996 resultados para template process
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para a obtenção do grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
1st ASPIC International Congress
Resumo:
A backside protein-surface imprinting process is presented herein as a novel way to generate specific synthetic antibody materials. The template is covalently bonded to a carboxylated-PVC supporting film previously cast on gold, let to interact with charged monomers and surrounded next by another thick polymer. This polymer is then covalently attached to a transducing element and the backside of this structure (supporting film plus template) is removed as a regular “tape”. The new sensing layer is exposed after the full template removal, showing a high density of re-binding positions, as evidenced by SEM. To ensure that the templates have been efficiently removed, this re-binding layer was cleaned further with a proteolytic enzyme and solution washout. The final material was named MAPS, as in the back-side reading of SPAM, because it acts as a back-side imprinting of this recent approach. It was able to generate, for the first time, a specific response to a complex biomolecule from a synthetic material. Non-imprinted materials (NIMs) were also produced as blank and were used as a control of the imprinting process. All chemical modifications were followed by electrochemical techniques. This was done on a supporting film and transducing element of both MAPS and NIM. Only the MAPS-based device responded to oxLDL and the sensing layer was insensitive to other serum proteins, such as myoglobin and haemoglobin. Linear behaviour between log(C, μg mL−1) versus charged tranfer resistance (RCT, Ω) was observed by electrochemical impedance spectroscopy (EIS). Calibrations made in Fetal Calf Serum (FCS) were linear from 2.5 to 12.5 μg mL−1 (RCT = 946.12 × log C + 1590.7) with an R-squared of 0.9966. Overall, these were promising results towards the design of materials acting close to the natural antibodies and applied to practical use of clinical interest.
Resumo:
Dissertation presented to obtain the Ph.D degree in Biology
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia Civil Perfil de Estruturas e Geotecnia
Resumo:
Os sistemas de perceção visual são das principais fontes de informação sensorial utilizadas pelos robôs autónomos, para localização e navegação em diferentes meios de operação. O objetivo passa por obter uma grande quantidade de informação sobre o ambiente que a câmara está a visualizar, processar e extrair informação que permita realizar as tarefas de uma forma e ciente. Uma informação em particular que os sistemas de visão podem fornecer, e a informação tridimensional acerca do meio envolvente. Esta informação pode ser adquirida recorrendo a sistemas de visão monoculares ou com múltiplas câmaras. Nestes sistemas a informação tridimensional pode ser obtida recorrendo a técnica de triangulação, tirando partido do conhecimento da posição relativa entre as câmaras. No entanto, para calcular as coordenadas de um ponto tridimensional no referencial da câmara e necessário existir correspondência entre pontos comuns às imagens adquiridas pelo sistema. No caso de más correspondências a informação 3D e obtida de forma incorreta. O problema associado à correspondência de pontos pode ser agravado no caso das câmaras do sistema terem características intrínsecas diferentes nomeadamente: resolução, abertura da lente, distorção. Outros fatores como as orientações e posições das câmaras também podem condicionar a correspondência de pontos. Este trabalho incide sobre problemática de correspondência de pontos existente no processo de cálculo da informação tridimensional. A presente dissertação visa o desenvolvimento de uma abordagem de correspondência de pontos para sistemas de visão no qual é conhecida a posição relativa entre câmaras.
Resumo:
Recent Advances in Mechanics and Materials in Design
Resumo:
Dissertação para obtenção do Grau de Doutor em Bioengenharia
Resumo:
Until this day, the most efficient Cu(In,Ga)Se2 thin film solar cells have been prepared using a rather complex growth process often referred to as three-stage or multistage. This family of processes is mainly characterized by a first step deposited with only In, Ga and Se flux to form a first layer. Cu is added in a second step until the film becomes slightly Cu-rich, where-after the film is converted to its final Cu-poor composition by a third stage, again with no or very little addition of Cu. In this paper, a comparison between solar cells prepared with the three-stage process and a one-stage/in-line process with the same composition, thickness, and solar cell stack is made. The one-stage process is easier to be used in an industrial scale and do not have Cu-rich transitions. The samples were analyzed using glow discharge optical emission spectroscopy, scanning electron microscopy, X-ray diffraction, current–voltage-temperature, capacitance-voltage, external quantum efficiency, transmission/reflection, and photoluminescence. It was concluded that in spite of differences in the texturing, morphology and Ga gradient, the electrical performance of the two types of samples is quite similar as demonstrated by the similar J–V behavior, quantum spectral response, and the estimated recombination losses.
Resumo:
Based on the report for “Project IV” unit of the PhD programme on Technology Assessment (Doctoral Conference) at Universidade Nova de Lisboa (December 2011). This thesis research has the supervision of António Moniz (FCT-UNL and ITAS-KIT) and Michael Decker (Karlsruhe Institute of Technology-ITAS). Other members of the thesis committee are Carlos Alberto da Silva (University of Évora), José Maria de Albuquerque (Institute of Welding and Quality), Lotte Steuten (University of Twente), Mário Forjaz Secca (FCT-UNL) and Nelson Chibeles Martins (FCT-UNL).
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia e Gestão Industrial
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
Background: Allergic rhinitis and asthma (ARA) are chronic inflammatory diseases of the airways that often coexist in children. The only tool to assess the ARA control, the Control of Allergic Rhinitis and Asthma Test (CARAT) is to be used by adults. We aimed to develop the Pediatric version of Control of Allergic Rhinitis and Asthma Test (CARATkids) and to test its comprehensibility in children with 4 to 12 years of age. Methods: The questionnaire development included a literature review of pediatric questionnaires on asthma and/or rhinitis control and two consensus meetings of a multidisciplinary group. Cognitive testing was carried out in a cross-sectional qualitative study using cognitive interviews. Results: Four questionnaires to assess asthma and none to assess rhinitis control in children were identified. The multidisciplinary group produced a questionnaire version for children with 17 questions with illustrations and dichotomous (yes/no) response format. The version for caregivers had 4-points and dichotomous scales. Twenty-nine children, 4 to 12 years old, and their caregivers were interviewed. Only children over 6 years old could adequately answer the questionnaire. A few words/expressions were not fully understood by children of 6 to 8 years old. The drawings illustrating the questions were considered helpful by children and caregivers. Caregivers considered the questionnaire complete and clear and preferred dichotomous over the 4-points scales. The proportion of agreement between children and their caregivers was 61%. The words/expressions that were difficult to understand were amended. Conclusion: CARATkids, the first questionnaire to assess a child’s asthma and rhinitis control was developed and its content validity was assured. Cognitive testing showed that CARATKids is well-understood by children 6 to 12 years old. The questionnaire’s measurement properties can now be assessed in a validation study.