917 resultados para perylene carboximides, polyphenylene dendrimers, light harvesting systems, single molecule spectroscopy, single photon sources, molecular wire
Resumo:
Three different forms of PS I complexes were isolated from a siphonous marine green alga, Codium fragile, by Triton X-100 sucrose gradient centrifugation. Zone III had a Chl a/b>20, and designated as PS I. core complex CC I because it created only CP I band in mild PAGE. Zone IV and V had absorption at 436 and 674 nm, 467 and 650 nm, and 540 nm, suggesting the presence of Chl a, Chl b, siphonaxanthin and siphonein, Chl a/b were 3.23 and 2.4, respectively. Both CP I and CP I a bands were observed when they were subjected to mild PAGE. Therefore, Zone IV and V were different forms of PS I complexes that consisted of CC I and different amount of light-harvesting complex LHC I. Zone III contained only 66 and 56 ku peptides in SDS-PAGE, while Zone IV and V had 4 different LHC I peptides of 25, 26, 26.2 and 27.5 ku in addition to 66, 56 ku peptides. Fluorescence emission spectra showed that efficient energy transfer were kept among pigments in isolated PS I complexes. Excitation energy absorbed by Chl b, siphonaxanthin and siphonein can be transferred to Chl a.
Resumo:
By mild PAGE method, 11, 11, 7 and 9 chlorophyll-protein complexes were isolated from two species of siphonous green algae ( Codium fragile (Sur.) Harlot and Bryopsis corticulans Setch.), green alga (Ulothrix flacca (Dillw.) Thur.), and spinach (Spinacia oleracea Mill.), respectively. Apparent molecular weights, Chi a/b ratios, distribution of chlorophyll, absorption spectra, low temperature fluorescence spectra of these complexes were determined, and compared with one another. PS I complexes of two siphonous green algae are larger in apparent molecular weight because of the attachment of relative highly aggregated LHC I. Four isolated light-harvesting complexes of PSII are all siphonaxanthin-Chl a/b-protein complexes, and they are not monomers and oligomers like those in higher plants. Especially, the absence of 730 nn fluorescence in PS I complexes indicates a distinct structure and energy transfer pattern.
Resumo:
PS I, PS II and light-harvesting complexes (LHC) in oxygen evolving photosynthetic organisms were reviewed. These organisms include cyanobacteria, red algae, brown algae, diatoms, chrysophytes, dinophytes, xanthophytes, crypophytes, green algae and green plants. The diversity of pigment-protein complexes that fuel the conversion of radiant energy to chemical bond energy was highlighted, and the evolutionary relationships among the LHC structural polypeptides and the characteristics of the fluorescence emission of PS I at 77 K was discussed.
Resumo:
In order to investigate the possible effects of the ecological environment on photosynthetic activity and the major light harvesting complex, the oxygen evolution rates and composition of phycobilisome from marine red alga Porphyra yezoensis Ueda and freshwater red alga Compsopogon coeruleus (Balbis) Montagne, which could grow and reproduce under salinity up to 35 ppt, were studied. The results showed that the oxygen evolution rate of P. yezoensis in seawater was significantly higher than that of C. coeruleus in freshwater, and P. yezoensis tolerated inorganic ions at a relatively higher concentration than C. coeruleus. Moreover, the phycoerythrin (PE) of P yezoensis was R-phycoerythrin containing alpha, beta, and gamma subunits comprised phycoerythrobilin and phycourobilin. In contrast, the PE from C. coeruleus consisted of alpha, beta, and gamma subunits comprised only phycoerythrobilin but not phycourobilin, suggesting that the PE from C. coeruleus was of a new type.
