984 resultados para laryngeal stenosis
Resumo:
BACKGROUND Current guidelines limit the use of high oxygen tension after return of spontaneous circulation after cardiac arrest, focusing on neurological outcome and mortality. Little is known about the impact of hyperoxia on the ischemic heart. Oxygen is frequently administered and is generally expected to be beneficial. This study seeks to assess the effects of hyperoxia on myocardia oxygenation in the presence of severe coronary artery stenosis in swine. METHODS AND RESULTS In 22 healthy pigs, we surgically attached a magnetic resonance compatible flow probe to the left anterior descending coronary artery (LAD). In 11 pigs, a hydraulic occluder was inflated distal to the flow probe. After increasing PaO2 to >300 mm Hg, LAD flow decreased in all animals. In 8 stenosed animals with a mean fractional flow reserve of 0.64±0.02, hyperoxia resulted in a significant decrease of myocardial signal intensity in oxygenation-sensitive cardiovascular magnetic resonance images of the midapical segments of the LAD territory. This was not seen in remote myocardium or in the other 8 healthy animals. The decreased signal intensity was accompanied by a decrease in circumferential strain in the same segments. Furthermore, ejection fraction, cardiac output, and oxygen extraction ratio declined in these animals. Changing PaCO2 levels did not have a significant effect on any of the parameters; however, hypercapnia seemed to nonsignificantly attenuate the hyperoxia-induced changes. CONCLUSIONS Ventilation-induced hyperoxia may decrease myocardial oxygenation and lead to ischemia in myocardium subject to severe coronary artery stenosis.
Resumo:
Background: Heart failure (CHF) is the most frequent and prognostically severe symptom of aortic stenosis (AS), and the most common indication for surgery. The mainstay of treatment for AS is aortic valve replacement (AVR), and the main indication for an AVR is development of symptomatic disease. ACC/AHA guidelines define severe AS as an aortic valve area (AVA) ≤1cm², but there is little data correlating echocardiogram AVA with the onset of symptomatic CHF. We evaluated the risk of developing CHF with progressively decreasing echocardiographic AVA. We also compared echocardiographic AVA with Jet velocity (V2) and indexed AVA (AVAI) to assess the best predictor of development of symptomatic CHF.^ Methods and Results: This retrospective cohort study evaluated 518 patients with asymptomatic moderate or severe AS from a single community based cardiology practice. A total of 925 echocardiograms were performed over an 11-year period. Each echocardiogram was correlated with concurrent clinical assessments while the investigator was blinded to the echocardiogram severity of AS. The Cox Proportional hazards model was used to analyze the relationship between AVA and the development of CHF. The median age of patients at entry was 76.1 years, with 54% males. A total of 116 patients (21.8%) developed new onset CHF during follow-up. Compared to patients with AVA >1.0cm², patients with lower AVA had an exponentially increasing risk of developing CHF for each 0.2cm² decrement in AVA, becoming statistically significant only at an AVA less than 0.8 cm². Also, compared to V2 and AVAI, AVA added more information to assessing risk for development of CHF (p=0.041). ^ Conclusion: In patients with normal or mildly impaired LVEF, the risk of CHF rises exponentially with decreasing valve area and becomes statistically significant after AVA falls below 0.8cm². AVA is a better predictor of CHF when compared to V2 or AVAI.^
Resumo:
When using the laryngeal tube and the intubating laryngeal mask airway (ILMA), the medium-size (maximum volume 1100 ml) versus adult (maximum volume 1500 ml) self-inflating bags resulted in significantly lower lung tidal volumes. No gastric inflation occurred when using both devices with either ventilation bag. The newly developed medium-size self-inflating bag may be an option to further reduce the risk of gastric inflation while maintaining sufficient lung ventilation. Both the ILMA and laryngeal tube proved to be valid alternatives for emergency airway management in the experimental model used.
Perceptual and instrumental analysis of laryngeal function after traumatic brain injury in childhood
Resumo:
Objective: To investigate laryngeal function and phonatory disturbance in children with traumatic brain injury (TBI), using both perceptual and instrumental techniques. Design and participants: The performance of 16 individuals with moderate to severe TBI acquired in childhood and 16 nonneurologicatly impaired control subjects was compared on a battery of perceptual (Frenchay Dysarthria Assessment, speech sample analysis) and instrumental (Aerophone II, laryngograph) assessments. Results and conclusions: As a group, the children with TBI demonstrated normal, or only minimally impaired laryngeal function, when compared with the control group, which contrasts with the significant laryngeal impairment noted in adults after TBI. Several reasons for the different findings in relation to laryngeal function in adults and children after TBI are postulated: (1) differing types of injury usually incurred by adults and children may result in a relatively decreased degree of neurologic impairment in these children, (2) differences in recovery potential between adults and children, and (3) the pediatric larynx is still developing, hence it may be better able to compensate for any impairment incurred.
