888 resultados para surveillance system
Resumo:
The goal of this work is to develop a magnetic-based passive and wireless pressure sensor for use in biomedical applications. Structurally, the pressure sensor, referred to as the magneto-harmonic pressure sensor, is composed of two magnetic elements: a magnetically-soft material acts as a sensing element, and a magnetically hard material acts as a biasing element. Both elements are embedded within a rigid sensor body and sealed with an elastomer pressure membrane. Upon excitation of an externally applied AC magnetic field, the sensing element is capable of producing higher-order magnetic signature that is able to be remotely detected with an external receiving coil. When exposed to environment with changing ambient pressure, the elastomer pressure membrane of pressure sensor is deflected depending on the surrounding pressure. The deflection of elastomer membrane changes the separation distance between the sensing and biasing elements. As a result, the higher-order harmonic signal emitted by the magnetically-soft sensing element is shifted, allowing detection of pressure change by determining the extent of the harmonic shifting. The passive and wireless nature of the sensor is enabled with an external excitation and receiving system consisting of an excitation coil and a receiving coil. These unique characteristics made the sensor suitable to be used for continuous and long-term pressure monitoring, particularly useful for biomedical applications which often require frequent surveillance. In this work, abdominal aortic aneurysm is selected as the disease model for evaluation the performance of pressure sensor and system. Animal model, with subcutaneous sensor implantation in mice, was conducted to demonstrate the efficacy and feasibility of pressure sensor in biological environment.
Resumo:
The Food and Drug Administration (FDA) is responsible for risk assessment and risk management in the post-market surveillance of the U.S. medical device industry. One of the FDA regulatory mechanisms, the Medical Device Reporting System (MDR) is an adverse event reporting system intended to provide the FDA with advance warning of device problems. It includes voluntary reporting for individuals, and mandatory reporting for device manufacturers. ^ In a study of alleged breast implant safety problems, this research examines the organizational processes by which the FDA gathers data on adverse events and uses adverse event reporting systems to assess and manage risk. The research reviews the literature on problem recognition, risk perception, and organizational learning to understand the influence highly publicized events may have on adverse event reporting. Understanding the influence of an environmental factor, such as publicity, on adverse event reporting can provide insight into the question of whether the FDA's adverse event reporting system operates as an early warning system for medical device problems. ^ The research focuses on two main questions. The first question addresses the relationship between publicity and the voluntary and mandatory reporting of adverse events. The second question examines whether government agencies make use of these adverse event reports. ^ Using quantitative and qualitative methods, a longitudinal study was conducted of the number and content of adverse event reports regarding breast implants filed with the FDA's medical device reporting system during 1985–1991. To assess variation in publicity over time, the print media were analyzed to identify articles related to breast implant failures. ^ The exploratory findings suggest that an increase in media activity is related to an increase in voluntary reporting, especially following periods of intense media coverage of the FDA. However, a similar relationship was not found between media activity and manufacturers' mandatory adverse event reporting. A review of government committee and agency reports on the FDA published during 1976–1996 produced little evidence to suggest that publicity or MDR information contributed to problem recognition, agenda setting, or the formulation of policy recommendations. ^ The research findings suggest that the reporting of breast implant problems to FDA may reflect the perceptions and concerns of the reporting groups, a barometer of the volume and content of media attention. ^
Resumo:
BACKGROUND & AIMS: Refractory ascites (RA) affects 10% of patients with advanced cirrhosis and ascites. Usual therapy includes large volume paracentesis, and in selected patients, a transjugular portosystemic shunt (TIPS). These therapies may be associated with increased morbidity: paracentesis may induce circulatory dysfunction and impair quality of life and TIPS may induce encephalopathy and is associated with increased mortality in patients with severe liver dysfunction. We present the results of a multicenter, non-randomized trial to assess the safety and efficacy of a new automated pump system for treatment of RA. METHODS: Forty patients at 9 centers (February 2010-June 2011) received an implanted pump for the automated removal of ascites from the peritoneal cavity into the bladder, from where it was eliminated through normal urination. Patients were followed-up for 6months. The primary study outcome was safety. Secondary outcomes included recurrence of tense ascites and pump performance. RESULTS: Surgical complications occurred early in the study and became less frequent. The pump system removed 90% of the ascites and significantly reduced the median number of large volume paracentesis per month [3.4 (range 1-6) vs. 0.2 (range 0-4); p <0.01]. Cirrhosis-related adverse events decreased along follow-up. CONCLUSIONS: The automated pump seems an efficacious tool to move out ascites from the peritoneal cavity to the bladder. Its safety is still moderate, but a broad use in different countries will improve the surgical technique as well as the medical surveillance. A prospective randomized clinical trial vs. large volume paracentesis is underway to confirm these preliminary results.