Resumo:
Allophycocyanin (APC), a cyanobacterial photosynthetic phycobiliprotein, functions in energy transfer as a light-harvesting protein. One of the prominent spectroscopic characteristics of APC is a strong red-shift in the absorption and emission maxima when monomers are assembled into a trimer. Previously, holo-APC alpha and beta subunits (holo-ApcA and ApcB) were successfully synthesized in Escherichia coli. In this study, both holo-subunits from Synechocystis sp. PCC 6803 were co-expressed in E. coli, and found to self-assemble into trimers. The recombinant APC trimer was purified by metal affinity and size-exclusion chromatography, and had a native structure identical to native APC, as determined by characteristic spectroscopic measurements, fluorescence quantum yield, tryptic digestion analysis, and molecular weight measurements. Combined with results from a study in which only the monomer was formed, our results indicate that bilin synthesis and the subsequent attachment to apo-subunits are important for the successful assembly of APC trimers. This is the first study to report on the assembly of recombinant ApcA and ApcB into a trimer with native structure. Our study provides a promising method for producing better fluorescent tags, as well as a method to facilitate the genetic analysis of APC trimer assembly and biological function.
Resumo:
A Chlamydomonas reinhardtii (C. reinhardtii) chloroplast expression vector, papc-B, containing the apc-B gene that encodes the beta subunit of the light-harvesting antenna protein allophycocyanin (APC) of cyanobacteria, was constructed and transferred to the chloroplast genome of C. reinhardtii by the biolistic method. The transformants were identified by Southern blot, Western blot and ELISA assays after selection on resistant medium. The recombinant APC beta subunit was expressed in the C. reinhardtii chloroplast and accounted for up to 2-3% (w/w) of the total soluble protein (TSP), suggesting a promising prospect of using C. reinhardtii chloroplasts to produce functional plant-derived proteins.
Resumo:
Phycobiliproteins, together with linker polypeptides and various chromophores, are basic building blocks of phycobilisomes, a supramolecular complex with a light-harvesting function in cyanobacteria and red algae. Previous studies suggest that the different types of phycobiliproteins and the linker polypeptides originated from the same ancestor. Here we retrieve the phycobilisome-related genes from the well-annotated and even unfinished cyanobacteria genomes and find that many sites with elevated d(N)/d(S) ratios in different phycobiliprotein lineages are located in the chromophore-binding domain and the helical hairpin domains (X and Y). Covariation analyses also reveal that these sites are significantly correlated, showing strong evidence of the functional-structural importance of interactions among these residues. The potential selective pressure driving the diversification of phycobiliproteins may be related to the phycobiliprotein-chromophore microenvironment formation and the subunits interaction. Sites and genes identified here would provide targets for further research on the structural-functional role of these residues and energy transfer through the chromophores.
Resumo:
本研究分为三个部分:1.以坛紫菜(Porphyra haitanesis Chang et Zheng)的叶状体和丝状体为研究对象,比较坛紫菜叶状体和丝状体的光合色素、色素蛋白的组成,并提取纯化藻红蛋白、藻蓝蛋白、藻胆体及类囊体膜和光系统。研究结果表明坛紫菜叶状体和丝状体色素及色素蛋白的含量不同,藻红蛋白是主要的色素蛋白,坛紫菜叶状体和丝状体的藻红蛋白的含量分别为2.9mg藻红蛋白/g鲜重、4.2mg藻红蛋白/g鲜重,这表明坛紫菜叶状体和丝状体藻红蛋白含量丰富,是提取藻红蛋白很好的材料。藻胆体的性质差异不大,但类囊体膜差异显著,从坛紫菜叶状体中分离到了两种不同的类囊体膜带,光系统Ⅰ(PSⅠ)和PSⅡ分别结合在两条类囊体膜带上,但从坛紫菜丝状体中也分离到两条类囊体膜带,它们的光谱性质和蛋白组成相似,仅放氧速率和DCIP活性有差异,从坛紫菜丝状体中我们仅分离到PSⅡ。坛紫菜叶状体PSⅡ有5种外在蛋白(33、20、Cytc 550、15、12kDa蛋白),而坛紫菜丝状体外在蛋白仅有4条,缺少12kDa蛋白。2. 以在中国江苏部分地区进行了大规模的商业化栽培的突变体条斑紫菜(Porphyra yezoensis Ueda)和野生型条斑紫菜为研究对象,比较其色素及色素蛋白组成、对不能光质的利用率及藻胆体的组成。条斑紫菜和突变型条斑紫菜对不同的光质利用效果有差异,在白光的照射下,野生型紫菜的放氧速率最大,而突变型紫菜在黄光照射下的放氧速率最大。条斑紫菜野生型与突变型色素含量上有明显的差异,突变型紫菜的藻红蛋白含量明显减少而藻蓝蛋白的含量增加。通过杂交的方法证实诱变所获得条斑紫菜突变体为细胞质突变,但是突变型紫菜却发生了由细胞核编码的γ亚基的缺失,这表明突变型紫菜藻红蛋白含量和性质发生了明显的变化。3. 为了找出淡水红藻-深紫美芒藻(Compsopogon coeruleus (Balbis) Montagne)分布狭窄及生物产量低的原因,本文对深紫美芒藻在不同的盐离子浓度下的放氧速率及藻胆体色素组成和结构上进行研究。结果显示:微量的NaCl(0.1mM)促进深紫美芒藻放氧,而深紫美芒藻在较高的NaCl(1、10mM), NaH2PO4 (0.1、1、10mM)和 NH4NO3(0.1、1、10mM)溶液中却没有检测到氧气的产生。这与深紫美芒藻生长的环境一致即深紫美芒藻生活在低盐浓度、低营养的泉水中。深紫美芒藻的藻胆体是由藻红蛋白、藻蓝蛋白及别藻蓝蛋白组成,上面结合α、β和γ亚基,含有藻红胆素、藻篮胆素,但缺乏缺少藻尿胆素。
Resumo:
本文给出在混合服务方式下 ,轮询服务系统稳定性的通用判定条件 .文中的判定条件不但适用于混合式服务 ,同样适用于单一式服务 ,如穷尽式服务、门限式服务和限定式服务等 .对于没有精确解的轮询服务系统 ,如限定式服务( K≠ 1 ) ,仍然可以利用本文的判定条件来判别系统稳定性 .分析表明 ,以往的轮询服务系统稳定性判定条件均是文中的特例 .
Resumo:
Kingston-Smith, A. H., Merry, R. J., Leemans, D. K., Thomas, Howard, Theodorou, M. K. (2005). Evidence in support of a role for plant-mediated proteolysis in the rumens of grazing animals. British Journal of Nutrition, 93(1), 73-79. Sponsorship: DEFRA / BBSRC RAE2008
Resumo:
Maria Roca, Caron James, Adriana Pruzinsk?, Stefan H?rtensteiner, Howard Thomas and Helen Ougham. Analysis of the chlorophyll catabolism pathway in leaves of an introgression senescence mutant of Lolium temulentum. Phytochemistry, 65 (9), 1231-1238. Sponsorship: BBSRC RAE2008
Resumo:
Zakład Biofizyki Molekularnej, Centrum NanoBioMedyczne UAM
Resumo:
We use an information-theoretic method developed by Neifeld and Lee [J. Opt. Soc. Am. A 25, C31 (2008)] to analyze the performance of a slow-light system. Slow-light is realized in this system via stimulated Brillouin scattering in a 2 km-long, room-temperature, highly nonlinear fiber pumped by a laser whose spectrum is tailored and broadened to 5 GHz. We compute the information throughput (IT), which quantifies the fraction of information transferred from the source to the receiver and the information delay (ID), which quantifies the delay of a data stream at which the information transfer is largest, for a range of experimental parameters. We also measure the eye-opening (EO) and signal-to-noise ratio (SNR) of the transmitted data stream and find that they scale in a similar fashion to the information-theoretic method. Our experimental findings are compared to a model of the slow-light system that accounts for all pertinent noise sources in the system as well as data-pulse distortion due to the filtering effect of the SBS process. The agreement between our observations and the predictions of our model is very good. Furthermore, we compare measurements of the IT for an optimal flattop gain profile and for a Gaussian-shaped gain profile. For a given pump-beam power, we find that the optimal profile gives a 36% larger ID and somewhat higher IT compared to the Gaussian profile. Specifically, the optimal (Gaussian) profile produces a fractional slow-light ID of 0.94 (0.69) and an IT of 0.86 (0.86) at a pump-beam power of 450 mW and a data rate of 2.5 Gbps. Thus, the optimal profile better utilizes the available pump-beam power, which is often a valuable resource in a system design.
