993 resultados para CO2 REMOVAL


Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the process of interferometric testing, the measurement result is influenced by the system structure, which reduces the measurement accuracy. To obtain an accurate test result, it is necessary to analyze the test system, and build the relationship between the measurement error and the system parameters. In this paper, the influences of the system elements which include the collimated lens and the standard surface on the interferometric testing are analyzed, the expressions of phase distribution and wavefront error on the detector are obtained, the method to remove some element errors is introduced, and the optimization structure relationships are given. (C) 2006 Elsevier GmbH. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Wastewater treatment reduces environmental contamination by removing gross solids and mitigating the effects of pollution. Treatment also reduces the number of indicator organisms and pathogens. In this work, the fates of two coliform bacteria, Escherichia coli and Serratia marcescens, were analyzed in an activated sludge process to determine the main mechanisms involved in the reduction of pathogenic microorganisms during wastewater treatment. These bacteria, modified to express green fluorescent protein, were inoculated in an activated sludge unit and in batch systems containing wastewater. The results suggested that, among the different biological factors implied in bacterial removal, bacterivorous protozoa play a key role. Moreover, a representative number of bacteria persisted in the system as free-living or embedded cells, but their distribution into liquid or solid fractions varied depending on the bacterium tested, questioning the real value of bacterial indicators for the control of wastewater treatment process. Additionally, viable but nonculturable cells constituted an important part of the bacterial population adhered to solid fractions, what can be derived from the competition relationships with native bacteria, present in high densities in this environment. These facts, taken together, emphasize the need for reliable quantitative and qualitative analysis tools for the evaluation of pathogenic microbial composition in sludge, which could represent an undefined risk to public health and ecosystem functions when considering its recycling.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

[EN]Due to the limitations associated with fossil fuels it is necessary to promote energy sources that are renewable as well as eco-friendly, such as biogas generated in anaerobic digesters. The biogas, composed principally of methane and CO2, is the result of the biodegradation of organic matter under anaerobic conditions. Its use as fuel is limited by the presence of minority compounds such as hydrogen sulphide (H2S); therefore, its pre-treatment is necessary. Currently there are various technologies for the removal of H2S from a gas stream, but most of them are based on physic-chemical treatments which have a number of drawbacks as reactive consumption, generation of secondary flows, etc. Biofiltration has been used as an efficient and low cost alternative to conventional purification processes, and excellent results for the degradation of H2S have been obtained. However process can be limited due to the progressive ageing of the support material, along with the loss of nutrients and other specific characteristics necessary for the good development of biomass. The purpose of this project is to develop a mixed support consisting of a mixture of an organic material and an inorganic support for its application in the removal of the H2S from biogas. This support material helps to optimize the characteristics of the bed and extend its lifespan. The development of such material will contribute to the implementation of biofiltration for treating biogas from anaerobic digesters for its use as biofuel. The inorganic material used is electric arc furnace (EAF) black slag, a by-product generated in large quantities in the production of steel in the Basque Country. Although traditionally the slag has been used in civil engineering, its physicochemical characteristics make it suitable for reuse as a filter medium in biofiltration. The main conclusion drawn from the experimental results is that EAF black slag is a suitable co-packing material in organic biofilters treating H2S-polluted gaseous streams. High pollutant removal rates have been achieved during the whole experimental period. The removal capacity recorded in biofilters with less inorganic material was higher than in those with higher slag portion. Nevertheless, all the biofilters have shown a satisfactory response even at high inlet loads (48 g·m-3·h-1), where the RE has not decreased over 82%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel high-average-power pulsed CO2 laser with a unique electrode structure is presented. The operation of a 5-kW transverse-flow CO2 laser with the preionized pulse-train switched technique results in pulsation of the laser power, and the average laser power is about 5 kW. The characteristic of this technique is switching the preionized pulses into pulse trains so as to use the small preionized power (hundreds of watts) to control the large main-discharge power (tens of kilowatts). By this means, the cost and the complexity of the power supply are greatly reduced. The welding of LF2, LF21, LD2, and LY12 aluminum alloy plates has been successfully achieved using this laser. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel high-average-power pulsed CO2 laser with a unique electrode structure is presented. The operation of a 5-kW transverse-flow CO2 laser with the preionized pulse-train switched technique results in pulsation of the laser power, and the average laser power is about 5 kW. The characteristic of this technique is switching the preionized pulses into pulse trains so as to use the small preionized power (hundreds of watts) to control the large main-discharge power (tens of kilowatts). By this means, the cost and the complexity of the power supply are greatly reduced. The welding of LF2, LF21, LD2, and LY12 aluminum alloy plates has been successfully achieved using this laser. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Entre os polímeros considerados promissores para a remoção seletiva de CO2, destacam-se aqueles que contêm os grupos glicol etilênico (EG). Nesta dissertação, foram obtidos filmes a partir de dispersões aquosas de poliuretano (PU), sintetizadas em trabalho anterior, à base de poli(glicol propilênico) (PPG), copolímero em bloco à base de poli(glicol etilênico) (PEG) e PPG (EG-b-PG), ácido dimetilolpropiônico (DMPA), diisocianato de isoforona (IPDI) e etilenodiamina (EDA). PPG, EG-b-PG e DMPA formaram as regiões flexíveis nas proporções de: PPG 100% e 0% EG-b-PG, PPG 75% e 25% EG-b-PG, PPG 50% e 50% EG-b-PG e PPG 25% e 75% EG-b-PG em termos de equivalentes-gramas. A influência da quantidade dos segmentos de PEG foi avaliada por ensaios de permeação com os gases CO2, CH4 e N2. Os filmes obtidos das dispersões foram caracterizados por espectrometria de infravermelho com transformadas de Fourier (FTIR), análise termogravimétrica (TGA), difração de raios x (DRX) e espalhamento de raios X a baixo ângulo (SAXS). Espectros de FTIR mostraram que os segmentos de EG influenciaram a frequência da banda de carbonila. Curvas de perda de massa (TG) mostraram perfis semelhantes de degradação, enquanto que as curvas derivadas apresentaram diferenças. DRX e SAXS mostraram que os segmentos de PEG promoveram uma maior ordenação na estrutura da membrana. Testes de permeação de gases mostraram que o aumento do teor de PEG aumentou o valor da permeabilidade para o CO2, indicando que os segmentos de PEG interagiram favoravelmente com este gás. Em relação ao CH4 e N2, houve uma diminuição na permeabilidade quando comparados com os valores encontrados para o CO2, sendo atribuído a perda de mobilidade segmental. Em termos de seletividade, para o par CO2/CH4 foi obtido um valor médio de 61,7 para a membrana contendo o maior teor de PEG, e o par CO2/N2 um valor médio de 121,5, sendo superior aos valores encontrados na literatura, tornando o material promissor

