952 resultados para spiral bevel gear
Resumo:
A systematic method to improve the quality (Q) factor of RF integrated inductors is presented in this paper. The proposed method is based on the layout optimization to minimize the series resistance of the inductor coil, taking into account both ohmic losses, due to conduction currents, and magnetically induced losses, due to eddy currents. The technique is particularly useful when applied to inductors in which the fabrication process includes integration substrate removal. However, it is also applicable to inductors on low-loss substrates. The method optimizes the width of the metal strip for each turn of the inductor coil, leading to a variable strip-width layout. The optimization procedure has been successfully applied to the design of square spiral inductors in a silicon-based multichip-module technology, complemented with silicon micromachining postprocessing. The obtained experimental results corroborate the validity of the proposed method. A Q factor of about 17 have been obtained for a 35-nH inductor at 1.5 GHz, with Q values higher than 40 predicted for a 20-nH inductor working at 3.5 GHz. The latter is up to a 60% better than the best results for a single strip-width inductor working at the same frequency.
Resumo:
We present an analytic and numerical study of the effects of external fluctuations in active media. Our analytical methodology transforms the initial stochastic partial differential equations into an effective set of deterministic reaction-diffusion equations. As a result we are able to explain and make quantitative predictions on the systematic and constructive effects of the noise, for example, target patterns created out of noise and traveling or spiral waves sustained by noise. Our study includes the case of realistic noises with temporal and spatial structures.
Resumo:
BACKGROUND: Direct noninvasive visualization of the coronary vessel wall may enhance risk stratification by quantifying subclinical coronary atherosclerotic plaque burden. We sought to evaluate high-resolution black-blood 3D cardiovascular magnetic resonance (CMR) imaging for in vivo visualization of the proximal coronary artery vessel wall. METHODS AND RESULTS: Twelve adult subjects, including 6 clinically healthy subjects and 6 patients with nonsignificant coronary artery disease (10% to 50% x-ray angiographic diameter reduction) were studied with the use of a commercial 1.5 Tesla CMR scanner. Free-breathing 3D coronary vessel wall imaging was performed along the major axis of the right coronary artery with isotropic spatial resolution (1.0x1.0x1.0 mm(3)) with the use of a black-blood spiral image acquisition. The proximal vessel wall thickness and luminal diameter were objectively determined with an automated edge detection tool. The 3D CMR vessel wall scans allowed for visualization of the contiguous proximal right coronary artery in all subjects. Both mean vessel wall thickness (1.7+/-0.3 versus 1.0+/-0.2 mm) and wall area (25.4+/-6.9 versus 11.5+/-5.2 mm(2)) were significantly increased in the patients compared with the healthy subjects (both P<0.01). The lumen diameter (3.6+/-0.7 versus 3.4+/-0.5 mm, P=0.47) and lumen area (8.9+/-3.4 versus 7.9+/-3.5 mm(2), P=0.47) were similar in both groups. CONCLUSIONS: Free-breathing 3D black-blood coronary CMR with isotropic resolution identified an increased coronary vessel wall thickness with preservation of lumen size in patients with nonsignificant coronary artery disease, consistent with a "Glagov-type" outward arterial remodeling. This novel approach has the potential to quantify subclinical disease.
Resumo:
PURPOSE: Multi-hour ski mountaineering energy balance may be negative and intake below recommendations. METHODS: Athletes on the 'Patrouille des Glaciers' racecourses (17 on course Z, 27 km, +2,113 m; 11 on course A, 26 km, +1,881 m) volunteered. Pre-race measurements included body mass, stature, VO2max, and heart rate (HR) vs VO2 at simulated altitude; race measurements HR, altitude, incline, location, and food and drink intake (A). Energy expenditure (EE) was calculated from altitude corrected HR derived VO2. RESULTS: Race time was 5 h 7 min ± 44 min (mean ± SD, Z) and 5 h 51 min ± 53 min (A). Subjects spent 19.2 ± 3.2 MJ (Z), respectively, 22.6 ± 2.9 MJ (A) during the race. Energy deficit was -15.5 ± 3.9 MJ (A); intake covered 20 ± 7 % (A). Overall energy cost of locomotion (EC) was 9.9 ± 1.3 J m(-1) kg(-1) (Z), 8.0 ± 1.0 J m(-1) kg(-1) (A). Uphill EC was 11.7 ± 1 J m(-1) kg(-1) (Z, 13 % slope) and 15.7 ± 2.3 J m(-1) kg(-1) (A, 19 % slope). Race A subjects lost -1.5 ± 1.1 kg, indicating near euhydration. Age, body mass, gear mass, VO2max and EC were significantly correlated with performance; energy deficit was not. CONCLUSIONS: Energy expenditure and energy deficit of a multi-hour ski mountaineering race are very high and energy intake is below recommendations.
