1000 resultados para ultrassonografia quantitativa


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Study the semi-quantitative and quantitative technique in the diagnosis of catheter-related infections in newborns and to determine oxacillin resistance in Staphylococcus isolated. It was analyzed 353 catheter tips from 273 newborns in the Neonatal Unit of Hospital FMB. To confirm the diagnosis of infection, were analyzed the clinical data of newborns, the presence of at least one positive blood culture and growth of ≥ 1000 CFU/mL on quantitative culture and/or ³15 UFC on semiquantitative culture, with the same microorganism isolation (species and drug sensitivity) in blood culture and no other focus of infection except the catheter. The disk diffusion technique was used to check similarity of strains and resistance to oxacillin. Of the 353 tips analyzed, 39 were included in this study as the inclusion criteria. The semiquantitative culture was positive in 26 (66.7%) catheters and quantitative culture was positive in 24 (61.5%). Of 273 patients, 19 (6.9%) had a diagnosis of catheter-related bloodstream Infection (CR-BSI). Of the 19 episodes of CR-BSI, S. epidermidis was the predominant etiological agent (84.2%). The resistance to the antibiotic methicillin was found in 14 (73.7%) strains of Staphylococcus. The semiquantitative method was more sensitive (79%) compared with the quantitative method (63%). The use of antibiotics may have influenced the sensitivity of the quantitative method as the microorganisms present in the lumen are exposed to higher concentrations of antibiotics administered via the catheter

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The equine locomotors system alterations are very frequent and corresponds a large portion of cases in equine medicine. The most equine veterinarian’s challenge is to do a precise diagnosis of lameness cause to perform a specific and proper treatment as early as possible. The navicular syndrome is considered responsible for one third of lameness causes and, although much studied, its etiology is still not fully understood. The most varied methods of diagnosis, such as x-ray, magnetic resonance, bursography, scintigraphy, computed tomography and ultrasound, have been used to assess podotrochlear apparatus situation in order to diagnose this syndrome. Among them transcuneal ultrasound can be used to observe some important structures such as the flexor surface of distal sesamoid bone, distal deep digital flexor tendon, distal sesamoid ligament entheses odd and the distal phalanx. The aim of this present paper is provide a brief review on the use and the technique of ultrasonography on third phalanx transcuneal region evaluation and its interpretation on navicular syndrome diagnosis in horses

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As abelhas da espécie Apis mellifera são conhecidas por sua organização social, comportamento devotado e aparente complexidade comportamental, sendo também consideradas excelentes sistemas-modelo para estudos de comunicação, aprendizado e formação de memória. Uma vez que o comportamento social dos insetos é resultante de interações complexas em diferentes níveis de organização biológica, torna-se importante estudar os peptídeos envolvidos nesse processo, já que estes são indispensáveis em muitos processos fisiológicos, funcionando como neurotransmissores, hormônios, toxinas, antibióticos, defensinas, neuromoduladores e neurohormônios. Desta forma, o objetivo do presente trabalho foi padronizar uma metodologia analítica visando à determinação do perfil peptídico do cérebro de abelhas da espécie Apis mellifera utilizando como ferramentas a espectrometria de massas e a cromatografia líquida. Foram coletadas operárias de Apis mellifera com 20 dias de idade, cujos cérebros foram dissecados e devidamente processados visando a posterior separação e identificação dos peptídeos. Foram testadas duas estratégias distintas para a separação e identificação dos peptídeos, denominadas on-line e off-line. Ambas baseavam-se na utilização de um sistema de cromatografia líquida sob fase reversa e um espectrômetro de massas do tipo electrospray/Ion Trap-Time of Flight, mas na primeira essas ferramentas estavam acopladas, enquanto na segunda os dois processos foram realizados separadamente. Tais procedimentos permitiram identificar 19 peptídeos pertencentes às principais famílias de neuropeptídeos de cérebros de abelhas já descritos na literatura, entre elas as Alatostatina, Apidaecina, Corazonina e Taquicininas. Os resultados obtidos indicam que a estratégia off-line foi melhor em comparação à estratégia on-line, devido à possibilidade de se trabalhar com cada fração obtida separadamente para as...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Companies, in general, operate due to the work of its subsystems and this is possible thanks to operational planning that tries to promote the best way to integrate them without giving up the mission, vision and values of the company. The main purpose of a business is to serve customers, but to be successful must take into account other factors such as survival, profitability, growth and operational standpoint to use their resources effectively. The use of tools to support the process of analysis of management decision-making is gaining importance in the context of competitiveness in the world market. The objective of this paper is to present a simulation of the process of forecasting demand to obtain optimal results for a steel company, compare the actual results with order entry and assess the magnitude of the error

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper presents the radiometric parameters determined by the medical physicist during routine radiotherapy planning service in cases of breast cancer . The contours of the breast volume in patients undergoing radiation breast tumors at the Hospital das Clinicas, Faculty of Medicine , UNESP, Botucatu ( HCFMB ) during the year 2012 were analyzed . In order to analyze the influence of physical and radiometric parameters for the determination of the dose distribution of irradiated breast volume , four measurements of isodose curves were prepared in four different heights breast , and compared with the isodose curves plotted computationally . In the routine of planning , the medical physicist must determine the isodose curve that gives the best dose distribution homogeneity in the irradiated volume . The choice of the treatment plan can be done by dedicated computer systems , which require significantly costly investments available services having better financial support . In the Service of Medical Physics , Department of Radiotherapy , HC FMB , we use a two-dimensional software for determination of isodose curves , however , this software is out of date and frequently becomes inoperable due to the lack of maintenance and it is a closed system without feasibility of interference from computer professionals . This fact requires manual preparation of isodose curves , which are subject to uncertainties due to the subjectivity in the clinical interpretation of medical radiation oncologist and medical physicist responsible for planning , plus dispendiar significant calculation time . The choice of the optimal isodose curve depends on the energy of the radiation beam , the geometry and dimensions of the irradiated area . The contours of the breast studied in this work evaluations showed that , for a given energy input , such as the energy of 1.25 MeV of gamma radiation Unit Telecobaltoterapia , the determination of the percentage depth dose ( PDP ) ...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Medicina Veterinária - FCAV

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

O tratamento clareador se destaca por ser uma técnica conservadora, que pode proporcionar elevação da autoestima e melhorar o convívio social das pessoas. No entanto, pacientes expostos a essa terapia experimentam diferentes níveis de ocorrência e de intensidade de sensibilidade dentária. Essa sintomatologia é preocupante, pois tem sido apontada como o reflexo de uma eventual resposta pulpar frente ao tratamento realizado. Por outro lado, a presença de dor é desestimulante aos pacientes, prejudicando a evolução do tratamento e reduzindo o sentimento de satisfação. Apesar dessa importância, a maior parte dos estudos de sensibilidade dentária ainda emprega métodos subjetivos, dificultando a reprodutibilidade e interpretação dos resultados. Objetivo: nesse sentido, o presente artigo objetiva analisar a resposta neurossensorial proporcionada pela aplicação de estímulos térmicos gerados pelo equipamento TSA II (Medoc TSA II Neurosensory Analyzer, Israel), em um paciente submetido ao tratamento clareador, seguido pelo uso ou não uso de um dessensibilizante. Métodos: as análises foram realizadas antes do clareamento (AC), depois do clareamento (DC) e depois da aplicação ou não do dessensibilizante (DD) em cada hemiarcada estudada. Os dados foram submetidos ao teste t de Student, com nível de significância de 5%. Resultados: observou-se que o clareamento dentário alterou o limiar de sensação ao frio, provocando aumento da sensibilidade dentária, e que o uso do dessensibilizante foi efetivo. Conclusão: o uso de testes sensoriais quantitativos mostrou-se promissor para o estudo da sensibilidade dentária, podendo colaborar no estabelecimento de terapias seguras e confortáveis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A cinomose é uma doença de desafio diagnóstico, especialmente quando não há histórico de vacinação. O objetivo deste estudo foi detectar e quantificar partículas virais de cinomose em diferentes fluidos e tecidos biológicos de um cão, determinando o melhor tecido para diagnóstico viral ante mortem na fase de viremia. Atendeu-se um cão adulto com manifestações clínicas inespecíficas e corpúsculos de Sinegaglia Lentz em linfócitos. Amostras post mortem foram submetidas a PCR em tempo real (qPCR), que demonstrou RNA viral em concentrações de (x105) em líquor (1.216), bexiga (1.009), cérebro (605), sangue (572), cerebelo (523), rins (373), fígado (257), pulmões (191), estômago (154), terceira pálpebra (70) e urina (2,1). A técnica de qPCR permitiu confirmar a infecção pelo vírus, descartando vacinação recente. A amostra de líquor mostrou-se representativa para diagnóstico molecular de fase aguda de cinomose no animal estudado.