997 resultados para heat balance
Resumo:
The study analyzes the trend in frequency of adults who drive under the influence of alcohol in major Brazilian cities after the passing of laws, which prohibit drunk driving. Data from the Surveillance System for Risk and Protective Factors for Chronic Diseases by Telephone Survey (VIGITEL) between 2007 and 2013 were analyzed. The frequency of adults who drove after abusive alcohol consumption was reduced by 45.0% during this period (2.0% in 2007 to 1.1% in 2013). Between 2007 and 2008 (-0.5%) and between 2012 and 2013 (-0.5%), significant reductions were observed in the years immediately after the publication of these laws that prohibit drunk driving. These improvements towards the control of drunk driving show a change in the Brazilian population’s lifestyle.
Resumo:
This paper presents a computational tool (PHEx) developed in Excel VBA for solving sizing and rating design problems involving Chevron type plate heat exchangers (PHE) with 1-pass-1-pass configuration. The rating methodology procedure used in the program is outlined, and a case study is presented with the purpose to show how the program can be used to develop sensitivity analysis to several dimensional parameters of PHE and to observe their effect on transferred heat and pressure drop.
Resumo:
Purpose: To investigate whether standard X-ray acquisition factors for orbital radiographs are suitable for the detection of ferromagnetic intra-ocular foreign bodies in patients undergoing MRI. Method: 35 observers, at varied levels of education in radiography, attending a European Dose Optimisation EURASMUS Summer School were asked to score 24 images of varying acquisition factors against a clinical standard (reference image) using two alternative forced choice. The observers were provided with 12 questions and a 5 point Likert scale. Statistical tests were used to validate the scale, and scale reliability was also measured. The images which scored equal to, or better than, the reference image (36) were ranked alongside their corresponding effective dose (E), the image with the lowest dose equal to or better than the reference is considered the new optimum acquisition factors. Results: Four images emerged as equal to, or better than, the reference in terms of image quality. The images were then ranked in order of E. Only one image that scored the same as the reference had a lower dose. The reference image had a mean E of 3.31μSv, the image that scored the same had an E of 1.8μSv. Conclusion: Against the current clinical standard exposure factors of 70kVp, 20mAs and the use of an anti- scatter grid, one image proved to have a lower E whilst maintaining the same level of image quality and lesion visibility. It is suggested that the new exposure factors should be 60kVp, 20mAs and still include the use of an anti-scatter grid.
Resumo:
The differentiation of non-integer order has its origin in the seventeenth century, but only in the last two decades appeared the first applications in the area of control theory. In this paper we consider the study of a heat diffusion system based on the application of the fractional calculus concepts. In this perspective, several control methodologies are investigated namely the fractional PID and the Smith predictor. Extensive simulations are presented assessing the performance of the proposed fractional-order algorithms.
Resumo:
Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química
Resumo:
Background: Brown adipose tissue (BAT) plays an important role in whole body metabolism and could potentially mediate weight gain and insulin sensitivity. Although some imaging techniques allow BAT detection, there are currently no viable methods for continuous acquisition of BAT energy expenditure. We present a non-invasive technique for long term monitoring of BAT metabolism using microwave radiometry. Methods: A multilayer 3D computational model was created in HFSS™ with 1.5 mm skin, 3-10 mm subcutaneous fat, 200 mm muscle and a BAT region (2-6 cm3) located between fat and muscle. Based on this model, a log-spiral antenna was designed and optimized to maximize reception of thermal emissions from the target (BAT). The power absorption patterns calculated in HFSS™ were combined with simulated thermal distributions computed in COMSOL® to predict radiometric signal measured from an ultra-low-noise microwave radiometer. The power received by the antenna was characterized as a function of different levels of BAT metabolism under cold and noradrenergic stimulation. Results: The optimized frequency band was 1.5-2.2 GHz, with averaged antenna efficiency of 19%. The simulated power received by the radiometric antenna increased 2-9 mdBm (noradrenergic stimulus) and 4-15 mdBm (cold stimulus) corresponding to increased 15-fold BAT metabolism. Conclusions: Results demonstrated the ability to detect thermal radiation from small volumes (2-6 cm3) of BAT located up to 12 mm deep and to monitor small changes (0.5°C) in BAT metabolism. As such, the developed miniature radiometric antenna sensor appears suitable for non-invasive long term monitoring of BAT metabolism.
Resumo:
The concept of differentiation and integration to non-integer order has its origins in the seventeen century. However, only in the second-half of the twenty century appeared the first applications related to the area of control theory. In this paper we consider the study of a heat diffusion system based on the application of the fractional calculus concepts. In this perspective, several control methodologies are investigated and compared. Simulations are presented assessing the performance of the proposed fractional-order algorithms.
Resumo:
Immune response against hepatitis B vaccine (CLB 3mg) was evaluated in 59 hemodialysis patients and 20 occupational risk personnel. Seroconversion was induced in 52.5% and 70.0% respectively. Twelve months after the first dose, 37.5% of patients and 60.0% of occupational risk personnel had detectable anti-HBs level. Antibody level was expressed in sample ratio units (SRU). Considering only the responders, in the patients group 38.7% had a low anti-HBs response (2.1-9.9 SRU) 32.3% a medium response (10-99.9 SRU) and 29.0% a high response (>100 SRU) while in occupational risk personnel these values were 14.3%, 64.3% and 21.4% respectively. The authors suggest the use of HBV vaccines with more elevated HBsAg concentration or a reinforced immunization schedule to improve the anti-HBs response not only for patients but also for healthy persons.
