939 resultados para palladium and platinum particles
Resumo:
Data on zooplankton abundance and biovolume were collected in concert with data on the biophysical environment at 9 stations in the North Atlantic, from the Iceland Basin in the East to the Labrador Sea in the West. The data were sampled along vertical profiles by a Laser Optical Plankton Counter (LOPC, Rolls Royce Canada Ltd.) that was mounted on a carousel water sampler together with a Conductivity-Temperature-Depth sensor (CTD, SBE19plusV2, Seabird Electronics, Inc., USA) and a fluorescence sensor (F, ECO Puck chlorophyll a fluorometer, WET Labs Inc., USA). Based on the LOPC data, abundance (individuals/m**3) and biovolume (mm3/m**3) were calculated as described in the LOPC Software Operation Manual [(Anonymous, 2006), http://www.brooke-ocean.com/index.html]. LOPC data were regrouped into 49 size groups of equal log10(body volume) increments, see Edvardsen et al. (2002, doi:10.3354/meps227205). LOPC data quality was checked as described in Basedow et al. (2013, doi:10.1016/j.pocean.2012.10.005). Fluorescence was roughly converted into chlorophyll based on filtered chlorophyll values obtained from station 10 in the Labrador Sea. Due to the low number of filtered samples that was used for the conversion the resulting chlorophyll values should be considered with care. CTD data were screened for erroneous (out of range) values and then averaged to the same frequency as the LOPC data (2 Hz). All data were processed using especially developed scripts in the python programming language. The LOPC is an optical instrument designed to count and measure particles (0.1 to 30 mm equivalent spherical diameter) in the water column, see Herman et al., (2004, doi:10.1093/plankt/fbh095). The size of particles as equivalent spherical diameter (ESD) was computed as described in the manual (Anonymous, 2006), and in more detail in Checkley et al. (2008, doi:10.4319/lo.2008.53.5_part_2.2123) and Gaardsted et al. (2010, doi:10.1111/j.1365-2419.2010.00558.x).
Resumo:
Data on zooplankton abundance and biovolume were collected in concert with data on the biophysical environment at 9 stations in the North Atlantic, from the Iceland Basin in the East to the Labrador Sea in the West. The data were sampled along vertical profiles by a Laser Optical Plankton Counter (LOPC, Rolls Royce Canada Ltd.) that was mounted on a carousel water sampler together with a Conductivity-Temperature-Depth sensor (CTD, SBE19plusV2, Seabird Electronics, Inc., USA) and a fluorescence sensor (F, ECO Puck chlorophyll a fluorometer, WET Labs Inc., USA). Based on the LOPC data, abundance (individuals/m**3) and biovolume (mm3/m**3) were calculated as described in the LOPC Software Operation Manual [(Anonymous, 2006), http://www.brooke-ocean.com/index.html]. LOPC data were regrouped into 49 size groups of equal log10(body volume) increments, see Edvardsen et al. (2002, doi:10.3354/meps227205). LOPC data quality was checked as described in Basedow et al. (2013, doi:10.1016/j.pocean.2012.10.005). Fluorescence was roughly converted into chlorophyll based on filtered chlorophyll values obtained from station 10 in the Labrador Sea. Due to the low number of filtered samples that was used for the conversion the resulting chlorophyll values should be considered with care. CTD data were screened for erroneous (out of range) values and then averaged to the same frequency as the LOPC data (2 Hz). All data were processed using especially developed scripts in the python programming language. The LOPC is an optical instrument designed to count and measure particles (0.1 to 30 mm equivalent spherical diameter) in the water column, see Herman et al., (2004, doi:10.1093/plankt/fbh095). The size of particles as equivalent spherical diameter (ESD) was computed as described in the manual (Anonymous, 2006), and in more detail in Checkley et al. (2008, doi:10.4319/lo.2008.53.5_part_2.2123) and Gaardsted et al. (2010, doi:10.1111/j.1365-2419.2010.00558.x).
