923 resultados para Aortic Input Impedance
Resumo:
BACKGROUND: In chronic kidney disease (CKD) patients, the intake of calcium-based phosphate binders is associated with a marked progression of coronary artery and aortic calcification, in contrast to patients receiving calcium-free phosphate binders. The aim of this study was to reexamine the role of calcium carbonate in vascular calcification and to analyse its effect on aortic calcification-related gene expression in chronic renal failure (CRF). METHODS: Mice deficient in apolipoprotein E underwent either sham operation or subtotal nephrectomy to create CRF. They were then randomly assigned to one of the three following groups: a control non-CRF group and a CRF group fed on standard diet, and a CRF group fed on calcium carbonate enriched diet, for a period of 8 weeks. Aortic atherosclerotic plaque and calcification were evaluated using quantitative morphologic image processing. Aortic gene and protein expression was examined using immunohistochemistry and Q-PCR methods. RESULTS: Calcium carbonate supplementation was effective in decreasing serum phosphorus but was associated with a higher serum calcium concentration. Compared with standard diet, calcium carbonate enriched diet unexpectedly induced a significant decrease of both plaque (p<0.05) and non-plaque-associated calcification surface (p<0.05) in CRF mice. It also increased osteopontin (OPN) protein expression in atherosclerotic lesion areas of aortic root. There was also a numerical increase in OPN and osteoprotegerin gene expression in total thoracic aorta but the difference did not reach the level of significance. Finally, calcium carbonate did not change the severity of atherosclerotic lesions. CONCLUSION: In this experimental model of CRF, calcium carbonate supplementation did not accelerate but instead decreased vascular calcification. If our observation can be extrapolated to humans, it appears to question the contention that calcium carbonate supplementation, at least when given in moderate amounts, necessarily enhances vascular calcification. It is also compatible with the hypothesis of a preponderant role of phosphorus over that of calcium in promoting vascular calcification in CRF.
Resumo:
The pseudo-spectral time-domain (PSTD) method is an alternative time-marching method to classicalleapfrog finite difference schemes in the simulation of wave-like propagating phenomena. It is basedon the fundamentals of the Fourier transform to compute the spatial derivatives of hyperbolic differential equations. Therefore, it results in an isotropic operator that can be implemented in an efficient way for room acoustics simulations. However, one of the first issues to be solved consists on modeling wallabsorption. Unfortunately, there are no references in the technical literature concerning to that problem. In this paper, assuming real and constant locally reacting impedances, several proposals to overcome this problem are presented, validated and compared to analytical solutions in different scenarios.
Resumo:
The Pseudo-Spectral Time Domain (PSTD) method is an alternative time-marching method to classical leapfrog finite difference schemes inthe simulation of wave-like propagating phenomena. It is based on the fundamentals of the Fourier transform to compute the spatial derivativesof hyperbolic differential equations. Therefore, it results in an isotropic operator that can be implemented in an efficient way for room acousticssimulations. However, one of the first issues to be solved consists on modeling wall absorption. Unfortunately, there are no references in thetechnical literature concerning to that problem. In this paper, assuming real and constant locally reacting impedances, several proposals toovercome this problem are presented, validated and compared to analytical solutions in different scenarios.
Resumo:
The mutual information of independent parallel Gaussian-noise channels is maximized, under an average power constraint, by independent Gaussian inputs whose power is allocated according to the waterfilling policy. In practice, discrete signalling constellations with limited peak-to-average ratios (m-PSK, m-QAM, etc) are used in lieu of the ideal Gaussian signals. This paper gives the power allocation policy that maximizes the mutual information over parallel channels with arbitrary input distributions. Such policy admits a graphical interpretation, referred to as mercury/waterfilling, which generalizes the waterfilling solution and allows retaining some of its intuition. The relationship between mutual information of Gaussian channels and nonlinear minimum mean-square error proves key to solving the power allocation problem.
Resumo:
We characterize the capacity-achieving input covariance for multi-antenna channels known instantaneously at the receiver and in distribution at the transmitter. Our characterization, valid for arbitrary numbers of antennas, encompasses both the eigenvectors and the eigenvalues. The eigenvectors are found for zero-mean channels with arbitrary fading profiles and a wide range of correlation and keyhole structures. For the eigenvalues, in turn, we present necessary and sufficient conditions as well as an iterative algorithm that exhibits remarkable properties: universal applicability, robustness and rapid convergence. In addition, we identify channel structures for which an isotropic input achieves capacity.
