889 resultados para shape vs use
Resumo:
Background Among patients with acute ischemic stroke due to occlusions in the proximal anterior intracranial circulation, less than 40% regain functional independence when treated with intravenous tissue plasminogen activator (t-PA) alone. Thrombectomy with the use of a stent retriever, in addition to intravenous t-PA, increases reperfusion rates and may improve long-term functional outcome. Methods We randomly assigned eligible patients with stroke who were receiving or had received intravenous t-PA to continue with t-PA alone (control group) or to undergo endovascular thrombectomy with the use of a stent retriever within 6 hours after symptom onset (intervention group). Patients had confirmed occlusions in the proximal anterior intracranial circulation and an absence of large ischemic-core lesions. The primary outcome was the severity of global disability at 90 days, as assessed by means of the modified Rankin scale (with scores ranging from 0 [no symptoms] to 6 [death]). Results The study was stopped early because of efficacy. At 39 centers, 196 patients underwent randomization (98 patients in each group). In the intervention group, the median time from qualifying imaging to groin puncture was 57 minutes, and the rate of substantial reperfusion at the end of the procedure was 88%. Thrombectomy with the stent retriever plus intravenous t-PA reduced disability at 90 days over the entire range of scores on the modified Rankin scale (P<0.001). The rate of functional independence (modified Rankin scale score, 0 to 2) was higher in the intervention group than in the control group (60% vs. 35%, P<0.001). There were no significant between-group differences in 90-day mortality (9% vs. 12%, P=0.50) or symptomatic intracranial hemorrhage (0% vs. 3%, P=0.12). Conclusions In patients receiving intravenous t-PA for acute ischemic stroke due to occlusions in the proximal anterior intracranial circulation, thrombectomy with a stent retriever within 6 hours after onset improved functional outcomes at 90 days.
Resumo:
BACKGROUND Guidelines recommend that health care personnel (HCP) wear gloves for all interactions with patients on contact precautions. We aimed to assess hand hygiene (HH) compliance during contact precautions before and after eliminating mandatory glove use. METHODS We assessed HH compliance of HCP in the care of patients on contact precautions in 50 series before (2009) and 6 months after (2012) eliminating mandatory glove use and compared these results with the hospital-wide HH compliance. RESULTS We assessed 426 HH indications before and 492 indications after the policy change. Compared with 2009, we observed a significantly higher HH compliance in patients on contact precautions in 2012 (52%; 95% confidence interval [95% CI], 47-57) vs 85%; 95% CI, 82-88; P < .001). During the same period, hospital-wide HH compliance also increased from 63% (95% CI, 61-65) to 81% (95% CI 80-83) (P < .001). However, the relative improvement (RI) of HH compliance during contact precautions was significantly higher than the hospital-wide relative improvement (RI, 1.6; 95% CI, 1.49-1.81 vs 1.29; 95% CI, 1.25-1.34), with a relative improvement ratio of 1.27 (95% CI, 1.15-1.41). CONCLUSION Eliminating mandatory glove use in the care of patients on contact precautions increased HH compliance in our institution, particularly before invasive procedures and before patient contacts. Further studies on the effect on pathogen transmission are needed before revisiting the current official guidelines on the topic.
Resumo:
BACKGROUND The purpose of this clinical study was to assess the prevalence of acidic oral mucosal lesions and periodontal conditions in patients suffering from erosive esophageal reflux disease (ERD) compared with non erosive esophageal reflux disease (NERD) patients, both treated with long term proton pump inhibitors (PPI). METHODS Seventy-one patients with diagnosed GERD were studied: i.e. 29 ERD and 42 NERD patients. Thorough visual examination of the oral mucosa and a periodontal evaluation was performed. The primary outcome was defined as a statistically significant difference, between the two groups, in the presence of acidic lesions of the oral mucosa and specific periodontal parameters. RESULTS This study failed to demonstrate statistically significant differences between ERD and NERD patients with respect to the prevalence of oral mucosal lesions. However, significantly more ERD patients suffered from severe periodontitis (CAL ≥ 5 mm) as compared to NERD patients. Accordingly, it may be assumed that PPI-use had no adverse effects on the prevalence of acidic oral mucosal lesions and on periodontal destruction. CONCLUSIONS Within the limitations of this study it may be concluded that ERD and NERD patients need separate evaluation with respect to periodontal destruction. Moreover, long term PPI medication had no adverse clinical impact on acidic oral mucosal lesions and periodontal destruction. Further studies are necessary to elucidate the role of reflux in the periodontal destruction of ERD individuals.
