959 resultados para lithic artifacts
Resumo:
During the fieldwork in the medieval fortification of Ausa (Gipuzkoa), a vast amount of sherds from several pottery artifacts featured by a cylindrical body has been found out. They presumably had the same function in contexts dated from the first half of xiv century. Although it has not been possible to reconstruct any of these artefacts, the study of the sherds allows us to think that they would have formed some sort of big-sized horn. This high-sounding instrument, which has been frequently reproduced in iconographic references, does not have at this moment any direct parallelism in Hispanic contexts, despite being plentiful of references to similar objects in medieval ranges from Provence and Languedoc. By introducing these artefacts from different approaches, we aim to go over the scarce knowledge of these instruments, whose evidence lets us to believe in their widespread distribution all over the landscape in several material contexts from Medieval Ages.
Resumo:
Although fetal anatomy can be adequately viewed in new multi-slice MR images, many critical limitations remain for quantitative data analysis. To this end, several research groups have recently developed advanced image processing methods, often denoted by super-resolution (SR) techniques, to reconstruct from a set of clinical low-resolution (LR) images, a high-resolution (HR) motion-free volume. It is usually modeled as an inverse problem where the regularization term plays a central role in the reconstruction quality. Literature has been quite attracted by Total Variation energies because of their ability in edge preserving but only standard explicit steepest gradient techniques have been applied for optimization. In a preliminary work, it has been shown that novel fast convex optimization techniques could be successfully applied to design an efficient Total Variation optimization algorithm for the super-resolution problem. In this work, two major contributions are presented. Firstly, we will briefly review the Bayesian and Variational dual formulations of current state-of-the-art methods dedicated to fetal MRI reconstruction. Secondly, we present an extensive quantitative evaluation of our SR algorithm previously introduced on both simulated fetal and real clinical data (with both normal and pathological subjects). Specifically, we study the robustness of regularization terms in front of residual registration errors and we also present a novel strategy for automatically select the weight of the regularization as regards the data fidelity term. Our results show that our TV implementation is highly robust in front of motion artifacts and that it offers the best trade-off between speed and accuracy for fetal MRI recovery as in comparison with state-of-the art methods.
Resumo:
PURPOSE: To improve coronary magnetic resonance angiography (MRA) by combining a two-dimensional (2D) spatially selective radiofrequency (RF) pulse with a T2 -preparation module ("2D-T2 -Prep"). METHODS: An adiabatic T2 -Prep was modified so that the first and last pulses were of differing spatial selectivity. The first RF pulse was replaced by a 2D pulse, such that a pencil-beam volume is excited. The last RF pulse remains nonselective, thus restoring the T2 -prepared pencil-beam, while tipping the (formerly longitudinal) magnetization outside of the pencil-beam into the transverse plane, where it is then spoiled. Thus, only a cylinder of T2 -prepared tissue remains for imaging. Numerical simulations were followed by phantom validation and in vivo coronary MRA, where the technique was quantitatively evaluated. Reduced field-of-view (rFoV) images were similarly studied. RESULTS: In vivo, full field-of-view 2D-T2 -Prep significantly improved vessel sharpness as compared to conventional T2 -Prep, without adversely affecting signal-to-noise (SNR) or contrast-to-noise ratios (CNR). It also reduced respiratory motion artifacts. In rFoV images, the SNR, CNR, and vessel sharpness decreased, although scan time reduction was 60%. CONCLUSION: When compared with conventional T2 -Prep, the 2D-T2 -Prep improves vessel sharpness and decreases respiratory ghosting while preserving both SNR and CNR. It may also acquire rFoV images for accelerated data acquisition.
Resumo:
The question of whether symbolically mediated behavior is exclusive to modern humans or shared with anatomically archaic populations such as the Neandertals is hotly debated. At the Grotte du Renne, Arcy-sur-Cure, France, the Châtelperronian levels contain Neandertal remains and large numbers of personal ornaments, decorated bone tools and colorants, but it has been suggested that this association reflects intrusion of the symbolic artifacts from the overlying Protoaurignacian and/or of the Neandertal remains from the underlying Mousterian.