Resumo:
Rapport de synthèseObjectif: le remplacement valvulaire aortique par voie transcathétère est, actuellement, une méthode fiable indiquée pour des patients à haut risque porteurs d'une sténose valvulaire aortique. La voie transfémorale est utilisable seulement en cas d'absence de maladie vasculaire et la voie transapicale est contrindiquée en cas de dysfonction pulmonaire chronique sévère. Une alternative pour ne pas passer a travers l'espace pleural serait par voie sous- xiphoïdienne et trans-septale à travers le ventricule droit.Méthode: une expérience animale a été amené au laboratoire de recherche du CHUV. Cinq cochons (poids : 52.3±10.9 kg) ont été endormi et, sous anesthésie générale, le ventricule droit a été préparé a travers un accès sous- xiphoïdien. Ensuite, sous guide fluoroscopique et avec l'utilisation d'une échocardiographie intracardiaque, un accès trans-septal a été crée entre le ventricule droit et le ventricule gauche en utilisant des dilatateur de diamètre croissant (de 8F à 26F). Par la suite, une valve stentée crée dans le laboratoire en utilisant un stent en nitinol et du péricarde a été chargé dans une cartouche et introduite dans le ventricule gauche à travers un introducteur trans-septal. Enfin, la valve a été amené dans la chambre de chasse du ventricule gauche et ensuite dans la racine aortique et puis déployé au bon endroit. Quand le système a été retiré, le septum ventriculaire a pu être réparé par mise en place d'un système d'occlusion septal Amplazer. Trente minutes après la procédure, les animaux ont été sacrifié et le coeur a été analysé pour étudier le positionnement da la valve stentée, l'efficacité de la fermeture du septum inter-ventriculaire et la fermeture de la paroi du ventricule droit.Résultat : les cinq cochon ont tous eu un parfait positionnement et pose de la prothèse en position aortique au premier essai (efficacité 100%). Les procédures ont duré, moyennement, 49±4 minutes et la progressive dilatation de l'accès trans-septale à donné lieu à une communication inter-ventriculaire mesurable après dilatation avec du 18F et plus. Toutes les valves stentées ont été déployées au bon endroit avec un bon résultat du fonctionnement des valves prothétiques et absence d'insuffisance para prothétique. Pendant les procédures, des battement prématurés ainsi que des épisodes isolées de tachycardie supra ventriculaire ont été détectés. Par contre, il n'y a pas eu de bloc atrio-ventriculaire. Les pertes sanguines pendant les procédures étaient de 280±10mL, et les systèmes d'occlusion Amplatzer étaient tous bien déployés sans shunts inter-ventriculaires résiduels.Conclusion: la technique d'introduction de valve stentées par voie extrapleural (trans-ventriculaire et trans-septale) est techniquement possible et elle jette les bases pour le remplacement valvulaire aortique trans-ventriculaire sous anesthésie locale.
Resumo:
BACKGROUND: Knowledge in the aetiopathogeny of aortic disease helps to characterise aortic lesions better and determine the risk of evolution and therapeutic strategies as well. This article focusses on aneurysms and dissections, and excludes causes related to infection, systemic inflammatory diseases and trauma. METHODS AND RESULTS: The biomedical literature of the past 10 years has been reviewed here. Aortic diseases are heterogeneous along the aorta as far as their genetic determinants, contribution of smooth muscle cells, inflammation and thrombus formation are concerned. Degradation of extracellular matrix by proteases causing aortic disease is a 'terminal' event, modulated by genetic background, haemodynamic strain, cellular events and thrombus formation. New genetic determinants of aortic disease have been identified. Proteases degrading the aortic wall are derived from a variety of cell types in addition to macrophages, including neutrophils on the luminal thrombus, mesenchymal and endothelial cells in the wall. Smooth muscle cells contribute to aortic wall homeostasis against inflammation and proteolysis. The degradation of the wall is followed by, or paralleled with, a failure of aortic reconstruction. CONCLUSIONS: Aortic diseases are diverse, and involve a multiplicity of biological systems in the vascular wall and at the interface with blood. Future research needs to unravel distinct cellular and molecular mechanisms causing the clinical events, in particular, dissection, expansion of already formed aneurysms and rupture.
Resumo:
We study the minimum mean square error (MMSE) and the multiuser efficiency η of large dynamic multiple access communication systems in which optimal multiuser detection is performed at the receiver as the number and the identities of active users is allowed to change at each transmission time. The system dynamics are ruled by a Markov model describing the evolution of the channel occupancy and a large-system analysis is performed when the number of observations grow large. Starting on the equivalent scalar channel and the fixed-point equation tying multiuser efficiency and MMSE, we extend it to the case of a dynamic channel, and derive lower and upper bounds for the MMSE (and, thus, for η as well) holding true in the limit of large signal–to–noise ratios and increasingly large observation time T.