Resumo:
Objectives. Pulsatile tinnitus is a rare and often disabling condition. Pulsatile tinnitus sometimes occurs in patients with severe atherosclerotic carotid stenosis. It is uncertain whether carotid endarterectomy (CEA) relieves pulsatile tinnitus in patients with severe carotid stenosis. Design, Materials and Methods. This is a retrospective study of 14 patients with pulsatile tinnitus who underwent CEA. Demographic and clinical features and pre-operative duplex results were recorded. Operative results in this group were assessed. Results. CEA relieved symptoms of pulsatile tinnitus in 10 out of 14 cases (70%). Of 10 patients that had lateralisable tinnitus and ipsilateral surgery, 9 (90%) reported symptomatic improvement. Conclusions. CEA is effective in improving pulsatile tinnitus in patients with unilateral symptoms and severe ipsilateral carotid stenosis.
Resumo:
Background and objective: There are no data about the influence of anaesthetics on cardiovascular variables during pressure support ventilation of the lungs through the laryngeal mask airway. We compared propofol, sevoflurane and isoflurane for maintenance of anaesthesia with the ProSeal (R) laryngeal mask airway during pressure support ventilation. Methods: Sixty healthy adults undergoing peripheral musculo-skeletal surgery were randomized for maintenance with sevoflurane end-tidal 29%, isoflurane end-tidal 1.1% or propofol 6 mg kg(-1) h(-1) in oxygen 33% and air. Pressure support ventilation comprised positive end-expiratory pressure set at 5 cmH(2)O, and pressure support set 5 cmH(2)O above positive end-expiratory pressure. Pressure support was initiated when inspiration produced a 2 cmH(2)O reduction in airway pressure. A blinded observer recorded cardiorespiratory variables (heart rate, mean blood pressure, oxygen saturation, air-way occlusion pressure, respiratory rate, expired tidal volume, expired minute volume and end-tidal CO2), adverse events and emergence times. Results: Respiratory rate and minute volume were 10-21% lower, and end-tidal CO2 6-11% higher with the propofol group compared with the sevoflurane or isoflurane groups, but otherwise cardiorespiratory variables were similar among groups. No adverse events occurred in any group. Emergence times were longer with the propofol group compared with the sevoflurane or isoflurane groups (10 vs. 7 vs. 7 min). Conclusion: Lung ventilation is less effective and emergence times are longer with propofol than sevoflurane or isoflurane for maintenance of anaesthesia during pressure support ventilation with the ProSeal (R) laryngeal mask airway. However, these differences are small and of doubtful clinical importance.
Resumo:
The Laryngeal Mask Airway is a reusable device for maintaining the patency of a patient's airway during general anaesthesia. The device can be reused after it has been cleaned and sterilized. Protein contamination of medical instruments is a concern and has been found to occur despite standard sterilization techniques. The reason for the concern relates to the possibility of the transmission of prions and the risk of developing a neurodegenerative disorder such as Creutzveldt-Jacob disease. The purpose of this study was to quantify the amount of protein contamination that occurs, and to relate this to the number of times the Laryngeal Mask Airway has been used. Fifty previously used Classic Laryngeal Masks were collected after routine sterilization and packaging. The devices were immersed in protein detecting stain and then visual inspection performed to assess the degree and distribution of the staining. The researcher was blinded to the number of times the Laryngeal Mask Airway had been used. Linear regression analysis of the degrees of staining of the airway revealed that protein contamination occurs after the first use of the device and this increases with each subsequent use. This finding highlights the concern that the currently used cleaning and sterilization methods do not prevent the accumulation of proteinaceous material on Laryngeal Mask Airways. Consideration should be given to the search for more efficient cleaning and sterilization techniques or the use of disposable devices.
Resumo:
Objective-We previously demonstrated that upregulation of intermediate-conductance Ca2+ -activated K+ channels (KCa 3.1) is necessary for mitogen-induced phenotypic modulation in isolated porcine coronary smooth muscle cells (SMCs). The objective of the present study was to determine the role of KCa3.1 in the regulation of coronary SMC phenotypic modulation in vivo using a swine model of postangioplasty restenosis. Methods and Results-Balloon angioplasty was performed on coronary arteries of swine using either noncoated or balloons coated with the specific KCa3.1 blocker TRAM-34. Expression of KCa3.1, c-jun, c-fos, repressor element-1 silencing transcription factor (REST), smooth muscle myosin heavy chain (SMMHC), and myocardin was measured using qRT-PCR in isolated medial cells 2 hours and 2 days postangioplasty. KCa3.1, c-jun, and c-fos mRNA levels were increased 2 hours postangioplasty, whereas REST expression decreased. SMMHC expression was unchanged at 2 hours, but decreased 2 days postangioplasty. Use of TRAM-34 coated balloons prevented KCa3.1 upregulation and REST downregulation at 2 hours, SMMHC and myocardin downregulation at 2 days, and attenuated subsequent restenosis 14 and 28 days postangioplasty. Immunohistochemical analysis demonstrated corresponding changes at the protein level. Conclusion-Blockade of KCa3.1 by delivery of TRAM-34 via balloon catheter prevented smooth muscle phenotypic modulation and limited subsequent restenosis. © 2008 American Heart Association, Inc.