900 resultados para vein diameter


Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS The aim of the study was to examine whether differences in average diameter of low-density lipoprotein (LDL) particles were associated with total and cardiovascular mortality. METHODS AND RESULTS We studied 1643 subjects referred to coronary angiography, who did not receive lipid-lowering drugs. During a median follow-up of 9.9 years, 398 patients died, of these 246 from cardiovascular causes. We calculated average particle diameters of LDL from the composition of LDL obtained by β-quantification. When LDL with intermediate average diameters (16.5-16.8 nm) were used as reference category, the hazard ratios (HRs) adjusted for cardiovascular risk factors for death from any cause were 1.71 (95% CI: 1.31-2.25) and 1.24 (95% CI: 0.95-1.63) in patients with large (>16.8 nm) or small LDL (<16.5 nm), respectively. Adjusted HRs for death from cardiovascular causes were 1.89 (95% CI: 1.32-2.70) and 1.54 (95% CI: 1.06-2.12) in patients with large or small LDL, respectively. Patients with large LDL had higher concentrations of the inflammatory markers interleukin (IL)-6 and C-reactive protein than patients with small or intermediate LDL. Equilibrium density gradient ultracentrifugation revealed characteristic and distinct profiles of LDL particles in persons with large (approximately even distribution of intermediate-density lipoproteins and LDL-1 through LDL-6) intermediate (peak concentration at LDL-4) or small (peak concentration at LDL-6) average LDL particle diameters. CONCLUSIONS Calculated LDL particle diameters identify patients with different profiles of LDL subfractions. Both large and small LDL diameters are independently associated with increased risk mortality of all causes and, more so, due to cardiovascular causes compared with LDL of intermediate size.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This manuscript deals with the adaptation of quartz-microfabrics to changing physical deformation conditions, and discusses their preservation potential during subsequent retrograde deformation. Using microstructural analysis, a sequence of recrystallization processes in quartz, ranging from Grain-Boundary Migration Recrystallization (GBM) over Subgrain-Rotation Recrystallization (SGR) to Bulging Nucleation (BLG) is detected for the Simplon fault zone (SFZ) from the low strain rim towards the internal high strain part of the large-scale shear zone. Based on: (i) the retrograde cooling path; (ii) estimates of deformation temperatures; and (iii) spatial variation of dynamic recrystallization processes and different microstructural characteristics, continuous strain localization with decreasing temperature is inferred. In contrast to the recrystallization microstructures, crystallographic preferred orientations (CPO) have a longer memory. CPO patterns indicative of prism and rhomb glide systems in mylonitic quartz veins, overprinted at low temperatures (�400 �C), suggest inheritance of a high-temperature deformation. In this way, microstructural, textural and geochemical analyses provide information for several million years of the deformation history. The reasons for such incomplete resetting of the rock texture is that strain localization is caused by change in effective viscosity contrasts related to temporal large- and small-scale temperature changes during the evolution of such a long-lived shear zone. The spatially resolved, quantitative investigation of quartz microfabrics and associated recrystallization processes therefore provide great potential for an improved understanding of the geodynamics of large-scale shear zones.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES The aim of the study was to investigate 4-year outcomes and predictors of repeat revascularization in patients treated with the Resolute zotarolimus-eluting stent (R-ZES) (Medtronic, Minneapolis, Minnesota) and XIENCE V everolimus-eluting stent (EES) (Abbott Vascular, Abbott Park, Illinois) in the RESOLUTE (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention) All-Comers trial. BACKGROUND Data on long-term outcomes of new-generation drug-eluting stents are limited, and predictors of repeat revascularization due to restenosis and/or progression of disease are largely unknown. METHODS Patients were randomly assigned to treatment with the R-ZES (n = 1,140) or the EES (n = 1,152). We assessed pre-specified safety and efficacy outcomes at 4 years including target lesion failure and stent thrombosis. Predictors of revascularization at 4 years were identified by Cox regression analysis. RESULTS At 4 years, the rates of target lesion failure (15.2% vs. 14.6%, p = 0.68), cardiac death (5.4% vs. 4.7%, p = 0.44), and target vessel myocardial infarction (5.3% vs. 5.4%, p = 1.00), clinically-indicated target lesion revascularization (TLR) (7.0% vs. 6.5%, p = 0.62), and definite/probable stent thrombosis (2.3% vs. 1.6%, p = 0.23) were similar with the R-ZES and EES. Independent predictors of TLR were age, insulin-treated diabetes, SYNTAX (Synergy between PCI with Taxus and Cardiac Surgery) score, treatment of saphenous vein grafts, ostial lesions, and in-stent restenosis. Independent predictors of any revascularization were age, diabetes, previous percutaneous coronary intervention, absence of ST-segment elevation myocardial infarction, smaller reference vessel diameter, SYNTAX score, and treatment of left anterior descending, right coronary artery, saphenous vein grafts, ostial lesions, or in-stent restenosis. CONCLUSIONS R-ZES and EES demonstrated similar safety and efficacy throughout 4 years. TLR represented less than one-half of all repeat revascularization procedures. Patient- and lesion-related factors predicting the risk of TLR and any revascularization showed considerable overlap. (A Randomized Comparison of a Zotarolimus-Eluting Stent With an Everolimus-Eluting Stent for Percutaneous Coronary Intervention [RESOLUTE-AC]; NCT00617084).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE To prospectively evaluate the psychometric properties of the Venous Insufficiency Epidemiological and Economic Study (VEINES-QOL/Sym) questionnaire, an instrument to measure disease-specific quality of life and symptoms in elderly patients with deep vein thrombosis (DVT), and to validate a German version of the questionnaire. METHODS In a prospective multicenter cohort study of patients aged ≥ 65 years with acute venous thromboembolism, we used standard psychometric tests and criteria to evaluate the reliability, validity, and responsiveness of the VEINES-QOL/Sym in patients with acute symptomatic DVT. We also performed an exploratory factor analysis. RESULTS Overall, 352 French- and German-speaking patients were enrolled (response rate of 87 %). Both language versions of the VEINES-QOL/Sym showed good acceptability (missing data, floor and ceiling effects), reliability (internal consistency, item-total and inter-item correlations), validity (convergent, discriminant, known-groups differences), and responsiveness to clinical change over time in elderly patients with DVT. The exploratory factor analysis of the VEINES-QOL/Sym suggested three underlying dimensions: limitations in daily activities, DVT-related symptoms, and psychological impact. CONCLUSIONS The VEINES-QOL/Sym questionnaire is a practical, reliable, valid, and responsive instrument to measure quality of life and symptoms in elderly patients with DVT and can be used with confidence in prospective studies to measure outcomes in such patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND -This study aimed to determine five-year efficacy of catheter ablation for persistent atrial fibrillation (PsAF) using AF termination as a procedural endpoint. METHODS AND RESULTS -150 patients (57±10 years) underwent PsAF ablation using a stepwise ablation approach (pulmonary vein isolation, electrogram-guided and linear ablation) with the desired procedural endpoint being AF termination. Repeat ablation was performed for recurrent AF or atrial tachycardia (AT). AF was terminated by ablation in 120 patients (80%). Arrhythmia-free survival rates after a single procedure were 35.3±3.9%, 28.0±3.7%, and 16.8±3.2% at 1, 2, and 5 years, respectively. Arrhythmia-free survival rates after the last procedure (mean 2.1±1.0 procedures) were 89.7±2.5%, 79.8±3.4%, and 62.9±4.5%, at 1, 2, and 5 years, respectively. During a median follow-up of 58 (IQR 43-73) months following the last ablation procedure, 97 of 150 (64.7%) patients remained in sinus rhythm without antiarrhythmic drugs (AADs). Another 14 (9.3%) patients maintained sinus rhythm after re-initiation of AADs, and an additional 15 (10.0%) patients regressed to paroxysmal recurrences only. Failure to terminate AF during the index procedure (HR 3.831; 95%CI: 2.070-7.143; p<0.001), left atrial diameter ≥50mm (HR 2.083; 95%CI: 1.078-4.016; p=0.03), continuous AF duration ≥18 months (HR 1.984; 95%CI: 1.024-3.846; p<0.04) and structural heart disease (HR 1.874; 95% CI: 1.037-3.388; p=0.04) predicted arrhythmia recurrence. CONCLUSIONS -In patients with PsAF, an ablation strategy aiming at AF termination is associated with freedom from arrhythmia recurrence in the majority of patients over a 5-year follow up period.Procedural AF non-termination and specific baseline factors predict long-term outcome after ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND For patients with acute iliofemoral deep vein thrombosis, it remains unclear whether the addition of intravascular high-frequency, low-power