Resumo:
Data on zooplankton abundance and biovolume were collected in concert with data on the biophysical environment at 9 stations in the North Atlantic, from the Iceland Basin in the East to the Labrador Sea in the West. The data were sampled along vertical profiles by a Laser Optical Plankton Counter (LOPC, Rolls Royce Canada Ltd.) that was mounted on a carousel water sampler together with a Conductivity-Temperature-Depth sensor (CTD, SBE19plusV2, Seabird Electronics, Inc., USA) and a fluorescence sensor (F, ECO Puck chlorophyll a fluorometer, WET Labs Inc., USA). Based on the LOPC data, abundance (individuals/m**3) and biovolume (mm3/m**3) were calculated as described in the LOPC Software Operation Manual [(Anonymous, 2006), http://www.brooke-ocean.com/index.html]. LOPC data were regrouped into 49 size groups of equal log10(body volume) increments, see Edvardsen et al. (2002, doi:10.3354/meps227205). LOPC data quality was checked as described in Basedow et al. (2013, doi:10.1016/j.pocean.2012.10.005). Fluorescence was roughly converted into chlorophyll based on filtered chlorophyll values obtained from station 10 in the Labrador Sea. Due to the low number of filtered samples that was used for the conversion the resulting chlorophyll values should be considered with care. CTD data were screened for erroneous (out of range) values and then averaged to the same frequency as the LOPC data (2 Hz). All data were processed using especially developed scripts in the python programming language. The LOPC is an optical instrument designed to count and measure particles (0.1 to 30 mm equivalent spherical diameter) in the water column, see Herman et al., (2004, doi:10.1093/plankt/fbh095). The size of particles as equivalent spherical diameter (ESD) was computed as described in the manual (Anonymous, 2006), and in more detail in Checkley et al. (2008, doi:10.4319/lo.2008.53.5_part_2.2123) and Gaardsted et al. (2010, doi:10.1111/j.1365-2419.2010.00558.x).
Resumo:
Data on zooplankton abundance and biovolume were collected in concert with data on the biophysical environment at 9 stations in the North Atlantic, from the Iceland Basin in the East to the Labrador Sea in the West. The data were sampled along vertical profiles by a Laser Optical Plankton Counter (LOPC, Rolls Royce Canada Ltd.) that was mounted on a carousel water sampler together with a Conductivity-Temperature-Depth sensor (CTD, SBE19plusV2, Seabird Electronics, Inc., USA) and a fluorescence sensor (F, ECO Puck chlorophyll a fluorometer, WET Labs Inc., USA). Based on the LOPC data, abundance (individuals/m**3) and biovolume (mm3/m**3) were calculated as described in the LOPC Software Operation Manual [(Anonymous, 2006), http://www.brooke-ocean.com/index.html]. LOPC data were regrouped into 49 size groups of equal log10(body volume) increments, see Edvardsen et al. (2002, doi:10.3354/meps227205). LOPC data quality was checked as described in Basedow et al. (2013, doi:10.1016/j.pocean.2012.10.005). Fluorescence was roughly converted into chlorophyll based on filtered chlorophyll values obtained from station 10 in the Labrador Sea. Due to the low number of filtered samples that was used for the conversion the resulting chlorophyll values should be considered with care. CTD data were screened for erroneous (out of range) values and then averaged to the same frequency as the LOPC data (2 Hz). All data were processed using especially developed scripts in the python programming language. The LOPC is an optical instrument designed to count and measure particles (0.1 to 30 mm equivalent spherical diameter) in the water column, see Herman et al., (2004, doi:10.1093/plankt/fbh095). The size of particles as equivalent spherical diameter (ESD) was computed as described in the manual (Anonymous, 2006), and in more detail in Checkley et al. (2008, doi:10.4319/lo.2008.53.5_part_2.2123) and Gaardsted et al. (2010, doi:10.1111/j.1365-2419.2010.00558.x).
Resumo:
Data on zooplankton abundance and biovolume were collected in concert with data on the biophysical environment at 9 stations in the North Atlantic, from the Iceland Basin in the East to the Labrador Sea in the West. The data were sampled along vertical profiles by a Laser Optical Plankton Counter (LOPC, Rolls Royce Canada Ltd.) that was mounted on a carousel water sampler together with a Conductivity-Temperature-Depth sensor (CTD, SBE19plusV2, Seabird Electronics, Inc., USA) and a fluorescence sensor (F, ECO Puck chlorophyll a fluorometer, WET Labs Inc., USA). Based on the LOPC data, abundance (individuals/m**3) and biovolume (mm3/m**3) were calculated as described in the LOPC Software Operation Manual [(Anonymous, 2006), http://www.brooke-ocean.com/index.html]. LOPC data were regrouped into 49 size groups of equal log10(body volume) increments, see Edvardsen et al. (2002, doi:10.3354/meps227205). LOPC data quality was checked as described in Basedow et al. (2013, doi:10.1016/j.pocean.2012.10.005). Fluorescence was roughly converted into chlorophyll based on filtered chlorophyll values obtained from station 10 in the Labrador Sea. Due to the low number of filtered samples that was used for the conversion the resulting chlorophyll values should be considered with care. CTD data were screened for erroneous (out of range) values and then averaged to the same frequency as the LOPC data (2 Hz). All data were processed using especially developed scripts in the python programming language. The LOPC is an optical instrument designed to count and measure particles (0.1 to 30 mm equivalent spherical diameter) in the water column, see Herman et al., (2004, doi:10.1093/plankt/fbh095). The size of particles as equivalent spherical diameter (ESD) was computed as described in the manual (Anonymous, 2006), and in more detail in Checkley et al. (2008, doi:10.4319/lo.2008.53.5_part_2.2123) and Gaardsted et al. (2010, doi:10.1111/j.1365-2419.2010.00558.x).