Resumo:
AIMS Patients with ST-segment elevation myocardial infarction (STEMI) feature thrombus-rich lesions with large necrotic core, which are usually associated with delayed arterial healing and impaired stent-related outcomes. The use of bioresorbable vascular scaffolds (Absorb) has the potential to overcome these limitations owing to restoration of native vessel lumen and physiology at long term. The purpose of this randomized trial was to compare the arterial healing response at short term, as a surrogate for safety and efficacy, between the Absorb and the metallic everolimus-eluting stent (EES) in patients with STEMI. METHODS AND RESULTS ABSORB-STEMI TROFI II was a multicentre, single-blind, non-inferiority, randomized controlled trial. Patients with STEMI who underwent primary percutaneous coronary intervention were randomly allocated 1:1 to treatment with the Absorb or EES. The primary endpoint was the 6-month optical frequency domain imaging healing score (HS) based on the presence of uncovered and/or malapposed stent struts and intraluminal filling defects. Main secondary endpoint included the device-oriented composite endpoint (DOCE) according to the Academic Research Consortium definition. Between 06 January 2014 and 21 September 2014, 191 patients (Absorb [n = 95] or EES [n = 96]; mean age 58.6 years old; 17.8% females) were enrolled at eight centres. At 6 months, HS was lower in the Absorb arm when compared with EES arm [1.74 (2.39) vs. 2.80 (4.44); difference (90% CI) -1.06 (-1.96, -0.16); Pnon-inferiority <0.001]. Device-oriented composite endpoint was also comparably low between groups (1.1% Absorb vs. 0% EES). One case of definite subacute stent thrombosis occurred in the Absorb arm (1.1% vs. 0% EES; P = ns). CONCLUSION Stenting of culprit lesions with Absorb in the setting of STEMI resulted in a nearly complete arterial healing which was comparable with that of metallic EES at 6 months. These findings provide the basis for further exploration in clinically oriented outcome trials.
Resumo:
The long-term risk associated with different coronary artery disease (CAD) presentations in women undergoing percutaneous coronary intervention (PCI) with drug-eluting stents (DES) is poorly characterized. We pooled patient-level data for women enrolled in 26 randomized clinical trials. Of 11,577 women included in the pooled database, 10,133 with known clinical presentation received a DES. Of them, 5,760 (57%) had stable angina pectoris (SAP), 3,594 (35%) had unstable angina pectoris (UAP) or non-ST-segment-elevation myocardial infarction (NSTEMI), and 779 (8%) had ST-segment-elevation myocardial infarction (STEMI) as clinical presentation. A stepwise increase in 3-year crude cumulative mortality was observed in the transition from SAP to STEMI (4.9% vs 6.1% vs 9.4%; p <0.01). Conversely, no differences in crude mortality rates were observed between 1 and 3 years across clinical presentations. After multivariable adjustment, STEMI was independently associated with greater risk of 3-year mortality (hazard ratio [HR] 3.45; 95% confidence interval [CI] 1.99 to 5.98; p <0.01), whereas no differences were observed between UAP or NSTEMI and SAP (HR 0.99; 95% CI 0.73 to 1.34; p = 0.94). In women with ACS, use of new-generation DES was associated with reduced risk of major adverse cardiac events (HR 0.58; 95% CI 0.34 to 0.98). The magnitude and direction of the effect with new-generation DES was uniform between women with or without ACS (pinteraction = 0.66). In conclusion, in women across the clinical spectrum of CAD, STEMI was associated with a greater risk of long-term mortality. Conversely, the adjusted risk of mortality between UAP or NSTEMI and SAP was similar. New-generation DESs provide improved long-term clinical outcomes irrespective of the clinical presentation in women.
