954 resultados para oxygen uptake slow component


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The current study evaluated equine gas exchange responses through spirometry, by measuring oxygen uptake (VO2), carbon dioxide production (VCO2), respiratory exchange ratio (R) and maximum oxygen uptake (VO2max) of Arabian horses during a standard incremental exercise test performed on a high-speed treadmill. Six clinically healthy Arabian horses were submitted to a standard incremental exercise test, performed on a high-speed treadmill at a 6% slope, and initial speed of 1,8 m.s-1 for 5 minutes, then 4,0 m.s-1 for 3 minutes, 6,0 m.s-1 for 2 minutes and 8,0 m.s-1, 9,0 m.s-1, 10,0 m.s-1 and 11,0 m.s-1 for one minute for each of these speed. The end of the exercise test was defined as the point in which the horse was no longer able to keep pace with the treadmill. Gas exchange was measured through respiratory analyses horse mask on the last 10 seconds at the end of each speed transition and at 1, 2 and 3 minutes after the end of the exercise, defined as experiment moments. During exercise, it was noticed an increase on both VO2 and VCO2 with linear relationship between exercise and speed. Arabian horses VO2max was 114,9 mL.kg-1.min-1. The respiratory exchange ratio increased over 1,0 by the speed of 9,0 m.s-1, indicating the preponderance of the anaerobic metabolism, and remains at a high level on the post-exercise period.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

This study analyzed the effects of overground walking training at ventilatory threshold (VT) velocity on glycaemic control, body composition, physical fitness and lipid profile in DM2 women. Nineteen sedentary patients were randomly assigned to a control group (CG; n=10, 55.9±2.2 years) or a trained group (TG; n=9, 53.4±2.3 years). Both groups were subjected to anthropometric measures, a 12-h fasting blood sampling and a graded treadmill exercise test at baseline and after a 12-week period, during which TG followed a training program involving overground walking at VT velocity for 20-60min/session three times/week. Significant group×time interactions (P<0.05) in glycated hemoglobin (HbA1c), body mass, body mass index (BMI), peak oxygen uptake (VO 2peak) and exercise duration were observed as effects of training exercise, whereas intervention did not induced significant changes (P>0.05) in fasting blood glucose, submaximal fitness parameters and lipid profile. Our results suggest that overground walking training at VT velocity improves long term glycaemic control, body composition and exercise capacity, attesting for the relevance of this parameter as an effective strategy for the exercise intensity prescription in DM2 population. © 2011 Elsevier B.V.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The maximal oxygen uptake (VO2max) is the maximal quantity of energy that can be produced by the aerobic metabolism in certain time unity. It can be determined direct or indirectly by predictive equations. The objective of this study was to make a specific predictive equation to determine the VO 2max from boys aged 10-16 years-old. Forty-two boys underwent a treadmill running ergospirometric test, with the initial velocity set at 9 km/h, until voluntary exhaustion. By the multiple linear regression was possible to develop the following equation for the indirect determination of the VO 2max: VO2max (ml/min) = -1574.06 + (141.38 x Vpeak) + (48.34 * Body mass), with standard error of estimate = 191.5 ml/min (4.10 ml/kg/min) and coefficient of determination = 0.934. We suggest that this formula is appropriate to predict VO2max for this population.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purpose of this study was to investigate whether the critical force (CritF) and anaerobic impulse capacity (AIC) - estimated by tethered swimming - reflect the aerobic and anaerobic performance of swimmers. 12 swimmers performed incremental test in tethered swimming to determine lactate anaerobic threshold (AnTLAC), maximal oxygen uptake (̇VO2MAX) and force associated with the ̇VO2MAX (i ̇VO2MAX). The swimmers performed 4 exhaustive (tlim) exercise bouts (100, 110, 120 and 130% i ̇VO2MAX) to compute the CritF and AIC (F vs. 1/tlim model); a 30-s all-out tethered swimming bout to determine their anaerobic fitness (ANF); 100, 200, and 400-m time-trials to determine the swimming performance. CritF (57.09±11.77 N) did not differ from AnTLAC (53.96±11.52 N, (P>0.05) but was significantly lower than i ̇VO2MAX (71.02±8.36 N). In addition, CritF presented significant correlation with AnTLAC (r=0.76; P<0.05) and i ̇VO2MAX (r=0.74; P<0.05). On the other hand, AIC (286.19±54.91 N.s) and ANF (116.10±13.66 N) were significantly correlated (r=0.81, p<0.05). In addition, CritF and AIC presented significant correlations with all time-trials. In summary, this study demonstrates that CritF and AIC can be used to evaluate AnTLAC and ANF and to predict 100, 200, and 400-m free swimming. © Georg Thieme Verlag KG Stuttgart . New York.