Resumo:
Abstract: On the application problem of efficiency artifacts - or why may intelligent organizations make only boundedly rational choices?
Resumo:
Systems made of parts that are totally connected do not work, neither ecosys- tems nor artifacts. Relative connectance is inversely related to diversity, and both magnitudes can find a common frame of expression, in which some constant expressing the constraints of any organization might be embodied. If S is Simp- son's index, the expression (1 - S)IS as a measure of diversity offers some advantages or, at least, helps further reasoning. Such expression is the ratio between total interspecific possible interactions and possible intraspecific inter- actions.
Resumo:
The CORNISH project is the highest resolution radio continuum survey of the Galactic plane to date. It is the 5 GHz radio continuum part of a series of multi-wavelength surveys that focus on the northern GLIMPSE region (10° < l < 65°), observed by the Spitzer satellite in the mid-infrared. Observations with the Very Large Array in B and BnA configurations have yielded a 1.''5 resolution Stokes I map with a root mean square noise level better than 0.4 mJy beam 1. Here we describe the data-processing methods and data characteristics, and present a new, uniform catalog of compact radio emission. This includes an implementation of automatic deconvolution that provides much more reliable imaging than standard CLEANing. A rigorous investigation of the noise characteristics and reliability of source detection has been carried out. We show that the survey is optimized to detect emission on size scales up to 14'' and for unresolved sources the catalog is more than 90% complete at a flux density of 3.9 mJy. We have detected 3062 sources above a 7σ detection limit and present their ensemble properties. The catalog is highly reliable away from regions containing poorly sampled extended emission, which comprise less than 2% of the survey area. Imaging problems have been mitigated by down-weighting the shortest spacings and potential artifacts flagged via a rigorous manual inspection with reference to the Spitzer infrared data. We present images of the most common source types found: H II regions, planetary nebulae, and radio galaxies. The CORNISH data and catalog are available online at http://cornish.leeds.ac.uk.
Resumo:
Neurophysiology is an essential tool for clinicians dealing with patients in the intensive care unit. Because of consciousness disorders, clinical examination is frequently limited. In this setting, neurophysiological examination provides valuable information about seizure detection, treatment guidance, and neurological outcome. However, to acquire reliable signals, some technical precautions need to be known. EEG is prone to artifacts, and the intensive care unit environment is rich in artifact sources (electrical devices including mechanical ventilation, dialysis, and sedative medications, and frequent noise, etc.). This review will discuss and summarize the current technical guidelines for EEG acquisition and also some practical pitfalls specific for the intensive care unit.
Resumo:
In this work, we propose a method for prospective motion correction in MRI using a novel image navigator module, which is triggered by a free induction decay (FID) navigator. Only when motion occurs, the image navigator is run and new positional information is obtained through image registration. The image navigator was specifically designed to match the impact on the magnetization and the acoustic noise of the host sequence. This detection-correction scheme was implemented for an MP-RAGE sequence and 5 healthy volunteers were scanned at 3T while performing various head movements. The correction performance was demonstrated through automated brain segmentation and an image quality index whose results are sensitive to motion artifacts.
Resumo:
Objective:To evaluate the evolution of mammographic image quality in the state of Rio de Janeiro on the basis of parameters measured and analyzed during health surveillance inspections in the period from 2006 to 2011.Materials and Methods:Descriptive study analyzing parameters connected with imaging quality of 52 mammography apparatuses inspected at least twice with a one-year interval.Results:Amongst the 16 analyzed parameters, 7 presented more than 70% of conformity, namely: compression paddle pressure intensity (85.1%), films development (72.7%), film response (72.7%), low contrast fine detail (92.2%), tumor mass visualization (76.5%), absence of image artifacts (94.1%), mammography-specific developers availability (88.2%). On the other hand, relevant parameters were below 50% conformity, namely: monthly image quality control testing (28.8%) and high contrast details with respect to microcalcifications visualization (47.1%).Conclusion:The analysis revealed critical situations in terms of compliance with the health surveillance standards. Priority should be given to those mammography apparatuses that remained non-compliant at the second inspection performed within the one-year interval.
