949 resultados para Alveolar reconstruction


Relevância:

20.00% 20.00%

Publicador:

Resumo:

O carcinoma bronquíolo-alveolar é um tipo de carcinoma broncogênico de crescimento insidioso, que surge nas paredes das vias aéreas distais e se dissemina utilizando o septo alveolar como um estroma, preservando a arquitetura pulmonar. Neste trabalho foram analisadas as tomografias computadorizadas de alta resolução de 17 pacientes com carcinoma bronquíolo-alveolar. Ao contrário do relatado na literatura, foram observados predomínio no sexo masculino (71%) e maior freqüência da associação das formas de consolidação e multinodular (53%) em relação à forma nodular solitária (12%), multinodular (12%) e de consolidação (23%). Os aspectos mais encontrados foram: áreas de consolidação (76%), broncograma aéreo (71%), áreas de baixa atenuação provavelmente devidas à presença de muco (60%), espessamento de septos interlobulares, opacidades em vidro fosco e nódulos confluentes (54% cada), e pavimentação em mosaico (36%). Os nódulos cavitados, a atelectasia, o sinal do halo e o aspecto de "árvore em brotamento" foram observados em apenas um caso cada.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the behavior of complex information in the Fresnel domain, taking into account the limited capability to display complex values of liquid crystal devices when they are used as holographic displays. To do this analysis we study the reconstruction of Fresnel holograms at several distances using the different parts of the complex distribution. We also use the information adjusted with a method that combines two configurations of the devices in an adding architecture. The results of the error analysis show different behavior for the reconstructions when using the different methods. Simulated and experimental results are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Os autores apresentam dois casos de microlitíase alveolar pulmonar em gêmeos monozigóticos. Os principais achados obtidos em exames radiográficos e de tomografia computadorizada (técnica de alta resolução) são enfatizados, com base em breve revisão literária.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The purpose of this study is to determine the possible differences in deflection between two needles of same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The initial working hypothesis was that greater deflection may be expected with larger internal gauge needles. Study design: Four clinicians subjected 346 patients to inferior alveolar nerve block and infiltrating anesthesia of the buccal nerve trajectory for the surgical or conventional extraction of the lower third molar. A nonautoaspirating syringe system with 2 types of needle was used: a standard 27-gauge x 35-mm needle with an internal gauge of 0.215 mm or an XL Monoprotect® 27-gauge x 35-mm needle with an internal gauge of 0.265 mm. The following information was systematically recorded for each patient: needle type, gender, anesthetic technique (direct or indirect truncal block) and the number of bone contacts during the procedure, the patient-extraction side, the practitioner performing the technique, and blood aspiration (either positive or negative). Results: 346 needles were used in total. 190 were standard needles (27-gauge x 35-mm needle with an internal gauge of 0.215 mm) and 156 were XL Monoprotect®. Incidence of deflection was observed in 49.1% of cases (170 needles) where 94 were standard needles and 76 XL Monoprotect®. Needle torsion ranged from 0º and 6º. Conclusions: No significant differences were recorded in terms of deflection and internal gauge, operator, patient-extraction side, the anesthetic technique involved and the number of bone contacts during the procedure

