939 resultados para finger photoplethysmography
Resumo:
Dissertation to obtain the Doctoral degree in Physics Engineering
Resumo:
Dissertação para obtenção do Grau de Mestre em Engenharia Electrotécnica e de Computadores
Resumo:
Dissertation submitted in Faculdade de Ciências e Tecnologia of Universidade Nova de Lisboa for the degree of Master of Biomedical Engineering
Resumo:
The effects of high and low-protein diets on the structure of the jejunal mucosa were studied in Schistosoma mansoni infected mice (morphology and histomorphometry). Weaning male albino mice were infected with 80 cercariae, fed with high (20%) or low-protein (5%) diets and compared to uninfected controls under the same conditions. Mice were sacrificed 12 weeks after infection. Animals submitted to a low-protein diet showed lower weight curves, mainly when infected. In the jejunal mucosa, finger-like villi were the predominant pattern among uninfected high-protein fed animals, while the infected ones showed leaf-shaped and flattened villi in most cases. Undernourished infected mice had 65.7% leaf-shaped villi. A significant increase in the number of goblet cells was seen in infected mice. A decrease in the number of absorptive cells was detected in undernourished mice, particularly in infected ones.
Resumo:
Dissertação para a obtenção do Grau de Mestre em Engenharia Biomédica
Resumo:
A thermal Energy Storage Unit (ESU) could be used to attenuate inherent temperature fluctuations of a cold finger, either from a cryocooler working or due to sudden income heat bursts. An ESU directly coupled to the cold source acts as a thermal buffer temporarily increasing its cooling capacity and providing a better thermal stability of the cold finger (“Power Booster mode”). The energy storage units presented here use an enthalpy reservoir based on the high latent heat of the liquid-vapour transition of neon in the temperature range 38 - 44 K to store up to 900 J, and that uses a 6 liters expansion volume at RT in order to work as a closed system. Experimental results in the power booster mode will be described: in this case, the liquid neon cell was directly coupled to the cold finger of the working cryocooler, its volume (12 cm3) allowing it to store 450 J at around 40 K. 10 W heat bursts were applied, leading to liquid evaporation, with quite reduced temperature changes. The liquid neon reservoir can also work as a temporary cold source to be used after stopping the cryocooler, allowing for a vibration-free environment. In this case the enthalpy reservoir implemented (24 cm3) was linked to the cryocooler cold finger through a gas gap heat switch for thermal coupling/decoupling of the cold finger. We will show that, by controlling the enthalpy reservoir’s pressure, 900 J can be stored at a constant temperature of 40 K as in a triple-point ESU.
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices, implemented as a software,describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
Cryocoolers have been progressively replacing the use of the stored cryogens in cryogenic chains used for detector cooling, thanks to their higher and higher reliability. However, the mechanical vibrations, the electromagnetic interferences and the temperature fluctuations inherent to their functioning could reduce the sensor’s sensitivity. In order to minimize this problem, compact thermal energy storage units (ESU) are studied, devices able to store thermal energy without significant temperature increase. These devices can be used as a temporary cold source making it possible to turn the cryocooler OFF providing a proper environment for the sensor. A heat switch is responsible for the thermal decoupling of the ESU from the cryocooler’s temperature that increases when turned OFF. In this work, several prototypes working around 40 K were designed, built and characterized. They consist in a low temperature cell that contains the liquid neon connected to an expansion volume at room temperature for gas storage during the liquid evaporation phase. To turn this system insensitive to the gravity direction, the liquid is retained in the low temperature cell by capillary effect in a porous material. Thanks to pressure regulation of the liquid neon bath, 900 J were stored at 40K. The higher latent heat of the liquid and the inexistence of triple point transitions at 40 K turn the pressure control during the evaporation a versatile and compact alternative to an ESU working at the triple point transitions. A quite compact second prototype ESU directly connected to the cryocooler cold finger was tested as a temperature stabilizer. This device was able to stabilize the cryocooler temperature ((≈ 40K ±1 K) despite sudden heat bursts corresponding to twice the cooling power of the cryocooler. This thesis describes the construction of these devices as well as the tests performed. It is also shown that the thermal model developed to predict the thermal behaviour of these devices,implemented as a software, describes quite well the experimental results. Solutions to improve these devices are also proposed.
Resumo:
INTRODUCTION: Human serofrequency of antibodies against Taenia solium antigens was determined and risk factors for cysticercosis transmission were identified. METHODS: Individuals (n=878) from periurban and rural locations of Lages, SC, were interviewed to gather demographic, sanitary and health information. Interviews and blood sample collections by finger prick on Whatman filter paper were performed from August 2004 to May 2005. Observation determined that 850 samples were suitable for analysis and were tested by ELISA using vesicular fluid of Taenia crassiceps heterologous antigen. To ensure the reliability of the results, 77 samples of the dried blood were matched with sera. The reactive samples were submitted to a serum confirmatory immunoblot (IB) test using purified Taenia crassiceps glycoproteins. RESULTS: The ELISA results for the dried blood and serum samples were statistically consistent. ELISA was positive in 186 (21.9%) out of 850 individuals. A group of 213 individuals were asked to collect vein blood for IB (186 with positive result in ELISA and 27 with inappropriate whole blood samples) and 130 attended the request. The IB was positive in 29 (3.4%) out of 850 individuals. A significant correlation (p = 0.0364) was determined among individuals who tested positive in the IB assay who practiced both pig rearing and kitchen gardening. CONCLUSIONS: ELISA with dried blood eluted from filter paper was suitable for cysticercosis population surveys. In Lages, human infection was associated with pig rearing and kitchen gardening. The prevalence index was compatible with other Latin American endemic areas.
