999 resultados para sub-arc
Resumo:
Experimental research on a 150 kW arc-heated plasma testing facility was conducted. Stable plasma jets with different gas compositions, temperatures and velocities were obtained at chamber pressure between 400 Pa – 100 kPa. Stagnation ablation experiments were conducted on samples of typical super alloys used for thermal protection systems. The microstructure and hardness of alloys before and after ablation were compared.
Resumo:
Gold Coast Water is responsible for the management of the water and wastewater assets of the City of the Gold Coast on Australia’s east coast. Treated wastewater is released at the Gold Coast Seaway on an outgoing tide in order for the plume to be dispersed before the tide changes and renters the Broadwater estuary. Rapid population growth over the past decade has placed increasing demands on the receiving waters for the release of the City’s effluent. The Seaway SmartRelease Project is designed to optimise the release of the effluent from the City’s main wastewater treatment plant in order to minimise the impact of the estuarine water quality and maximise the cost efficiency of pumping. In order to do this an optimisation study that involves water quality monitoring, numerical modelling and a web based decision support system was conducted. An intensive monitoring campaign provided information on water levels, currents, winds, waves, nutrients and bacterial levels within the Broadwater. These data were then used to calibrate and verify numerical models using the MIKE by DHI suite of software. The decision support system then collects continually measured data such as water levels, interacts with the WWTP SCADA system, runs the models in forecast mode and provides the optimal time window to release the required amount of effluent from the WWTP. The City’s increasing population means that the length of time available for releasing the water with minimal impact may be exceeded within 5 years. Optimising the release of the treated water through monitoring, modelling and a decision support system has been an effective way of demonstrating the limited environmental impact of the expected short term increase in effluent disposal procedures. (PDF contains 5 pages)
Resumo:
In this reservoir, the parameters being assessed are very important in the aspect of fish culture. These parameters are: physical parameters which includes temperature (O), Transparency (M).Chemical parameters include: Dissolve oxygen (mg/l) pH concentration and the Biological Parameters which include phytoplankton and zooplankton. The phytoplankton and zooplankton identification and estimation were carried out in the NIFFR Limnology Laboratory, (Green House), New Bussa. Each identified zooplankton and phytoplankton species was placed according to its major group e.g. zooplankton was grouped into three families, Roifera, Cladocera and Copepods. During this study period it was observed that copepods have the highest total number of zooplankton both beside the poultry and monk (station 'A'&'B'). Water temperature of station 'A' (beside the poultry house) ranges from 27 C-29, 5 c also same station 'B' (near the monk). Dissolve oxygen station 'A' range from 6.30mg/l-7.40mg/l while that of station 'B' ranges from 6.20mg/7.50mg/l, turbidity reading of station A'ranges from 0.19m-0.3m while station 'B' ranges from 0.22m-0.37m. The last parameter, which is pH concentration, in both stations 8.2 was observed this is an indication that the pH was constant. According to some literature review all the water parameter figures obtained were good for fish culture
Resumo:
A spectral-filter method is numerically demonstrated to obtain sub-5 fs pulses by using femtosecond filamentation in fused silica. Instead of employing spectral phase compensation, by properly employing a high-pass filter to select the broadened high-frequency spectra that are located almost in phase in the tailing edge of the self-compressed pulses owing to self-steepening, as short as single-cycle pulses can be obtained. For instance, for an input pulse with a duration of 50 fs and energy 2.2 mu J, the minimum pulse duration can reach to similar to 4 fs (about 1.5 cycles) by applying a proper spectral filter. (C) 2008 Optical Society of America
Resumo:
We propose a scheme for sub-half-wavelength atom localization in a four-level ladder-type atomic system, which is coupled by two classical standing-wave fields. We find that one of the standing-wave fields can help in enhancing the localization precision, and the other is of crucial importance in increasing the detecting probability and leading sub-half-wavelength localization.
Resumo:
We theoretically propose a method of generating a single sub-100 attosecond (as) pulse with a two-colour time-gating laser field. The field is synthesized by an 8 fs/800 nm (three optical cycles) pulse and a 24 fs/2400 nm (three optical cycles) pulse with an optimal time delay between them. In our simulation, we obtain a supercontinuum with an extremely broad spectrum of 150 eV and generate an isolated attosecond pulse with 96 as pulse duration without any dispersion compensation.
Resumo:
A pulse-compression scheme based on cascade of filamentation and hollow fiber has been demonstrated, Pulses with duration of sub-5 fs and energy of 0.2 mJ near 800 nm have been generated by compressing the similar to 40 fs pulses from a commercial laser system. This method is promising to generate near monocycle high energy pulses. [GRAPHICS] Measured autocorrelation curve of the final compressed pulses with duration of sub-5 fs (black solid) and the simulated autocorrelation curve of 4.6 fs pulse near 800 rim (red dash) (C) 2008 by Astro Ltd. Published exclusively by WILEY-VCH Verlag GmbH & Co. KGaA
Resumo:
This thesis describes the development of low-noise heterodyne receivers at THz frequencies for submillimeter astronomy using Nb-based superconductor-insulator-superconductor (SIS) tunneling junctions. The mixers utilize a quasi-optical configuration which consists of a planar twin-slot antenna and antisymmetrically-fed two-junctions on an antireflection-coated silicon hyperhemispherical lens. On-chip integrated tuning circuits, in the form of microstrip lines, are used to obtain maximum coupling efficiency in the designed frequency band. To reduce the rf losses in the integrated tuning circuits above the superconducting Nb gap frequency (~ 700 GHz), normal-metal Al is used to replace Nb as the tuning circuits.
To account the rf losses in the micros trip lines, we calculated the surface impedance of the AI films using the nonlocal anomalous skin effect for finite thickness films. Nb films were calculated using the Mattis-Bardeen theory in the extreme anomalous limit. Our calculations show that the losses of the Al and Nb microstrip lines are about equal at 830 GHz. For Al-wiring and Nb-wiring mixers both optimized at 1050 GHz, the RF coupling efficiency of Al-wiring mixer is higher than that of Nb-wiring one by almost 50%. We have designed both Nb-wiring and Al-wiring mixers below and above the gap frequency.
A Fourier transform spectrometer (FTS) has been constructed especially for the study of the frequency response of SIS receivers. This FTS features large aperture size (10 inch) and high frequency resolution (114 MHz). The FTS spectra, obtained using the SIS receivers as direct detectors on the FTS, agree quite well with our theoretical simulations. We have also, for the first time, measured the FTS heterodyne response of an SIS mixer at sufficiently high resolution to resolve the LO and the sidebands. Heterodyne measurements of our SIS receivers with Nb-wiring or Al-wiring have yielded results which arc among the best reported to date for broadband heterodyne receivers. The Nb-wiring mixers, covering 400 - 850 GHz band with four separate fixed-tuned mixers, have uncorrected DSB receiver noise temperature around 5hv/kb to 700 GHz, and better than 540 K at 808 GHz. An Al-wiring mixer designed for 1050 GHz band has an uncorrected DSB receiver noise temperature 840 K at 1042 GHz and 2.5 K bath temperature. Mixer performance analysis shows that Nb junctions can work well up to twice the gap frequency and the major cause of loss above the gap frequency is the rf losses in the microstrip tuning structures. Further advances in THz SIS mixers may be possible using circuits fabricated with higher-gap superconductors such as NbN. However, this will require high-quality films with low RF surface resistance at THz frequencies.
Resumo:
A key to the larvae of the genera of the sub-family Orthocladiinae from Larvae and Pupae of midges of the sub-family Orthocladiinae. Parts of the key refer to the rest of the publication which is not included in this partial translation.
Resumo:
根据双中心带输运模型,对(Ce,Cu)∶LiNbO3晶体双中心非挥发全息记录进行了理论研究与优化。推导了(Ce,Cu)∶LiNbO3晶体的微观参量,采用数值方法通过严格求解模拟双中心带输运方程来模拟全息记录过程。分析了记录过程中,记录与敏化光强、Ce和Cu掺杂浓度以及晶体微观参量对(Ce,Cu)∶LiNbO3晶体双中心全息记录的影响。发现(Ce,Cu)∶LiNbO3晶体非挥发全息记录中实现高衍射效率与固定效率的主导因素是深中心Cu,在记录过程中,深中心Cu建立起了很强的空间电荷场。数值模拟的结果经过实验验
Resumo:
采用双中心记录方案在双掺杂LiNbO3∶Fe∶Rh晶体中实现了近红外非挥发全息记录,研究了LiNbO3∶Fe∶Rh晶体在633 nm,752 nm,799 nm波长下的全息记录性能。结果表明,在使用近红外记录光时,其记录灵敏度随敏化光强的变化趋势与双中心短波长记录时的不同。通过和LiNbO3∶Fe∶Mn等传统双掺杂铌酸锂晶体的近红外波段记录效果对比,发现同时掺杂Fe和Rh可增强晶体对近红外光的吸收,获得更高的浅中心Fe光生伏特系数,从而能够在LiNbO3∶Fe∶Rh晶体中实现近红外波段的光折变全息记录。