913 resultados para orders of worth
Resumo:
A capillary electrophoresis-amperometric detection system was developed for the determination of propranolol (PRO) at a 33 mu m carbon fiber microdisk electrode (CFE). The cyclic voltammogram, the hydrodynamic voltammograms and the effect of pH were studied. Under the optimum conditions: separation Voltage 15 kV; injection 3 s at 15 kV; 10 mM pH 7.5 phosphate buffer, 1.15 V (vs. Ag/AgCl) detection potential, the detection limit (LOD) for PRO was 0.05 mu M (S/N = 3). The response for PRO was linear over two orders of magnitude with a linear correlation coefficient of 0.994. The feasibility of this method was demonstrated by the detection of PRO in urine sample.
Resumo:
Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of barbituric acid (BA) and 2-thiobarbituric acid (TA) has been described. Under optimum condition, BA and TA were separated satisfactorily, and a response of high sensitivity and stability was obtained at a detection potential of 1.25 V versus Ag/AgCl. Optimized end-column detection provides detection limit as low as 0.5 and 0.1 mu M for BA and TA, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 10) of peak currents and migration times obtained for both BA and TA were 3.4, 3.7, and 1.7, 1.2%, respectively. The proposed method has been applied to analyze water sample with satisfactory results. (C) 2000 Elsevier Science B.V. All rights reserved.
Resumo:
Electroluminescent devices using a ternary europium complex Eu(DBM)(3)(hhpy)(2) (dibenzoylmethane, DBM; hexahydro pyridine, hhpy) as an emitting layer, poly(vinyl-carbazole) (PVK) as a hole-transporting material and tris-(8-hydroxyquinoline) aluminum (Alq(3)) as an electron-transporting material have been fabricated. When only using Eu(DBM)(3)(hhpy)(2) as the emitting layer, luminance of 2.52 cd/m(2) with pure Eu3+ EL emissions from devices is achieved. Introducing a hole transporting material PVK and an electron transporting material 2-(4-biphenylyl)-5-(4-tert-butylphenyl)-1,3,4-oxidiazole (PBD) in the emitting layer, luminance of 100cd/m(2) is achieved, and the eletroluminescence efficiency is enhanced by about two orders of magnitude. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
Determination of aesculin (AL) and aesculetin (AT) by capillary electrophoresis with end-column amperometric detection using a 33 mu m microdisk carbon fiber electrode is described. The HDVs, the effect of pH, buffer concentration, injection voltage, injection time and separation voltage on the peak current response (i(p)) of the analytes and the number of theoretical plates (N) were studied. The method has high sensitivity and good reproducibility. Under the optimum condition - 10 mM, pH 9.00 phosphate buffer, 4 s at 9 kV injection, separation at 15 kV and +1.0 V as the detection potential - low detection limits (S/N = 3) of 0.06 and 0.3 mu M were obtained for AL and AT, respectively. The calibration curve was linear over three orders of magnitude. The relative standard deviations (n = 15) of peak current and migration time were 3.9% and 4.6%, and 0.96% and 0.75% for 15 consecutive injections of 5 mu M AL and AT, respectively. The use of this method for the separation and detection of the two compounds present in the traditional Chinese medicine and human urine samples is also reported. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
In this communication we analyse current versus voltage data obtained using one carrier injection at metal/polymer/metal structures, The used polymer is a soluble blue-emitting alternating block copolymer, Our experimental results demonstrate that the electron current is limited by a large amount of traps with exponential energy distribution in the copolymer. The electron ;mobility of 5.1 x 10(-10) cm(2)/V s is directly determined by space-charge-limited current measurements. The electron mobility is at least three orders of magnitude smaller than that for holes in the copolymer. (C) 1999 Elsevier Science Ltd. All rights reserved.
Resumo:
Promethazine and thioridazine were separated and detected by capillary electrophoresis with end-column amperometric detection. The influence of pH Value on oxidation potential, the peak current and the resolution were studied and the following conditions was selected: 0.03 M Na2HPO4 and 0.015 M citric acid at pH 3.0, detection potential at 1.10 V. The detection limits of these two substances were in the range of 10(-8) mol/l. The linear range spanned two to three orders of magnitude. This method was applied to the detection of promethazine and thioridazine spiked in urine. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
Capillary electrophoresis (CE)/electrochemical detection (EC) for the simultaneous detection of hydrazine, methylhydrazine, and isoniazid has been developed with a 4-pyridyl hydroquinone self-assembled microdisk platinum electrode. Such an electrode has very high catalytic ability for hydrazines and they could be detected even at 0.0 V. The responses for hydrazine, methylhydrazine, and isoniazid are linear over 3 orders of detected concentration and of magnitude of 0.2-400 mu M, 0.2-400 mu M, 0.5 mu M-2 mM, with correlation coefficients of 0.9998, 0.9991, and 0.9982, respectively. And they could be detected to levels of 0.1, 0.1 and 0.2 mu M, respectively. This modified electrode was found to be very stable and reproducible when continuously used as detector for capillary electrophoresis for period of at least 4 weeks with no apparent loss of response. (C) 1999 Elsevier Science B.V. All rights reserved.
