415 resultados para Amortecedor metálico


Relevância:

10.00% 10.00%

Publicador:

Resumo:

In conservation agriculture, mainly under direct seeding, maintaining the vegetation ground cover is essential, since this serves as a reservoir of nutrients which are slowly released to plants by microorganisms. Some authors have sought to study increases in the amount of straw in the soil, in addition to slowing down the process of decomposition, with hormesis being one of the techniques used. This technique states that all chemical substances are both poisonous and nonpoisonous, with only the dosage determining whether they are lethal or not. This study aimed to evaluate the dry weight and agronomic characteristics of a crop of black oat subjected to hormesis. The experimental design was of randomised blocks, with 12 treatments and 4 replications, giving a total of 48 experimental lots. The treatments were: Haloxyfop-R Methyl Ester at dosages of 0.625, 1.25 and 2.50 g ha(-1); Glyphosate at dosages of 12.50, 25.00 and 50.00 g ha-1; 2,4-D dimethylamine salt at dosages of 100.00, 200.00 and 300.00 g ha(-1); Alterbane at a dosage of 500.00 g ha(-1); Salicylic acid at a dose of 100 g ha(-1); and a control. It was concluded that for the subdosages under test, the herbicides 2,4-D at medium dosage and Verdict at low dosage were shown to be the best treatments for conserving straw as ground cover under direct seeding.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Although the popularization of astronomy in the last decade and the International Year of Astronomy, celebrated in 2009, there's a great lack in respect of quality instruments for astronomical disclosure. Thinking in this research about it, we intend to recuperate and elucidate a technique long forgotten: the metal mirror amateur telescope, once was done in the first reflecting telescopes. However, with the resources available today and given the high purity of the materials, our results were better than that obtained by the pioneers. We developed and built a large aperture telescope (250 mm diameter) and very bright (focal ratio = 4.0), versatile and portable. In our study was described step by step the process to fabricate the telescope. Through its first images captured of the Moon, we can illustrate its versatility both for use in outreach events and for use in amateur astronomy, because it is a primary focus capture system and can run registration of various astronomical events

