953 resultados para Body-water Measurement
Resumo:
The concept of energy gap(s) is useful for understanding the consequence of a small daily, weekly, or monthly positive energy balance and the inconspicuous shift in weight gain ultimately leading to overweight and obesity. Energy gap is a dynamic concept: an initial positive energy gap incurred via an increase in energy intake (or a decrease in physical activity) is not constant, may fade out with time if the initial conditions are maintained, and depends on the 'efficiency' with which the readjustment of the energy imbalance gap occurs with time. The metabolic response to an energy imbalance gap and the magnitude of the energy gap(s) can be estimated by at least two methods, i.e. i) assessment by longitudinal overfeeding studies, imposing (by design) an initial positive energy imbalance gap; ii) retrospective assessment based on epidemiological surveys, whereby the accumulated endogenous energy storage per unit of time is calculated from the change in body weight and body composition. In order to illustrate the difficulty of accurately assessing an energy gap we have used, as an illustrative example, a recent epidemiological study which tracked changes in total energy intake (estimated by gross food availability) and body weight over 3 decades in the US, combined with total energy expenditure prediction from body weight using doubly labelled water data. At the population level, the study attempted to assess the cause of the energy gap purported to be entirely due to increased food intake. Based on an estimate of change in energy intake judged to be more reliable (i.e. in the same study population) and together with calculations of simple energetic indices, our analysis suggests that conclusions about the fundamental causes of obesity development in a population (excess intake vs. low physical activity or both) is clouded by a high level of uncertainty.
Resumo:
BACKGROUND: Preoperative marking is of primary importance in body contouring and when precise simulation of skin excisions is difficult. Because the "cut as you go" principle can be delicate, especially in patients after massive weight loss, a simple and quick method is needed for preoperative planning. We suggest an approach that helps visualize the optimal skin incision lines and simulates the postoperative result by body taping. METHODS: Twelve patients who underwent abdominal contouring, including classic and vertical abdominoplasties as well as dog ear and scar revision, were prospectively analyzed. The skin to be excised was preoperatively folded, taped, and then marked. The area marked was measured and compared with the actual intraoperatively resected area and the postoperative result was evaluated after 1 year by the patients and three surgeons. RESULTS: With body taping, an 83% congruence between the preoperative planning and the surgery was obtained and only two patients had additional skin resected. No wound dehiscence and flap necrosis occurred and patients as well as surgeons scored the final body contour positively. CONCLUSION: Body taping is a simple, quick, and economic method for planning contour surgery with high accuracy as demonstrated by the low rate of intraoperative changes of the planned resection and low complication rate.
Resumo:
The goal of this study was to investigate the impact of computing parameters and the location of volumes of interest (VOI) on the calculation of 3D noise power spectrum (NPS) in order to determine an optimal set of computing parameters and propose a robust method for evaluating the noise properties of imaging systems. Noise stationarity in noise volumes acquired with a water phantom on a 128-MDCT and a 320-MDCT scanner were analyzed in the spatial domain in order to define locally stationary VOIs. The influence of the computing parameters in the 3D NPS measurement: the sampling distances bx,y,z and the VOI lengths Lx,y,z, the number of VOIs NVOI and the structured noise were investigated to minimize measurement errors. The effect of the VOI locations on the NPS was also investigated. Results showed that the noise (standard deviation) varies more in the r-direction (phantom radius) than z-direction plane. A 25 × 25 × 40 mm(3) VOI associated with DFOV = 200 mm (Lx,y,z = 64, bx,y = 0.391 mm with 512 × 512 matrix) and a first-order detrending method to reduce structured noise led to an accurate NPS estimation. NPS estimated from off centered small VOIs had a directional dependency contrary to NPS obtained from large VOIs located in the center of the volume or from small VOIs located on a concentric circle. This showed that the VOI size and location play a major role in the determination of NPS when images are not stationary. This study emphasizes the need for consistent measurement methods to assess and compare image quality in CT.