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total CO2 of brackish water (Ebrié lagoon) is measured with a simple method: degassing and trapping CO2 in NaOh solution, the conductivity of which is a function of the trapped CO2 quantity. A relation CO2 versus salinity is deduced; it is nearly the same as the one deduced from CO2 measurements performed from alkalinity. Dissolved organic C is evaluated with a CHN analyser by evaporating 0.5 ml of acidified sample. Variation coefficient is near 10% for the lagoon values.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To understand mechanisms underlying laser-induced damage of BK7 and fused silica, we calculate the temperature field of the substrates with CO2 laser irradiating at a given laser power and beam radius. We find that the two glasses show different thermal behaviors. A model is developed for estimating the time t to heat the surface of the substrates up to a particular temperature T with cw CO2 laser irradiation. We calculate theoretically the duration t that the samples are irradiated, from the beginning to visual catastrophic damage, with the assumption of damage threshold determined by the critical temperature. The duration t that the samples are irradiated, from the beginning to visual catastrophic damage, is investigated experimentally as well. Here we take the melting point or softening point as the critical temperature, given the thermomechanical coupling properties, which is enough to cause damage for BK7. Damage features are characterized by the sound of visual cracks. Finally, we calculate stresses induced by laser heating. The analysis of stress indicates that the damage of BK7 is due to the stresses induced by laser heating. (c) 2005 Society of Photo-Optical Instrumentation Engineers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The measurement of high speed laser beam parameters during processing is a topic that has seen growing attention over the last few years as quality assurance places greater demand on the monitoring of the manufacturing process. The targets for any monitoring system is to be non-intrusive, low cost, simple to operate, high speed and capable of operation in process. A new ISO compliant system is presented based on the integration of an imaging plate and camera located behind a proprietary mirror sampling device. The general layout of the device is presented along with the thermal and optical performance of the sampling optic. Diagnostic performance of the system is compared with industry standard devices, demonstrating the high quality high speed data which has been generated using this system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To understand mechanisms underlying laser-induced damage of BK7 and fused silica, we calculate the temperature field of the substrates with CO2 laser irradiating at a given laser power and beam radius. We find that the two glasses show different thermal behaviors. A model is developed for estimating the time t to heat the surface of the substrates up to a particular temperature T with cw CO2 laser irradiation. We calculate theoretically the duration t that the samples are irradiated, from the beginning to visual catastrophic damage, with the assumption of damage threshold determined by the critical temperature. The duration t that the samples are irradiated, from the beginning to visual catastrophic damage, is investigated experimentally as well. Here we take the melting point or softening point as the critical temperature, given the thermomechanical coupling properties, which is enough to cause damage for BK7. Damage features are characterized by the sound of visual cracks. Finally, we calculate stresses induced by laser heating. The analysis of stress indicates that the damage of BK7 is due to the stresses induced by laser heating. (c) 2005 Society of Photo-Optical Instrumentation Engineers.