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Soft tissue recessions frequently cause esthetic disharmony and dissatisfaction. The results of coverage in peri-implant sites, in comparison with soft tissue coverage around a tooth, is less predictable. This clinical report describes the correction of an esthetic problem with a single-tooth implant-supported using a subepithelial connective tissue graft (SCTG) combined with the re-establishment of a new limit of gingival margin, and emergence crown profile. After anamnese and clinical exam it was observed an implant in the region of tooth 22 in vestibular position to alveolar ridge with a recession of 5 mm in its vestibular face. In the first cirurgical procedure the crown and the abutment were removed and a SCTG associated with a coronally positioned flap was performed in order to re-establish the limit of gingival margin. After 90 days, it was observed that the tissue in the implant site showed no adequate volume or thickness. Because of that, another SCTG was performed. The reopening procedure to install the healing cap was performed after 4 weeks. Then the prosthesis was installed. At 180 and 360 days postoperative, the implant adjacent tissue presented regular contour, color compatible with health and absence of bleeding. The patient was satisfied with the esthetic result. According to the clinical results and favorable esthetics it was possible to conclude that the use of ETC to correct an esthetic deficiency may be a feasible approach to establish new and stable peri-implant soft tissue contours.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The evolution of ceramic systems currently allows the manufacture of prosthesis similar to the natural teeth, meeting the expectations of patients. However, when using vitreous ceramic the color of substrate is significant for the esthetic result, requiring planning aesthetic cores when involved reconstruction of endodontically treated teeth without coronal structure. Thus, the aim of this study to describe a case report of aesthetic rehabilitation in upper anterior teeths using vitreous ceramic system for the reconstruction of elements: 11, 12, 21 and 22 after endodontically treated. It was emphasized the removal of crowns and manufacture of custom cast post and core with ceramic in coronal portion, prioritizing the aesthetic result. Through the clinical results observed can be seen that the use of custom cast post and core with ceramic in association lithium disilicate glass ceramics provided a satisfactory aesthetic result.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The association of mandibular distal extension removable partial dentures with an osteointegrated implant is a treatment option at hasn't been fully explored by modern rehabilitation dentistry yet. The objective of this study is to evaluate, by means of the bidimensional method of finite elements, the distribution of tension on the structures supporting the distal extension removable partial denture (DERPD), associated to a 10.0 x 3.75 mm osteointegrated implant with an ERA retention system, in alveolar ridges of different shapes. Eight models were created, representing, from a sagittal perspective: Model A (MA) – a half arch with a horizontal ridge without posterior support, with the presence of the lower left canine, and a conventional DERPD, with metallic support in the incisal aspect of this canine, as replacement for the first and second pre-molars and the first and second molars of the lower left half arch; Model B (MB) – similar to MA, but different because of the presence of a 3.75 x 10.00 mm implant with an associated ERA retention system in the posterior region of the DERPD base; Model C (MC) - similar to MA, however with a distally ascending ridge format; Model D (MD) – similar to MC, but different because there is an implant associated to a retention system; Model E (ME) - similar to MA, however with a distally descending ridge format; Model F (MF) – similar to ME, but ditfferent in the sense that there is an implant with an associated ERA retention system; Model G (MG) – similar to MA, however with a distally descending-ascending ridge format; Model H (MH) – similar to MG, but different in the sense that there is an implant with an associated ERA retention system. The finite element program ANSYS 9.0 was used to load the models with vertical forces of 50 N, on each cuspid tip. The format of distal descending edge (ME and MF) was that presented worse results, so in the models with conventional RPD as in the models with RPD associated to the implant and ERA system of retention, for the structures gingival mucosa and tooth support. 1) the distally descending ridge presented the most significant stress in the model with the conventional RPD (ME) or with a prosthesis associated to an implant (MF) and 2) the horizontal ridge (MB) provided more relief to the support structures, such as the tooth and the spongy bone, when there was an implant associated to an ERA retention system. The incorporation of the implants with the ERA system retention, in the posterior area of the toothless edge, it promotes larger stability and retention to PPREL, improving the patient's masticatory acting and, consequently, its comfort and function.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Beef quality control, particularly its sensory characteristics, is an important factor for producers and retailers in order to satisfy consumer’s choices. Sensory analysis is an important tool to evaluate attributes that cannot be measured by easily available instrumental techniques, as well as texture – tenderness and juiciness – whose human perception is more complete, through trained panels. The aim of this study was evaluate the use of a beef sensory analysis protocol in three different laboratories. Six commercial samples of different brands of aged beef and 14 samples from crossbred animals (Bonsmara × Nelore - 7 and Canchim × Nelore - 7), aged during 14 days were analyzed. The samples were distributed to each participant laboratory, where 7 to 12 panelists were trained. A sheet containing a 9 cm non-structured scale with 14 attributes was used. The attributes were brown colour (CMAR); aponevrosis (PNAP); hydration degree (GH); characteristic beef aroma (SCCB); salty taste (SS); liver flavour (SF); fat flavour (SG); metallic flavour (SM); tenderness (MZ); juiciness (SL); fibrosity (FBS) and liver texture (SF). Obtained data was analyzed using analysis of variance and principal component analysis (PCA). The results showed that there was no interaction between samples and laboratories, indicating that all of them responded in a similar manner in relation to the samples, except PNAP attribute, which was expected as meat is very non-uniform normally. Samples were well differentiated in all laboratories as it could be observed in PCA graphs. With proper training it is possible to use a standard protocol for beef sensory analysis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Engenharia Mecânica - FEG

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The activation of aluminum surface has the most various purposes as for example the search for the surface activation mechanism and the corrosion products by mercury ions. The objective of this work is to study the reactivity of the surface of aluminum metal when activated by mercury ions (Hg2+), with the consequent formation of an Al-Hg amalgam. Results demonstrate that the kinetics of the reaction, by measuring the mass change with time of the corrosion product formed between Al and Hg, and analysis by infrared spectroscopy (IR) that the product of the reaction between the amalgam, located on the surface, and the atmospheric oxygen is Al2O3 (aluminum hydroxide). The results also indicate that the kinetics of the reaction between the amalgam (Hg-Al) and atmospheric oxygen is of first order and reach a region where there is no more formation of product

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)