967 resultados para Cavità Laser Fabry-Perot FEA Rumori Simulazione
Resumo:
A technique based on laser light diffraction is shown to be successful in collecting on-line experimental data. Time series of floc size distributions (FSD) under different shear rates (G) and calcium additions were collected. The steady state mass mean diameter decreased with increasing shear rate G and increased when calcium additions exceeded 8 mg/l. A so-called population balance model (PBM) was used to describe the experimental data, This kind of model describes both aggregation and breakage through birth and death terms. A discretised PBM was used since analytical solutions of the integro-partial differential equations are non-existing. Despite the complexity of the model, only 2 parameters need to be estimated: the aggregation rate and the breakage rate. The model seems, however, to lack flexibility. Also, the description of the floc size distribution (FSD) in time is not accurate.
Resumo:
A range of lasers. is now available for use in dentistry. This paper summarizes key current and emerging applications, for lasers in clinical practice. A major diagnostic application of low power lasers is the detection of caries, using fluorescence elicited from hydroxyapatite or from bacterial by-products. Laser fluorescence is an effective method for detecting and quantifying incipient occlusal and cervical,carious lesions, and with further refinement could be used in the, same manner for proximal lesions. Photoactivated dye techniques have been developed which use low power lasers to elicit a photochemical reaction, Photoactivated dye techniques' can be used to disinfect root canals, periodontal pockets, cavity preparations and sites of peri-implantitis. Using similar principles, more powerful lasers tan be used for photodynamic therapy in the treatment of malignancies of the oral mucosa. Laser-driven photochemical reactions can also be used for tooth whitening. In combination with fluoride, laser irradiation can improve the resistance of tooth structure to demineralization, and this application is of particular benefit for susceptible sites in high caries risk patients. Laser technology for caries' removal, cavity preparation and soft tissue surgery is at a high state of refinement, having had several decades of development up to the present time. Used in conjunction with or as a replacement for traditional methods, it is expected that specific laser technologies will become an essential component of contemporary dental practice over the next decade.
Resumo:
In order to develop a method for use in investigations of spatial biomass distribution in solid-state fermentation systems, confocal scanning laser microscopy was used to determine the concentrations of aerial and penetrative biomass against height and depth above and below the substrate surface, during growth of Rhizopus oligosporus on potato dextrose agar. Penetrative hyphae had penetrated to a depth of 0.445 cm by 64 h and showed rhizoid morphology, in which the maximum biomass concentration, of 4.45 mg dry wt cm(-3), occurred at a depth of 0.075 cm. For aerial biomass the maximum density of 39.54 mg dry wt(-3) occurred at the substrate surface. For both aerial and penetrative biomass, there were two distinct regions in which the biomass concentration decayed exponentially with distance from the surface. For aerial biomass, the first exponential decay region was up to 0.1 cm height. The second region above the height of 0.1 cm corresponded to that in which sporangiophores dominated. This work lays the foundation for deeper studies into what controls the growth of fungal hyphae above and below the surfaces of solid substrates. (C) Wiley Periodicals, Inc.
Resumo:
We present the quantum theory of the far-off-resonance continuous-wave Raman laser using the Heisenberg-Langevin approach. We show that the simplified quantum Langevin equations for this system are mathematically identical to those of the nondegenerate optical parametric oscillator in the time domain with the following associations: pump pump, Stokes signal, and Raman coherence idler. We derive analytical results for both the steady-state behavior and the time-dependent noise spectra, using standard linearization procedures. In the semiclassical limit, these results match with previous purely semiclassical treatments, which yield excellent agreement with experimental observations. The analytical time-dependent results predict perfect photon statistics conversion from the pump to the Stokes and nonclassical behavior under certain operational conditions.
Resumo:
Onicomicose é a doença ungueal mais frequente, com prevalência estimada entre 2 e 8% da população. As estratégias de tratamentos atuais incluem uso de antifúngicos tópicos e orais, ambos geralmente com baixos índices de cura. Os objetivos deste estudo foram avaliar a resposta terapêutica ao laser Nd:YAG 1.064 nm no tratamento da onicomicose, bem como o método de avaliação clínica dessa terapia e os possíveis efeitos colaterais de seu uso. Foram revisados prontuários de 20 pacientes submetidos à laserterapia. Ao todo, 34 unhas afetadas foram avaliadas de acordo com o Índice de Severidade de Onicomicose (ISO). Esse índice analisa a área de envolvimento da unha, a proximidade da doença com a matriz ungueal, a ocorrência de dermatofitoma e a presença de hiperqueratose subungueal > 2 mm, gerando uma pontuação que classifica a onicomicose como leve, moderada ou grave. A determinação do ISO foi realizada antes do tratamento e após um período de acompanhamento, em média, de oito meses. A comparação entre o ISO Inicial e o ISO Final nas 34 unhas submetidas à laserterapia mostrou diferença significativa, porém, com baixa associação entre essas variáveis. Com relação à área de envolvimento e à pontuação numérica referente ao ISO, houve, no geral, uma redução dessas medidas. Esses dados apontam para uma tendência à melhora da onicomicose por meio do tratamento com o laser Nd:YAG 1.064 nm. O ISO permitiu uma análise clínica adequada da resposta à laserterapia. Os efeitos colaterais locais apresentados durante a aplicação do laser não causaram desconforto acentuado na maioria dos pacientes, demonstrando que o procedimento é bem tolerado.
Resumo:
OBJETIVO: Avaliar a voz de pacientes portadores de carcinomas iniciais glóticos submetidos à cordectomia com laser de CO2. MÉTODO: Foram avaliados 15 pacientes com diagnóstico de carcinoma espinocelular Tis e T1 glóticos. A avaliação foi feita por meio da análise perceptivo auditiva da voz, pela análise acústica computadorizada e videolaringoestroboscópica. Os pacientes responderam a um questionário de avaliação geral da voz e um protocolo de qualidade de vida relacionado à voz (QVV). Os resultados foram comparados aos de um grupo controle de indivíduos com laringes normais. RESULTADOS: A análise perceptivo-auditiva da voz revelou que a maioria dos pacientes submetidos à cordectomia apresentou algum grau de disfonia, à custa de rouquidão e soprosidade. Considerando os parâmetros acústicos analisados e os valores do grupo controle, observou-se a tendência de um pequeno incremento da freqüência fundamental, mas sem diferença estatisticamente significante; os valores de jitter, shimmer e da proporção harmônico-ruído apresentaram-se significantemente alterados. Os aspectos analisados na videolaringoestroboscopia mostraram-se melhores nas cordectomias menos extensas. Os escores do QVV sugerem que os pacientes tiveram um discreto impacto na qualidade de vida relacionada à voz. CONCLUSÕES: Apesar da presença de alterações na qualidade vocal dos pacientes submetidos à cordectomia com laser de CO2, os resultados funcionais tendem a ser bem aceitos pelos pacientes, com discreta repercussão na qualidade de vida.
Resumo:
Otite média secretora (OMS) e otite média aguda recorrente (OMAR) podem necessitar tratamento cirúrgico para adequada ventilação da orelha média. A abertura clássica do tímpano (timpanocentese) requer incisão por microlanceta sob controle de microscópio cirúrgico e mantém-se patente por alguns dias. Estudos recentes sugerem que a timpanocentese feita por diferentes lasers pode permanecer permeável por maior tempo, o que possibilitaria a normalização da otite média. MATERIAL E MÉTODOS: Neste estudo experimental 34 ratos linhagem Wistar, albinos, machos adultos pesando cerca de 300g, foram anestesiados com cetamina 27 mg/kg e xilazina 2,7 mg/kg. A seguir, foram submetidos à timpanocentese incisional com microlanceta no ouvido direito (ML-OD), e à timpanocentese mediada por laser de argônio no ouvido esquerdo (LA-OE). RESULTADOS: Não houve diferença significativa no tempo de cicatrização das timpanocenteses feitas com laser de argônio ou microlanceta. Todas as timpanocenteses cicatrizaram em 10 dias. CONCLUSÃO: A timpanocentese com laser de argônio apresentou patência e cicatrização semelhantes à técnica clássica com microlanceta realizada em ratos Wistar sem enfermidades de orelha média.
Resumo:
The wettability of polyimide surfaces microstructured using KrF laser radiation at fluences above the material ablation threshold was studied by static contact angle measurements. The laser-treated surfaces present a morphology consisting of conical features whose dimensions and areal density depend on the fluence. The effect of these parameters on the surface apparent contact angle depends on the wetting regime. When wetting occurs in the homogeneous regime, the apparent contact angle of the treated surfaces increases with the radiation fluence because the cone dimensions increase. In contrast, when wetting occurs in the heterogeneous regime, the apparent contact angle increases with the radiation fluence because the average distance between cones increases. The apparent water contact angle of the laser-treated surfaces can reach values as high as 162 degrees, as compared to 75 degrees for virgin polyimide.
Resumo:
The evolution of the topography of titanium surfaces treated with femtosecond laser radiation in stationary conditions as a function of radiation fluence and number of laser pulses is investigated. Depending on the processing parameters, ripples, microcolumns, wavy or smooth surfaces can be obtained. The ripples predominate for fluences near the damage threshold of titanium (0.2+/-0.1) J/cm(2), while microcolumns form during the first 200 pulses for fluences between (0.6+/-0.2) and (1.7+/-0.2) J/cm(2). A wavy topography develops for fluences and number of pulses higher than (1.7+/-0.2) J/cm(2) and 300, respectively. A bimodal surface topography consisting of surface ripples overlapping a microcolumnar topography can be obtained if the surfaces are firstly treated to create microcolumns followed by laser treatment with a lower fluence near the ablation threshold of the material, in order to generate periodic ripple
Resumo:
Esta dissertação surgiu com o objectivo de se criar uma base de dados de Toners para impressoras e fotocopiadoras e um método fiável de comparação de espectros para estudos forenses e de investigação criminal. Para viabilizar o estudo, efectuou-se à priori a recolha de várias amostras de Toners, de diferentes marcas, de cartuchos originais e remanufacturados aplicando de seguida dois métodos de análise distintos: a Espectroscopia de infravermelho com transformada de Fourier (FT-IR) e a Espectroscopia de Absorção-Reflexão (ATR - Reflectância total atenuada). A espectroscopia FT-IR permitiu obter a base de dados de espectros em suporte KBr e usando o software OPUS, das várias amostras de Toners dos cartuchos originais e remanufacturados recolhidas. Para se criar o método de comparação entre espectros, realizou-se o mesmo procedimento mas agora para amostras obtidas por raspagem de um papel impresso /quadrados 2x2), bem como para o papel de impressão para se poder descontar este da amostra. Dado que o interesse desta análise se remetia ao estudo de textos escritos, efectuou-se a análise de um texto padrão por Espectroscopia FT-IR. O método foi utilizado à posteriori como método de comparação e uma alternativa (não destrutiva) ao método de FT-IR para se aplicar a casos reais. Os espectros foram obtidos num microscópio usando o silício como acessório ATR e o software OMNIC. Finalizado o estudo pode-se concluir, quanto à espectroscopia FT-IR, que as amostras da marca HP e Minolta apresentaram espectros muito semelhantes, quando se faz uma análise global dos mesmos. No entanto, as restantes marcas são também muito parecidas entre si, mas ainda é possível encontrar algumas distinções quando se efectua a comparação visual principalmente abaixo da zona de impressão digital (<6000 cm-1). Relativamente aos Toners remanufacturados, constata-se que são muito semelhantes e que diferem da marca original apenas pelo elevado grau de humidade que possuem. No que diz respeito ao método ATR, verificou-se que apesar de ser um método não destrutivo da amostra revela-se bastante limitado, devido ao uso do cristal de Silício como acessório que só atinge comprimentos de onda entre 4000-1500cm-1.
Resumo:
We report in this paper the recent advances we obtained in optimizing a color image sensor based on the laser-scanned-photodiode (LSP) technique. A novel device structure based on a a-SiC:H/a-Si:H pin/pin tandem structure has been tested for a proper color separation process that takes advantage on the different filtering properties due to the different light penetration depth at different wavelengths a-SM and a-SiC:H. While the green and the red images give, in comparison with previous tested structures, a weak response, this structure shows a very good recognition of blue color under reverse bias, leaving a good margin for future device optimization in order to achieve a complete and satisfactory RGB image mapping. Experimental results about the spectral collection efficiency are presented and discussed from the point of view of the color sensor applications. The physics behind the device functioning is explained by recurring to a numerical simulation of the internal electrical configuration of the device.
Resumo:
An optimized ZnO:Al/a-pin SixCl1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed. The LSP utilizes light induced depletion layers as detector and a laser beam for readout. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Experimental data reveal that the large optical gap and the low conductivity of the doped a-SixC1-x:H layers are responsible by an induced inversion layer at the illuminated interfaces which blocks the carrier collection. These insulator-like layers act as MIS gates preventing image smearing. The physical background of the LSP is discussed.
Resumo:
An optimized ZnO:Al/a-pin SixC1-x:H/Al configuration for the laser scanned photodiode (LSP) imaging detector is proposed and the read-out parameters improved. The effect of the sensing element structure, cell configuration and light source flux are investigated and correlated with the sensor output characteristics. Data reveals that for sensors with wide band gap doped layers an increase on the image signal optimized to the blue is achieved with a dynamic range of two orders of magnitude, a responsivity of 6 mA W-1 and a sensitivity of 17 muW cm(-2) at 530 nm. The main output characteristics such as image responsivity, resolution, linearity and dynamic range were analyzed under reverse, forward and short circuit modes. The results show that the sensor performance can be optimized in short circuit mode. A trade-off between the scan time and the required resolution is needed since the spot size limits the resolution due to the cross-talk between dark and illuminated regions leading to blurring effects.
Resumo:
Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a double colour laser scanned photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the colour detection process are analysed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.
Resumo:
Large area n-i-p-n-i-p a-SiC:H heterostructures are used as sensing element in a Double Color Laser Scanned Photodiode image sensor (D/CLSP). This work aims to clarify possible improvements, physical limits and performance of CLSP image sensor when used as non-pixel image reader. Here, the image capture device and the scanning reader are optimized and the effects of the sensor structure on the output characteristics discussed. The role of the design of the sensing element, the doped layer composition and thickness, the read-out parameters (applied voltage and scanner frequency) on the image acquisition and the color detection process are analyzed. A physical model is presented and supported by a numerical simulation of the output characteristics of the sensor.