Resumo:
Data on zooplankton abundance and biovolume were collected in concert with data on the biophysical environment at 9 stations in the North Atlantic, from the Iceland Basin in the East to the Labrador Sea in the West. The data were sampled along vertical profiles by a Laser Optical Plankton Counter (LOPC, Rolls Royce Canada Ltd.) that was mounted on a carousel water sampler together with a Conductivity-Temperature-Depth sensor (CTD, SBE19plusV2, Seabird Electronics, Inc., USA) and a fluorescence sensor (F, ECO Puck chlorophyll a fluorometer, WET Labs Inc., USA). Based on the LOPC data, abundance (individuals/m**3) and biovolume (mm3/m**3) were calculated as described in the LOPC Software Operation Manual [(Anonymous, 2006), http://www.brooke-ocean.com/index.html]. LOPC data were regrouped into 49 size groups of equal log10(body volume) increments, see Edvardsen et al. (2002, doi:10.3354/meps227205). LOPC data quality was checked as described in Basedow et al. (2013, doi:10.1016/j.pocean.2012.10.005). Fluorescence was roughly converted into chlorophyll based on filtered chlorophyll values obtained from station 10 in the Labrador Sea. Due to the low number of filtered samples that was used for the conversion the resulting chlorophyll values should be considered with care. CTD data were screened for erroneous (out of range) values and then averaged to the same frequency as the LOPC data (2 Hz). All data were processed using especially developed scripts in the python programming language. The LOPC is an optical instrument designed to count and measure particles (0.1 to 30 mm equivalent spherical diameter) in the water column, see Herman et al., (2004, doi:10.1093/plankt/fbh095). The size of particles as equivalent spherical diameter (ESD) was computed as described in the manual (Anonymous, 2006), and in more detail in Checkley et al. (2008, doi:10.4319/lo.2008.53.5_part_2.2123) and Gaardsted et al. (2010, doi:10.1111/j.1365-2419.2010.00558.x).
Resumo:
As part of the GEOTRACES Polarstern expedition ANT XXIV/3 (ZERO and DRAKE), Polonium-210 and Lead-210 have been measured in the water column and on suspended particulate matter in February to April 2008. Our goal was to resolve the affinities of 210Po and 210Pb to transparent exopolymer particles (TEP) and particulate organic carbon (POC). Polonium-210 and Lead-210 in the ocean can be used to identify the sources and sinks of suspended matter. In seawater, Polonium-210 (210Po) and Lead-210 (210Pb) are produced by stepwise radioactive decay of Uranium-238. 210Po (138 days half life) and 210Pb (22.3 years half life) have high affinities for suspended particles. Those radionuclides are present in dissolved form and adsorbed onto particles. Following adsorption onto particle surfaces, 210Po especially is transported into the interior of cells where it bonds to proteins. In this way, 210Po also accumulates in the food chain. 210Po is therefore considered to be a good tracer for POC, and traces particle export over a timescale of months. 210Pb (22.3 years half life) adsorbs preferably onto structural components of cells, biogenic silica and lithogenic particles, and is therefore a better tracer more rapidly sinking matter. Water samples were taken with Niskin bottles. Dissolved Polonium-210 and Lead-210 activities refer to the fraction < 1µm. Particulate Polonium-210 and Lead-210 refer to the activity on particles >1µm retained on nucleopore filters. Zooplankton retained on the filters was systematically removed as this study focused on phytoplankton and exudates. The data have been submitted to Pangaea following a Polonium-Lead intercalibration exercise organized by GEOTRACES, where the AWI lab results range within the data standard deviation from 10 participating labs.