Resumo:
The aim of this study is to optimize the heat flow through the pultrusion die assembly system on the manufacturing process of a specific glass-fiber reinforced polymer (GFRP) pultrusion profile. The control of heat flow and its distribution through whole die assembly system is of vital importance in optimizing the actual GFRP pultrusion process. Through mathematical modeling of heating-die process, by means of Finite Element Analysis (FEA) program, an optimum heater selection, die position and temperature control was achieved. The thermal environment within the die was critically modeled relative not only to the applied heat sources, but also to the conductive and convective losses, as well as the thermal contribution arising from the exothermic reaction of resin matrix as it cures or polymerizes from the liquid to solid condition. Numerical simulation was validated with basis on thermographic measurements carried out on key points along the die during pultrusion process.
Resumo:
Pultrusion is an industrial process used to produce glass fibers reinforced polymers profiles. These materials are worldwide used when performing characteristics, such as great electrical and magnetic insulation, high strength to weight ratio, corrosion and weather resistance, long service life and minimal maintenance are required. In this study, we present the results of the modelling and simulation of heat flow through a pultrusion die by means of Finite Element Analysis (FEA). The numerical simulation was calibrated based on temperature profiles computed from thermographic measurements carried out during pultrusion manufacturing process. Obtained results have shown a maximum deviation of 7%, which is considered to be acceptable for this type of analysis, and is below to the 10% value, previously specified as maximum deviation. © 2011, Advanced Engineering Solutions.
Resumo:
The computations performed by the brain ultimately rely on the functional connectivity between neurons embedded in complex networks. It is well known that the neuronal connections, the synapses, are plastic, i.e. the contribution of each presynaptic neuron to the firing of a postsynaptic neuron can be independently adjusted. The modulation of effective synaptic strength can occur on time scales that range from tens or hundreds of milliseconds, to tens of minutes or hours, to days, and may involve pre- and/or post-synaptic modifications. The collection of these mechanisms is generally believed to underlie learning and memory and, hence, it is fundamental to understand their consequences in the behavior of neurons.(...)
Resumo:
Trabalho Final de Mestrado para obtenção do grau de Mestre em Engenharia Mecânica
Resumo:
Dissertação apresentada na Faculdade de Ciências e Tecnologia da Universidade Nova de Lisboa para obtenção do grau de Mestre em Engenharia do Ambiente, perfil de Engenharia Ecológica
Resumo:
Comunicação apresentada na "European Sociological Association Conference" em Lisboa de 2 a 5 de Setembro de 2009.
Resumo:
A presente dissertação centrou-se no estudo técnico-económico de dois cenários futuros para a continuação de fornecimento de energia térmica a um complexo de piscinas existente na região do vale do Tâmega. Neste momento a central de cogeração existente excedeu a sua licença de utilização e necessita de ser substituída. Os dois cenários em estudo são a compra de uma nova caldeira, a gás natural, para suprir as necessidades térmicas da caldeira existente a fuelóleo, ou o uso de um sistema de cogeração compacto que poderá estar disponível numa empresa do grupo. No primeiro cenário o investimento envolvido é cerca de 456 640 € sem proveitos de outra ordem para além dos requisitos térmicos, mas no segundo cenário os resultados são bem diferentes, mesmo que tenha de ser realizado o investimento de 1 000 000 € na instalação. Para este cenário foi efetuado um levantamento da legislação nacional no que toca à cogeração, recolheram-se dados do edifício como: horas de funcionamento, número de utentes, consumos de energia elétrica, térmica, água, temperatura da água das piscinas, temperatura do ar da nave, assim como as principais características da instalação de cogeração compacta. Com esta informação realizou-se o balanço de massa e energia e criou-se um modelo da nova instalação em software de modelação processual (Aspen Plus® da AspenTech). Os rendimentos térmico e elétrico obtidos da nova central de cogeração compacta foram, respetivamente, de 38,1% e 39,8%, com uma percentagem de perdas de 12,5% o que determinou um rendimento global de 78%. A avaliação da poupança de energia primária para esta instalação de cogeração compacta foi de 19,6 % o que permitiu concluir que é de elevada eficiência. O modelo criado permitiu compreender as necessidades energéticas, determinar alguns custos associados ao processo e simular o funcionamento da unidade com diferentes temperaturas de ar ambiente (cenários de verão e inverno com temperaturas médias de 20ºC e 5ºC). Os resultados revelaram uma diminuição de 1,14 €/h no custo da electricidade e um aumento do consumo de gás natural de 62,47 €/h durante o período mais frio no inverno devido ao aumento das perdas provocadas pela diminuição da temperatura exterior. Com esta nova unidade de cogeração compacta a poupança total anual pode ser, em média, de 267 780 € admitindo um valor para a manutenção de 97 698 €/ano. Se assim for, o projeto apresenta um retorno do investimento ao fim de 5 anos, com um VAL de 1 030 430 € e uma taxa interna de rentabilidade (TIR) de 14% (positiva, se se considerar a taxa de atualização do investimento de 3% para 15 anos de vida). Apesar do custo inicial ser elevado, os parâmetros económicos mostram que o projeto tem viabilidade económica e dará lucro durante cerca de 9 anos.