974 resultados para mobile telefonia back-end


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To investigate the effects of low and high levels of positive end-expiratory pressure (PEEP), without recruitment maneuvers, during lung protective ventilation in an experimental model of acute lung injury (ALI). Design: Prospective, randomized, and controlled experimental study. Setting: University research laboratory. Subjects: Wistar rats were randomly assigned to control (C) [saline (0.1 ml), intraperitoneally] and ALI [paraquat (15 mg/kg), intra peritoneally] groups. Measurements and Main Results: After 24 hours, each group was further randomized into four groups (six rats each) at different PEEP levels = 1.5, 3, 4.5, or 6 cm H(2)O and ventilated with a constant tidal volume (6 mL/kg) and open thorax. Lung mechanics [static elastance (Est, L) and viscoelastic pressure (Delta P2, L)] and arterial blood gases were measured before (Pre) and at the end of 1-hour mechanical ventilation (Post). Pulmonary histology (light and electron microscopy) and type III procollagen (PCIII) messenger RNA (mRNA) expression were measured after 1 hour of mechanical ventilation. In ALI group, low and high PEEP levels induced a greater percentage of increase in Est, L (44% and 50%) and Delta P2, L (56% and 36%) in Post values related to Pre. Low PEEP yielded alveolar collapse whereas high PEEP caused overdistension and atelectasis, with both levels worsening oxygenation and increasing PCIII mRNA expression. Conclusions: In the present nonrecruited ALI model, protective mechanical ventilation with lower and higher PEEP levels than required for better oxygenation increased Est, L and Delta P2, L, the amount of atelectasis, and PCIII mRNA expression. PEEP selection titrated for a minimum elastance and maximum oxygenation may prevent lung injury while deviation from these settings may be harmful. (Crit Care Med 2009; 37:1011-1017)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES To evaluate the initial results of a prostate cancer screening program using mobile units in Brazil. METHODS Since 2004, we have conducted a program of prostate cancer screening using mobile units across 231 municipalities from 6 Brazilian states. RESULTS A total of 17 571 men were evaluated by clinical history, digital rectal examination (DRE), and serum free and total prostate-specific antigen (PSA) levels. The recommendations for biopsy were a PSA level of >= 4.0 ng/mL, DRE findings suspicious for cancer, or a PSA level of 2.5-4.0 ng/mL with a percent-free PSA level <15%. The biopsy protocol included 12 biopsy cores from the peripheral zone, 2 from the transition zone, and additional sampling of suspicious areas. The cumulative cancer detection rate was 3.7%. The main indication for biopsy was a PSA level of >= 4.0 ng/mL (51.2%), with a positive predictive value (PPV) of 44.1%. Another 19.7% of biopsied men had suspicious DRE findings with a normal PSA level (PPV 23.5%). A percent-free PSA level of <15% in men with a PSA level of 2.5-4.0 ng/mL and normal DRE findings yielded a PPV of 31.1%. The PPV was greater (70.9%) for the 7.1% of men with both suspicious DRE findings and a PSA level of >4.0 ng/mL. Most cancers were Stage T1-T2 (93.4%), and the percentage of Gleason score of >= 7 was 32.5%. The proportion of insignificant cancers according to Epstein`s criteria was 13.5%. CONCLUSIONS A mobile prostate cancer screening unit enabled an underserved population to gain access to specialized care through the public healthcare system. The cancer detection rate in this population was similar to those from international studies. UROLOGY 76: 1052-1057, 2010. (C) 2010 Published by Elsevier Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sepsis is the systemic inflammatory response syndrome secondary to a local infection, and severe sepsis and septic shock are the more devastating scenarios of this disease. In the last decade, considerable achievements were obtained in sepsis knowledge, and an international campaign was developed to improve the treatment of this condition. However, sepsis is still one of the most important causes of death in intensive care units. The early stages of sepsis are characterized by a variety of hemodynamic derangements that induce a systemic imbalance between tissue oxygen supply and demand, leading to global tissue hypoxia. This dysfunction, which may occur in patients presenting normal vital signs, can be accompanied by a significant increase in both morbidity and mortality. The early identification of high-risk sepsis patients through tissue perfusion markers such as lactate and venous oxygen saturation is crucial for prompt initiation of therapeutic support, which includes early goal-directed therapy as necessary. The purpose of this article was to