1000 resultados para tratamento de efluentes


Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study used a multi-analytical approach based on traditional microbiological methods for cultivation and isolation of heterotrophic bacteria in the laboratory associated with the molecular identification of the isolates and physicochemical analysis of environmental samples. The model chosen for data integration was supported by knowledge from computational neuroscience, and composed by three modules: (i) microbiological parameters, contemplating taxonomic data obtained from the partial sequencing of the 16S rRNA gene from 80 colonies of heterotrophic bacteria isolated by plating method in PCA media. For bacterial colonies isolation were used water samples from Atibaia and Jaguarí rivers collected at the site of water captation for use in effluent treatment, upstream from the entrance of treated effluent from the Paulínia refinery (REPLAN/Petrobras) located in the Paulínia-SP municipality, from the output of the biological treatment plant with stabilization pond and from the raw refinery wastewater; (ii) chemical parameters, ending measures of dissolved oxygen (DO), chemical oxygen demand (COD), biochemical oxygen demand (BOD), chloride, acidity CaCO3, alkalinity, ammonia, nitrite, nitrate, dissolved ions, sulfides, oils and greases; and (iii) physical parameters, comprising the pH determination, conductivity, temperature, transparency, settleable solids, suspended and soluble solids, volatile material, remaining fixing material (RFM), apparent color and turbidity. The results revealed interesting theoretical relationships involving two families of bacteria (Carnobacteriaceae and Aeromonadaceae). Carnobacteriaceae revealed positive theoretical relationships with COD, BOD, nitrate, chloride, temperature, conductivity and apparent color and negative theoretical relationships with the OD. Positive theoretical relationships were shown between Aeromonadaceae and OD and nitrate, while this bacterial family showed negative theoretical...

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Este trabalho teve como objetivo avaliar o tratamento de água bruta proveniente de um reservatório de água, utilizando instalação piloto de dupla filtração (DF), composta por filtro ascendente de pedregulho (FAP) e filtro rápido descendente de areia (FRD), seguida de uma unidade de pós-tratamento com carvão ativado granular (CAG). Adicionalmente, foi verificado o efeito da pré e interoxidação (entre o FAP e o FRD) na eficiência global do tratamento e na formação de subprodutos orgânicos halogenados (SOH). Em função dos resultados obtidos, foi observado que a pré-oxidação melhorou a qualidade do efluente do FAP e a interoxidação favoreceu que resultassem valores menores de turbidez e cor no efluente do FRD. O processo de tratamento por adsorção em carvão ativado granular, utilizado como pós-tratamento, mostrou-se eficiente para assegurar a qualidade dos efluentes finais nos ensaios realizados, especialmente, em relação à remoção de matéria orgânica, cianobactérias e cor. As concentrações máximas de SOH encontrados nos efluentes do FRD e do FCAG não ultrapassaram os valores limites da Portaria nº 2.914/2011 do Ministério da Saúde.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The principal effluent in the oil industry is the produced water, which is commonly associated to the produced oil. It presents a pronounced volume of production and it can be reflected on the environment and society, if its discharge is unappropriated. Therefore, it is indispensable a valuable careful to establish and maintain its management. The traditional treatment of produced water, usualy includes both tecniques, flocculation and flotation. At flocculation processes, there are traditional floculant agents that aren’t well specified by tecnichal information tables and still expensive. As for the flotation process, it’s the step in which is possible to separate the suspended particles in the effluent. The dissolved air flotation (DAF) is a technique that has been consolidating economically and environmentally, presenting great reliability when compared with other processes. The DAF is presented as a process widely used in various fields of water and wastewater treatment around the globe. In this regard, this study was aimed to evaluate the potential of an alternative natural flocculant agent based on Moringa oleifera to reduce the amount of oil and grease (TOG) in produced water from the oil industry by the method of flocculation/DAF. the natural flocculant agent was evaluated by its efficacy, as well as its efficiency when compared with two commercial flocculant agents normally used by the petroleum industry. The experiments were conducted following an experimental design and the overall efficiencies for all flocculants were treated through statistical calculation based on the use of STATISTICA software version 10.0. Therefore, contour surfaces were obtained from the experimental design and were interpreted in terms of the response variable removal efficiency TOG (total oil and greases). The plan still allowed to obtain mathematical models for calculating the response variable in the studied conditions. Commercial flocculants showed similar behavior, with an average overall efficiency of 90% for oil removal, however it is the economical analysis the decisive factor to choose one of these flocculant agents to the process. The natural alternative flocculant agent based on Moringa oleifera showed lower separation efficiency than those of commercials one (average 70%), on the other hand this flocculant causes less environmental impacts and it´s less expensive

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A major and growing problems faced by modern society is the high production of waste and related effects they produce, such as environmental degradation and pollution of various ecosystems, with direct effects on quality of life. The thermal treatment technologies have been widely used in the treatment of these wastes and thermal plasma is gaining importance in processing blanketing. This work is focused on developing an optimized system of supervision and control applied to a processing plant and petrochemical waste effluents using thermal plasma. The system is basically composed of a inductive plasma torch reactors washing system / exhaust gases and RF power used to generate plasma. The process of supervision and control of the plant is of paramount importance in the development of the ultimate goal. For this reason, various subsidies were created in the search for greater efficiency in the process, generating events, graphics / distribution and storage of data for each subsystem of the plant, process execution, control and 3D visualization of each subsystem of the plant between others. A communication platform between the virtual 3D plant architecture and a real control structure (hardware) was created. The goal is to use the concepts of mixed reality and develop strategies for different types of controls that allow manipulating 3D plant without restrictions and schedules, optimize the actual process. Studies have shown that one of the best ways to implement the control of generation inductively coupled plasma techniques is to use intelligent control, both for their efficiency in the results is low for its implementation, without requiring a specific model. The control strategy using Fuzzy Logic (Fuzzy-PI) was developed and implemented, and the results showed satisfactory condition on response time and viability

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Heavy metals are present in industrial waste. These metals can generate a large environmental impact contaminating water, soil and plants. The chemical action of heavy metals has attracted environmental interest. In this context, this study aimed to test t he performance of electrochemical technologies for removing and quantifying heavy metals. First ly , the electroanalytical technique of stripping voltammetry with glassy carbon electrode (GC) was standardized in order to use this method for the quantificatio n of metals during their removal by electrocoagulation process (EC). A nalytical curves were evaluated to obtain reliability of the determin ation and quantification of Cd 2+ and Pb 2+ separately or in a mixture. Meanwhile , EC process was developed using an el ectrochemical cell in a continuous flow (EFC) for removing Pb 2+ and Cd 2+ . The se experiments were performed using Al parallel plates with 10 cm of diameter (  63.5 cm 2 ) . The optimization of conditions for removing Pb 2+ and Cd 2+ , dissolved in 2 L of solution at 151 L h - 1 , were studied by applying different values of current for 30 min. Cd 2+ and Pb 2+ concentrations were monitored during electrolysis using stripping voltammetry. The results showed that the removal of Pb 2 + was effective when the EC pro cess is used, obtaining removals of 98% in 30 min. This behavior is dependent on the applied current, which implies an increase in power consumption. From the results also verified that the stripping voltammetry technique is quite reliable deter mining Pb 2+ concentration , when compared with the measurements obtained by atomic absorption method (AA). In view of this, t he second objective of this study was to evaluate the removal of Cd 2+ and Pb 2+ (mixture solution) by EC . Removal efficiency increasing current was confirmed when 93% and 100% of Cd 2+ and Pb 2+ was removed after 30 min . The increase in the current promotes the oxidation of sacrificial electrodes, and consequently increased amount of coagulant, which influences the removal of heavy metals in solution. Adsortive voltammetry is a fast, reliable, economical and simple way to determine Cd 2+ and Pb 2+ during their removal. I t is more economical than those normally used, which require the use of toxic and expensive reagents. Our results demonstrated the potential use of electroanalytical techniques to monitor the course of environmental interventions. Thus, the application of the two techniques associated can be a reliable way to monitor environmental impacts due to the pollution of aquatic ecosystems by heavy metals.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The water supply and treatment is considered as a great benefit considering that, if done efficiently, provides public health. However, considering the WTP (Water Treatment Plant) is an industry, with its inputs and waste generation, they must be constantly evaluated and monitored to verify the best and most appropriate way to process and dispose their waste, minimizing therefore the potential impacts to the environment. By volume, the most significant waste is the rapid filter backwash water. It is very common the disposal of this waste without treatment in water sources, which are used, for the most part, as a water supply source of a downstream population. This study evaluated quantitative and qualitative parameters in filter backwash water in three WTP - Itaitinga, Maranguape and Pacatuba, located in Ceará State, northeast of Brazil. It was found that the Maranguape WTP, in terms of treatment capacity, is the larger. The Itaitinga WTP is the one that consumes more water during filters washing. The Pacatuba WTP exhibited higher concentration of total suspended and settleable solids, COD and aluminum in the filters backwash water. It is noteworthy that the settleable solids and total suspended solids in all three WTP are above the effluent discharge standard recommended by Resolution 154/2002 of SEMACE (State Superintendent of Environment of Ceará). It was concluded that the filter backwash water from the study WTP exceeded the allowed values for legislation to be disposed directly into surface water bodies. It is suggested as an alternative to treat and recycle the filter backwashing water the construction of sludge settling ponds.