Resumo:
BACKGROUND Rheumatic heart disease accounts for up to 250 000 premature deaths every year worldwide and can be regarded as a physical manifestation of poverty and social inequality. We aimed to estimate the prevalence of rheumatic heart disease in endemic countries as assessed by different screening modalities and as a function of age. METHODS We searched Medline, Embase, the Latin American and Caribbean System on Health Sciences Information, African Journals Online, and the Cochrane Database of Systematic Reviews for population-based studies published between Jan 1, 1993, and June 30, 2014, that reported on prevalence of rheumatic heart disease among children and adolescents (≥5 years to <18 years). We assessed prevalence of clinically silent and clinically manifest rheumatic heart disease in random effects meta-analyses according to screening modality and geographical region. We assessed the association between social inequality and rheumatic heart disease with the Gini coefficient. We used Poisson regression to analyse the effect of age on prevalence of rheumatic heart disease and estimated the incidence of rheumatic heart disease from prevalence data. FINDINGS We included 37 populations in the systematic review and meta-analysis. The pooled prevalence of rheumatic heart disease detected by cardiac auscultation was 2·9 per 1000 people (95% CI 1·7-5·0) and by echocardiography it was 12·9 per 1000 people (8·9-18·6), with substantial heterogeneity between individual reports for both screening modalities (I(2)=99·0% and 94·9%, respectively). We noted an association between social inequality expressed by the Gini coefficient and prevalence of rheumatic heart disease (p=0·0002). The prevalence of clinically silent rheumatic heart disease (21·1 per 1000 people, 95% CI 14·1-31·4) was about seven to eight times higher than that of clinically manifest disease (2·7 per 1000 people, 1·6-4·4). Prevalence progressively increased with advancing age, from 4·7 per 1000 people (95% CI 0·0-11·2) at age 5 years to 21·0 per 1000 people (6·8-35·1) at 16 years. The estimated incidence was 1·6 per 1000 people (0·8-2·3) and remained constant across age categories (range 2·5, 95% CI 1·3-3·7 in 5-year-old children to 1·7, 0·0-5·1 in 15-year-old adolescents). We noted no sex-related differences in prevalence (p=0·829). INTERPRETATION We found a high prevalence of rheumatic heart disease in endemic countries. Although a reduction in social inequalities represents the cornerstone of community-based prevention, the importance of early detection of silent rheumatic heart disease remains to be further assessed. FUNDING UBS Optimus Foundation.
Resumo:
A rapid and simple DNA labeling system has been developed for disposable microarrays and has been validated for the detection of 117 antibiotic resistance genes abundant in Gram-positive bacteria. The DNA was fragmented and amplified using phi-29 polymerase and random primers with linkers. Labeling and further amplification were then performed by classic PCR amplification using biotinylated primers specific for the linkers. The microarray developed by Perreten et al. (Perreten, V., Vorlet-Fawer, L., Slickers, P., Ehricht, R., Kuhnert, P., Frey, J., 2005. Microarray-based detection of 90 antibiotic resistance genes of gram-positive bacteria. J.Clin.Microbiol. 43, 2291-2302.) was improved by additional oligonucleotides. A total of 244 oligonucleotides (26 to 37 nucleotide length and with similar melting temperatures) were spotted on the microarray, including genes conferring resistance to clinically important antibiotic classes like β-lactams, macrolides, aminoglycosides, glycopeptides and tetracyclines. Each antibiotic resistance gene is represented by at least 2 oligonucleotides designed from consensus sequences of gene families. The specificity of the oligonucleotides and the quality of the amplification and labeling were verified by analysis of a collection of 65 strains belonging to 24 species. Association between genotype and phenotype was verified for 6 antibiotics using 77 Staphylococcus strains belonging to different species and revealed 95% test specificity and a 93% predictive value of a positive test. The DNA labeling and amplification is independent of the species and of the target genes and could be used for different types of microarrays. This system has also the advantage to detect several genes within one bacterium at once, like in Staphylococcus aureus strain BM3318, in which up to 15 genes were detected. This new microarray-based detection system offers a large potential for applications in clinical diagnostic, basic research, food safety and surveillance programs for antimicrobial resistance.