Resumo:
We present an analytic and numerical study of the effects of external fluctuations in active media. Our analytical methodology transforms the initial stochastic partial differential equations into an effective set of deterministic reaction-diffusion equations. As a result we are able to explain and make quantitative predictions on the systematic and constructive effects of the noise, for example, target patterns created out of noise and traveling or spiral waves sustained by noise. Our study includes the case of realistic noises with temporal and spatial structures.
Resumo:
Aminoglycoside antibiotics are ototoxic, inducing irreversible sensorineural hearing loss mediated by oxidative and excitotoxic stresses. The NF-kappaB pathway is involved in the response to aminoglycoside damage in the cochlea. However, the molecular mechanisms of this ototoxicity remain unclear. We investigated the expression of PKCzeta, a key regulator of NF-kappaB activation, in response to aminoglycoside treatment. Amikacin induced PKCzeta cleavage and nuclear translocation. These events were concomitant with chromatin condensation and paralleled the decrease in NF-kappaB (p65) levels in the nucleus. Amikacin also induced the nuclear translocation of apoptotic inducing factor (AIF). Prior treatment with aspirin prevented PKCzeta cleavage and nuclear translocation. Thus, aspirin counteracts the early effects of amikacin, thereby protecting hair cells and spiral ganglion neurons. These results demonstrate that PKCzeta acts as sentinel connecting specific survival pathways to mediate cellular responses to amikacin ototoxicity.
Resumo:
There is an increased interest in constructing Pre-Cast (PC) Twin and Triple Reinforced Concrete Box (RCB) culverts in Iowa due to the efficiency associated with their production in controlled environment and decrease of the construction time at the culvert sites. The design of the multi-barrel PC culverts is, however, based on guidelines for single-barrel cast-inplace (CIP) culverts despite that the PC and CIP culverts have different geometry. There is scarce information for multiplebarrel RCB culverts in general and even fewer on culverts with straight wingwalls as those designed by Iowa DOT. Overall, the transition from CIP to PC culverts requires additional information for improving the design specifications currently in use. Motivated by the need to fill these gaps, an experimental study was undertaken by IIHR-Hydroscience & Engineering. The goals of the study are to document flow performance curves and head losses at the culvert entrance for a various culvert geometry, flow conditions, and settings. The tests included single-, double- and triple-barrel PC and CIP culverts with two span-to-rise ratios set on mild and steep slopes. The tests also included optimization of the culvert geometry entrance by considering various configurations for the top bevel. The overall conclusion of the study is that by and large the current Iowa DOT design specifications for CIP culverts can be used for multi-barrel PC culvert design. For unsubmerged flow conditions the difference in the hydraulic performance curves and headloss coefficients for PC and CIP culverts are within the experimental uncertainty. Larger differences (specified by the study) are found for submerged conditions when the flow is increasingly constricted at the entrance in the culvert. The observed differentiation is less important for multi-barrel culverts as the influence of the wingwalls decreases with the increase of the number of barrels.
Resumo:
PURPOSE: At 7 Tesla (T), conventional static field (B0 ) projection mapping techniques, e.g., FASTMAP, FASTESTMAP, lead to elevated specific absorption rates (SAR), requiring longer total acquisition times (TA). In this work, the series of adiabatic pulses needed for slab selection in FASTMAP is replaced by a single two-dimensional radiofrequency (2D-RF) pulse to minimize TA while ensuring equal shimming performance. METHODS: Spiral gradients and 2D-RF pulses were designed to excite thin slabs in the small tip angle regime. The corresponding selection profile was characterized in phantoms and in vivo. After optimization of the shimming protocol, the spectral linewidths obtained after 2D localized shimming were compared with conventional techniques and published values from (Emir et al NMR Biomed 2012;25:152-160) in six different brain regions. RESULTS: Results on healthy volunteers show no significant difference (P > 0.5) between the spectroscopic linewidths obtained with the adiabatic (TA = 4 min) and the new low-SAR and time-efficient FASTMAP sequence (TA = 42 s). The SAR can be reduced by three orders of magnitude and TA accelerated six times without impact on the shimming performances or quality of the resulting spectra. CONCLUSION: Multidimensional pulses can be used to minimize the RF energy and time spent for automated shimming using projection mapping at high field. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.
