976 resultados para Accuracy of Hotel Feasibility Study Projections


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Autologous hematopoietic stem cell transplantation is a conduct used to treat some hematologic diseases and to consolidate the treatment of others. In the field of nursing, the few published scientific studies on nursing care and early hospital discharge of transplant patients are deficient. Knowledge about the diseases treated using hematopoietic stem cell transplantation, providing guidance to patients and caregivers and patient monitoring are important nursing activities in this process. Guidance may contribute to long-term goals through patients' short-term needs. To analyze the results of early hospital discharge on the treatment of patients submitted to autologous transplantation and the influence of nursing care on this conduct. A retrospective, quantitative, descriptive and transversal study was conducted. The hospital records of 112 consecutive patients submitted to autologous transplantation in the period from January to December 2009 were revisited. Of these, 12 patients, who remained in hospital for more than ten days after transplantation, were excluded from the study. The medical records of 100 patients with a median age of 48.5 years (19-69 years) were analyzed. All patients were mobilized and hematopoietic stem cells were collected by leukapheresis. The most common conditioning regimes were BU12Mel100 and BEAM 400. Toxicity during conditioning was easily managed in the outpatient clinic. Gastrointestinal toxicity, mostly Grades I and II, was seen in 69% of the patients, 62% of patients had diarrhea, 61% of the patients had nausea and vomiting and 58% had Grade I and II mucositis. Ten patients required hospitalization due to the conditioning regimen. Febrile neutropenia was seen in 58% of patients. Two patients died before Day +60 due to infections, one with aplasia. The median times to granulocyte and platelet engraftment were 12 days and 15 days, respectively, with median red blood cell and platelet transfusions until discharge of three and four units, respectively. Twenty-three patients required rehospitalization before being discharged from the outpatient clinic. The median time to granulocyte engraftment was 12 days and during the aplasia phase few patients were hospitalized or suffered infections. The toxicity of the conditioning was the leading cause of rehospitalization. The nursing staff participated by providing guidance to patients and during the mobilization, transplant and outpatient follow-up phases, thus helping to successfully manage toxicity.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Product miniaturization for applications in fields such as biotechnology, medical devices, aerospace, optics and communications has made the advancement of micromachining techniques essential. Machining of hard and brittle materials such as ceramics, glass and silicon is a formidable task. Rotary ultrasonic machining (RUM) is capable of machining these materials. RUM is a hybrid machining process which combines the mechanism of material removal of conventional grinding and ultrasonic machining. Downscaling of RUM for micro scale machining is essential to generate miniature features or parts from hard and brittle materials. The goal of this thesis is to conduct a feasibility study and to develop a knowledge base for micro rotary ultrasonic machining (MRUM). Positive outcome of the feasibility study led to a comprehensive investigation on the effect of process parameters. The effect of spindle speed, grit size, vibration amplitude, tool geometry, static load and coolant on the material removal rate (MRR) of MRUM was studied. In general, MRR was found to increase with increase in spindle speed, vibration amplitude and static load. MRR was also noted to depend upon the abrasive grit size and tool geometry. The behavior of the cutting forces was modeled using time series analysis. Being a vibration assisted machining process, heat generation in MRUM is low which is essential for bone machining. Capability of MRUM process for machining bone tissue was investigated. Finally, to estimate the MRR a predictive model was proposed. The experimental and the theoretical results exhibited a matching trend.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to examine the reliability, validity and classification accuracy of the South Oaks Gambling Screen (SOGS) in a sample of the Brazilian population. Participants in this study were drawn from three sources: 71 men and women from the general population interviewed at a metropolitan train station; 116 men and women encountered at a bingo venue; and 54 men and women undergoing treatment for gambling. The SOGS and a DSM-IV-based instrument were applied by trained researchers. The internal consistency of the SOGS was 0.75 according to the Cronbach`s alpha model, and construct validity was good. A significant difference among groups was demonstrated by ANOVA (F ((2.238)) = 221.3, P < 0.001). The SOGS items and DSM-IV symptoms were highly correlated (r = 0.854, P < 0.01). The SOGS also presented satisfactory