Resumo:
The field of animal syndromic surveillance (SyS) is growing, with many systems being developed worldwide. Now is an appropriate time to share ideas and lessons learned from early SyS design and implementation. Based on our practical experience in animal health SyS, with additions from the public health and animal health SyS literature, we put forward for discussion a 6-step approach to designing SyS systems for livestock and poultry. The first step is to formalise policy and surveillance goals which are considerate of stakeholder expectations and reflect priority issues (1). Next, it is important to find consensus on national priority diseases and identify current surveillance gaps. The geographic, demographic, and temporal coverage of the system must be carefully assessed (2). A minimum dataset for SyS that includes the essential data to achieve all surveillance objectives while minimizing the amount of data collected should be defined. One can then compile an inventory of the data sources available and evaluate each using the criteria developed (3). A list of syndromes should then be produced for all data sources. Cases can be classified into syndrome classes and the data can be converted into time series (4). Based on the characteristics of the syndrome-time series, the length of historic data available and the type of outbreaks the system must detect, different aberration detection algorithms can be tested (5). Finally, it is essential to develop a minimally acceptable response protocol for each statistical signal produced (6). Important outcomes of this pre-operational phase should be building of a national network of experts and collective action and evaluation plans. While some of the more applied steps (4 and 5) are currently receiving consideration, more emphasis should be put on earlier conceptual steps by decision makers and surveillance developers (1-3).
Resumo:
Space debris in geostationary orbits may be detected with optical telescopes when the objects are illuminated by the Sun. The advantage compared to Radar can be found in the illumination: radar illuminates the objects and thus the detection sensitivity depletest proportional to the fourth power of the d istance. The German Space Operation Center, GSOC, together with the Astronomical Institute of the University of Bern, AIUB, are setting up a telescope system called SMARTnet to demonstrate the capability of performing geostationary surveillance. Such a telescope system will consist of two telescopes on one mount: a smaller telescope with an aperture of 20cm will serve for fast survey while the larger one, a telescope with an aperture of 50cm, will be used for follow-up observations. The telescopes will be operated by GSOC from Oberpfaffenhofen by the internal monitoring and control system called SMARTnetMAC. The observation plan will be generated by MARTnetPlanning seven days in advance by applying an optimized planning scheduler, taking into account fault time like cloudy nights, priority of objects etc. From each picture taken, stars will be identified and everything not being a star is treated as a possible object. If the same object can be identified on multiple pictures within a short time span, the trace is called a tracklet. In the next step, several tracklets will be correlated to identify individual objects, ephemeris data for these objects are generated and catalogued . This will allow for services like collision avoidance to ensure safe operations for GSOC’s satellites. The complete data processing chain is handled by BACARDI, the backbone catalogue of relational debris information and is presented as a poster.
Resumo:
BACKGROUND: This study focused on the descriptive analysis of cattle movements and farm-level parameters derived from cattle movements, which are considered to be generically suitable for risk-based surveillance systems in Switzerland for diseases where animal movements constitute an important risk pathway. METHODS: A framework was developed to select farms for surveillance based on a risk score summarizing 5 parameters. The proposed framework was validated using data from the bovine viral diarrhoea (BVD) surveillance programme in 2013. RESULTS: A cumulative score was calculated per farm, including the following parameters; the maximum monthly ingoing contact chain (in 2012), the average number of animals per incoming movement, use of mixed alpine pastures and the number of weeks in 2012 a farm had movements registered. The final score for the farm depended on the distribution of the parameters. Different cut offs; 50, 90, 95 and 99%, were explored. The final scores ranged between 0 and 5. Validation of the scores against results from the BVD surveillance programme 2013 gave promising results for setting the cut off for each of the five selected farm level criteria at the 50th percentile. Restricting testing to farms with a score ≥ 2 would have resulted in the same number of detected BVD positive farms as testing all farms, i.e., the outcome of the 2013 surveillance programme could have been reached with a smaller survey. CONCLUSIONS: The seasonality and time dependency of the activity of single farms in the networks requires a careful assessment of the actual time period included to determine farm level criteria. However, selecting farms in the sample for risk-based surveillance can be optimized with the proposed scoring system. The system was validated using data from the BVD eradication program. The proposed method is a promising framework for the selection of farms according to the risk of infection based on animal movements.