review the most commonly used hemodynamic and perfusion parameters for hemodynamic optimization in sepsis, emphasizing the physiological background for their use and the studies that demonstrated their effectiveness as goals of volemic resuscitation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: To evaluate the cardiopulmonary effects of positive end-expiratory pressure (PEEP) equalization to intra-abdominal pressure (IAP) in an experimental model of intra-abdominal hypertension (IAH) and acute lung injury (ALI). Methods: Eight anesthetized pigs were submitted to IAH of 20 mm Hg with a carbon dioxide insufflator for 30 minutes and then submitted to lung lavage with saline and Tween (2.5%). Pressure x volume curves of the respiratory system were performed by a low flow method during IAH and ALI, and PEEP was subsequently adjusted to 27 cm center dot H(2)O for 30 minutes. Results: IAH decreases pulmonary and respiratory system static compliances and increases airway resistance, alveolar-arterial oxygen gradient, and respiratory dead space. The presence of concomitant ALI exacerbates these findings. PEEP identical to AP moderately improved oxygenation and respiratory mechanics; however, an important decline in stroke index and right ventricle ejection fraction was observed. Conclusions: Simultaneous IAH and ALI produce important impairments in the respiratory physiology. PEEP equalization to AP may improve the respiratory performance, nevertheless with a secondary hemodynamic derangement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. To examine the effects of betamethasone administration on umbilical artery (UA), middle cerebral artery (MCA) and ductus venosus (DV) Doppler flow. Design. Longitudinal prospective study. Setting: Fetal Surveillance Unit, Department of Obstetrics and Gynecology, University of Sao Paulo, Sao Paulo, Brazil. Population. Thirty-two singleton pregnancies complicated by fetal growth restriction with absent end-diastolic flow in the UA. Methods. Pulsatility index (PI) of the UA, MCA and DV was measured from 26 to 34 weeks prior to and within 24 or 48 hours after starting betamethasone treatment course. Analysis of variance for repeated measures was used to determine the changes in the fetal hemodynamic Doppler flow following maternal corticosteroid administration. Main outcome measures. Improvement of UA-PI within 24 hours and DV-PIV (venous pulsatility) within 48 hours from the first betamethasone dose. Results. Mean gestational age at delivery was 29.3 (1.8) weeks and birthweight was 806.6 (228.2) g. A reduction in the UA-PI was observed in 29 (90.6%) cases, with return of end-diastolic flow in 22 (68.7%). The mean UA-PI were 2.84 (0.52) before corticosteroid administration, 2.07 (0.56) within 24 hours and 2.42 (0.75) after 48 hours, with a significant difference along the evaluations (p0.001). No significant changes in the MCA Doppler were observed. DV-PIV decreased from 1.06 (0.23) prior corticosteroids administration to 0.73 (0.16) within 24 hours and 0.70 (0.19) after 48 hours (p0.001). Conclusions. There was reduction in the umbilical artery and in the DV pulsatility indices within 24 hours from betamethasone administration that was maintained up to 48 hours.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To develop a new endoscopic approach to the correction of a myelomeningocele-like defect in fetal sheep. Methods: The fetuses of 9 pregnant ewes, with an average gestational age of 115 days, were subjected to a 3.0 x 2.0 cm removal of the skin over the lumbar spine, performed through hysterotomy. The uterus was closed, and three 5-mm endoscopic cannulas, without valve mechanisms, were inserted. In the pilot phase (2 animals), we initially worked exclusively in the amniotic fluid space. In the study phase, we partially withdrew the fetus from the amniotic fluid to completely expose its back. By simply allowing air to enter the amniotic cavity (without gas injection), a working space was created using a uterine lift device. The skin around the defect was dissected, and a biosynthetic cellulose material was applied to cover the area. A continuous suture of the skin was performed to completely hide the material. Results: The combined air/fluid space allowed the skin to be successfully closed in 6 out of 7 cases in the study phase. All fetuses were alive at the end of the procedures. Time to complete the endoscopic part of the procedure fell from 3 to 1 h by the end of this series. Premature birth occurred in 2 of the 4 cases allowed to continue with the pregnancy. Conclusion: A new gasless fetoscopic surgery technique was developed as an alternative to current techniques used for fetal endoscopic surgery. Copyright (C) 2008 S. Karger AG, Basel.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador: