950 resultados para municipal water supply
Resumo:
Upward leakage of saline water from an artesian aquifer below 1,500 feet has caused an increase in chloride concentration in the lower Hawthorn aquifer from less than 1,000 mg/1 (milligrams per liter) to values ranging from about 1,300 to 15,000 mg/1. Similarly the higher temperatures of the intruding water has caused an increase in water temperatures in the aquifer from 82"F to values ranging from 83 to 93"F. The intruding water moves upward either through the open bore hole of deep wells or test holes, or along a fault or fracture system, which has been identified in the area. From these points of entry into the lower Hawthorn aquifer, the saline water spreads laterally toward the south and southeast, but is generally confined to components of the fault system. The saline water moves upward from the lower Hawthorn aquifer into the upper Hawthorn aquifer through the open bore hole of wells, which connect the aquifers. This movement has resulted in an increase in chloride from less than 200 mg/1 in the unaffected parts of the upper Hawthorn aquifer to values commonly ranging from about 300 to more than 3,000 mg/1 in parts of the aquifer affected by upward leakage. The upper Hawthorn aquifer is the principal source of ground-water supply for public water-supply systems in western Lee County. Similar effects have been noted in the water-table aquifer, where chloride increased from less than 100 to concentrations ranging from about 500 to more than 5,000 mg/1. This was caused by the downward infiltration of water discharged at land surface from wells tapping the lower Hawthorn aquifer. The spread of saline water throughout most of the McGregor Isles area is continuing as of 1971. (40 page document)
Resumo:
The scope of the investigation involved the drilling of test holes and the detailed inventorying of existing wells in order to define the location, depth, potential yield, and chemical quality of the water contained in the shallow aquifer that might be used for the development of a central water-supply system. The field work and collection of data for the investigation covered the period 1961 through 1963. Much of the data collected for the report on the ground-water resources of Collier County (McCoy, 1962) is incorporated into this report. (Document has 36 pages.)
Resumo:
The production of certain odorous metabolites is an undesirable attribute of cyanobacteria (blue-green algae) growth in aquaculture ponds [e.g., channel catfish(Ictalurus punctatus)] and in drinking water reservoirs. The most common odorous compounds encountered in catfish aquaculture are geosmin (trans-1,10-dimethyltrans-9-decalol) and 2-methylisoborneol(exo-1,2,7,7-tetramethylbicyclo[2.2.1]heptan-2-ol). These compounds are also frequently encountered worldwide in reservoirs and aqueducts used for municipal drinking water systems(Schrader et al. 2002). In this study, several algicides were evaluated using a rapid bioassay to determine their effectiveness in controlling the MIB-producing cyanobacterium Oscillatoria perornata from a west Mississippi catfish pond and the MIBproducing Pseudanabaena sp. (strain LW397) from Lake Whitehurst, Virginia, used as a city water supply reservoir. The cyanobacterium Oscillatoria agardhii , not a MIB-producer, and the green alga Selenastrum capricornutum , found in catfish ponds in the southeastern United States, were included in the bioassay to help determine potential broad-spectrum toxicity of the commercial products. (PDF has 3 pages.)