Resumo:
Syndromic surveillance (SyS) systems currently exploit various sources of health-related data, most of which are collected for purposes other than surveillance (e.g. economic). Several European SyS systems use data collected during meat inspection for syndromic surveillance of animal health, as some diseases may be more easily detected post-mortem than at their point of origin or during the ante-mortem inspection upon arrival at the slaughterhouse. In this paper we use simulation to evaluate the performance of a quasi-Poisson regression (also known as an improved Farrington) algorithm for the detection of disease outbreaks during post-mortem inspection of slaughtered animals. When parameterizing the algorithm based on the retrospective analyses of 6 years of historic data, the probability of detection was satisfactory for large (range 83-445 cases) outbreaks but poor for small (range 20-177 cases) outbreaks. Varying the amount of historical data used to fit the algorithm can help increasing the probability of detection for small outbreaks. However, while the use of a 0·975 quantile generated a low false-positive rate, in most cases, more than 50% of outbreak cases had already occurred at the time of detection. High variance observed in the whole carcass condemnations time-series, and lack of flexibility in terms of the temporal distribution of simulated outbreaks resulting from low reporting frequency (monthly), constitute major challenges for early detection of outbreaks in the livestock population based on meat inspection data. Reporting frequency should be increased in the future to improve timeliness of the SyS system while increased sensitivity may be achieved by integrating meat inspection data into a multivariate system simultaneously evaluating multiple sources of data on livestock health.
Resumo:
The purpose of this research and development project was to develop a method, a design, and a prototype for gathering, managing, and presenting data about occupational injuries.^ State-of-the-art systems analysis and design methodologies were applied to the long standing problem in the field of occupational safety and health of processing workplace injuries data into information for safety and health program management as well as preliminary research about accident etiologies. The top-down planning and bottom-up implementation approach was utilized to design an occupational injury management information system. A description of a managerial control system and a comprehensive system to integrate safety and health program management was provided.^ The project showed that current management information systems (MIS) theory and methods could be applied successfully to the problems of employee injury surveillance and control program performance evaluation. The model developed in the first section was applied at The University of Texas Health Science Center at Houston (UTHSCH).^ The system in current use at the UTHSCH was described and evaluated, and a prototype was developed for the UTHSCH. The prototype incorporated procedures for collecting, storing, and retrieving records of injuries and the procedures necessary to prepare reports, analyses, and graphics for management in the Health Science Center. Examples of reports, analyses, and graphics presenting UTHSCH and computer generated data were included.^ It was concluded that a pilot test of this MIS should be implemented and evaluated at the UTHSCH and other settings. Further research and development efforts for the total safety and health management information systems, control systems, component systems, and variable selection should be pursued. Finally, integration of the safety and health program MIS into the comprehensive or executive MIS was recommended. ^
Resumo:
Vorbesitzer: O. Borelli
Resumo:
Very few studies have described MUP-1 concentrations and measured prevalence of Laboratory Animal Allergy (LAA) at such a diverse institution as the private medical school (MS) that is the focus of this study. Air sampling was performed in three dissimilar animal research facilities at MS and quantitated using a commercially available ELISA. Descriptive data was obtained from an anonymous laboratory animal allergy survey given to both animal facility employees and the researchers who utilize these facilities alike. Logistic regression analysis was then implemented to investigate specific factors that may be predictive of developing LAA as well as factors influencing the reporting of LAA symptoms to the occupational health program. Concentrations of MUP-1 detected ranged from below detectable levels (BDL) to a peak of 22.64 ng/m3 . Overall, 68 employees with symptoms claimed they improved while away from work and only 25 employees reported their symptoms to occupational health. Being Vietnamese, a smoker, not wearing a mask, and working in any facility longer than one year were all significant predictors of having LAA symptoms. This study suggests a LAA monitoring system that relies on self-reporting can be inadequate in estimating LAA problems. In addition, efforts need to be made to target training and educational materials for non-native English speaking employees to overcome language and cultural barriers and address their specific needs. ^
