974 resultados para hot-air balloons


Relevância:

30.00% 30.00%

Publicador:

Resumo:

There are many physical factors that can affect the self-heating rate of coal. The presence of seam gas has often been referred to as inhibiting coal self-heating due to the limited access of oxidation sites created by the presence of the gas adsorbed on the coal pores. Similarly, the presence of bed moisture in the coal also acts as an inhibitor of oxidation by blocking access of air into the pores. Gas drainage of a coal seam prior to mining removes both gas and moisture from the seam. Bulk coal self-heating tests in a two-metre column on both gassy, as-mined and gas-drained, dried high volatile bituminous coal show that removal of gas and moisture from the coal accelerates the rate of self-heating to thermal runaway from 8.5 days to 4.25 days, from a start temperature of 30°C, with an airflow of 0.25 L/min. The corresponding gas evolution pattern for each of these situations is different. Therefore, it is necessary to take this change in coal condition into consideration when developing a spontaneous combustion management plan.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A study on heat pump thermodynamic characteristics has been made in the laboratory on a specially designed and instrumented air to water heat pump system. The design, using refrigerant R12, was based on the requirement to produce domestic hot water at a temperature of about 50 °C and was assembled in the laboratory. All the experimental data were fed to a microcomputer and stored on disk automatically from appropriate transducers via amplifier and 16 channel analogue to digital converters. The measurements taken were R12 pressures and temperatures, water and R12 mass flow rates, air speed, fan and compressor input powers, water and air inlet and outlet temperatures, wet and dry bulb temperatures. The time interval between the observations could be varied. The results showed, as expected, that the COP was higher at higher air inlet temperatures and at lower hot water output temperatures. The optimum air speed was found to be at a speed when the fan input power was about 4% of the condenser heat output. It was also found that the hot water can be produced at a temperature higher than the appropriate R12 condensing temperature corresponding to condensing pressure. This was achieved by condenser design to take advantage of discharge superheat and by further heating the water using heat recovery from the compressor. Of the input power to the compressor, typically about 85% was transferred to the refrigerant, 50 % by the compression work and 35% due to the heating of the refrigerant by the cylinder wall, and the remaining 15% (of the input power) was rejected to the cooling medium. The evaporator effectiveness was found to be about 75% and sensitive to the air speed. Using the data collected, a steady state computer model was developed. For given input conditions s air inlet temperature, air speed, the degree of suction superheat , water inlet and outlet temperatures; the model is capable of predicting the refrigerant cycle, compressor efficiency, evaporator effectiveness, condenser water flow rate and system Cop.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Evaporative pads are frequently used for the cooling of greenhouses. However, a drawback of this method is the consumption of freshwater. In this paper it is shown, both theoretically and through a practical example, that effective evaporative cooling can be achieved using seawater in place of fresh water. The advantages and drawbacks of using seawater are discussed more generally. In climates that are both hot and humid, evaporative systems cannot always provide sufficient cooling, with the result that cultivation often has to be halted during the hottest months of the year. To overcome this, we propose a concept in which a desiccant pad is used to dehumidify the air before it enters the evaporative pad. The desiccant pad is supplied with a hygroscopic liquid that is regenerated by the energy of the sun. The performance of this concept has been modelled and the properties of various liquids have been compared. An attractive option is to obtain the liquid from seawater itself, given that seawater contains hygroscopic salts such as magnesium chloride. Preliminary experiments are reported in which magnesium chloride solution has been regenerated beneath a solar simulator.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Humidifying the air inside a hot holding cabinet can greatly extend the holding time for hot foods by retarding the quality degradation of the food due to moisture loss. Not all cabinets are equally effective in maintaining temperature and humidity. A rudimentary understanding of how heat and moisture are transferred to the food will help operators select the cabinet that best meets operation’s needs. The authors address what works and why.