362 resultados para Accelerometer


Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study was carried out to detect differences in locomotion and feeding behavior in lame (group L; n = 41; gait score ≥ 2.5) and non-lame (group C; n = 12; gait score ≤ 2) multiparous Holstein cows in a cross-sectional study design. A model for automatic lameness detection was created, using data from accelerometers attached to the hind limbs and noseband sensors attached to the head. Each cow's gait was videotaped and scored on a 5-point scale before and after a period of 3 consecutive days of behavioral data recording. The mean value of 3 independent experienced observers was taken as a definite gait score and considered to be the gold standard. For statistical analysis, data from the noseband sensor and one of two accelerometers per cow (randomly selected) of 2 out of 3 randomly selected days was used. For comparison between group L and group C, the T-test, the Aspin-Welch Test and the Wilcoxon Test were used. The sensitivity and specificity for lameness detection was determined with logistic regression and ROC-analysis. Group L compared to group C had significantly lower eating and ruminating time, fewer eating chews, ruminating chews and ruminating boluses, longer lying time and lying bout duration, lower standing time, fewer standing and walking bouts, fewer, slower and shorter strides and a lower walking speed. The model considering the number of standing bouts and walking speed was the best predictor of cows being lame with a sensitivity of 90.2% and specificity of 91.7%. Sensitivity and specificity of the lameness detection model were considered to be very high, even without the use of halter data. It was concluded that under the conditions of the study farm, accelerometer data were suitable for accurately distinguishing between lame and non-lame dairy cows, even in cases of slight lameness with a gait score of 2.5.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Problématique : Les prématurés évoluent dans l’unité néonatale qui présente une intensité lumineuse parfois forte et variable, ce qui a pour effet de provoquer une instabilité physiologique, ainsi qu’une augmentation du niveau d’activité motrice chez ces derniers. Par ailleurs, le contrôle de l’éclairage à l’unité néonatale favorise la stabilité physiologique et réduit le niveau d’activité motrice des prématurés. Deux méthodes de contrôle de l’éclairage ont été étudiées, soit l’éclairage tamisé constant et l’éclairage cyclique. Or, la méthode de contrôle de l’éclairage la plus appropriée au système nerveux immature des prématurés est inconnue et il y a ambivalence en ce qui concerne les résultats des études ayant évalué ces deux modes de contrôle de l’éclairage. But : Le but de cette étude était de mesurer les effets de l’éclairage cyclique versus l’éclairage tamisé constant sur la stabilité physiologique et le niveau d’activité motrice de prématurés nés entre 28 et 32 semaines d’âge gestationnel. Méthode : Un essai clinique randomisé a été réalisé. Les 38 prématurés recrutés dans une unité néonatale de niveaux II et III d’un hôpital universitaire, ont été randomisés dans l’un des deux groupes d’intervention, soit le groupe exposé à l’éclairage tamisé constant ou celui exposé à l’éclairage cyclique. Ces deux types d’éclairage ont été appliqués pendant 24 heures. La stabilité physiologique a été mesurée par le score Stability of the Cardio Respiratory System in Premature Infants (SCRIP) et le niveau d’activité motrice a été mesuré avec un accéléromètre (Actiwatch®). L’intensité lumineuse à laquelle les prématurés ont été exposés a été mesurée de façon continue à l’intérieur de l’incubateur à l’aide d’un photomètre. Résultats : L’analyse des données révèle qu’il n’y aucune différence significative entre les deux groupes d’intervention en ce qui a trait à la stabilité physiologique (valeur-p du score SCRIP de 0,54 à 0,96) et au niveau d’activité motrice (valeur-p de 0,09 à 0,88). Les participants des deux groupes ont manifesté une stabilité physiologique et un niveau d’activité motrice comparables. Conclusion : Des interventions de contrôle de l’éclairage doivent être adoptées à l’unité néonatale, que ce soit des interventions qui permettent la mise en œuvre de l’éclairage cyclique ou de l’éclairage tamisé constant, dans le but de favoriser l’adaptation du prématuré à l’environnement de l’unité néonatale. Des recherches additionnelles sont requises afin d’identifier la méthode de contrôle de l’éclairage (éclairage cyclique ou éclairage tamisé constant) qui doit être implantée à l’unité néonatale.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Thesis (Master's)--University of Washington, 2016-06

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Physical activity (PA) is relevant to the prevention and management of many health conditions in family practice. There is a need for an efficient, reliable, and valid assessment tool to identify patients in need of PA interventions. Methods: Twenty-eight family physicians in three Australian cities assessed the PA of their adult patients during 2004 using either a two- (2Q) or three-question (3Q) assessment. This was administered again approximately 3 days later to evaluate test-retest reliability. Concurrent validity was evaluated by measuring agreement with the Active Australia Questionnaire, and criterion validity by comparison with 7-day Computer Science Applications, Inc. (CSA) accelerometer counts. Results: A total of 509 patients participated, with 428 (84%) completing a repeat assessment, and 415 (82%) accelerometer monitoring. The brief assessments had moderate test-retest reliability (2Q k = 58.0%, 95% confidence interval [CI] = 47.2-68.8%; 3Q k = 55.6%, 95% CI = 43.8-67.4%); fair to moderate concurrent validity (2Q k = 46.7%, 95% CI = 35.657.9%; 3Q k = 38.7%, 95% CI = 26.4-51.1%); and poor to fair criterion validity (2Q k = 18.2%, 95% CI = 3.9-32.6%; 3Q k = 24.3%, 95% CI = 11.6-36.9%) for identifying patients as sufficiently active. A four-level scale of PA derived from the PA assessments was significantly correlated with accelerometer minutes (2Q rho = 0.39, 95% CI = 0.28-0.49; 3Q rho = 0.31, 95% CI = 0.18-0.43). Physicians reported that the assessments took I to 2 minutes to complete. Conclusions: Both PA assessments were feasible to use in family practice, and were suitable for identifying the least active patients. The 2Q assessment was preferred by clinicians and may be most appropriate for dissemination.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the validity of a uniaxial accelerometer (MTI Actigraph) for measuring physical activity in people with acquired brain injury (ABI) using portable indirect calorimetry (Cosmed K4b(2)) as a criterion measure. Methods: Fourteen people with ABI and related gait pattern impairment (age 32 +/- 8 yr) wore an MTI Actigraph that measured activity (counts(.)min-(1)) and a Cosmed K4b(2) that measured oxygen consumption (mL(.)kg(-1.)min(-1)) during four activities: quiet sitting (QS) and comfortable paced (CP), brisk paced (BP), and fast paced (FP) walking. MET levels were predicted from Actigraph counts using a published equation and compared with Cosmed measures. Predicted METs for each of the 56 activity bouts (14 participants X 4 bouts) were classified (light, moderate, vigorous, or very vigorous intensity) and compared with Cosmed-based classifications. Results: Repeated-measures ANOVA indicated that walking condition intensities were significantly different (P < 0.05) and the Actigraph detected the differences. Overall correlation between measured and predicted METs was positive, moderate, and significant (r = 0.74). Mean predicted METs were not significantly different from measured for CP and BP, but for FP walking, predicted METs were significantly less than measured (P < 0.05). The Actigraph correctly classified intensity for 76.8% of all activity bouts and 91.5% of light- and moderate-intensity bouts. Conclusions: Actigraph counts provide a valid index of activity across the intensities investigated in this study. For light to moderate activity, Actigraph-based estimates of METs are acceptable for group-level analysis and are a valid means of classifying activity intensity. The Actigraph significantly underestimated higher intensity activity, although, in practice, this limitation will have minimal impact on activity measurement of most community-dwelling people with ABI.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Two force balance techniques for use in hypersonic impulse facilities are compared by measuring the drag force on a 30&DEG; semi-apex-angle blunt cone model in a hypersonic shock tunnel at a free stream Mach number of 5.75. An accelerometer-based balance and a stress-wave force balance were tested simultaneously on the same model to measure the drag force. It was found that drag force measurements could be made using both techniques in a flow with a 450-μ s test period. The measured drag forces compared well with the theoretical values estimated using Newtonian theory.