Resumo:
Objectif Evaluer l'évolution à long-terme d'une population de patients pédiatriques souffrant de sténose aortique congénitale et ayant subi une intervention chirurgicale sur cette valve, et déterminer les facteurs de risques associés à une ré-intervention. Patients et méthode De 1985 à 2009, 77 patients, en moyenne âgés de 5.8 ± 5-6 ans, ont été suivis dans notre Service durant 14.8 ± 9-1 années. Résultats La première intervention montre d'excellents résultats avec 86% des patients ayant un gradient aortique résiduel < 50 mmHg et seulement 7% avec une nouvelle fuite aortique >1. La survie à long terme est de 91% A 25 ans. A un intervalle de 7.6 ± 5-3 ans, 30 patients 011t nécessité une ré-intervention (39%), principalement à cause d'une récidive de la sténose aortique. Le pourcentage de patients libre de ré¬intervention était de 97, 89, 75, 53, and 42% à respectivement 1, 10,15, 20, et 25 ans. Les facteurs de risques cle ré-interventions étaient le gradient aortique residuel plus élevé (p=0.00 01), la fuite aortique post-intervention >1 (p=0.02), la valvuloplasty au ballon préalable (p-0.04) et l'épaisseur augmentée de la paroi postérieure du ventricule gauche (p=o.i). Conclusions L'intervention chirurgicale sur la valve aortique est un procédé sûr et efficace pour les sténoses aortiques congénitales et démontre d'excellents résultats au niveau de la survie. Cependant le taux de ré-intervention est élevé et influencé par le gradient aortique résiduel plus élevé, la fuite aortique post-intervention >1, la valvuloplasty au ballon préalable et l'épaisseur augmentée de la paroi postérieure du ventricule gauche. L'étude démontre qu'un suivi à long-terme est recommandé pour ces patients.
Resumo:
Postmortem imaging, including postmortem computed tomography angiography, has become an integral tool in forensic investigation in recent years. A relatively new technique, multiphase postmortem computed tomography angiography, allows detailed visualization of the vascular system and makes it possible to evaluate the dynamic perfusion of aortic branches, including the coronary arteries. Here, we report a case of aortic dissection involving the ascending aorta (type A) with coronary and carotid malperfusion. This case illustrates the complementary use of many of the diagnostic tools that are now available in forensic practice, from imaging to conventional autopsy to pathologic techniques such as immunohistochemistry.
Resumo:
Background and aim of the study: Bicuspid aortic valve is the most common congenital heart malformation, and a high percentage of patients with this condition will develop complications over time. It is rare that pilots undergo aortic valve surgery, and the confirmation of flight-licensing requirements after aortic valve replacement (AVR) is a challenge for the patient's cardiac surgeon and, particularly, for the Aeromedical Examiner (AME). Only AMEs are able to determine the flight status of pilots. Furthermore, in military and in civil aviation (e.g., Red Bull Air Race), the high G-load environment experienced by pilots is an exceptional physiological parameter, which must be considered postoperatively. Methods: A review was conducted of the aeronautical, surgical and medical literature, and of European pilot-licensing regulations. Case studies are also reported for two Swiss Air Force pilots. Results: According to European legislation, pilots can return to flight duty from the sixth postoperative month, with the following limitations: that an aortic bioprosthesis presents no restrictions in cardiac function, requires no cardioactive medications, yet requires a flight operation with co-pilot, the avoidance of accelerations over +3 Gz and, in military aviation, restricts the pilot to non-ejection-seat aircraft. The patient follow up must include both echocardiographic and rhythm assessments every six months. Mechanical prostheses cannot be certified because the required anticoagulation therapy is a disqualifying condition for pilot licensing. Conclusion: Pilot licensing after aortic valve surgery is possible, but with restrictions. The +Gz exposition is of concern in both military and civilian aviation (aerobatics). The choice of bioprosthesis type and size is determinant. Pericardial and stentless valves seem to show better flow characteristics under high-output conditions. Repetitive cardiological controls are mandatory for the early assessment of structural valve disease and rhythm disturbances. A pre-emptive timing is recommended when reoperation is indicated, without waiting for clinical manifestations of structural valve disease.
Resumo:
In this paper we study the relevance of multiple kernel learning (MKL) for the automatic selection of time series inputs. Recently, MKL has gained great attention in the machine learning community due to its flexibility in modelling complex patterns and performing feature selection. In general, MKL constructs the kernel as a weighted linear combination of basis kernels, exploiting different sources of information. An efficient algorithm wrapping a Support Vector Regression model for optimizing the MKL weights, named SimpleMKL, is used for the analysis. In this sense, MKL performs feature selection by discarding inputs/kernels with low or null weights. The approach proposed is tested with simulated linear and nonlinear time series (AutoRegressive, Henon and Lorenz series).
Resumo:
ABSTRACT: Transapical aortic valve replacement is an established technique performed in high-risk patients with symptomatic aortic valve stenosis and vascular disease contraindicating trans-vascular and trans-aortic procedures. The presence of a left ventricular apical diverticulum is a rare event and the treatment depends on dimensions and estimated risk of embolisation, rupture, or onset of ventricular arrhythmias. The diagnosis is based on standard cardiac imaging and symptoms are very rare. In this case report we illustrate our experience with a 81 years old female patient suffering from symptomatic aortic valve stenosis, respiratory disease, chronic renal failure and severe peripheral vascular disease (logistic euroscore: 42%), who successfully underwent a transapical 23 mm balloon-expandable stent-valve implantation through an apical diverticulum of the left ventricle. Intra-luminal thrombi were absent and during the same procedure were able to treat the valve disease and to successfully exclude the apical diverticulum without complications and through a mini thoracotomy. To the best of our knowledge, this is the first time that a transapical procedure is successfully performed through an apical diverticulum.
Resumo:
OBJECTIVE: Surface magnetic resonance imaging (MRI) for aortic plaque assessment is limited by the trade-off between penetration depth and signal-to-noise ratio (SNR). For imaging the deep seated aorta, a combined surface and transesophageal MRI (TEMRI) technique was developed 1) to determine the individual contribution of TEMRI and surface coils to the combined signal, 2) to measure the signal improvement of a combined surface and TEMRI over surface MRI, and 3) to assess for reproducibility of plaque dimension analysis. METHODS AND RESULTS: In 24 patients six black blood proton-density/T2-weighted fast-spin echo images were obtained using three surface and one TEMRI coil for SNR measurements. Reproducibility of plaque dimensions (combined surface and TEMRI) was measured in 10 patients. TEMRI contributed 68% of the signal in the aortic arch and descending aorta, whereas the overall signal gain using the combined technique was up to 225%. Plaque volume measurements had an intraclass correlation coefficient of as high as 0.97. CONCLUSION: Plaque volume measurements for the quantification of aortic plaque size are highly reproducible for combined surface and TEMRI. The TEMRI coil contributes considerably to the aortic MR signal. The combined surface and TEMRI approach improves aortic signal significantly as compared to surface coils alone. CONDENSED ABSTRACT: Conventional MRI aortic plaque visualization is limited by the penetration depth of MRI surface coils and may lead to suboptimal image quality with insufficient reproducibility. By combining a transesophageal MRI (TEMRI) with surface MRI coils we enhanced local and overall image SNR for improved image quality and reproducibility.
Resumo:
BACKGROUND: : The systolic augmentation index (sAix), calculated from the central aortic pulse wave (reconstructed from the noninvasive recording of the radial pulse with applanation tonometry), is widely used as a simple index of central arterial stiffness, but has the disadvantage of also being influenced by the timing of the reflected with respect to the forward pressure wave, as shown by its inverse dependence on heart rate (HR). During diastole, the central aortic pulse also contains reflected waves, but their relationship to arterial stiffness and HR has not been studied. METHODS: : In 48 men and 45 women, all healthy, with ages ranging from 19 to 70 years, we measured pulse wave velocity (PWV, patients supine), a standard evaluator of arterial stiffness, and carried out radial applanation tonometry (patients sitting and supine). The impact of reflected waves on the diastolic part of the aortic pressure waveform was quantified in the form of a diastolic augmentation index (dAix). RESULTS: : Across ages, sexes, and body position, there was an inverse relationship between the sAix and the dAix. When PWV and HR were added as covariates to a prediction model including age, sex and body position as main factors, the sAix was directly related to PWV (P < 0.0001) and inversely to HR (P < 0.0001). With the same analysis, the dAix was inversely related to PWV (P < 0.0001) and independent of HR (P = 0.52). CONCLUSION: : The dAix has the same degree of linkage to arterial stiffness as the more conventional sAix, while being immune to the confounding effect of HR. The quantification of diastolic aortic pressure augmentation by reflected waves could be a useful adjunct to pulse wave analysis.