Resumo:
The first wall armour for the reactor chamber of HiPER will have to face short energy pulses of 5 to 20 MJ mostly in the form of x-rays and charged particles at a repetition rate of 5–10 Hz. Armour material and chamber dimensions have to be chosen to avoid/minimize damage to the chamber, ensuring the proper functioning of the facility during its planned lifetime. The maximum energy fluence that the armour can withstand without risk of failure, is determined by temporal and spatial deposition of the radiation energy inside the material. In this paper, simulations on the thermal effect of the radiation–armour interaction are carried out with an increasing definition of the temporal and spatial deposition of energy to prove their influence on the final results. These calculations will lead us to present the first values of the thermo-mechanical behaviour of the tungsten armour designed for the HiPER project under a shock ignition target of 48 MJ. The results will show that only the crossing of the plasticity limit in the first few micrometres might be a threat after thousands of shots for the survivability of the armour.
Resumo:
One of the most advance designs for HiPER fusion reactor is a spherical chamber 10 m in diameter based on dry wall concept. In this system, the first wall will have to withstand short energy pulses of 5 to 20 MJ at a repetition rate of 0.5-10 Hz mostly in form of X-rays and charged particles. To avoid melting of the inner surface, the first wall consists on a thin armor attached to the structural material. Thickness (th) and material of each layer have to be chosen to assure the proper functioning of the facility during its planned lifetime.
Resumo:
A high resolution focused beam line has been recently installed on the AIFIRA (“Applications Interdisciplinaires des Faisceaux d’Ions en Région Aquitaine”) facility at CENBG. This nanobeam line, based on a doublet–triplet configuration of Oxford Microbeam Ltd. OM-50™ quadrupoles, offers the opportunity to focus protons, deuterons and alpha particles in the MeV energy range to a sub-micrometer beam spot. The beam optics design has been studied in detail and optimized using detailed ray-tracing simulations and the full mechanical design of the beam line was reported in the Debrecen ICNMTA conference in 2008. During the last two years, the lenses have been carefully aligned and the target chamber has been fully equipped with particle and X-ray detectors, microscopes and precise positioning stages. The beam line is now operational and has been used for its firstapplications to ion beam analysis. Interestingly, this set-up turned out to be a very versatile tool for a wide range of applications. Indeed, even if it was not intended during the design phase, the ion optics configuration offers the opportunity to work either with a high current microbeam (using the triplet only) or with a lower current beam presenting a sub-micrometer resolution (using the doublet–triplet configuration). The performances of the CENBGnanobeam line are presented for both configurations. Quantitative data concerning the beam lateral resolutions at different beam currents are provided. Finally, the firstresults obtained for different types of application are shown, including nuclear reaction analysis at the micrometer scale and the firstresults on biological samples
Resumo:
El objetivo de este proyecto de investigación es analizar el conjunto de las diez series temporales, relativas a los precios de diez metales (plata, aluminio, oro, cobre, níquel, paladio, plomo, platino, estaño y zinc), comprendidos en el periodo de enero de 2008 a septiembre de 2013, con el objetivo de reducir la dimensionalidad del conjunto de datos y facilitar la comparación de los mismos y la predicción de valores futuros. Para ello pretendemos aplicar una metodología, que nos permitirá deducir, a partir de una serie resumen y de unos coeficientes multiplicativos, la evolución del comportamiento de cualquier otro metal. Pese a la escasísima documentación existente al respecto, se valorará e intentará aplicarse una reciente metodología denominada “Metodología del haz de rectas” Como herramienta de trabajo para los programas informáticos desarrollados y para representar las gráficas asociadas al proyecto, se utilizó Matlab®, habida cuenta de su enorme potencia y por disponer de un lenguaje de programación sencillo y lo suficientemente versátil para las tareas que necesitamos. Abstract. The objective of this research project is to analyze the set of ten time series on prices of the ten metals (silver, aluminum, gold, copper, nickel, palladium, lead, platinum, tin and zinc), included in the period January 2008 to September 2013, with the aim of reducing the dimensionality of the data set and to facilitate comparison of the data and the prediction of future values To apply this methodology, allowing us to predict, from a series summarizes the evolution of the behavior of any other metal. This methodology is called "straight beam Methodology" As a tool for developing computer software and associated graphs to represent the project, Matlab® was used in view of its enormous power and have a simple programming language and versatile enough for the tasks we need