Resumo:
In the present paper, we describe new robust methods of estimating cell shape and orientation in 3D from sections. The descriptors of 3D cell shape and orientation are based on volume tensors which are used to construct an ellipsoid, the Miles ellipsoid, approximating the average cell shape and orientation in 3D. The estimators of volume tensors are based on observations in several optical planes through sampled cells. This type of geometric sampling design is known as the optical rotator. The statistical behaviour of the estimator of the Miles ellipsoid is studied under a flexible model for 3D cell shape and orientation. In a simulation study, the lengths of the axes of the Miles ellipsoid can be estimated with CVs of about 2% if 100 cells are sampled. Finally, we illustrate the use of the developed methods in an example, involving neurons in the medial prefrontal cortex of rat.
Resumo:
BACKGROUND AND AIMS Smoking is a crucial environmental factor in inflammatory bowel disease [IBD]. However, knowledge on patient characteristics associated with smoking, time trends of smoking rates, gender differences and supportive measures to cease smoking provided by physicians is scarce. We aimed to address these questions in Swiss IBD patients. METHODS Prospectively obtained data from patients participating in the Swiss IBD Cohort Study was analysed and compared with the general Swiss population [GSP] matched by age, sex and year. RESULTS Among a total of 1770 IBD patients analysed [49.1% male], 29% are current smokers. More than twice as many patients with Crohn's disease [CD] are active smokers compared with ulcerative colitis [UC] [UC, 39.6% vs CD 15.3%, p < 0.001]. In striking contrast to the GSP, significantly more women than men with CD smoke [42.8% vs 35.8%, p = 0.025], with also an overall significantly increased smoking rate compared with the GSP in women but not men. The vast majority of smoking IBD patients [90.5%] claim to never have received any support to achieve smoking cessation, significantly more in UC compared with CD. We identify a significantly negative association of smoking and primary sclerosing cholangitis, indicative of a protective effect. Psychological distress in CD is significantly higher in smokers compared with non-smokers, but does not differ in UC. CONCLUSIONS Despite well-established detrimental effects, smoking rates in CD are alarmingly high with persistent and stagnating elevations compared with the GSP, especially in female patients. Importantly, there appears to be an unacceptable underuse of supportive measures to achieve smoking cessation.
Resumo:
BACKGROUND Prior epidemiologic studies suggest inverse relations between diabetes and glioma risk, but the underlying mechanisms, including use of antidiabetic drugs, are unknown. METHODS We therefore performed a matched case-control analysis using the Clinical Practice Research Datalink (CPRD). We identified incident glioma cases diagnosed between 1995 and 2012 and matched each case with 10 controls on age, gender, calendar time, general practice, and years of active history in the CPRD. We performed conditional logistic regression to estimate odds ratios (ORs) with 95% CIs, adjusted for body mass index and smoking. RESULTS We identified 2005 cases and 20 050 controls. Diabetes was associated with decreased risk of glioma (OR = 0.74; 95% CI = 0.60-0.93), particularly glioblastoma (OR = 0.69; 95% CI = 0.51-0.94). Glioblastoma risk reduction was markedly pronounced among diabetic men (OR = 0.60; 95% CI = 0.40-0.90), most apparently for those with diabetes of long-term duration (OR for >5 vs 0 y = 0.46; 95% CI = 0.26-0.82) or poor glycemic control (OR for HbA1c ≥8 vs <6.5% = 0.20; 95% CI = 0.06-0.70). In contrast, the effect of diabetes on glioblastoma risk was absent among women (OR = 0.85; 95% CI = 0.53-1.36). No significant associations with glioma were found for use of metformin (OR for ≥30 vs 0 prescriptions = 0.72; 95% CI = 0.38-1.39), sulfonylureas (OR = 0.71; 95% CI = 0.39-1.30), or insulin (OR = 0.79; 95% CI = 0.37-1.69). CONCLUSIONS Antidiabetic treatment appears to be unrelated to glioma, but long-term diabetes duration and increased HbA1c both show decreased glioma risk. Stronger findings in men than women suggest low androgen levels concurrent with diabetes as a biologic mechanism.