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Textile industry has been a cause of environmental pollution, mainly due to the generation of large volumes of waste containing high organic loading and intense color. In this context, this study evaluated the electrochemical degradation of synthetic effluents from textile industry containing Methylene Blue (AM) dye, using Ti/IrO2-Ta2O5 and Ti/Pt anodes, by direct and indirect (active chlorine) electrooxidation. We evaluated the influence of applied current density (20, 40 and 60 mA/cm2 ), and the presence of different concentrations of electrolyte (NaCl and Na2SO4), as well as the neutral and alkaline pH media. The electrochemical treatment was conducted in a continuous flow reactor, in which the electrolysis time of the AM 100 ppm was 6 hours. The performance of electrochemical process was evaluated by UV-vis spectrophotometry, chemical oxygen demand (COD) and total organic carbon (TOC). The results showed that with increasing current density, it was possible to obtain 100 % of color removal at Ti/IrO2-Ta2O5 and Ti/Pt electrodes. Regarding the color removal efficiency, increasing the concentration of electrolyte promotes a higher percentage of removal using 0,02 M Na2SO4 and 0,017 M NaCl. Concerning to the aqueous medium, the best color removal results were obtained in alkaline medium using Ti/Pt. In terms of organic matter, 86 % was achieved in neutral pH medium for Ti/Pt; while a 30 % in an alkaline medium. To understand the electrochemical behavior due to the oxygen evolution reaction, polarization curves were registered, determining that the presence of NaCl in the solution favored the production of active chlorine species. The best results in energy consumption and cost were obtained by applying lower current density (20 mA/cm2 ) in 6 hours of electrolysis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This work was performing effluent degradation studies by electrochemical treatment. The electrochemical oxidation (EO) hydroquinone (H2Q) was carried out in acid medium, using PbO2 electrode by galvanostatic electrolysis, applying current densities of 10 and 30 mA/cm2 . The concentration of H2Q was monitored by differential pulse voltammetry (DPV). The experimental results showed that the galvanostatic electrolysis process performance significantly depends on the applied current density, achieving removal efficiencies of 100% and 80 % and 10 applying 30 mA/cm2 , respectively. Furthermore, the electroanalytical technique was effective in H2Q be used as a detection method. In order to test the efficiency of PbO2 electrode, the electrochemical treatment was conducted in an actual effluent, leachate from a landfill. The liquid waste leachate (600ml effluent) was treated in a batch electrochemical cell, with or without addition of NaCl by applying 7 mA/cm2 . The efficiency of EO was assessed against the removal of thermo-tolerant coliforms, total organic carbon (TOC), total phosphorus and metals (copper, cobalt, chromium, iron and nickel). These results showed that efficient removal of coliforms was obtained (100%), and was further decrease the concentration of heavy metals by the cathode processes. However, results were not satisfactory TOC, achieving low total removal of dissolved organic load. Because it is considered an effluent complex were developed other tests with this effluent to monitor a larger number of decontamination parameters (Turbidity, Total Solids, Color, Conductivity, Total Organic Carbon (TOC) and metals (barium, chromium, lithium, manganese and Zinc), comparing the efficiency of this type of electrochemical treatment (EO or electrocoagulation) using a flow cell. In this assay was compared to electro streaming. In the case of the OE, Ti/IrO2-TaO5 was used as the anode, however, the electrocoagulation process, aluminum electrodes were used; applying current densities of 10, 20 and 30 mA/cm2 in the presence and absence of NaCl as an electrolyte. The results showed that EO using Ti/IrO2–TaO5 was anode as efficient when Cl- was present in the effluent. In contrast, the electrocoagulation flow reduces the dissolved organic matter in the effluent, under certain experimental conditions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Despite the numerous advantages resulting from the use of membrane filters technology, intrinsic limitations fouling process become relevant to its applicability. The control of operating conditions is an important tool to mitigate fouling and achieve good levels of efficiency. In this sense, the objective of this study was to investigate the effect of transmembrane pressure and concentrate flow in the performance of ultrafiltration, applied to the post-treatment of domestic