psychometric properties: sensitivity (100), specificity (74.7), positive predictive rate (60.7), negative predictive rate (100) and misclassification rate (0.18). However, a cut-off score of eight improved classification accuracy and reduced the rate of false positives: sensitivity (95.4), specificity (89.8), positive predictive rate (78.5), negative predictive rate (98) and misclassification rate (0.09). Thus, the SOGS was found to be reliable and valid in the Brazilian population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Introduction: The widespread screening programs prompted a decrease in prostate cancer stage at diagnosis, and active surveillance is an option for patients who may harbor clinically insignificant prostate cancer (IPC). Pathologists include the possibility of an IPC in their reports based on the Gleason score and tumor volume. This study determined the accuracy of pathological data in the identification of IPC in radical prostatectomy (RP) specimens. Materials and Methods: Of 592 radical prostatectomy specimens examined in our laboratory from 2001 to 2010, 20 patients harbored IPC and exhibited biopsy findings suggestive of IPC. These biopsy features served as the criteria to define patients with potentially insignificant tumor in this population. The results of the prostate biopsies and surgical specimens of the 592 patients were compared. Results: The twenty patients who had IPC in both biopsy and RP were considered real positive cases. All patients were divided into groups based on their diagnoses following RP: true positives (n = 20), false positives (n = 149), true negatives (n = 421), false negatives (n = 2). The accuracy of the pathological data alone for the prediction of IPC was 91.4%, the sensitivity was 91% and the specificity was 74%. Conclusion: The identification of IPC using pathological data exclusively is accurate, and pathologists should suggest this in their reports to aid surgeons, urologists and radiotherapists to decide the best treatment for their patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This ex vivo study evaluated the effect of pre-flaring and file size on the accuracy of the Root ZX and Novapex electronic apex locators (EALs). Material and methods: The actual working length (WL) was set 1 mm short of the apical foramen in the palatal root canals of 24 extracted maxillary molars. The teeth were embedded in an alginate mold, and two examiners performed the electronic measurements using #10, #15, and #20 K-files. The files were inserted into the root canals until the "0.0" or "APEX" signals were observed on the LED or display screens for the Novapex and Root ZX, respectively, retracting to the 1.0 mark. The measurements were repeated after the pre-flaring using the S1 and SX Pro-Taper instruments. Two measurements were performed for each condition and the means were used. Intra-class correlation coefficients (ICCs) were calculated to verify the intra-and inter-examiner agreement. The mean differences between the WL and electronic length values were analyzed by the three-way ANOVA test (p<0.05). Results: ICCs were high (>0.8) and the results demonstrated a similar accuracy for both EALs (p>0.05). Statistically significant accurate measurements were verified in the pre-flared canals, except for the Novapex using a #20 K-file. Conclusions: The tested EALs showed acceptable accuracy, whereas the pre-flaring procedure revealed a more significant effect than the used file size.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To examine the accuracy of a screening programme for potentially malignant disorders of the oral mucosa by visual inspection in primary health care. Materials and Methods: The study was based on secondary data from the Primary Care Information System maintained by seven units of family health in Sao Paulo City managed by a non-governmental agency. The reference population was composed of 15,072 residents 50 years old or more of both genders. The study population comprised 2,980 individuals. During screening in community settings, the oral mucosa was examined by trained dentists and distributed into two categories: (a) screen negative (b) screen positive. All participants underwent comprehensive clinical exams by a general dental practitioner supervised by a specialist. Individual records were grouped in a working dataset. Point and 95% confidence interval estimates were calculated regarding measures of sensitivity (Se), specificity (Sp) and positive and negative predictive values (PPV and NPV, respectively). Results: 18.0% of the population was considered screen positive. A total of 133 lesions (4.5%) were identified and 8 cases of oral cancer were confirmed, which corresponded to a prevalence rate of 27 cases in 10,000 people, a much higher rate than expected. The measures found were Se: 91.7% (85.3-95.6), Sp: 85.4% (84.1-86.7), PPV: 22.7% (19.3-26.5), NPV: 99.5% (99.2-99.8). The visual screen presented high accuracy. Conclusion: The test presented high sensibility and specificity values. From a public health point of view, the high accuracy levels showed the importance of oral health