Resumo:
As the list of states adopting the HWTD continues to grow, there is a need to evaluate how results are utilized. AASHTO T 324 does not standardize the analysis and reporting of test results. Furthermore, processing and reporting of the results among manufacturers is not uniform. This is partly due to the variation among agency reporting requirements. Some include only the midpoint rut depth, while others include the average across the entire length of the wheel track. To eliminate bias in reporting, statistical analysis was performed on over 150 test runs on gyratory specimens. Measurement location was found to be a source of significant variation in the HWTD. This is likely due to the nonuniform wheel speed across the specimen, geometry of the specimen, and air void profile. Eliminating this source of bias when reporting results is feasible though is dependent upon the average rut depth at the final pass. When reporting rut depth at the final pass, it is suggested for poor performing samples to average measurement locations near the interface of the adjoining gyratory specimens. This is necessary due to the wheel lipping on the mold. For all other samples it is reasonable to only eliminate the 3 locations furthest from the gear house. For multi‐wheel units, wheel side was also found to be significant for poor and good performing samples. After eliminating the suggested measurements from the analysis, the wheel was no longer a significant source of variation.
Resumo:
Pieces of Iowa’s Past, published by the Iowa State Capitol Tour Guides weekly during the legislative session, features historical facts about Iowa, the Capitol, and the early workings of state government. All historical publications are reproduced here with the actual spelling, punctuation, and grammar retained. January 23, 2013 THIS WEEK: Iowa’s Grasshopper Plague of 1873 BACKGROUND: Fifteen General Assembly The 15th General Assembly convened January 12 and adjourned March 19, 1874—a 67-day session. The Senate had six Democratic members, 34 Republican members, and 10 Independent members. The House of Representatives had six Democratic members, 50 Republican members, and 44 Independent members. There were a total of 150 legislators in Iowa. By 1874, the Capital had been relocated to Des Moines. The legislature had occupied the old Brick Capitol since 1858. Joseph Dysart was the Lieutenant Governor presiding in the Senate, and John Gear was Speaker of the House of Representatives. Iowa’s population at the 1870 federal census had grown to 1,194,020. Both House and Senate journals from the 15th Iowa General Assembly include several references to assisting the destitution brought on by the 1874 plague of grasshoppers in Northwestern Iowa. Senator Perkins, from the Special Committee appointed to inquire into the reports of destitution in the northwestern counties of Iowa, submitted the following report, in part: “We have examined such evidence as is attainable here, and made such inquiries of parties interested in affording temporary relief as were to be met, and are pieces satisfied in our own minds that the case is one of sufficient importance to command the attention of the State.”
Resumo:
As population ages, a growing number of older patients present the constellation of diabetes and dementia. Numerous recent studies highlight that diabetes may increase the risk for Alzheimer and vascular dementia. Among patients with previous severe hypoglycemia, that risk may even double. Inversely demented patients have about three times higher risk of hypoglycemia. Given that spiral link between hypoglycemia and dementia, the latter should be considered as a possible complication of diabetes and consistently be screened for among older diabetic patients. Furthermore, the American Diabetes Association and American Geriatric Society consensus recommends a more flexible glycemic treatment goal of AIC among demented patients, with a target range between 8 and 9%.
Resumo:
BACKGROUND AND PURPOSE: Patients with symptoms of semicircular canal dehiscence often undergo both CT and MR imaging. We assessed whether FIESTA can replace temporal bone CT in evaluating patients for SC dehiscence. MATERIALS AND METHODS: We retrospectively reviewed 112 consecutive patients (224 ears) with vestibulocochlear symptoms who underwent concurrent MR imaging and CT of the temporal bones between 2007 and 2009. MR imaging protocol included a FIESTA sequence covering the temporal bone (axial 0.8-mm section thickness, 0.4-mm spacing, coronal/oblique reformations; 41 patients at 1.5T, 71 patients at 3T). CT was performed on a 64-row multidetector row scanner (0.625-mm axial acquisition, with coronal/oblique reformations). Both ears of each patient were evaluated for dehiscence of the superior and posterior semicircular canals in consensual fashion by 2 neuroradiologists. Analysis of the FIESTA sequence and reformations was performed first for the MR imaging evaluation. CT evaluation was performed at least 2 weeks after the MR imaging review, resulting in a blinded comparison of CT with MR imaging. CT was used as the reference standard to evaluate the MR imaging results. RESULTS: For SSC dehiscence, MR imaging sensitivity was 100%, specificity was 96.5%, positive predictive value was 61.1%, and negative predictive value was 100% in comparison with CT. For PSC dehiscence, MR imaging sensitivity was 100%, specificity was 99.1%, positive predictive value was 33.3%, and negative predictive value was 100% in comparison with CT. CONCLUSIONS: MR imaging, with a sensitivity and negative predictive value of 100%, conclusively excludes SSC or PSC dehiscence. Negative findings on MR imaging preclude the need for CT to detect SC dehiscence. Only patients with positive findings on MR imaging should undergo CT evaluation.
Resumo:
PURPOSE: To evaluate the technical quality and the diagnostic performance of a protocol with use of low volumes of contrast medium (25 mL) at 64-detector spiral computed tomography (CT) in the diagnosis and management of adult, nontraumatic subarachnoid hemorrhage (SAH). MATERIALS AND METHODS: This study was performed outside the United States and was approved by the institutional review board. Intracranial CT angiography was performed in 73 consecutive patients with nontraumatic SAH diagnosed at nonenhanced CT. Image quality was evaluated by two observers using two criteria: degree of arterial enhancement and venous contamination. The two independent readers evaluated diagnostic performance (lesion detection and correct therapeutic decision-making process) by using rotational angiographic findings as the standard of reference. Sensitivity, specificity, and positive and negative predictive values were calculated for patients who underwent CT angiography and three-dimensional rotational angiography. The intraclass correlation coefficient was calculated to assess interobserver concordance concerning aneurysm measurements and therapeutic management. RESULTS: All aneurysms were detected, either ruptured or unruptured. Arterial opacification was excellent in 62 cases (85%), and venous contamination was absent or minor in 61 cases (84%). In 95% of cases, CT angiographic findings allowed optimal therapeutic management. The intraclass correlation coefficient ranged between 0.93 and 0.95, indicating excellent interobserver agreement. CONCLUSION: With only 25 mL of iodinated contrast medium focused on the arterial phase, 64-detector CT angiography allowed satisfactory diagnostic and therapeutic management of nontraumatic SAH.
Resumo:
Our goal was to evaluate the diagnostic utility of C-reactive protein (CRP) alone or combined with clinical probability assessment in patients with suspected pulmonary embolism (PE), and to compare its performance to a D-dimer assay. We conducted a prospective study in which we performed a common immuno-turbidimetric CRP test and a rapid enzyme-linked immunosorbent assay (ELISA) D-dimer test in 259 consecutive outpatients with suspected PE at the emergency department of a teaching hospital. We assessed clinical probability of PE by a validated prediction rule overridden by clinical judgment. Patients with D-dimer levels > or = 500 microg/l underwent a work-up consisting of lower-limb venous ultrasound, spiral computerized tomography, ventilation-perfusion scan, or pulmonary angiography. Patients were followed up for three months. Seventy-seven (30%) of the patients had PE. The CRP alone had a sensitivity of 84% (95% confidence interval [CI).: 74 to 92%) and a negative predictive value (NPV) of 87% (95% CI: 78 to 93%) at a cutpoint of 5 mg/l. Overall, 61 (24%) patients with a low clinical probability of PE had a CRP < 5 mg/l. Due to the low prevalence of PE (9%) in this subgroup, the NPV increased to 97% (95% CI: 89 to 100%). The D-dimer (cutpoint 500 micro g/l) showed a sensitivity of 100% (95% CI: 95 to 100%) and a NPV of 100% (95% CI: 94 to 100%) irrespective of clinical probability and accurately rule out PE in 56 (22%) patients. Standard CRP tests alone or combined with clinical probability assessment cannot safely exclude PE.
Resumo:
BACKGROUND: Liver remnant volumes after major hepatic resection and graft volumes for liver transplantation correlate with surgical outcome. The relative contributions of the hepatic segments to total liver volume (TLV) are not well established. METHODS: TLV and hepatic segment volumes were measured with computed tomography (CT) in 102 patients without liver disease who underwent CT for conditions unrelated to the liver or biliary tree. RESULTS: TLV ranged from 911 to 2729 cm(3). On average, the right liver (segments V, VI, VII, and VIII) contributed approximately two thirds of TLV (997+/-279 cm(3)), and the left liver (segments II, III and IV) contributed approximately one third of TLV (493+/-127 cm(3)). Bisegment II+III (left lateral section) contributed about half the volume of the left liver (242+/-79 cm(3)), or 16% of TLV. Liver volumes varied significantly between patients--the right liver varied from 49% to 82% of TLV, the left liver, 17% to 49% of TLV, and bisegment II+III (left lateral section) 5% to 27% of TLV. Bisegment II+III contributed less than 20% of TLV in more than 75% of patients and the left liver contributed 25% or less of TLV in more than 10% of patients. DISCUSSION: There is clinically significant interpatient variation in hepatic volumes. Therefore, in the absence of appreciable hypertrophy, we recommend routine measurement of the future liver remnant before extended right hepatectomy (right trisectionectomy) and in selected patients before right hepatectomy if a small left liver is anticipated.