Resumo:
Public health surveillance programs for vaccine preventable diseases (VPD) need functional quality assurance (QA) in order to operate with high quality activities to prevent preventable communicable diseases from spreading in the community. Having a functional QA plan can assure the performance and quality of a program without putting excessive stress on the resources. A functional QA plan acts as a check on the quality of day-to-day activities performed by the VPD surveillance program while also providing data that would be useful for evaluating the program. This study developed a QA plan that involves collection, collation, analysis and reporting of information based on standardized (predetermined) formats and indicators as an integral part of routine work for the vaccine preventable disease surveillance program at the City of Houston Department of Health and Human Services. The QA plan also provides sampling and analysis plans for assessing various QA indicators, as well as recommendations to the Houston Department of Health and Humans Services for implementation of the QA plan. The QA plan developed for VPD surveillance in the City of Houston is intended to be a low cost system that could serve as a template for QA plans as part of other public health programs not only in the city or the nation, but could be adapted for use anywhere across the globe. Having a QA plan for VPD surveillance in the City of Houston would serve well for the funding agencies like the CDC by assuring that the resources are being expended efficiently, while achieving the real goal of positively impacting the health and lives of the recipient/target population. ^
Resumo:
Invasive pneumococcal disease (IPD) causes significant health burden in the US, is responsible for the majority of bacterial meningitis, and causes more deaths than any other vaccine preventable bacterial disease in the US. The estimated National IPD rate is 14.3 cases per 100,000 population with a case-fatality rate of 1.5 cases per 100,000 population. Although cases of IPD are routinely reported to the local health department in Harris County Texas, the incidence (IR) and case-fatality (CFR) rates have not been reported. Additionally, it is important to know which serotypes of S. pneumoniae are circulating in Harris County Texas and to determine if ‘replacement disease’ is occurring. ^ This study reported incidence and case-fatality rates from 2003 to 2009, and described the trends in IPD, including the IPD serotypes circulating in Harris County Texas during the study period, particularly in 2008 and 2010. Annual incidence rates were calculated and reported for 2003 to 2009, using complete surveillance-year data. ^ Geographic information system (GIS) software was used to create a series of maps of the data reported during the study period. Cluster and outlier analysis and hot spot analysis were conducted using both case counts by census tract and disease rate by census tract. ^ IPD age- and race-adjusted IR for Harris County Texas and their 95% confidence intervals (CIs) were 1.40 (95% CI 1.0, 1.8), 1.71 (95% CI 1.24, 2.17), 3.13 (95% CI 2.48, 3.78), 3.08 (95% CI 2.43, 3.74), 5.61 (95% CI 4.79, 6.43), 8.11 (95% CI 7.11, 9.1), and 7.65 (95% CI 6.69, 8.61) for the years 2003 to 2009, respectively (rates were age- and race-adjusted to each year's midyear US population estimates). A Poisson regression model demonstrated a statistically significant increasing trend of about 32 percent per year in the IPD rates over the course of the study period. IPD age- and race-adjusted case-fatality rates (CFR) for Harris County Texas were also calculated and reported. A Poisson regression model demonstrated a statistically significant increasing trend of about 26 percent per year in the IPD case-fatality rates from 2003 through 2009. A logistic regression model associated the risk of dying from IPD to alcohol abuse (OR 4.69, 95% CI 2.57, 8.56) and to meningitis (OR 2.42, 95% CI 1.46, 4.03). ^ The prevalence of non-vaccine serotypes (NVT) among IPD cases with serotyped isolates was 98.2 percent. In 2008, the year with the sample more geographically representative of all areas of Harris County Texas, the prevalence was 96 percent. Given these findings, it is reasonable to conclude that ‘replacement disease’ is occurring in Harris County Texas, meaning that, the majority of IPD is caused by serotypes not included in the PCV7 vaccine. Also in conclusion, IPD rates increased during the study period in Harris County Texas.^