Resumo:
Um Atlas Digital é um atlas que foi concebido através de técnicas computacionais e que, consequentemente, pode ser acessado através de um computador. Estruturado em um ambiente gráfico, além dos mapas, pode-se contar também com textos, fotografias, dados estatísticos, gráficos e tabelas. Por estar em meio digital existe a possibilidade de utilização de uma expressiva gama de temas, formatos e escalas. Nesta dissertação apresenta-se um protótipo de Atlas Digital como uma colaboração ao Sistema de Informação Municipal SIM, para o município de São João de Meriti, RJ. O referido SIM, que tem como meta os serviços municipais, visa atender ao próprio município, ao cidadão e a outros interessados na cidade, sendo as suas informações fundamentais para a melhoria da gestão das prefeituras. A pesquisa foi direcionada para o tema da habitabilidade, que consiste num conjunto de condições voltadas para a construção de habitat saudável, abrangendo temas físicos, psicológicos, sociais, culturais e ambientais. Dentro do tema habitabilidade, foram trabalhados os subtemas relativos a infraestrutura de abastecimento de água, esgoto, coleta de lixo, saúde e educação, esses subtemas foram confrontados entre si para uma comparação entre os bairros do município. O SIM e a habitabilidade são contemplados no plano diretor da cidade e representa uma grande parte da sustentação teórica da dissertação. A modelagem e implementação do protótipo do Atlas Digital foram feitas com auxílio de softwares gratuitos, sendo possível acessar mapas temáticos e outras informações sobre São João de Meriti
Resumo:
Guided by experience and the theoretical development of hydrobiology, it can be considered that the main aim of water quality control should be the establishment of the rates of the self-purification process of water bodies which are capable of maintaining communities in a state of dynamic balance without changing the integrity of the ecosystem. Hence, general approaches in the elaboration of methods for hydrobiological control are based on the following principles: a. the balance of matter and energy in water bodies; b. the integrity of the ecosystem structure and of its separate components at all levels. Ecosystem analysis makes possible a revelation of the whole totality of factors which determine the anthropogenic evolution of a water body. This is necessary for the study of long-term changes in water bodies. The principles of ecosystem analysis of water bodies, together with the creation of their mathematical models, are important because, in future, with the transition of water demanding production into closed cycles of water supply, changes in water bodies will arise in the main through the influence of 'diffuse' pollution (from the atmosphere, with utilisation in transport etc.).
Resumo:
Biomanipulation is a form of biological engineering in which organisms are selectively removed or encouraged to alleviate the symptoms of eutrophication. Most examples involve fish and grazer zooplankton though mussels have also been used. The technique involves continuous management in many deeper lakes and is not a substitute for nutrient control. In some lakes, alterations to the lake environment have given longer-term positive effects. And in some shallow lakes, biomanipulation may be essential, alongside nutrient control, in re- establishing former aquatic-plant-dominated ecosystems which have been lost through severe eutrophication. The emergence of biomanipulation techniques emphasises that lake systems are not simply chemical reactors which respond simply to engineered chemical changes, but very complex and still very imperfectly understood ecosystems which require a yet profounder understanding before they can be restored with certainty.
The significance of sedimentation and sediments to phytoplankton growth in drinking-water reservoirs
Resumo:
In the mesotrophic-eutrophic Saidenbach Reservoir in Saxony, the nanoplankton and cyanobacteria have increased at the expense of diatom dominance, due to a doubling of the external phosphorus load in the last 15 years. However, the phosphorus sedimentation flux is still very high (up to 80% of the input), corresponding to more than 2 g m2 d-1 in terms of dry weight. There is a strong correlation between the abundance of diatoms in the euphotic zone and their sedimentation flux (with a delay of about 2 weeks). Only about 25% of the deposited material could be clearly attributed to plankton biomass; the remainder resulted from flocculation and precipitation processes or directly from the inflow of clay minerals. The ash content of the deposited material was high (73%). Thus the sedimentation flux can be considered to operate as an internal water-treatment/oligotrophication process within the lake. The neighbouring Neunzehnhain Reservoir still has a very clear water with a transparency up to 18 m depth. Though the sediment was not much lower than Saidenbach sediment in total phosphorus and total numbers of bacteria, sulphide was always absent and the ratio of Fe 2+ to Fe 3+ was very low in the upper (0- 5 cm) layer. Thus the external and internal phosphorus loads do not attain the critical level necessary to induce a ”phosphorus - phytoplankton” feedback loop.