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: To evaluate the reliability and validity of a brief physical activity assessment tool suitable for doctors to use to identify inactive patients in the primary care setting. Methods: Volunteer family doctors (n = 8) screened consenting patients (n = 75) for physical activity participation using a brief physical activity assessment tool. Inter-rater reliability was assessed within one week (n = 71). Validity was assessed against an objective physical activity monitor (computer science and applications accelerometer; n = 42). Results: The brief physical activity assessment tool produced repeatable estimates of sufficient total physical activity, correctly classifying over 76% of cases (kappa 0.53, 95% confidence interval (CI) 0.33 to 0.72). The validity coefficient was reasonable (kappa 0.40, 95% CI 0.12 to 0.69), with good percentage agreement (71%). Conclusions: The brief physical activity assessment tool is a reliable instrument, with validity similar to that of more detailed self report measures of physical activity. It is a tool that can be used efficiently in routine primary healthcare services to identify insufficiently active patients who may need physical activity advice.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This study was conducted to devise a new individual calibration method to enhance MTI accelerometer estimation of free-living level walking speed. Method: Five female and five male middle-aged adults walked 400 m at 3.5, 4.5, and 5.5 km(.)h(-1), and 800 in at 6.5 km(.)h(-1) on an outdoor track, following a continuous protocol. Lap speed was controlled by a global positioning system (GPS) monitor. MTI counts-to-speed calibration equations were derived for each trial, for each subject for four such trials with each of four MTI, for each subject for the average MTI. and for the pooled data. Standard errors of the estimate (SEE) with and without individual calibration were compared. To assess accuracy of prediction of free-living walking speed, subjects also completed a self-paced, brisk 3-km walk wearing one of the four MTI, and differences between actual and predicted walking speed with and without individual calibration were examined. Results: Correlations between MTI counts and walking speed were 0.90 without individual calibration, 0.98 with individual calibration for the average MTI. and 0.99 with individual calibration for a specific MTI. The SEE (mean +/- SD) was 0.58 +/- 0.30 km(.)h(-1) without individual calibration, 0.19 +/- 0.09 km h(-1) with individual calibration for the average MTI monitor, and 0.16 +/- 0.08 km(.)h(-1) with individual calibration for a specific MTI monitor. The difference between actual and predicted walking speed on the brisk 3-km walk was 0.06 +/- 0.25 km(.)h(-1) using individual calibration and 0.28 +/- 0.63 km(.)h(-1) without individual calibration (for specific accelerometers). Conclusion: MTI accuracy in predicting walking speed without individual calibration might be sufficient for population-based studies but not for intervention trials. This individual calibration method will substantially increase precision of walking speed predicted from MTI counts.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: This Study evaluated the predictive validity of three previously published ActiGraph energy expenditure (EE) prediction equations developed for children and adolescents. Methods: A total of 45 healthy children and adolescents (mean age: 13.7 +/- 2.6 yr) completed four 5-min activity trials (normal walking. brisk walking, easy running, and fast running) in ail indoor exercise facility. During each trial, participants were all ActiGraph accelerometer oil the right hip. EE was monitored breath by breath using the Cosmed K4b(2) portable indirect calorimetry system. Differences and associations between measured and predicted EE were assessed using dependent t-tests and Pearson correlations, respectively. Classification accuracy was assessed using percent agreement, sensitivity, specificity, and area under the receiver operating characteristic (ROC) curve, Results: None of the equations accurately predicted mean energy expenditure during each of the four activity trials. Each equation, however, accurately predicted mean EE in at least one activity trial. The Puyau equation accurately predicted EE during slow walking. The Trost equation accurately predicted EE during slow running. The Freedson equation accurately predicted EE during fast running. None of the three equations accurately predicted EE during brisk walking. The equations exhibited fair to excellent classification accuracy with respect to activity intensity. with the Trost equation exhibiting the highest classification accuracy and the Puyau equation exhibiting the lowest. Conclusions: These data suggest that the three accelerometer prediction equations do not accurately predict EE on a minute-by-minute basis in children and adolescents during overground walking and running. The equations maybe, however, for estimating participation in moderate and vigorous activity.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This research develops a low cost remote sensing system for use in agricultural applications. The important features of the system are that it monitors the near infrared and it incorporates position and attitude measuring equipment allowing for geo-rectified images to be produced without the use of ground control points. The equipment is designed to be hand held and hence requires no structural modification to the aircraft. The portable remote sensing system consists of an inertia measurement unit (IMU), which is accelerometer based, a low-cost GPS device and a small format false colour composite digital camera. The total cost of producing such a system is below GBP 3000, which is far cheaper than equivalent existing systems. The design of the portable remote sensing device has eliminated bore sight misalignment errors from the direct geo-referencing process. A new processing technique has been introduced for the data obtained from these low-cost devices, and it is found that using this technique the image can be matched (overlaid) onto Ordnance Survey Master Maps at an accuracy compatible with precision agriculture requirements. The direct geo-referencing has also been improved by introducing an algorithm capable of correcting oblique images directly. This algorithm alters the pixels value, hence it is advised that image analysis is performed before image georectification. The drawback of this research is that the low-cost GPS device experienced bad checksum errors, which resulted in missing data. The Wide Area Augmented System (WAAS) correction could not be employed because the satellites could not be locked onto whilst flying. The best GPS data were obtained from the Garmin eTrex (15 m kinematic and 2 m static) instruments which have a highsensitivity receiver with good lock on capability. The limitation of this GPS device is the inability to effectively receive the P-Code wavelength, which is needed to gain the best accuracy when undertaking differential GPS processing. Pairing the carrier phase L1 with the pseudorange C/A-Code received, in order to determine the image coordinates by the differential technique, is still under investigation. To improve the position accuracy, it is recommended that a GPS base station should be established near the survey area, instead of using a permanent GPS base station established by the Ordnance Survey.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Tests of postural stability have provided some evidence of a link between deficits in gross motor skills and developmental dyslexia. The ordinal-level scales used previously, however, have limited measurement sensitivity, and no studies have investigated motor performance during walking in participants with dyslexia. The purpose of this study was to investigate if continuous-scaled measures of standing balance and gait could discriminate between groups of impaired and normal readers when investigators were blind to group membership during testing. Children with dyslexia (n=22) and controls (n=18), aged 10-12 years, performed walking tests at four different speeds (slow-preferred-fast-very fast) on an even and an uneven surface, and tests of unperturbed and perturbed body sway during standing. Body movements were registered by a triaxial accelerometer over the lower trunk, and measures of reaction time, body sway, walking speed, step length and cadence were calculated. Results were controlled for gender differences. Tests of standing balance with eyes closed did not discriminate between groups. All unperturbed standing tests with eyes open showed significant group differences (P<0.05) and classified correctly 70-77.5% of the subjects into their respective groups. Mean walking speed during very fast walking on both flat and uneven surface was ≥0.2 m/s (P≤0.01) faster for controls than for the group with dyslexia. This test classified 77.5% and 85% of the subjects correctly on flat and uneven surface, respectively Cadence at preferred or very fast speed did not differ statistically between groups, but revealed significant group differences when all subjects were compared at a normalised walking speed (P≤0.04). Very fast walking speed as well as cadence at a normalised speed discriminated better between groups when subjects were walking on an uneven surface compared to a flat floor. Continuous-scaled walking tests performed in field settings may be suitable for motor skill assessment as a component of a screening tool for developmental dyslexia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Through a lumped parameter modelling approach, a dynamical model, which can reproduce the motion of the muscles of a human body standing in different postures during Whole Body Vibrations (WBVs) treatment, has been