ultrasound energy facilitates the resolution of thrombosis during catheter-directed thrombolysis. METHODS AND RESULTS In a controlled clinical trial, 48 patients (mean age 50±21 years, 52% women) with acute iliofemoral deep vein thrombosis were randomized to receive ultrasound-assisted catheter-directed thrombolysis (N=24) or conventional catheter-directed thrombolysis (N=24). Thrombolysis regimen (20 mg r-tPA over 15 hours) was identical in all patients. The primary efficacy end point was the percentage of thrombus load reduction from baseline to 15 hours according to the length-adjusted thrombus score, obtained from standardized venograms and evaluated by a core laboratory blinded to group assignment. The percentage of thrombus load reduction was 55%±27% in the ultrasound-assisted catheter-directed thrombolysis group and 54%±27% in the conventional catheter-directed thrombolysis group (P=0.91). Adjunctive angioplasty and stenting was performed in 19 (80%) patients and in 20 (83%) patients, respectively (P>0.99). Treatment-related complications occurred in 3 (12%) and 2 (8%) patients, respectively (P>0.99). At 3-month follow-up, primary venous patency was 100% in the ultrasound-assisted catheter-directed thrombolysis group and 96% in the conventional catheter-directed thrombolysis group (P=0.33), and there was no difference in the severity of the post-thrombotic syndrome (mean Villalta score: 3.0±3.9 [range 0-15] versus 1.9±1.9 [range 0-7]; P=0.21), respectively. CONCLUSIONS In this randomized controlled clinical trial of patients with acute iliofemoral deep vein thrombosis treated with a fixed-dose catheter thrombolysis regimen, the addition of intravascular ultrasound did not facilitate thrombus resolution. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT01482273.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES/HYPOTHESIS Study of the clinical evolution of a primary ear, nose, and throat infection complicated by septic thrombophlebitis of the internal jugular vein. STUDY DESIGN Retrospective case-control study. PATIENTS AND METHODS From 1998 to 2010, 23 patients at our institution were diagnosed with a septic thrombosis of the internal jugular vein. Diagnostics included microbiologic analysis and imaging such as computed tomography, magnetic resonance imaging, and ultrasound. Therapy included broad-spectrum antibiotics, surgery of the primary infectious lesion, and postoperative anticoagulation. The patients were retrospectively analyzed. RESULTS The primary infection sites were found in the middle ear (11), oropharynx (8), sinus (3), and oral cavity (1). Fourteen patients needed intensive care unit treatment for a mean duration of 6 days. Seven patients were intubated, and two developed severe acute respiratory distress syndrome. An oropharynx primary infection site was most prone to a prolonged clinical evolution. Anticoagulation therapy was given in 90% of patients. All 23 patients survived the disseminated infection without consecutive systemic morbidity. CONCLUSION In the pre-antibiotic time, septic internal jugular vein thrombophlebitis was a highly fatal condition with a mortality rate of 90%. Modern imaging techniques allow early and often incidental diagnosis of this clinically hidden complication. Anticoagulation, intensive antibiotic therapy assisted by surgery of the primary infection site, and intensive supportive care can reach remission rates of 100%. LEVEL OF EVIDENCE 3b. Laryngoscope, 2014.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Portal vein embolization (PVE) may be performed before hemihepatectomy to increase the volume of future liver remnant (FLR) and to reduce the risk of postoperative liver insufficiency. We report the case of a 71-year-old patient with hilar cholangiocarcinoma undergoing PVE with access from the right portal vein using a mixture of n-butyl-2-cyanoacrylate and ethiodized oil. During the procedure, nontarget embolization of the left portal vein occurred. An aspiration maneuver of the polymerized plug failed; however, the embolus obstructing portal venous flow in the FLR was successfully relocated into the right portal vein while carefully bypassing the plug with a balloon catheter, inflating the balloon, and pulling the plug into the main right portal vein.