Resumo:
PURPOSE OF REVIEW: The kidney plays an essential role in maintaining sodium and water balance, thereby controlling the volume and osmolarity of the extracellular body fluids, the blood volume and the blood pressure. The final adjustment of sodium and water reabsorption in the kidney takes place in cells of the distal part of the nephron in which a set of apical and basolateral transporters participate in vectorial sodium and water transport from the tubular lumen to the interstitium and, finally, to the general circulation. According to a current model, the activity and/or cell-surface expression of these transporters is/are under the control of a gene network composed of the hormonally regulated, as well as constitutively expressed, genes. It is proposed that this gene network may include new candidate genes for salt- and water-losing syndromes and for salt-sensitive hypertension. A new generation of functional genomics techniques have recently been applied to the characterization of this gene network. The purpose of this review is to summarize these studies and to discuss the potential of the different techniques for characterization of the renal transcriptome. RECENT FINDINGS: Recently, DNA microarrays and serial analysis of gene expression have been applied to characterize the kidney transcriptome in different in-vivo and in-vitro models. In these studies, a set of new interesting genes potentially involved in the regulation of sodium and water reabsorption by the kidney have been identified and are currently under detailed investigation. SUMMARY: Characterization of the kidney transcriptome is greatly expanding our knowledge of the gene networks involved in multiple kidney functions, including the maintenance of sodium and water homeostasis.
Resumo:
Velocity-density tests conducted in the laboratory involved small 4-inch diameter by 4.58-inch-long compacted soil cylinders made up of 3 differing soil types and for varying degrees of density and moisture content, the latter being varied well beyond optimum moisture values. Seventeen specimens were tested, 9 with velocity determinations made along two elements of the cylinder, 180 degrees apart, and 8 along three elements, 120 degrees apart. Seismic energy was developed by blows of a small tack hammer on a 5/8-inch diameter steel ball placed at the center of the top of the cylinder, with the detector placed successively at four points spaced 1/2-inch apart on the side of the specimen involving wave travel paths varying from 3.36 inches to 4.66 inches in length. Time intervals were measured using a model 217 micro-seismic timer in both laboratory and field measurements. Forty blows of the hammer were required for each velocity determination, which amounted to 80 blows on 9 laboratory specimens and 120 blows on the remaining 8 cylinders. Thirty-five field tests were made over the three selected soil types, all fine-grained, using a 2-foot seismic line with hammer-impact points at 6-inch intervals. The small tack hammer and 5/8-inch steel ball was, again, used to develop seismic wave energy. Generally, the densities obtained from the velocity measurements were lower than those measured in the conventional field testing. Conclusions were reached that: (1) the method does not appear to be usable for measurement of density of essentially fine-grained soils when the moisture content greatly exceeds the optimum for compaction, and (2) due to a gradual reduction in velocity upon aging, apparently because of gradual absorption of pore water into the expandable interlayer region of the clay, the seismic test should be conducted immediately after soil compaction to obtain a meaningful velocity value.
Resumo:
The aim of our study was to provide an innovative HS-GC/MS method applicable to the routine determination of butane concentration in forensic toxicology laboratories. The main drawback of the GC/MS methods discussed in literature concerning butane measurement was the absence of a specific butane internal standard necessary to perform quantification. Because no stable isotope of butane is commercially available, it is essential to develop a new approach by an in situ generation of standards. To avoid the manipulation of a stable isotope-labelled gas, we have chosen to generate in situ an internal labelled standard gas (C(4)H(9)D) following the basis of the stoichiometric formation of butane by the reaction of deuterated water (D(2)O) with Grignard reagent butylmagnesium chloride (C(4)H(9)MgCl). This method allows a precise measurement of butane concentration and therefore, a full validation by accuracy profile was presented.
Resumo:
The hydrogeological properties and responses of a productive aquifer in northeastern Switzerland are investigated. For this purpose, 3D crosshole electrical resistivity tomography (ERT) is used to define the main lithological structures within the aquifer (through static inversion) and to monitor the water infiltration from an adjacent river. During precipitation events and subsequent river flooding, the river water resistivity increases. As a consequence, the electrical characteristics of the infiltrating water can be used as a natural tracer to delineate preferential flow paths and flow velocities. The focus is primarily on the experiment installation, data collection strategy, and the structural characterization of the site and a brief overview of the ERT monitoring results. The monitoring system comprises 18 boreholes each equipped with 10 electrodes straddling the entire thickness of the gravel aquifer. A multi-channel resistivity system programmed to cycle through various four-point electrode configurations of the 180 electrodes in a rolling sequence allows for the measurement of approximately 15,500 apparent resistivity values every 7 h on a continuous basis. The 3D static ERT inversion of data acquired under stable hydrological conditions provides a base model for future time-lapse inversion studies and the means to investigate the resolving capability of our acquisition scheme. In particular, it enables definition of the main lithological structures within the aquifer. The final ERT static model delineates a relatively high-resistivity, low-porosity, intermediate-depth layer throughout the investigated aquifer volume that is consistent with results from well logging and seismic and radar tomography models. The next step will be to define and implement an appropriate time-lapse ERT inversion scheme using the river water as a natural tracer. The main challenge will be to separate the superposed time-varying effects of water table height, temperature, and salinity variations associated with the infiltrating water.