sewage. The process was evaluated and optimized by varying the pressure (0.5 and 1.5 bar) and the concentrate flow (300 and 600 L/h), using a 22 factorial design, in order to investigate the effects on the permeate flow and quality of effluents generated at each operating condition. We evaluated the following quality indicators for permeate: pH, electrical conductivity, total suspended solids, turbidity, calcium and Chemical Oxygen Demand (COD). In all tests, we observed marked reduction in the permeate flux at the early stages, followed by a slow decline that lasted until it reaches a relatively constant level, around 120 minutes of filtration. The increased pressure resulted in a higher initial permeate flux, but the decrease of the flow with time is greater for tests at higher pressure, indicating a more pronounced fouling process. On the other hand, increasing the concentrate flow resulted in a slower decline in permeate flux with the filtration time. Regarding the quality of permeate, the transmembrane pressure of 0,5 bar was the one that allowed better results, and was statistically confirmed through the two-way ANOVA test with repeated measures, significant effect of pressure on the turbidity of the permeate. The concentrate flow, in turn, showed no significant influence on any of the quality parameters. Thus, we conclude that, from an economic and environmental point of view, it is more interesting to operate ultrafiltration membrane system with a lower concentrate flow associated with a low transmembrane pressure, since under these conditions will produce less waste, and the permeate will present lower concentrations of the analyzed constituent, especially lower turbidity.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oil exploration is one of the most important industrial activities of modern society. Despite its derivatives present numerous applications in industrial processes, there are many undesirable by-products during this process, one of them is water separated from oil, called water production, it is constituted by pollutants difficult to degrade. In addition, the high volume of generated water makes its treatment a major problem for oil industries. Among the major contaminants of such effluents are phenol and its derivatives, substances of difficult natural degradation, which due their toxicity must be removed by a treatment process before its final disposal. In order to facilitate the removal of phenol in wastedwater from oil industry, it was developed an extraction system by ionic flocculation with surfactant. The ionic flocculation relies on the reaction of carboxylate surfactant and calcium íons, yielding in an insoluble surfactant that under stirring, aggregates forming floc capable of attracting the organic matter by adsorption. In this work was used base soap as ionic surfactant in the flocculation process and evaluated phenol removal efficiency in relation to the following parameters: surfactant concentration, phenol, calcium and electrolytes, stirring speed, contact time, temperature and pH. The flocculation of the surfactant occurred in the effluent (initial phenol concentration = 100 ppm) reaching 65% of phenol removal to concentrations of 1300 ppm and calcium of 1000 ppm, respectively, at T = 35 °C, pH = 9.7, stirring rate = 100 rpm and contact time of 5 minutes. The permanence of the flocs in an aqueous medium promotes desorption of the phenol from the flake surface to the solution, reaching 90% of desorption at a time of 150 minutes, and the study of desorption kinetics showed that Lagergren model of pseudo-first order was adequate to describe the phenol desorption. These results shows that the process may configure a new alternative of treatment in regard the removal of phenol of aqueous effluent of oil industry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Oil exploration is one of the most important industrial activities of modern society. Despite its derivatives present numerous applications in industrial processes, there are many undesirable by-products during this process, one of them is water separated from oil, called water production, it is constituted by pollutants difficult to degrade. In addition, the high volume of generated water makes its treatment a major problem for oil industries. Among the major contaminants of such effluents are phenol and its derivatives, substances of difficult natural degradation, which due their toxicity must be removed by a treatment process before its final disposal. In order to facilitate the removal of phenol in wastedwater from oil industry, it was developed an extraction system by ionic flocculation with surfactant. The ionic flocculation relies on the reaction of carboxylate surfactant and calcium íons, yielding in an insoluble surfactant that under stirring, aggregates forming floc capable of attracting the organic matter by adsorption. In this work was used base soap as ionic surfactant in the flocculation process and evaluated phenol removal efficiency in relation to the following parameters: surfactant concentration, phenol, calcium and electrolytes, stirring speed, contact time, temperature and pH. The flocculation of the surfactant occurred in the effluent (initial phenol concentration = 100 ppm) reaching 65% of phenol removal to concentrations of 1300 ppm and calcium of 1000 ppm, respectively, at T = 35 °C, pH = 9.7, stirring rate = 100 rpm and contact time of 5 minutes. The permanence of the flocs in an aqueous medium promotes desorption of the phenol from the flake surface to the solution, reaching 90% of desorption at a time of 150 minutes, and the study of desorption kinetics showed that Lagergren model of pseudo-first order was adequate to describe the phenol desorption. These results shows that the process may configure a new alternative of treatment in regard the removal of phenol of aqueous effluent of oil industry.