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Retinal vein occlusion is a leading cause of visual impairment. Experimental models of this condition based on laser photocoagulation of retinal veins have been described and extensively exploited in mammals and larger rodents such as the rat. However, few reports exist on the use of this paradigm in the mouse. The objective of this study was to investigate a model of branch and central retinal vein occlusion in the mouse and characterize in vivo longitudinal retinal morphology alterations using spectral domain optical coherence tomography. Retinal veins were experimentally occluded using laser photocoagulation after intravenous application of Rose Bengal, a photo-activator dye enhancing thrombus formation. Depending on the number of veins occluded, variable amounts of capillary dropout were seen on fluorescein angiography. Vascular endothelial growth factor levels were markedly elevated early and peaked at day one. Retinal thickness measurements with spectral domain optical coherence tomography showed significant swelling (p<0.001) compared to baseline, followed by gradual thinning plateauing two weeks after the experimental intervention (p<0.001). Histological findings at day seven correlated with spectral domain optical coherence tomography imaging. The inner layers were predominantly affected by degeneration with the outer nuclear layer and the photoreceptor outer segments largely preserved. The application of this retinal vein occlusion model in the mouse carries several advantages over its use in other larger species, such as access to a vast range of genetically modified animals. Retinal changes after experimental retinal vein occlusion in this mouse model can be non-invasively quantified by spectral domain optical coherence tomography, and may be used to monitor effects of potential therapeutic interventions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE Currently one of the most widely used models for the development of endovascular techniques and coiling devices for treatment of aneurysm is the elastase-induced aneurysm model in the rabbit carotid artery. Microsurgical techniques for creating an aneurysm with a venous pouch have also been established, although both techniques usually result in aneurysms less than 1 cm in diameter. We investigated whether an increase in blood flow toward the neck would produce larger aneurysms in a microsurgical venous pouch model. MATERIALS AND METHODS Microsurgical operations were performed on 11 New Zealand white rabbits. Both carotid arteries and the right jugular vein were dissected, and the right carotid artery was temporarily clipped followed by an arteriotomy. The left carotid artery was also clipped proximally, ligated distally, and sutured onto the proximal half of the arteriotomy in the right carotid artery. The venous graft was sutured onto the distal half of the arteriotomy. Digital subtraction angiography was also performed. RESULTS Angiography showed patent anastomosed vessels and aneurysms in the seven surviving rabbits. Mean aneurysm measurements among surviving rabbits with patent vessels were: 13.9 mm length, 9.3 mm width, and neck diameter 4.7 mm. The resulting mean aspect ratio was 3.35 and the mean bottleneck ratio was 3.05. CONCLUSION A large venous graft and increased blood flow toward the base of the aneurysm seem to be key factors in the creation of large venous pouch aneurysms. These large aneurysms allow testing of endovascular devices designed for large and giant aneurysms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Long-term success rates using ablation for persistent atrial fibrillation (AF) are disappointing and usually do not exceed 60%. OBJECTIVES This study sought to compare arrhythmia-free survival between pulmonary vein isolation (PVI) and a stepwise approach (full defrag) consisting of PVI, ablation of complex fractionated electrograms, and additional linear ablation lines in the setting of atrial tachycardias (AT) in patients with persistent AF after PVI. METHODS From November 2010 to February 2013, 205 patients (151 men; 61.7 ± 10.2 years of age) underwent de novo ablation for persistent AF. Subsequently, patients were prospectively randomized to either PVI alone (n = 78) or full defrag (n = 75), with 52 patients not randomized due to AF termination with the original PVI. The primary endpoint was recurrence of any AT after a blanking period of 3 months. RESULTS During the entire study, 241 ablations were performed (mean: 1.59 in the PVI-alone group, 1.55 in the full-defrag group). With the stepwise approach, termination of AF occurred in 45 (60%) patients. However, arrhythmia-free survival did not differ whether patients underwent single or multiple procedures (p = 0.468). Procedure duration, fluoroscopy time, and radiofrequency duration were significantly longer in the full-defrag group (all p < 0.001). CONCLUSIONS A stepwise approach aimed at AF termination does not seem to provide additional benefit over PVI alone in patients with persistent AF, but it is associated with significantly longer procedural and fluoroscopic duration as well as radiofrequency application time. (The Randomized Catheter Ablation of Persist End Atrial Fibrillation Study [CHASE-AF]; NCT01580124).