Resumo:
Abstract Objective: To propose a protocol for pulmonary angiography using 64-slice multidetector computed tomography (64-MDCT) with 50 mL of iodinated contrast material, in an unselected patient population, as well as to evaluate vascular enhancement and image quality. Materials and Methods: We evaluated 29 patients (22-86 years of age). The body mass index ranged from 19.0 kg/m2 to 41.8 kg/m2. Patients underwent pulmonary CT angiography in a 64-MDCT scanner, receiving 50 mL of iodinated contrast material via venous access at a rate of 4.5 mL/s. Bolus tracking was applied in the superior vena cava. Two experienced radiologists assessed image quality and vascular enhancement. Results: The mean density was 382 Hounsfield units (HU) for the pulmonary trunk; 379 and 377 HU for the right and left main pulmonary arteries, respectively; and 346 and 364 HU for the right and left inferior pulmonary arteries, respectively. In all patients, subsegmental arteries were analyzed. There were streak artifacts from contrast material in the superior vena cava in all patients. However, those artifacts did not impair the image analysis. Conclusion: Our findings suggest that pulmonary angiography using 64-MDCT with 50 mL of iodinated contrast can produce high quality images in unselected patient populations.
Resumo:
This work investigates performance of recent feature-based matching techniques when applied to registration of underwater images. Matching methods are tested versus different contrast enhancing pre-processing of images. As a result of the performed experiments for various dominating in images underwater artifacts and present deformation, the outperforming preprocessing, detection and description methods are proposed
Resumo:
[spa] En el presente artículo se presentan los tres grandes ámbitos en los que se desarrolla la investigación arqueométrica sobre cerámicas: la identificación de los materiales, la proveniencia de los artefactos y la tecnología en la que se inscriben. El artículo hace una incidencia especial en aquello que se entiende por tecnología, indicando que la tecnología de producción es únicamente una parte de la misma, y que el concepto básico es el de diseño, que debe adecuarse a una multiplicidad de características de desempeño, explicadas por la cadena conductual en la cual transcurre la vida de los artefactos. Dado que las culturas se expresan por medio de artefactos, la vertiente material de éstos refleja, aunque sólo sea en parte, los compromisos que dichos artefactos tienen en las culturas en estudio. La arqueometría, con un cuerpo teórico y metodológico adaptado a la investigación de esta vertiente natural de los artefactos, aparece así como una forma complementaria de hacer arqueología y no como un campo de estudio diferenciado.
Resumo:
A capillary microtrap thermal desorption module is developed for near real-time analysis of volatile organic compounds (VOCs) at sub-ppbv levels in air samples. The device allows the direct injection of the thermally desorbed VOCs into a chromatographic column. It does not use a second cryotrap to focalize the adsorbed compounds before entering the separation column so reducing the formation of artifacts. The connection of the microtrap to a GC–MS allows the quantitative determination of VOCs in less than 40 min with detection limits of between 5 and 10 pptv (25 °C and 760 mmHg), which correspond to 19–43 ng m−3, using sampling volumes of 775 cm3. The microtrap is applied to the analysis of environmental air contamination in different laboratories of our faculty. The results obtained indicate that most volatile compounds are easily diffused through the air and that they also may contaminate the surrounding areas when the habitual safety precautions (e.g., working under fume hoods) are used during the manipulation of solvents. The application of the microtrap to the analysis of VOCs in breath samples suggest that 2,5-dimethylfuran may be a strong indicator of a person's smoking status
Resumo:
There is no evidence of urban civilization in Brazilian prehistory; most inhabitants lived in tribal groupings, probably with regional economic integration among several independent tribes. There is little evidence of seasonal migrations between the coast and the inland of southern Brazil. Some specialized horticulturists competed among themselves but other groups lived more isolated and probably peacefully, in the upper interfluvial regions. Chemical analysis of artifacts is a means of documenting traffic in particular materials and intraregional production and distribution, development of craft specialization and typological refinement among other issues. In this study we tested some possibilities in two different cultural contexts using the parametric k0 neutron activation analysis technique, which allowed the determination of elements: Al, As, Au, Ce, Cl, Co, Cr, Cs, Cu, Fe, Ga, K, La, Na, Rb, Sc, Ta, Ti, V and Zn.