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Le nombre d'examens tomodensitométriques (Computed Tomography, CT) effectués chaque année étant en constante augmentation, différentes techniques d'optimisation, dont les algorithmes de reconstruction itérative permettant de réduire le bruit tout en maintenant la résolution spatiale, ont étés développées afin de réduire les doses délivrées. Le but de cette étude était d'évaluer l'impact des algorithmes de reconstruction itérative sur la qualité image à des doses effectives inférieures à 0.3 mSv, comparables à celle d'une radiographie thoracique. Vingt CT thoraciques effectués à cette dose effective ont été reconstruits en variant trois paramètres: l'algorithme de reconstruction, rétroprojection filtrée versus reconstruction itérative iDose4; la matrice, 5122 versus 7682; et le filtre de résolution en densité (mou) versus spatiale (dur). Ainsi, 8 séries ont été reconstruites pour chacun des 20 CT thoraciques. La qualité d'image de ces 8 séries a d'abord été évaluée qualitativement par deux radiologues expérimentés en aveugle en se basant sur la netteté des parois bronchiques et de l'interface entre le parenchyme pulmonaire et les vaisseaux, puis quantitativement en utilisant une formule de merit, fréquemment utilisée dans le développement de nouveaux algorithmes et filtres de reconstruction. La performance diagnostique de la meilleure série acquise à une dose effective inférieure à 0.3 mSv a été comparée à celle d'un CT de référence effectué à doses standards en relevant les anomalies du parenchyme pulmonaire. Les résultats montrent que la meilleure qualité d'image, tant qualitativement que quantitativement a été obtenue en utilisant iDose4, la matrice 5122 et le filtre mou, avec une concordance parfaite entre les classements quantitatif et qualitatif des 8 séries. D'autre part, la détection des nodules pulmonaires de plus de 4mm étaient similaire sur la meilleure série acquise à une dose effective inférieure à 0.3 mSv et le CT de référence. En conclusion, les CT thoraciques effectués à une dose effective inférieure à 0.3 mSv reconstruits avec iDose4, la matrice 5122 et le filtre mou peuvent être utilisés avec confiance pour diagnostiquer les nodules pulmonaires de plus de 4mm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Switzerland is a region in which alveolar echinococcosis (AE) is endemic. Studies evaluating outcomes after liver resection (LR) for AE are scarce. The aim of this study was to assess the short- and long-term outcomes of AE patients after LR in a single tertiary referral center. METHODS: We retrospectively analyzed data pertaining to all patients with liver AE who were treated with LR at our institution between January 1992 and December 2013. Patient demographics, intraoperative data, extent of LR procedures (major vs. minor LR), postoperative outcomes, and negative histological margin (R0) resection rate were recorded in a database. Recurrence rates after LR were analyzed. RESULTS: LR was performed in 59 patients diagnosed with hepatic AE (56 complete surgeries, 3 reduction surgeries). Postoperative morbidity and mortality were observed in 34 % (25 % grade I-II, 9 % grade III-IV) and 2 % of the patients, respectively. R0 (complete) resection rate was 71 % (n = 42), and R1/R2 resection rate was 29 % (n = 17). Extra-hepatic recurrence occurred in 1 case (lung) after R0 resection. In cases of R1/R2 resection, 7 intra-hepatic disease progressions occurred with a median time of 10 months (IQR 6-11 months). Long-term (more than 1 year) benzimidazole treatment stabilized the disease in 64 % (9/14) of patients with R1 status. The overall survival rate was 97 %. CONCLUSIONS: Liver AE can be safely and definitively treated with LR, provided that R0 resection is achieved. In cases of R1 resection, benzimidazole therapy seems to be effective in stabilizing the intra-hepatic disease and preventing extra-hepatic recurrence.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality at CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: One of the most frequent complications of pancreaticoduodenectomy (PD) is delayed gastric emptying (DGE). The study aim was to evaluate the impact of the type of gastro/duodenojejunal reconstruction (antecolic vs. retrocolic) after PD on DGE incidence. METHODS: A systematic review was made according to the PRISMA guidelines. Randomized controlled trials (RCTs) comparing antecolic vs. retrocolic reconstruction were included irrespective of the PD techniques. A meta-analysis was then performed. RESULTS: Six RCTs were included for a total of 588 patients. The overall quality was good. General risk of bias was low. DGE was not statistically significantly different between the antecolic and retrocolic group (OR 0.6, 95% CI 0.31-1.16, p = 0.13). The other main surgery-related complications (pancreatic fistula, hemorrhage, intra-abdominal abscess, bile leak and wound infection) were not dependent on the reconstruction route (OR 0.84, 95% CI 0.41-1.70, p = 0.63). No statistically significant difference in terms of length of hospital stay was found between the 2 groups. There was also no difference of DGE incidence if only pylorus-preserving PD was considered and between the DGE grades A, B or C. CONCLUSION: This meta-analysis shows that antecolic reconstruction after PD is not superior to retrocolic reconstruction in terms of DGE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Computed tomography (CT) is a modality of choice for the study of the musculoskeletal system for various indications including the study of bone, calcifications, internal derangements of joints (with CT arthrography), as well as periprosthetic complications. However, CT remains intrinsically limited by the fact that it exposes patients to ionizing radiation. Scanning protocols need to be optimized to achieve diagnostic image quality at the lowest radiation dose possible. In this optimization process, the radiologist needs to be familiar with the parameters used to quantify radiation dose and image quality. CT imaging of the musculoskeletal system has certain specificities including the focus on high-contrast objects (i.e., in CT of bone or CT arthrography). These characteristics need to be taken into account when defining a strategy to optimize dose and when choosing the best combination of scanning parameters. In the first part of this review, we present the parameters used for the evaluation and quantification of radiation dose and image quality. In the second part, we discuss different strategies to optimize radiation dose and image quality of CT, with a focus on the musculoskeletal system and the use of novel iterative reconstruction techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fetal MRI reconstruction aims at finding a high-resolution image given a small set of low-resolution images. It is usually modeled as an inverse problem where the regularization term plays a central role in the reconstruction quality. Literature has considered several regularization terms s.a. Dirichlet/Laplacian energy [1], Total Variation (TV)based energies [2,3] and more recently non-local means [4]. Although TV energies are quite attractive because of their ability in edge preservation, standard explicit steepest gradient techniques have been applied to optimize fetal-based TV energies. The main contribution of this work lies in the introduction of a well-posed TV algorithm from the point of view of convex optimization. Specifically, our proposed TV optimization algorithm for fetal reconstruction is optimal w.r.t. the asymptotic and iterative convergence speeds O(1/n(2)) and O(1/root epsilon), while existing techniques are in O(1/n) and O(1/epsilon). We apply our algorithm to (1) clinical newborn data, considered as ground truth, and (2) clinical fetal acquisitions. Our algorithm compares favorably with the literature in terms of speed and accuracy.