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The release of nitrogen compounds in water bodies can result in many environmental problems, so treat wastewater, such as sewage in order to remove not only organic matter but also nitrogen has been studied a few decades. From the above, the objective of this study was to evaluate the performance of a structured bed reactor, continuous flow, with recirculation, in removing organic matter and nitrogen present in wastewater under different cycles of intermittent aeration (AI) and to evaluate the influence of these cycles in the development of nitrifying bacteria (Oxidizing Bacteria Ammonia - BOA and Bacteria Oxidizing Nitrite - BON) and denitrifying (DESN) adhered (Support Material - MS) and suspension (Effluent - EF and sludge - LD). The reactor used has usable volume of 9.4 L. As support materials (MS) polyurethane foam was used, cut and fixed in PVC rods. 3 were worked aeration phases (AE) and non-aeration (AN) at different stage: Stage 1 (4 h EA / AN 2H); Stage 2 (2H EA / AN 1 h) and Phase 3 (2H EA / AN 2 h). During all hydraulic detention time phases was kept at 16 h and the effluent recirculated at a rate of 3 times the inflow. Were analyzed: pH, total alkalinity, temperature, chemical oxygen demand (COD), Biochemical Oxygen Demand (BOD), nitrogen Kjeldhl Total (NKT), ammonia-N-N-NH4+, nitrito-N-NO2+andnitrato-NO3-. The concentration of BOA, BON and DESN was determined using the number More Provável.gSSV-1 (NMP.gSSV-1). In phase 1 the percentage removal NTK N-NH4+ and NT was 76±10%, 70±21% and 67±10% respectively. In Phase 2 80±15% of removel NKT, 86±15% of N-NH4+ e 68±9% of removel NT e na Fase 3 de 58±20%, 72±28% and 41±6% of NKT, N-NH4+ of NT, respectively. The denitrification efficiency in stage 3 was over 70%, indicating that occurred in the reactor the process of simultaneous nitrification and denitrification (NDS). DQOT the removal percentages were 88 ± 4% in Phase 1, 94 ± 7 in Phase 2 and 90± 11% in Phase 3. The multivariate ANOVA applied to NMP.gSSV-1, it indicated that there was significant (F: 20,2, p <0,01) between the analyzed concentration of organisms AI in different cycles, but the differences between NMP.gSSV-1 depends not only isolated factors but of which means, and phase groups being analysis. From the results it is concluded that the working system is efficient in terms of nitrogen removal and organic matter, and that the stage with the highest availability of Dissolved Oxygen (DO) and C/N ratio (Step 2), was the one obtained the lower concentrations of organic matter effluents and N-NH4+. Hinted that there was a significant difference between the concentration (NMP.100mL-1) of the analyzed organizations (BOA, BON and DESN), but this difference does not depend on factors alone but of which means (MS, EF or LD), stages (1, 2 or 3) and groups (BOA, BON and DESN) is being considered.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effluents released by the textile industry have high concentrations of alkali, carbohydrates, proteins, in addition to colors containing heavy metals. Therefore, a filter was prepared aiming primarily to the removal of color. In order to prepare this filter, rice hulls and diatomite were used, which have in their structure, basically amorphous hydrated silica. The silica exists in three crystalline forms: quartz, tridymite and cristobalite. In accordance with the above considerations, this study was divided into two stages; the first corresponds to the preparation of the filter and the second to carry out the tests in the effluent/filter in order to verify the efficiency of the color removal. First, the raw material was subjected to a chemical analysis and XRD, and then the diatomite was mixed, via humid, with a planetarium windmill with 20 %, 40 %, 60 % and 80 % of rice husk ash. To the mixture, 5 % carboxymethylcellulose (CMC) was added as a binder at room temperature. The samples were uniaxially compacted into metallic matrix of 0.3 x 0.1 cm² of area at a pressure of 167 MPa by means of hydraulic press and then sintered at temperatures of 1,000 °C, 1,200 °C and 1,400 °C for 1 h and submitted to granulometry test using laser, linear retraction, water absorption, apparent porosity and resistance to bending, DTA, TMA and XRD. To examine the pore structure of the samples scanning electron microscope (SEM) was used. Also tests were carried out in a mercury porosimeter to verify the average size of the pores and real density of the samples. In the second stage, samples of the effluent were collected from a local industry, whose name will be preserved, located in Igapó, in the State of Rio Grande do Norte - RN. The effluent was first pretreated before filtration and then subjected to a treatment of flotation. The effluent was then characterized before and after filtration, with parameters of color, turbidity, suspended solids, pH, chemical and biochemical oxygen demand (COD and BOD). Thus, through the XRD analysis the formation of cristobalite α in all samples was observed. The best average size of pore was found to be 1.75 μm with 61.04 % apparent porosity, thus obtaining an average 97.9 % color removal and 99.8 % removal of suspended solid