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: This study aimed to determine the energy expenditure (EE) in terms of caloric cost and metabolic equivalents (METs) of two sessions of an exercise protocol. Methods: Fifteen subjects (51.0 ± 5.5years) performed the exercise sessions (80min), which were composed by (warming, walking and flexibility exercises; Session A) and (warming, walking and local muscular endurance exercises; Session B). Heart hate (HR) was measured during each part of the sessions. In laboratory environment, maximal oxygen consumption (VO2max) and oxygen uptake in rest and exercise conditions (using mean HR obtained in classes) were measured on different days, using indirect calorimetry. Exercise METs were obtained by dividing VO2 in exercise (mL.kg-1.min-1) by VO2 in rest (mL.kg-1.min-1). The EE of the exercises was calculated by the formula: MET x Weight(kg) x Time(min)/60. The results were analyzed by ANOVA with Tuckey post hoc test (p < 0.05). Results: One MET for this group was 2.7 ± 0.1mL.kg-1.min-1. The mean METs of exercises were 4,7 ± 0,8 (warming), 5,8 ± 0,9 (walking) and 3,6 ± 0,7 (flexibility) on session A, and 4,6 ± 1,2 (warming), 5,6 ± 1,0 (walking) and 4.8 ± 1,0 (local muscular endurance exercises) on Session B. The training sessions showed similar energy cost (A: 398 ± 86.72 kcal and B: 404 ± 38.85 kcal; p > 0,05). None of activities were classified into vigorous intensity (> 7 METs). There were no differences on VO2 between walking (15,6 ± 2,8 or 15,4 ± 2,6 mL.kg-1.min-1) and local muscular endurance exercises (13,2 ± 2,9 mL.kg-1.min-1), although both were higher (p > 0.05) than flexibility exercises (10.1 ± 2.2 mL.kg-1.min-1). Conclusion: The proposed protocol achieves the physical activity needed by healthy adults to improve and maintain health, by their structure, moderate intensity, duration, frequency and caloric expenditure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: Hypertension can be generated by a great number of mechanisms including elevated uric acid (UA) that contribute to the anion superoxide production. However, physical exercise is recommended to prevent and/or control high blood pressure (BP). The purpose of this study was to investigate the relationship between BP and UA and whether this relationship may be mediated by the functional fitness index.Methods: All participants (n = 123) performed the following tests: indirect maximal oxygen uptake (VO2max), AAHPERD Functional Fitness Battery Test to determine the general fitness functional index (GFFI), systolic and diastolic blood pressure (SBP and DBP), body mass index (BMI) and blood sample collection to evaluate the total-cholesterol (CHOL), LDL-cholesterol (LDL-c), HDL-cholesterol (HDL-c), triglycerides (TG), uric acid (UA), nitrite (NO2) and thiobarbituric acid reactive substances (T-BARS). After the physical, hemodynamic and metabolic evaluations, all participants were allocated into three groups according to their GFFI: G1 (regular), G2 (good) and G3 (very good).Results: Baseline blood pressure was higher in G1 when compared to G3 (+12% and +11%, for SBP and DBP, respectively, p<0.05) and the subjects who had higher values of BP also presented higher values of UA. Although UA was not different among GFFI groups, it presented a significant correlation with GFFI and VO2max. Also, nitrite concentration was elevated in G3 compared to G1 (140±29 μM vs 111± 29 μM, for G3 and G1, respectively, p<0.0001). As far as the lipid profile, participants in G3 presented better values of CHOL and TG when compared to those in G1.Conclusions: Taking together the findings that subjects with higher BP had elevated values of UA and lower values of nitrite, it can be suggested that the relationship between blood pressure and the oxidative stress produced by acid uric may be mediated by training status. © 2013 Trapé et al.; licensee BioMed Central Ltd.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