Resumo:
On-board image guidance, such as cone-beam CT (CBCT) and kV/MV 2D imaging, is essential in many radiation therapy procedures, such as intensity modulated radiotherapy (IMRT) and stereotactic body radiation therapy (SBRT). These imaging techniques provide predominantly anatomical information for treatment planning and target localization. Recently, studies have shown that treatment planning based on functional and molecular information about the tumor and surrounding tissue could potentially improve the effectiveness of radiation therapy. However, current on-board imaging systems are limited in their functional and molecular imaging capability. Single Photon Emission Computed Tomography (SPECT) is a candidate to achieve on-board functional and molecular imaging. Traditional SPECT systems typically take 20 minutes or more for a scan, which is too long for on-board imaging. A robotic multi-pinhole SPECT system was proposed in this dissertation to provide shorter imaging time by using a robotic arm to maneuver the multi-pinhole SPECT system around the patient in position for radiation therapy.
A 49-pinhole collimated SPECT detector and its shielding were designed and simulated in this work using the computer-aided design (CAD) software. The trajectories of robotic arm about the patient, treatment table and gantry in the radiation therapy room and several detector assemblies such as parallel holes, single pinhole and 49 pinholes collimated detector were investigated. The rail mounted system was designed to enable a full range of detector positions and orientations to various crucial treatment sites including head and torso, while avoiding collision with linear accelerator (LINAC), patient table and patient.
An alignment method was developed in this work to calibrate the on-board robotic SPECT to the LINAC coordinate frame and to the coordinate frames of other on-board imaging systems such as CBCT. This alignment method utilizes line sources and one pinhole projection of these line sources. The model consists of multiple alignment parameters which maps line sources in 3-dimensional (3D) space to their 2-dimensional (2D) projections on the SPECT detector. Computer-simulation studies and experimental evaluations were performed as a function of number of line sources, Radon transform accuracy, finite line-source width, intrinsic camera resolution, Poisson noise and acquisition geometry. In computer-simulation studies, when there was no error in determining angles (α) and offsets (ρ) of the measured projections, the six alignment parameters (3 translational and 3 rotational) were estimated perfectly using three line sources. When angles (α) and offsets (ρ) were provided by Radon transform, the estimation accuracy was reduced. The estimation error was associated with rounding errors of Radon transform, finite line-source width, Poisson noise, number of line sources, intrinsic camera resolution and detector acquisition geometry. The estimation accuracy was significantly improved by using 4 line sources rather than 3 and also by using thinner line-source projections (obtained by better intrinsic detector resolution). With 5 line sources, median errors were 0.2 mm for the detector translations, 0.7 mm for the detector radius of rotation, and less than 0.5° for detector rotation, tilt and twist. In experimental evaluations, average errors relative to a different, independent registration technique were about 1.8 mm for detector translations, 1.1 mm for the detector radius of rotation (ROR), 0.5° and 0.4° for detector rotation and tilt, respectively, and 1.2° for detector twist.
