happen, however. This case adds to the previously reported spectrum of complications from retrobulbar anaesthesia.
Resumo:
Objectif : Comparer les hystérectomies réalisées par laparoscopie à celles accomplies par laparotomie pour des pathologies gynécologiques malignes. Méthode : Etude basée sur 169 hystérectomies effectuées pour cancer de l'endomètre, du col ou de l'ovaire, pratiquées dans le service de gynécologie de la Maternité du CHUV de janvier 2002 à décembre 2009 sur des femmes âgées de 28 à 91 ans. Le but est de comparer deux différentes voies d'abord chirurgicales qui sont la laparotomie et la laparoscopie en terme de durée d'hospitalisation, d'indications, de complications per et post opératoires mineures et majeures et de nécessité de reprise ou d'une ré-hospitalisation. Résultats: Cette étude compte 169 patientes, dont 126 hystérectomies réalisées par laparotomie et 43 accomplies par laparoscopie. Les deux groupes sont similaires en terme d'âge (âge moyen : 63ans), d'indice de masse corporelle (26 vs 25) et de parité (1.5 enfants). Le temps opératoire est semblable entre les deux groupes (211 vs 219 minutes). Des hémorragies (pertes sanguines de plus de 1000ml) surviennent dans 24.6% des hystérectomies par laparotomie et dans 11.63% des hystérectomies par laparoscopie. Il existe une différence statistiquement significative entre la nécessité d'une transfusion peropératoire et les deux différentes voie d'abord (p=0.045). Une transfusion peropératoire a été nécessaire dans 13.22% des laparotomies contre seulement 2.33% des laparoscopies. La durée d'hospitalisation est significativement plus longue pour les patientes ayant subi une hystérectomie par laparotomie (12 vs 6 jours; p<0.001). Les complications peropératoires et postopératoires mineures dépendent de manière significative de la voie d'abord (p=0.01 ; p= 0.025). On observe des complications peropératoires dans 31.75% des laparotomies et dans 11.63% des laparoscopies. Les complications postopératoires mineures sont observées dans 28.57% des laparotomies et dans 11.63% des laparoscopies. Dans 7.14% des laparotomies on observe une complications postopératoire majeure et aucune de sont apparues lors d'hystérectomie par laparoscopie. La nécessité de reprise, de ré-opération ou de ré-hospitalisation n'est statistiquement pas différente entre la laparoscopie et la laparotomie. Conclusion : On observe un avantage significatif en faveur de l'hystérectomie par laparoscopie avec une réduction de la durée d'hospitalisation, ainsi que des complications peropératoires et postopératoires mineures et majeures, moins importantes.
Resumo:
The frequency dynamics of gain-switched singlemode semiconductor lasers subject to optical injection is investigated. The requirements for low time jitter and reduced frequency chirp operation are studied as a function of the frequency mismatch between the master and slave lasers. Suppression of the power overshoot, typical during gain-switched operation, can be achieved for selected frequency detunings.
Resumo:
This clinical study was based on experimental results obtained in nude mice grafted with human colon carcinoma, showing that injected 131I-labeled F(ab')2 and Fab fragments from high affinity anti-carcinoembryonic antigen (CEA) monoclonal antibodies (MAb) gave markedly higher ratios of tumor to normal tissue localization than intact MAb. 31 patients with known colorectal carcinoma, including 10 primary tumors, 13 local tumor recurrences, and 21 metastatic involvements, were injected with 123I-labeled F(ab')2 (n = 14) or Fab (n = 17) fragments from MAb anti-CEA. The patients were examined by emission-computerized tomography (ECT) at 6, 24, and sometimes 48 h after injection using a rotating dual head scintillation camera. All 23 primary tumors and local recurrences except one were clearly visualized on at least two sections of different tomographic planes. Interestingly, nine of these patients had almost normal circulating CEA levels, and three of the visualized tumors weighed only 3-5 g. Among 19 known metastatic tumor involvements, 14 were correctly localized by ECT. Two additional liver and several bone metastases were discovered by immunoscintigraphy. Altogether, 86% of the tumor sites were detected, 82% with F(ab')2 and 89% with Fab fragments. The contrast of the tumor images obtained with Fab fragments suggests that this improved method of immunoscintigraphy has the potential to detect early tumor recurrences and thus to increase the survival of patients. The results of this retrospective study, however, should be confirmed in a prospective study before this method can be recommended for the routine diagnosis of cancer.
Resumo:
The rate of carbon dioxide production is commonly used as a measure of microbial activity in the soil. The traditional method of CO2 determination involves trapping CO2 in an alkali solution and then determining CO2 concentration indirectly by titration of the remaining alkali in the solution. This method is still commonly employed in laboratories throughout the world due to its relative simplicity and the fact that it does not require expensive, specific equipment. However, there are several drawbacks: the method is time-consuming, requires large amounts of chemicals and the consistency of results depends on the operator's skills. With this in mind, an improved method was developed to analyze CO2 captured in alkali traps, which is cheap and relatively simple, with a substantially shorter sample handling time and reproducibility equivalent to the traditional titration method. A comparison of the concentration values determined by gas phase flow injection analysis (GPFIA) and titration showed no significant difference (p > 0.05), but GPFIA has the advantage that only a tenth of the sample volume of the titration method is required. The GPFIA system does not require the purchase of new, costly equipment but the device was constructed from items commonly found in laboratories, with suggestions for alternative configurations for other detection units. Furthermore, GPFIA for CO2 analysis can be equally applied to samples obtained from either the headspace of microcosms or from a sampling chamber that allows CO2 to be released from alkali trapping solutions. The optimised GPFIA method was applied to analyse CO2 released from degrading hydrocarbons from a site contaminated by diesel spillage.