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The research vessel and supply icebreaker POLARSTERN is the flagship of the Alfred-Wegener-Institut in Bremerhaven (Germany) and one of the infrastructural pillars of German Antarctic research. Since its commissioning in 1982, POLARSTERN has conducted 30 campaigns to Antarctica (157 legs, mostly austral summer), and 29 to the Arctic (94 legs, northern summer). Usually, POLARSTERN is more than 300 days per year in operation and crosses the Atlantic Ocean in a meridional section twice a year. The first radiosonde on POLARSTERN was released on the 29th of December 1982, two days after POLARSTERN started on its maiden voyage to the Antarctic. And these daily soundings have continued up to the present. Due to the fact that POLARSTERN has reliably and regularly been providing upper air observations from data sparse regions (oceans and polar regions), the radiosonde data are of special value for researchers and weather forecast services alike. In the course of 30 years (1982-12-29 to 2012-11-25) a total of 12378 radiosonde balloons were started on POLARSTERN. All radiosonde data can now be found here. Each dataset contains the directly measured parameters air temperature, relative humidity and air pressure, and the derived altitude, wind direction and wind speed. 432 datasets additionally contain ozone measurements.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The structure of a turbulent non-premixed flame of a biogas fuel in a hot and diluted coflow mimicking moderate and intense low dilution (MILD) combustion is studied numerically. Biogas fuel is obtained by dilution of Dutch natural gas (DNG) with CO2. The results of biogas combustion are compared with those of DNG combustion in the Delft Jet-in-Hot-Coflow (DJHC) burner. New experimental measurements of lift-off height and of velocity and temperature statistics have been made to provide a database for evaluating the capability of numerical methods in predicting the flame structure. Compared to the lift-off height of the DNG flame, addition of 30 % carbon dioxide to the fuel increases the lift-off height by less than 15 %. Numerical simulations are conducted by solving the RANS equations using Reynolds stress model (RSM) as turbulence model in combination with EDC (Eddy Dissipation Concept) and transported probability density function (PDF) as turbulence-chemistry interaction models. The DRM19 reduced mechanism is used as chemical kinetics with the EDC model. A tabulated chemistry model based on the Flamelet Generated Manifold (FGM) is adopted in the PDF method. The table describes a non-adiabatic three stream mixing problem between fuel, coflow and ambient air based on igniting counterflow diffusion flamelets. The results show that the EDC/DRM19 and PDF/FGM models predict the experimentally observed decreasing trend of lift-off height with increase of the coflow temperature. Although more detailed chemistry is used with EDC, the temperature fluctuations at the coflow inlet (approximately 100K) cannot be included resulting in a significant overprediction of the flame temperature. Only the PDF modeling results with temperature fluctuations predict the correct mean temperature profiles of the biogas case and compare well with the experimental temperature distributions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This study was conducted to assess the effect of air-dried Moringa stenopetala leaf (MSL) supplementation on carcass components and meat quality in Arsi-Bale goats. A total of 24 yearling goats with initial body weight of 13.6+/-0.25 kg were randomly divided into four treatments with six goats each. All goats received a basal diet of natural grass hay ad libitum and 340 g head^(−1) d^(−1) concentrate. The treatment diets contain a control diet without supplementation (T1) and diets supplemented with MSL at a rate of 120 g head^(−1) d^(−1) (T2), 170 g head^(−1) d^(−1) (T3) and 220 g head^(−1) d^(−1) (T4). The results indicated that the average slaughter weight of goats reared on T3 and T4 was 18.2 and 18.3 kg, respectively, being (P<0.05) higher than those of T1 (15.8 kg) and T2 (16.5 kg). Goats fed on T3 and T4 diets had higher (P<0.05) daily weight gain compared with those of T1 and T2. The hot carcass weight in goats reared on T3 and T4 diets was 6.40 and 7.30 kg, respectively, being (P<0.05) higher than those of T1 (4.81 kg) and T2 (5.06 kg). Goats reared on T4 had higher (P<0.05) dressing percentage than those reared in other treatment diets. The rib-eye area in goats reared on T2, T3 and T4 diets was higher (P<0.05) than those of T1. The protein content of the meat in goats reared on T3 and T4 was 24.0 and 26.4%, respectively being significantly higher than those of T1 (19.1%) and T2 (20.1%). In conclusion, the supplementation of MSL to natural grass hay improved the weight gain and carcass parts of Arsi-Bale goats indicating Moringa leaves as alternative protein supplements to poor quality forages.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In recent years, we have seen an improvement of existing facilities in dwellings in Portugal. Within the heat pumps systems, there is a special type known as direct expansion heat pump assisted by Solar Collector (DX-SAHP). It was calculate the SPF indicator for 30 regions of Portugal. It was analyses the potential of reductions of CO2 and primary energy use for the retrofitting of DHW preparation systems. It was found that the performances of this type of equipment are benefiting from the Portuguese climate conditions, especially in the South and in the Autonomous Regions. Best SPF was obtained for Beja. It was found in all regions of the high potential for reducing CO2 emissions and verifying a potential significant reduction of primary energy consumption.