Simulation studies were performed to investigate the improvement of imaging sensitivity and accuracy of hot sphere localization for breast imaging of patients in prone position. A 3D XCAT phantom was simulated in the prone position with nine hot spheres of 10 mm diameter added in the left breast. A no-treatment-table case and two commercial prone breast boards, 7 and 24 cm thick, were simulated. Different pinhole focal lengths were assessed for root-mean-square-error (RMSE). The pinhole focal lengths resulting in the lowest RMSE values were 12 cm, 18 cm and 21 cm for no table, thin board, and thick board, respectively. In both no table and thin board cases, all 9 hot spheres were easily visualized above background with 4-minute scans utilizing the 49-pinhole SPECT system while seven of nine hot spheres were visible with the thick board. In comparison with parallel-hole system, our 49-pinhole system shows reduction in noise and bias under these simulation cases. These results correspond to smaller radii of rotation for no-table case and thinner prone board. Similarly, localization accuracy with the 49-pinhole system was significantly better than with the parallel-hole system for both the thin and thick prone boards. Median localization errors for the 49-pinhole system with the thin board were less than 3 mm for 5 of 9 hot spheres, and less than 6 mm for the other 4 hot spheres. Median localization errors of 49-pinhole system with the thick board were less than 4 mm for 5 of 9 hot spheres, and less than 8 mm for the other 4 hot spheres.
Besides prone breast imaging, respiratory-gated region-of-interest (ROI) imaging of lung tumor was also investigated. A simulation study was conducted on the potential of multi-pinhole, region-of-interest (ROI) SPECT to alleviate noise effects associated with respiratory-gated SPECT imaging of the thorax. Two 4D XCAT digital phantoms were constructed, with either a 10 mm or 20 mm diameter tumor added in the right lung. The maximum diaphragm motion was 2 cm (for 10 mm tumor) or 4 cm (for 20 mm tumor) in superior-inferior direction and 1.2 cm in anterior-posterior direction. Projections were simulated with a 4-minute acquisition time (40 seconds per each of 6 gates) using either the ROI SPECT system (49-pinhole) or reference single and dual conventional broad cross-section, parallel-hole collimated SPECT. The SPECT images were reconstructed using OSEM with up to 6 iterations. Images were evaluated as a function of gate by profiles, noise versus bias curves, and a numerical observer performing a forced-choice localization task. Even for the 20 mm tumor, the 49-pinhole imaging ROI was found sufficient to encompass fully usual clinical ranges of diaphragm motion. Averaged over the 6 gates, noise at iteration 6 of 49-pinhole ROI imaging (10.9 µCi/ml) was approximately comparable to noise at iteration 2 of the two dual and single parallel-hole, broad cross-section systems (12.4 µCi/ml and 13.8 µCi/ml, respectively). Corresponding biases were much lower for the 49-pinhole ROI system (3.8 µCi/ml), versus 6.2 µCi/ml and 6.5 µCi/ml for the dual and single parallel-hole systems, respectively. Median localization errors averaged over 6 gates, for the 10 mm and 20 mm tumors respectively, were 1.6 mm and 0.5 mm using the ROI imaging system and 6.6 mm and 2.3 mm using the dual parallel-hole, broad cross-section system. The results demonstrate substantially improved imaging via ROI methods. One important application may be gated imaging of patients in position for radiation therapy.
A robotic SPECT imaging system was constructed utilizing a gamma camera detector (Digirad 2020tc) and a robot (KUKA KR150-L110 robot). An imaging study was performed with a phantom (PET CT Phantom
In conclusion, the proposed on-board robotic SPECT can be aligned to LINAC/CBCT with a single pinhole projection of the line-source phantom. Alignment parameters can be estimated using one pinhole projection of line sources. This alignment method may be important for multi-pinhole SPECT, where relative pinhole alignment may vary during rotation. For single pinhole and multi-pinhole SPECT imaging onboard radiation therapy machines, the method could provide alignment of SPECT coordinates with those of CBCT and the LINAC. In simulation studies of prone breast imaging and respiratory-gated lung imaging, the 49-pinhole detector showed better tumor contrast recovery and localization in a 4-minute scan compared to parallel-hole detector. On-board SPECT could be achieved by a robot maneuvering a SPECT detector about patients in position for radiation therapy on a flat-top couch. The robot inherent coordinate frames could be an effective means to estimate detector pose for use in SPECT image reconstruction.