Resumo:
Capillary electrophoresis (CE) with end-column electrochemical detection (EC) of sulfadiazine (SDZ) and sulfamethoxazole (SMZ) is described. Under the optimum conditions, SDZ and SMZ were separated satisfactorily, and a highly sensitive and stable response was obtained at a potential of 1.1 V versus Ag/AgCl. Optimized end-column detection provides detection limits as low as 0.1 mu M for both compounds, which corresponds to 0.024 and 0.021 fmol with peak efficiencies of 394000 and 335000 theoretical plates for SDZ arid SMZ, respectively. The calibration graph was linear over three orders of magnitude. The relative standard deviations (n = 12) of peak currents and migration times were 2.3 and 2.7%, and 0.8 and 1.3%, respectively, for the two compounds. The proposed method was applied to the analysis of tablets and human urine samples with satisfactory results.
Resumo:
A palladium particle-modified carbon fiber microdisk array electrode was designed and employed in capillary electrophoresis for the simultaneous detection of hydrazine, methylhydrazine, and isoniazid. The Pd-modified microdisk electrode had high catalytic ability for hydrazines and exhibited good reproducibility and stability. The response for hydrazine was linear over 3 orders of magnitude with a correlation coefficient of 0.993. The detection limits far hydrazine, methylhydrazine, and isoniazid were 1.2, 2.1, and 6.2 pg, respectively.
Resumo:
Permeability coefficients of H-2, O-2, and N2 were measured under 10 atm at the temperature from ambient temperature up to 150 degrees C in a series of structurally different aromatic homo- and copolyimides, which were prepared from 4,4'-oxydianiline (ODA) or 4,4'-methylene dianiline (MDA) with various aromatic dianhydrides. The study shows that the molecular structure of the polyimides strongly influences gas permeability and permselectivity. As a result, the permeability coefficients of the polyimide membranes for each gas vary by over two orders of magnitude. In general, among the polyimide membranes studied, the increase in permeability of polymers is accompanied by the decrease in permselectivity, and the MDA-based polyimide membranes have higher permeability than ODA-based ones. Among the polyimides prepared from bridged dianhydrides, the permeability coefficients to H-2, O-2, and N-2 are progressively increased in the order BPDA < BTDA < ODPA similar to TDPA < DSDA ( SiDA < 6FDA, while H-2/N-2 and O-2/N-2 permselectivity coefficients are progressively decreased in the same order. The copolyimide membranes, which were prepared from 3,3',4,4' biphenyltetracarboxylic dianhydride (BPDA), bis(3,4-dicarboxyphenyl)dimethylsilane dianhydride (SiDA), and ODA, have favorable gas separation properties and are useful for H-2/N-2 separation applications. (C) 1996 John Wiley & Sons, Inc.
Resumo:
An electrochemical pretreatment regime for a cylindrical carbon fibre microelectrode was optimized for the determination of aminopyrine (AM) and its metabolite 4-aminoantipyrine (AAN) by capillary electrophoresis (CE)-electrochemical detection (ED). Under optimized conditions, a response of high sensitivity and stability was obtained for AM and AAN at a detection voltage as low as 0.9 V following CE-ED, by which AM and AAN were separated satisfactorily. The calibration graph was linear over three orders of magnitude and the limits of detection for AM and AAN were in the femtomole range.
Resumo:
It is found that there is a linear relationship between log P-w, and the parameter term V-f/0.5 E(coh) [1+(delta(w) - delta(p))(2)/delta(p)(2), from the water permeability (P-w) data of 21 polymers covering 4 orders of magnitude. This correlation may be useful in choosing membrane materials for dehumidification of gases.
Resumo:
A glassy carbon electrode coated with an electrodeposited film of mixed-valent cobalt oxide/cyanocobaltate (Co-O/CN-Co) enabled hydrazine compounds to be catalytically oxidized at the greatly reduced overpotential and in a wide operational pH range (pH 2.0-7.0). Electrocatalytic activity at the Co-O/CN-Co modified electrode was evaluated with respect to solution pH, film thickness, supporting electrolyte ions, potential scan rate, operating potential, concentration dependence and other variables. The Co-O/CN-Co film electrode was completely compatible with a conventional reversed-phase liquid chromatographic (RP-LC) system. Practical RP-LC amperometric detection (RP-LCEC) of hydrazines was performed. A dynamic linear response range over three orders of magnitude and a detection limit at the pmol level were readily obtained. The Co-O/CN-CO film electrode exhibited excellent electrocatalytic stability in the flowing streams.
Resumo:
A new liquid chromatography electrochemical (LCEC) scheme for glucose sensing has been developed on the basis of a Prussian Blue chemically modified electrode (CME) of novel construction and characterized in terms of various experimental parameters by the flow injection analysis (FIA) technique. Unique hydrodynamic voltammograms were obtained for the first time at the CME in the flow-through amperometric detection of glucose, and subsequently both anodic and cathodic peaks could be expected on monitoring the operating potential in the modest positive or negative region. The unique pH dependence on the CME response towards glucose makes it perfectly compatible with conventional reversed phase liquid chromatography systems. On the basis of these features, practical application in glucose LCEC detection has been effectively performed; a linear response range over three orders of magnitude and a detection limit of subpicomole level were readily obtained. The capability of the established LCEC mode in the direct sensing of urinary glucose has been demonstrated.
Resumo:
A vitamin B-12 chemically modified electrode (CME) was constructed by adsorption of vitamin B-12 onto a glassy carbon surface. The electrode catalyzes the electrooxidation of hydrazine compounds over a wide pH range. The electrocatalytic behavior of hydrazines is elucidated with respect to the CME preparation conditions, solution pH, operating potential, mobile phase flow rate, and other variables. When applied to liquid chromatographic detection of the analytes, the vitamin B-12 CME yielded a linear response range over 2 orders of magnitude, and detection limits at the picomole level. The vitamin B-12 CME offers acceptable catalytic stability in both batch and flow systems.