Resumo:
OBJECTIVE: To compare the heart-rate monitoring with the doubly labelled water (2H2(18)O) method to estimate total daily energy expenditure in obese and non-obese children. DESIGN: Cross sectional study of obese and normal weight children. SUBJECTS: 13 prepubertal children: six obese (4M, 2F, 9.1 +/- 1.5 years, 47.3 +/- 9.7 kg) and seven non-obese (3M, 4F, 9.3 +/- 0.6 years, 31.8 +/- 3.2 kg). MEASUREMENTS: Total daily energy expenditure was assessed by means of the doubly labelled water method (TEEDLW) and of heart-rate monitoring (TEEHR). RESULTS: TEEHR was significantly (P < 0.05) higher than TEEDLW in obese children (9.47 +/- 0.84 MJ/d vs 8.99 +/- 0.63 MJ/d) whereas it was not different in non-obese children (8.43 +/- 2.02 MJ/d vs 8.42 +/- 2.30 MJ/d, P = NS). The difference of TEE assessed by HR monitoring in the obese group averaged 6.2 +/- 4.7%. At the individual level, the degree of agreement (difference between TEEHR and TEEDLW +/- 2s.d.) was low both in obese (-0.36, 1.32 MJ/d) and in non-obese children (-1.30, 1.34 MJ/d). At the group level, the agreement between the two methods was good in nonobese children (95% c.i. for the bias:-0.59, 0.63 MJ/d) but not in obese children (0.04, 0.92 MJ/d). Duration of sleep and energy expenditure during resting and physical activity were not significantly different in the two groups. Patterns of heart-rate (or derived energy expenditure) during the day-time were similar in obese and non-obese children. CONCLUSION: The HR monitoring technique provides an estimation of TEE close to that assessed by the DLW method in non-obese prepubertal children. In comparison with DLW, the HR monitoring method yields a greater TEE value in obese children.
Resumo:
Ambulatory blood pressure monitoring (ABPM) has become indispensable for the diagnosis and control of hypertension. However, no consensus exists on how daytime and nighttime periods should be defined. OBJECTIVE: To compare daytime and nighttime blood pressure (BP) defined by an actigraph and by body position with BP resulting from arbitrary daytime and nighttime periods. PATIENTS AND METHOD: ABPM, sleeping periods and body position were recorded simultaneously using an actigraph (SenseWear Armband(®)) in patients referred for ABPM. BP results obtained with the actigraph (sleep and position) were compared to the results obtained with fixed daytime (7a.m.-10p.m.) and nighttime (10p.m.-7a.m.) periods. RESULTS: Data from 103 participants were available. More than half of them were taking antihypertensive drugs. Nocturnal BP was lower (systolic BP: 2.08±4.50mmHg; diastolic BP: 1.84±2.99mmHg, P<0.05) and dipping was more marked (systolic BP: 1.54±3.76%; diastolic BP: 2.27±3.48%, P<0.05) when nighttime was defined with the actigraph. Standing BP was higher (systolic BP 1.07±2.81mmHg; diastolic BP: 1.34±2.50mmHg) than daytime BP defined by a fixed period. CONCLUSION: Diurnal BP, nocturnal BP and dipping are influenced by the definition of daytime and nighttime periods. Studies evaluating the prognostic value of each method are needed to clarify which definition should be used.