Resumo:
We present an uncommon case of a 3-year-old boy with a finger sucking habit who developed dystrophic calcification in his left thumb. Two years after excision, there was no recurrence, and the thumb retained full range of motion. We also discuss its probable pathogenesis and present a brief review of the literature about orthopedic complications in the hand due to this habit.
Resumo:
A rare case of thumb metastasis from small cell lung cancer is presented. The patient underwent local radiotherapy with complete palliation of symptoms. She died 4 months later with disseminated disease. Considerations about incidence, treatment, and physiopathology of this kind of dissemination are made. Conservative treatment of finger metastasis with radiation may be considered due to the poor outcome of these patients.
Resumo:
PURPOSE: To measure the thickness of adductor pollicis muscle in healthy adults. This measurement will be used as a nutritional anthropometric parameter in further studies. SUBJECTS AND METHOD: Four hundred and twenty-one healthy adults were studied, 209 men and 212 women, with ages ranging from 18 to 87 years, living in Rio de Janeiro. The adductor pollicis muscle was also studied in the human anatomy lab as well as in normal healthy volunteers using CAT scans and nuclear magnetic resonance imaging to ensure that only the adductor pollicis was included in measurement of muscle thickness with a Lange caliper. To standardize the measurement, the methodology was detailed, with subjects sitting with the dominant hand dangling over the homolateral thigh and the elbow bent at approximately a 90° angle. The Lange caliper was applied at a pressure of 10 g/mm², pinching the adductor pollicis muscle at the vertex of an imaginary angle between the thumb and the index finger. The average of 3 consecutive measurements was considered to be the muscle thickness. RESULTS: This study provides the first estimates of adductor pollicis thickness in normal healthy subjects as an anthropometric parameter. The normal values in the dominant hand for men were 12.5 ± 2.8 mm (mean ± SD), median 12 mm, and for women were 10.5 ± 2.3 mm, median 10 mm.
Resumo:
Several studies have shown that people with disabilities benefit substantially from access to a means of independent mobility and assistive technology. Researchers are using technology originally developed for mobile robots to create easier to use wheelchairs. With this kind of technology people with disabilities can gain a degree of independence in performing daily life activities. In this work a computer vision system is presented, able to drive a wheelchair with a minimum number of finger commands. The user hand is detected and segmented with the use of a kinect camera, and fingertips are extracted from depth information, and used as wheelchair commands.
Resumo:
[Excerpt] Synchronization of periodic movements like side-by-side walking [7] is frequently modeled by coupled oscillators [5] and the coupling strength is defined quantitatively [3]. In contrast, in most studies on sensorimotor synchronization (SMS), simple movements like finger taps are synchronized with simple stimuli like metronomes [4]. While the latter paradigm simplifies matters and allows for the assessment of the relative weights of sensory modalities through systematic variation of the stimuli [1], it might lack ecological validity. Conversely, using more complex movements and stimuli might complicate the specification of mechanisms underlying coupling. We merged the positive aspects of both approaches to study the contribution of auditory and visual information on synchronization during side-by-side walking. As stimuli, we used Point Light Walkers (PLWs) and auralized steps sound; both were constructed from previously captured walking individuals [2][6]. PLWs were retro-projected on a screen and matched according to gender, hip height, and velocity. The participant walked for 7.20m side by side with 1) a PLW, 2) steps sound, or 3) both displayed in temporal congruence. Instruction to participants was to synchronize with the available stimuli. [...]
Resumo:
O presente trabalho teve como objetivo avaliar a qualidade pós-colheita de frutos de cubiu (Solanum sessiliflorum) durante o amadurecimento após o tratamento com Etefon. Frutos das variedades Santa Luzia e Thais no estádio verde-maduro foram coletados, lavados e pulverizados até o completo molhamento com 1000 mg L-1 de Etefon e o controle com água. A cada três dias, durante 12 dias foram realizadas análises da firmeza do pericarpo, pH, teor de sólidos solúveis totais, acidez total titulável (ATT), umidade e cinzas. Foi avaliada a liberação de C0(2) e etileno diariamente durante 12 dias, conjuntamente com a perda de matéria fresca e evolução da cor, a cada três dias, sempre no mesmo grupo de frutos. Foi empregado o delineamento experimental inteiramente casualizado. Os dados foram submetidos à análise de variância e análise de regressão. Ocorreu perda de firmeza do pericarpo dos frutos com o tempo de armazenamento pós-colheita, com diminuição do pH, aumento da ATT e perda da matéria fresca. A aplicação de Etefon promoveu poucas mudanças na qualidade interna dos frutos, porém foi eficiente no desverdecimento da casca, o que pode ser verificado pelos menores valores do ângulo de cor e maiores da cromaticidade e luminosidade. O comportamento da respiração e produção de etileno aponta para um modelo de amadurecimento não climatérico.