teams on family health strategy for more comprehensive primary care. Targeting risk groups and delegating the screening to community health agents may improve PPV and coverage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To compare, in vivo, the accuracy of conventional and digital radiographic methods in determining root canal working length. Material and Methods: Twenty-five maxillary incisor or canine teeth from 22 patients were used in this study. Considering the preoperative radiographs as the baseline, a 25 K file was inserted into the root canal to the point where the Root ZX electronic apex locator indicated the APEX measurement in the screen. From this measurement, 1 mm was subtracted for positioning the file. The radiographic measurements were made using a digital sensor (Digora 1.51) or conventional type-E films, size 2, following the paralleling technique, to determine the distance of the file tip and the radiographic apex. Results: The Student "t" test indicated mean distances of 1.11 mm to conventional and 1.20 mm for the digital method and indicated a significant statistical difference (p<0.05). Conclusions: The conventional radiographic method was found to be superior to the digital one in determining the working length of the root canal.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To determine the accuracy of the Timed Up and Go Test (TUGT) for screening the risk of falls among community-dwelling elderly individuals. Method: This is a prospective cohort study with a randomly by lots without reposition sample stratified by proportional partition in relation to gender involving 63 community-dwelling elderly individuals. Elderly individuals who reported having Parkinson's disease, a history of transitory ischemic attack, stroke and with a Mini Mental State Exam lower than the expected for the education level, were on a wheelchair and that reported a single fall in the previous six months were excluded. The TUGT, a mobility test, was the measure of interested and the occurrence of falls was the outcome. The performance of basic activities of daily living (ADL) and instrumental activities of daily living (IADL) was determined through the Older American Resources and Services, and the socio-demographic and clinical data were determined through the use of additional questionnaires. Receiver Operating Characteristic Curves were used to analyze the sensitivity and specificity of the TUGT. Results: Elderly individuals who fell had greater difficulties in ADL and IADL (p<0.01) and a slower performance on the TUGT (p=0.02). No differences were found in socio-demographic and clinical characteristics between fallers and non- fallers. Considering the different sensitivity and specificity, the best predictive value for discriminating elderly individuals who fell was 12.47 seconds [(RR= 3.2) 95% CI: 1.3- 7.7]. Conclusions: The TUGT proved to be an accurate measure for screening the risk of falls among elderly individuals. Although different from that reported in the international literature, the 12.47 second cutoff point seems to be a better predictive value for Brazilian elderly individuals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Neoadjuvant chemoradiation (CRT) therapy may result in significant tumor regression in patients with rectal cancer. Patients who develop complete tumor regression have been managed by treatment strategies that are alternatives to standard total mesorectal excision. Therefore, assessment of tumor response with positron emission tomography/computed tomography (PET/CT) after neoadjuvant treatment may offer relevant information for the selection of patients to receive alternative treatment strategies. METHODS: Patients with clinical T2 (cT2) through cT4NxM0 rectal adenocarcinoma were included prospectively. Neoadjuvant therapy consisted of 54 grays of radiation and 5-fluorouracil-based chemotherapy. Baseline PET/CT studies were obtained before CRT followed by PET/CT studies at 6 weeks and 12 weeks after the completion of CRT. Clinical assessment was performed at 12 weeks after CRT completion. PET/CT results were compared with clinical and pathologic data. RESULTS: In total, 99 patients were included in the study. Twenty-three patients were complete responders (16 had a complete clinical response, and 7 had a complete pathologic response). The PET/CT response evaluation at 12 weeks indicated that 18 patients had a complete response, and 81 patients had an incomplete response. There were 5 false-negative and 10 false-positive PET/CT results. PET/CT for the detection of residual cancer had 93% sensitivity, 53% specificity, a 73% negative predictive value, an 87% positive predictive value, and 85% accuracy. Clinical assessment alone resulted in an accuracy of 91%. PET/CT information may have detected misdiagnoses made by clinical assessment alone, improving overall accuracy to 96%. CONCLUSIONS: Assessment of tumor response at 12 weeks after CRT completion with PET/CT imaging may provide a useful additional tool with good overall accuracy for the selection of patients who may avoid unnecessary radical resection after achieving a complete clinical response. Cancer 2012;35013511. (C) 2011 American Cancer Society.