Resumo:
Recently, we examined the spermatogenesis cycle length in two shrews species, Sorex araneus characterized by a very high metabolic rate and a polyandric mating system (sperm competition) resulting in a short cycle and Crocidura russula characterized by a much lower metabolic rate and a monogamous mating system showing a longer cycle. In this study, we investigated the spermatogenesis cycle in Neomys fodiens showing an intermediate metabolic rate. We described the stages of seminiferous epithelium according to the spermatid morphology method and we calculated the cycle length of spermatogenesis using incorporation of 5-bromodeoxyuridine into DNA of the germ cells. Twelve males were injected intraperitoneally with 5-bromodeoxyuridine, and the testes were collected. For cycle length determination, we applied a recently developed statistical method. The calculated cycle length is 8.69 days and the total duration of spermatogenesis based on 4.5 cycles is approximately 39.1 days, intermediate between the duration of spermatogenesis of S. araneus (37.6 days) and C. russula (54.5 days) and therefore congruent with both the metabolic rate hypothesis and the sperm competition hypothesis. Relative testes size of 1.4% of body mass indicates a promiscuous mating system.
Resumo:
Combining bacterial bioreporters with microfluidics systems holds great promise for in-field detection of chemical or toxicity targets. Recently we showed how Escherichia coli cells engineered to produce a variant of green fluorescent protein after contact to arsenite and arsenate can be encapsulated in agarose beads and incorporated into a microfluidic chip to create a device for in-field detection of arsenic, a contaminant of well known toxicity and carcinogenicity in potable water both in industrialized and developing countries. Cell-beads stored in the microfluidics chip at -20°C retained inducibility up to one month and we were able to reproducibly discriminate concentrations of 10 and 50 μg arsenite per L (the drinking water standards for European countries and the United States, and for the developing countries, respectively) from the blank in less than 200 minutes. We discuss here the reasons for decreasing bioreporter signal development upon increased storage of cell beads but also show how this decrease can be reduced, leading to a faster detection and a longer lifetime of the device.
Resumo:
In lentic water bodies, such as lakes, the water temperature near the surface typically increases during the day, and decreases during the night as a consequence of the diurnal radiative forcing (solar and infrared radiation). These temperature variations penetrate vertically into the water, transported mainly by heat conduction enhanced by eddy diffusion, which may vary due to atmospheric conditions, surface wave breaking, and internal dynamics of the water body. These two processes can be described in terms of an effective thermal diffusivity, which can be experimentally estimated. However, the transparency of the water (depending on turbidity) also allows solar radiation to penetrate below the surface into the water body, where it is locally absorbed (either by the water or by the deployed sensors). This process makes the estimation of effective thermal diffusivity from experimental water temperature profiles more difficult. In this study, we analyze water temperature profiles in a lake with the aim of showing that assessment of the role played by radiative forcing is necessary to estimate the effective thermal diffusivity. To this end we investigate diurnal water temperature fluctuations with depth. We try to quantify the effect of locally absorbed radiation and assess the impact of atmospheric conditions (wind speed, net radiation) on the estimation of the thermal diffusivity. The whole analysis is based on the results of fiber optic distributed temperature sensing, which allows unprecedented high spatial resolution measurements (∼4 mm) of the temperature profile in the water and near the water surface.
Resumo:
With regard to semi-aquatic mammals, Schröpfer & Stubbe (1992) distinguished three riparian guilds: the herbivores with the water vole and the beaver; the megacarnivores with the mink and the otter; and the macrocarnivores with water shrews and desmans. Among water shrews, the evolution of aquatic foraging behaviour occurred several times: Nectogale and Chimarrogale in Asia, several species of the genus Sorex in America, and Neomys in Eurasia (Churchfield, 1990). The fairly common European water shrew N. fodiens is the best known. However, the reports on the degree of adaptation to the water habitat are conflicting. Therefore some important findings from the literature are reviewed in this introduction, whereas new data are presented in the following sections. The swimming locomotion of water shrews was analysed by Ruthardt & Schröpfer (1985) and Köhler (1991), and the related morphological adaptation were reviewed by Hutterer (1985) and Churchfield (this volume pp. 49-51). They obviously present a compromise between the requirements for activity on land and in the water. Thermoregulation is a major problem for semi-aquatic mammals, because heat conductance in water is 25-fold greater than in air (Calder, 1969). According to this author, the body temperature of immersed American Sorex palustris dropped by a rate of 2.8 °C per min. However, this may be an experimental artefact, because Neomys fodiens can maintain its body temperature at 37 °C during an immersion of 6 min (Vogel, 1990).