Resumo:
Esthwaite Water is the most productive or eutrophic lake in the English Lake District. Since 1945 its water quality has been determined from weekly or biweekly measurements of temperature, oxygen, plant nutrients and phytoplankton abundance. The lake receives phosphorus from its largely lowland-pasture catchment, sewage effluent from the villages of Hawkshead and Near Sawrey, and from a cage-culture fish farm. From 1986 phosphorus has been removed from the sewage effluent of Hawkshead which was considered to contribute between 47% and 67% of the total phosphorus loading to the lake. At the commencement of phosphorus removal regular measurements of phosphorus in the superficial 0-4 cm layer of lake sediment were made from cores collected at random sites. Since 1986 the mean annual concentration of alkali-extractable sediment phosphorus has decreased by 23%. This change is not significant at the 5% level but nearly so. There has been no marked change in water quality over this period. Summer dominance of blue-green algae which arose in the early 1980s after decline of the previous summer forms, Ceratium spp., has been maintained. Improvement in water quality is unlikely to be achieved at the present phosphorus loading.
Resumo:
Like other rivers in the Paris area, the Oise is subject to important seasonal algal blooms. This eutrophication generates notable problems for the production of drinking-water from a treatment plant on the river at Méry. A mathematical model has been developed to simulate variation in water quality in a pre-treatment storage basin, and another model is currently being adapted to model the River Oise. Integration of the two models should provide a comprehensive tool for predicting variations of phytoplankton and water-quality parameters associated with algal blooms. This will be a decision-aid for optimizing control of the treatment process for providing potable water.
Resumo:
Tastes and odours are amongst the few water quality standards immediately apparent to a consumer and, as a result, account for most consumer complaints about water quality. Although taste and odour problems can arise from a great many sources, from an operational point of view they are either ”predictable” or ”unpredictable”. The former - which include problems related to actinomycete and algal growth - have a tendency to occur in certain types of water under certain combinations of conditions, whereas the latter - typically chemical spills - can occur anywhere. Long-term control is one option for predictable problems, although biomanipulation on a large scale has had utile success. Detection and avoidance is a more practicable option for both predictable and unpredictable problems, particularly if the distribution network can be serviced from other sources. Where these are not feasible, then water treatment, typically using activated carbon, is possible. In general there is a reasonable understanding of what compounds cause taste and odour problems, and how to treat these. An efficient taste and odour control programme therefore relies ultimately on good management of existing resources. However, a number of problems lie outside the remit of water supply companies and will require more fundamental regulation of activities in the catchment.
Resumo:
Whilst current methods for the isolation and enumeration of Cryptosporidium spp. oocysts in water have provided some insight into their occurrence and significance, they are regarded as being inefficient, variable and time-consuming, with much of the interpretation being left to the expertise of the analyst. Two expectations of novel developments are to reduce the variability and subjectivity associated with the isolation and identification of oocysts. Flocculation, immunomagnetisable and flow cytometric techniques, for concentrating oocysts from water samples, should prove more reliable than current methods, whilst the development of more avid and specific monoclonal antibodies in conjunction with the use of nuclear fluorochromes will aid identification. Further insight into the viability, taxonomy, species identification, infectivity and virulence of the parasite should be forthcoming through the use of techniques such as the polymerase chain reaction, in situ hybridisation and non-uniform alternating current electrical fields. Such information is necessary in order to enable microbiologists, epidemiologists, engineers, utility operators and regulators to assess the safety of a water supply, with respect to Cryptosporidium contamination, more effectively.
Resumo:
This is the Water Level Management Plan for the Rostherne Mere by the Environment Agency. The purpose of the Plan is to provide a formal basis for managing the land drainage system and water supply system of the area in order to provide a sustainable balance between the conservation and agricultural interest in the area. No changes are proposed to present water level management or maintenance practices unless and until such changes are agreed by all parties. The report contains sections on description of Site, water level management, maintenance, nature conservation, agriculture, fisheries, archaeology, water quality and water resources, development adjacent to watercourses, contingencies and objectives of the Water Level Management.
Resumo:
Baltimore Harbor is polluted by discharge of sewage and industrial wastes into tributary streams and peripheral waters. The Harbor is used extensively for navigation, industrial water supply, and recreation as well as for waste disposal. The degree of pollution varies from negligible in the principal fairway to severe in the innermost sections. Private industry discharges several hundred tons of acid materials daily and is also the principal source of organic pollution.