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Abstract Background Metastases to the pancreas are rare, and usually mistaken for primary pancreatic cancers. This study aimed to describe the histology results of solid pancreatic tumours obtained by endoscopic ultrasound-guided fine-needle aspiration (EUS-FNA) for diagnosis of metastases to the pancreas. Methods In a retrospective review, patients with pancreatic solid tumours and history of previous extrapancreatic cancer underwent EUS-FNA from January/1997 to December/2010. Most patients were followed-up until death and some of them were still alive at the end of the study. The performance of EUS-FNA for diagnosis of pancreatic metastases was analyzed. Symptoms, time frame between primary tumour diagnosis and the finding of metastases, and survival after diagnosis were also analyzed. Results 37 patients underwent EUS-FNA for probable pancreas metastases. Most cases (65%) presented with symptoms, especially upper abdominal pain (46%). Median time between detection of the first tumour and the finding of pancreatic metastases was 36 months. Metastases were confirmed in 32 (1.6%) cases, 30 of them by EUS-FNA, and 2 by surgery. Other 5 cases were non-metastatic. Most metastases were from lymphoma, colon, lung, and kidney. Twelve (32%) patients were submitted to surgery. Median survival after diagnosis of pancreatic metastases was 9 months, with no difference of survival between surgical and non-surgical cases. Sensitivity, specificity, positive and negative predictive values, and accuracy of EUS-FNA with histology analysis of the specimens for diagnosis of pancreatic metastases were, respectively, 93.8%, 60%, 93.8%, 60% and 89%. Conclusion EUS-FNA with histology of the specimens is a sensitive and accurate method for definitive diagnosis of metastatic disease in patients with a previous history of extrapancreatic malignancies.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate in vivo the clinical applicability of two electronic apex locators (EALs) - Apex (Septodont) and iPex (NSK) - in different groups of human teeth by using radiography. The working lengths (WLs) of 100 root canals were determined electronically. The EAL to be used first was chosen randomly and a K-file was inserted into the root canal until the EAL display indicated the location of the apical constriction (0 mm). The K-file was fixed to the tooth and a periapical radiograph was taken using a radiographic film holder. The K-file was removed and the WL was measured. The same procedure was repeated using the other EAL. Radiographs were examined with the aid of a light-box with lens of ×4 magnification by two blinded experienced endodontists. The distance between the file tip and the root apex was recorded as follows: (A) +1 to 0 mm, (B) -0.1 to 0.5 mm, (C) -0.6 to 1 mm, (D) -1.1 to 1.5 mm, and (E) -1.6 mm or greater. For statistical purposes, these scores were divided into 2 subgroups according to the radiographic apex: acceptable (B, C, and D) and non-acceptable (A and E). Statistically significant differences were not found between the results of Apex and iPex in terms of acceptable and non-acceptable measurements (p>0.05) or in terms of the distance recorded from file tip and the radiographic apex (p>0.05). Apex and iPex EALs provided reliable measurements for WL determination for endodontic therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The present study evaluated the interchangeability of prosthetic components for external hexagon implants by measuring the precision of the implant/abutment (I/A) interface with scanning electron microscopy. Ten implants for each of three brands (SIN, Conexão, Neodent) were tested with their respective abutments (milled CoCr collar rotational and non-rotational) and another of an alternative manufacturer (Microplant) in randomly arranged I/A combinations. The degree of interchangeability between the various brands of components was defined using the original abutment interface gap with its respective implant as the benchmark dimension. Accordingly, when the result for a given component placed on an implant was equal to or smaller then that gap measured when the original component of the same brand as the implant was positioned, interchangeability was considered valid. Data were compared with the Kruskal-Wallis test at 5% significance level. Some degree of misfit was observed in all specimens. Generally, the non-rotational component was more accurate than its rotational counterpart. The latter samples ranged from 0.6-16.9 µm, with a 4.6 µm median; and the former from 0.3-12.9 µm, with a 3.4 µm median. Specimens with the abutment and fixture from Conexão had larger microgap than the original set for SIN and Neodent (p<0.05). Even though the latter systems had similar results with their respective components, their interchanged abutments did not reproduce the original accuracy. The results suggest that the alternative brand abutment would have compatibility with all systems while the other brands were not completely interchangeable.