Resumo:
Due to the intense international competition, demanding, and sophisticated customers, and diverse transforming technological change, organizations need to renew their products and services by allocating resources on research and development (R&D). Managing R&D is complex, but vital for many organizations to survive in the dynamic, turbulent environment. Thus, the increased interest among decision-makers towards finding the right performance measures for R&D is understandable. The measures or evaluation methods of R&D performance can be utilized for multiple purposes; for strategic control, for justifying the existence of R&D, for providing information and improving activities, as well as for the purposes of motivating and benchmarking. The earlier research in the field of R&D performance analysis has generally focused on either the activities and considerable factors and dimensions - e.g. strategic perspectives, purposes of measurement, levels of analysis, types of R&D or phases of R&D process - prior to the selection of R&Dperformance measures, or on proposed principles or actual implementation of theselection or design processes of R&D performance measures or measurement systems. This study aims at integrating the consideration of essential factors anddimensions of R&D performance analysis to developed selection processes of R&D measures, which have been applied in real-world organizations. The earlier models for corporate performance measurement that can be found in the literature, are to some extent adaptable also to the development of measurement systemsand selecting the measures in R&D activities. However, it is necessary to emphasize the special aspects related to the measurement of R&D performance in a way that make the development of new approaches for especially R&D performance measure selection necessary: First, the special characteristics of R&D - such as the long time lag between the inputs and outcomes, as well as the overall complexity and difficult coordination of activities - influence the R&D performance analysis problems, such as the need for more systematic, objective, balanced and multi-dimensional approaches for R&D measure selection, as well as the incompatibility of R&D measurement systems to other corporate measurement systems and vice versa. Secondly, the above-mentioned characteristics and challenges bring forth the significance of the influencing factors and dimensions that need to be recognized in order to derive the selection criteria for measures and choose the right R&D metrics, which is the most crucial step in the measurement system development process. The main purpose of this study is to support the management and control of the research and development activities of organizations by increasing the understanding of R&D performance analysis, clarifying the main factors related to the selection of R&D measures and by providing novel types of approaches and methods for systematizing the whole strategy- and business-based selection and development process of R&D indicators.The final aim of the research is to support the management in their decision making of R&D with suitable, systematically chosen measures or evaluation methods of R&D performance. Thus, the emphasis in most sub-areas of the present research has been on the promotion of the selection and development process of R&D indicators with the help of the different tools and decision support systems, i.e. the research has normative features through providing guidelines by novel types of approaches. The gathering of data and conducting case studies in metal and electronic industry companies, in the information and communications technology (ICT) sector, and in non-profit organizations helped us to formulate a comprehensive picture of the main challenges of R&D performance analysis in different organizations, which is essential, as recognition of the most importantproblem areas is a very crucial element in the constructive research approach utilized in this study. Multiple practical benefits regarding the defined problemareas could be found in the various constructed approaches presented in this dissertation: 1) the selection of R&D measures became more systematic when compared to the empirical analysis, as it was common that there were no systematic approaches utilized in the studied organizations earlier; 2) the evaluation methods or measures of R&D chosen with the help of the developed approaches can be more directly utilized in the decision-making, because of the thorough consideration of the purpose of measurement, as well as other dimensions of measurement; 3) more balance to the set of R&D measures was desired and gained throughthe holistic approaches to the selection processes; and 4) more objectivity wasgained through organizing the selection processes, as the earlier systems were considered subjective in many organizations. Scientifically, this dissertation aims to make a contribution to the present body of knowledge of R&D performance analysis by facilitating dealing with the versatility and challenges of R&D performance analysis, as well as the factors and dimensions influencing the selection of R&D performance measures, and by integrating these aspects to the developed novel types of approaches, methods and tools in the selection processes of R&D measures, applied in real-world organizations. In the whole research, facilitation of dealing with the versatility and challenges in R&D performance analysis, as well as the factors and dimensions influencing the R&D performance measure selection are strongly integrated with the constructed approaches. Thus, the research meets the above-mentioned purposes and objectives of the dissertation from the scientific as well as from the practical point of view.
Resumo:
Postmortem human chorionic gonadotrophin (HCG) blood assay can confirm postmortem diagnosis of pregnancy or document situations in which HCG levels are elevated. In some cases, however, blood sampling is not possible at autopsy. In this study, HCG was quantified by enzyme-linked fluorescent assay (ELFA) in the bile (n = 5), vitreous humor (n = 4), and postmortem blood (n = 4) of five pregnant women. There were no false negatives in the pregnant subjects (n = 5) or false positives in controls (n = 34), enabling this test to be recommended for routine use in forensic contexts in which the detection of elevated HCG levels could be of interest.