developed. The key parameters, associated to the dynamics of the motion of the muscles of the lower limbs, have been identified starting from accelerometer measurements. The developed model can be usefully applied to the optimization of WBVs treatments which can effectively enhance muscle activation. © 2013 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to highlight the relationship between muscle motion, generated by whole body vibration, and the correspondent electromyographic (EMG) activity and to suggest a new method to customize the stimulation frequency. Simultaneous recordings of EMG and tri-axial accelerations of quadriceps rectus femoris from fifteen subjects undergoing vibration treatments were collected. Vibrations were delivered via a sinusoidal oscillating platform at different frequencies (10-45 Hz). Muscle motion was estimated by processing the accelerometer data. Large EMG motion artifacts were removed using sharp notch filters centred at the vibration frequency and its superior harmonics. EMG-RMS values were computed and analyzed before and after artifact suppression to assess muscular activity. Muscles acceleration amplitude increased with frequency. Muscle displacements revealed a mechanical resonant-like behaviour of the muscle. Resonance frequencies and dumping factors depended on subject. Moreover, RMS of artifact-free EMG was found well correlated (R 2 = 0.82) to the actual muscle displacement, while the maximum of the EMG response was found related to the mechanical resonance frequency of muscle. Results showed that maximum muscular activity was found in correspondence to the mechanical resonance of the muscle itself. Assuming the hypothesis that muscle activation is proportional to muscle displacement, treatment optimization (i.e. to choose the best stimulation frequency) could be obtained by simply monitoring local acceleration (resonance), leading to a more effective muscle stimulation. Motion artifact produced an overestimation of muscle activity, therefore its removal was essential. © 2009 IPEM.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electromyography readings (EMGs) from quadriceps of fifteen subjects were recorded during whole body vibration treatment at different frequencies (10-50 Hz). Additional electrodes were placed on the patella to monitor the occurrence of motion artifact, triaxial accelerometers were placed onto quadriceps to monitor motion. Signal spectra revealed sharp peaks corresponding to vibration frequency and its harmonics, in accordance with the accelerometer data. EMG total power was compared to that associated with vibration harmonics narrow bands, before and during vibration. On average, vibration associated power resulted in only 3% (±0.9%) of the total power prior to vibration and 29% (±13.4%) during vibration. Often, studies employ surface EMG to quantitatively evaluate vibration evoked muscular activity and to set stimulation frequency. However, previous research has not accounted for motion artifacts. The data presented in this study emphasize the need for the removal of motion artifacts, as they consistently affect RMS estimation, which is often used as a concise muscle activity index during vibrations. Such artifacts, rather unpredictable in amplitude, might be the cause of large inter-study differences and must be eliminated before analysis. Motion artifact filtering will contribute to thorough and precise interpretation of neuromuscular response to vibration treatment. © 2008 Elsevier Ltd. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this study is to highlight the relation between muscle motion and electromyographyc activity during whole body vibration. This treatment is accounted for eliciting a reflex muscle activity in response to vibratory stimulation. Simultaneous recordings from quadriceps Rectus Femoris EMG and 3D muscle accelerations on fifteen subjects undergoing vibration treatments were collected. In our study vibrations were delivered via a sinusoidal oscillating platform at different frequencies (10-45 Hz), with a constant amplitude. Muscle motion was estimated by processing accelerometer data. Displacements revealed a mechanical resonant-like behaviour of the muscle; resonance frequencies and dumping factors depended on subject. Large EMG motion artifacts were removed using sharp notch filters centred at the vibration frequency and its superior harmonics. RMS values of artifact-free EMG were found correlated to the actual muscle displacement. The results were in accordance to the hypothesis of a proprioceptive response during vibration treatment. Nevertheless, motion artifacts produced an overestimation of muscle activity, therefore its removal was essential. © 2009 Springer Berlin Heidelberg.