Resumo:
We analyzed more than 200 OSIRIS NAC images with a pixel scale of 0.9-2.4 m/pixel of comet 67P/Churyumov-Gerasimenko (67P) that have been acquired from onboard the Rosetta spacecraft in August and September 2014 using stereo-photogrammetric methods (SPG). We derived improved spacecraft position and pointing data for the OSIRIS images and a high-resolution shape model that consists of about 16 million facets (2 m horizontal sampling) and a typical vertical accuracy at the decimeter scale. From this model, we derive a volume for the northern hemisphere of 9.35 km(3) +/- 0.1 km(3). With the assumption of a homogeneous density distribution and taking into account the current uncertainty of the position of the comet's center-of-mass, we extrapolated this value to an overall volume of 18.7 km(3) +/- 1.2 km(3), and, with a current best estimate of 1.0 X 10(13) kg for the mass, we derive a bulk density of 535 kg/m(3) +/- 35 kg/m(3). Furthermore, we used SPG methods to analyze the rotational elements of 67P. The rotational period for August and September 2014 was determined to be 12.4041 +/- 0.0004 h. For the orientation of the rotational axis (z-axis of the body-fixed reference frame) we derived a precession model with a half-cone angle of 0.14 degrees, a cone center position at 69.54 degrees/64.11 degrees (RA/Dec J2000 equatorial coordinates), and a precession period of 10.7 days. For the definition of zero longitude (x-axis orientation), we finally selected the boulder-like Cheops feature on the big lobe of 67P and fixed its spherical coordinates to 142.35 degrees right-hand-rule eastern longitude and -0.28 degrees latitude. This completes the definition of the new Cheops reference frame for 67P. Finally, we defined cartographic mapping standards for common use and combined analyses of scientific results that have been obtained not only within the OSIRIS team, but also within other groups of the Rosetta mission.
Resumo:
All previous studies comparing online and face-to-face format for instruction of economics compared courses that were either online or face-to-face format and regressed exam scores on selected student characteristics. This approach is subject to the econometric problems of self-selection omitted unobserved variables. Our study uses two methods to deal with these problems. First we eliminate self-selection bias by using students from a course that uses both instruction formats. Second, we use the exam questions as the unit of observation, and eliminate omitted variable bias by using an indicator variable for each student to capture the effect of differences in unobserved student characteristics on learning outcomes. We report the finding that students had a significantly greater chance of answering a question correctly if it came from a chapter covered online.
Resumo:
It has been hypothesized that results from the short term bioassays will ultimately provide information that will be useful for human health hazard assessment. Although toxicologic test systems have become increasingly refined, to date, no investigator has been able to provide qualitative or quantitative methods which would support the use of short term tests in this capacity.^ Historically, the validity of the short term tests have been assessed using the framework of the epidemiologic/medical screens. In this context, the results of the carcinogen (long term) bioassay is generally used as the standard. However, this approach is widely recognized as being biased and, because it employs qualitative data, cannot be used in the setting of priorities. In contrast, the goal of this research was to address the problem of evaluating the utility of the short term tests for hazard assessment using an alternative method of investigation.^ Chemical carcinogens were selected from the list of carcinogens published by the International Agency for Research on Carcinogens (IARC). Tumorigenicity and mutagenicity data on fifty-two chemicals were obtained from the Registry of Toxic Effects of Chemical Substances (RTECS) and were analyzed using a relative potency approach. The relative potency framework allows for the standardization of data "relative" to a reference compound. To avoid any bias associated with the choice of the reference compound, fourteen different compounds were used.^ The data were evaluated in a format which allowed for a comparison of the ranking of the mutagenic relative potencies of the compounds (as estimated using short term data) vs. the ranking of the tumorigenic relative potencies (as estimated from the chronic bioassays). The results were statistically significant (p $<$.05) for data standardized to thirteen of the fourteen reference compounds. Although this was a preliminary investigation, it offers evidence that the short term test systems may be of utility in ranking the hazards represented by chemicals which may be human carcinogens. ^