O objetivo deste estudo foi determinar, em mesatenistas bem treinados, as aptidões aeróbia e anaeróbia. Participaram do presente estudo oito mesatenistas brasileiros treinados do sexo masculino (18±2 anos). Os sujeitos foram submetidos a um teste incremental específico para determinação do consumo pico de oxigênio (VO2PICO), intensidade associada ao VO2PICO (iVO2PICO) e do ponto de compensação respiratório (PCR) e a dois testes de esforço repetitivo, sendo o teste de RAST e o índice anaeróbio alático (IAA), para determinação dos índices anaeróbios. O VO2PICO correspondeu a 50,5±4,4ml kg-1 min-1 , a iVO2PICO a 52,1±9,6 bolas min-1 e o PCR a 44,9±8,0 bolas min-1. No RAST, a potência pico (PP) e a potência média (PM) relativa corresponderam a 9,0±1,3W kg-1 e 7,0±0,9W kg-1, respectivamente, enquanto que o IAA foi 1,14±0,51 mM/m s-1 . Esses valores de VO2PICO e dos parâmetros anaeróbios quando comparados a valores de outros esportes com raquetes caracterizaram que mesatenistas brasileiros treinados apresentam potência aeróbia moderada e potência anaeróbia é baixa.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The purposes of this study were to assess the influence of stage selection from the incremental phase and the use of peak lactate after hyperlactatemia induction on the determination of the lactate minimum intensity (iLACmin). Twelve moderately active university students (23±5 years, 78.3±14.1 kg, 175.3±5.1 cm) performed a maximal incremental test to determine the respiratory compensation point (RCP) (initial intensity at 70 W and increments of 17.5 W every 2 minutes) and a lactate minimum test (induction with the Wingate test, the incremental test started at 30 W below RCP with increments of 10 W every 3 minutes) on a cycle ergometer. The iLACmin was determined using second order polynomial adjustment applying five exercise stage selection: 1) using all stages (iLACmin P); 2) using all stages below and two stages above iLACminP(iLACminA); 3) using two stages below and all stages above iLACminP(iLACminB); 4) using the largest and same possible number of stages below and above the iLACminP(iLACminI); 5) using all stages and peak lactate after hyperlactatemia induction (iLACminD). No differences were found between the iLACminP(138.2±30.2 W), iLACminA(139.1±29.1 W), iLACminB(135.3±14.2 W), iLACminI(138.6±20.5 W) and iLACmiD(136.7±28.5 W) protocols, and a high level of agreement between these intensities and iLACminPwas observed. Oxygen uptake, heart rate, rating of perceived exertion and lactate corresponding to these intensities was not different and was strongly correlated. However, the iLACminBpresented the lowest success rate (66.7%). In conclusion, stage selection did not influence the determination of iLACmin but modified the success rate. © Creative Commom.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objectives: To investigate the test-retest reliability of mechanical parameters derived from a 3-min isokinetic all-out test, performed at 60 and 100 rpm. Reliability and validity of the peak oxygen uptake derived from 3-min isokinetic all-out test were also tested. Design: 14 healthy male subjects completed an incremental ramp testing and four randomized 3-min isokinetic all-out test (two at 60 rpm and two at 100 rpm). Methods: The absolute and relative reliability of the following parameters were analyzed: peak power, mean power, end power, fatigue index, work performed above end power and peak oxygen uptake. Results: No difference was found between each two sets of data, although there were between-cadence differences for peak power, mean power, end power, and fatigue index. Higher intra-class correlation (ICC) and lower coefficient of variation (CV) were found for end power (ICC = 0.91 and 0.95; CV = 5.6 and 5.7%) and mean power (ICC = 0.97 and 0.98; CV = 2.4 and 3.1%), than for peak power (ICC = 0.81 and 0.84; CV = 8.7 and 10%) and work performed above end power (ICC = 0.79 and 0.84; CV = 7.9 and 10.6%; values reported for 60 rpm and 100 rpm, respectively). High reliability scores were also observed for peak oxygen uptake at both cadences (60 rpm, CV = 3.2%; 100 rpm, CV = 2.3%,) with no difference with the incremental ramp testing peak oxygen uptake. Conclusions: The power profile and peak oxygen uptake of a 3-min isokinetic all-out test are both highly reliable, whether the test is performed at 60 or 100 rpm. Besides, peak oxygen uptake and work performed above end power were not affected by the change in cadence while peak power, mean power, end power, and fatigue index were. © 2013.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Pós-graduação em Fisioterapia - FCT

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)