Resumo:
The purpose of this study was to evaluate the adequacy of computerized vital records in Texas for conducting etiologic studies on neural tube defects (NTDs), using the revised and expanded National Centers for Health Statistics vital record forms introduced in Texas in 1989.^ Cases of NTDs (anencephaly and spina bifida) among Harris County (Houston) residents were identified from the computerized birth and death records for 1989-1991. The validity of the system was then measured against cases ascertained independently through medical records and death certificates. The computerized system performed poorly in its identification of NTDs, particularly for anencephaly, where the false positive rate was 80% with little or no improvement over the 3-year period. For both NTDs the sensitivity and predictive value positive of the tapes were somewhat higher for Hispanic than non-Hispanic mothers.^ Case control studies were conducted utilizing the tape set and the independently verified data set, using controls selected from the live birth tapes. Findings varied widely between the data sets. For example, the anencephaly odds ratio for Hispanic mothers (vs. non-Hispanic) was 1.91 (CI = 1.38-2.65) for the tape file, but 3.18 (CI = 1.81-5.58) for verified records. The odds ratio for diabetes was elevated for the tape set (OR = 3.33, CI = 1.67-6.66) but not for verified cases (OR = 1.09, CI = 0.24-4.96), among whom few mothers were diabetic. It was concluded that computerized tapes should not be solely relied on for NTD studies.^ Using the verified cases, Hispanic mother was associated with spina bifida, and Hispanic mother, teen mother, and previous pregnancy terminations were associated with anencephaly. Mother's birthplace, education, parity, and diabetes were not significant for either NTD.^ Stratified analyses revealed several notable examples of statistical interaction. For anencephaly, strong interaction was observed between Hispanic origin and trimester of first prenatal care.^ The prevalence was 3.8 per 10,000 live births for anencephaly and 2.0 for spina bifida (5.8 per 10,000 births for the combined categories). ^
Resumo:
This article presents a comparison of sediment input by rivers and by coastal erosion into both the Laptev Sea and the Canadian Beaufort Sea (CBS). New data on coastal erosion in the Laptev Sea, which are based on field measurements and remote sensing information, and existing data on coastal erosion in the CBS as well as riverine sediment discharge into both the Laptev Sea and the CBS are included. Strong regional differences in the percentages of coastal erosion and riverine sediment supply are observed. The CBS is dominated by the riverine sediment discharge (64.45210**6 t/a) mainly of the Mackenzie River, which is the largest single source of sediments in the Arctic. Riverine sediment discharge into the Laptev Sea amounts to 24.10210**6 t/a, more than 70% of which are related to the Lena River. In comparison with the CBS, the Laptev Sea coast on average delivers approximately twice as much sediment mass per kilometer, a result of higher erosion rates due to higher cliffs and seasonal ice melting. In the Laptev Sea sediment input by coastal erosion (58.4210**6 t/a) is therefore more important than in the CBS and the ratio between riverine and coastal sediment input amounts to 0.4. Coastal erosion supplying 5.6210**6 t/a is less significant for the sediment budget of the CBS where riverine sediment discharge exceeds coastal sediment input by a factor of ca. 10.
Resumo:
A device and a specific procedure for simultaneous concentration of trace ele¬ments from sea water by co-precipitating them in precipitate of magnesium hydroxide obtained by electrolytic alkalization of samples in a two-chamber electrolyzer are described. Analyses of sea water samples for zinc, iron, copper, nickel and lead demonstrate that the method produces a thousand-fold concentration and gives results that agree well with those obtained by extractive concentration using diethyldithiocarbamate and 8-hydroxyquinoline in chloroform. Extracts were analyzed by flame atomic absorption. Correlation coefficients of results obtained with use of these two methods of concentration were 0.76-0.87 for zinc, iron, and copper at confidence levels of 0.05-0.07. Average zinc and iron concentrations determined by the method differed by less than 10%.