968 resultados para endoscopic ultrasound
Resumo:
Background: Thus far, the correlation of noninvasive markers with endoscopic activity in ulcerative colitis (UC) according to the modified Baron Index is unknown. We aimed to evaluate the correlation between endoscopic activity and fecal calprotectin (FC), C-reactive protein (CRP), blood leukocytes, and the Lichtiger Index (clinical score). Methods: UC patients undergoing complete colonoscopy were prospectively enrolled and scored clinically and endoscopically in an independent fashion. Fecal and blood samples were analyzed in UC patients and controls. Results: We enrolled 228 UC patients and 52 controls. Endoscopic disease activity correlated best with FC (Spearman's rank correlation coefficient r = 0.821), followed by the Lichtiger Index (r = 0.682), CRP (r = 0.556), and leukocytes (r = 0.401). FC was the only marker discriminating between different grades of endoscopic activity (grade 0, 20}11 mg/g; grade 1, 44}34 mg/g; grade 2, 111}74 mg/g; grade 3, 330}332 mg/g; grade 4, 659}319 mg/g; P = 0.0018 for discriminating grade 0 vs. 1 and P < 0.001 for discriminating all other grades). FC had the highest overall accuracy (91%) to detect endoscopically active disease (modified Baron Index _2), followed by the Lichtiger Index of _4 (77%), CRP larger than 5 mg/L (69%) and blood leukocytosis (58%). Conclusions: FC better correlated with the endoscopic disease activity than clinical activity, CRP, and blood leukocytes. The strong correlation with endoscopic disease activity suggests that FC represents a useful biomarker for noninvasive monitoring of disease activity in UC patients.
Extensive (8 to 12 cm2) noncircumferential endoscopic mucosal resection for early esophageal cancer.
Resumo:
Background: Endoscopic mucosal resection (EMR) is an appealing method for treating intramucosal esophageal cancer but must comply with the following stringent requirements: proper preoperative staging, complete resection of the lesion, obtaining a resected specimen for histologic analysis of safety margins, and squamous reepithelialization without stricture formation. Methods: A rigid esophagoscope was created to resect up to 12 cm(2) of esophageal mucosa in a single specimen and at a constant depth through the submucosa. Under visual control, the esophageal mucosa is sucked into a transparent window and resected with a thin diathermy wire loop in 10 seconds. After extensive preclinical studies in a sheep model, this article reports our early experience in humans. Results: Twenty-one hemi-circumferential EMRs were performed for 11 dysplastic Barrett's esophagi and 10 early squamous cell carcinomas with no perforation, one hemorrhage controlled by embolization of the left gastric artery, and one incomplete resection. Deep safety margins were clear in 19 of 21 resected specimens (2 patients, unfit for operations, had submucosal invasion of squamous cell carcinoma and adenocarcinoma, respectively). Lateral margins were not clear by definition in 7 circumferential Barrett's esophagi, but were clear in 4 incomplete Barrett's esophagi and 10 early squamous cell carcinomas. Conclusions: Large EMRs of 12 cm(2) can safely be performed at the submucosal level in the esophagus. Although feasible in one session, circumferential EMR in humans is not yet advisable because of the risk of stricture formation during the healing phase. The rate of complications of this series of 21 EMRs in humans is acceptable. (Ann Thorac Surg 2010; 89: S2151-5) (C) 2010 by The Society of Thoracic Surgeons
Resumo:
The present study describes some of the applications of ultrasound in bone surgery, based on the presentation of two clinical cases. The Piezosurgery® ultrasound device was used (Tecnología Mectron Medical, Carasco, Italy). In one case the instrument was used to harvest a chin bone graft for placement in a bone defect at level 1.2, while in the other case a bony window osteotomy was made in the external wall of the maxillary sinus, in the context of a sinus membrane lift procedure. The Piezosurgery® device produces specific ultrasound frequency modulation (25-29 kHz), and has been designed to secure increased precision in application to bone surgery. This instrument produces selective sectioning of the mineralized bone structures, and causes less intra- and postoperative bleeding. One of the advantages of the Piezosurgery® device is that it can be used for maxillary sinus lift procedures in dental implant placement. In this context it considerably lessens the risk of sinus mucosa laceration by preparing the bony window in the external wall of the upper maxilla, and can be used to complete the lifting maneuver. The use of ultrasound in application to hard tissues can be regarded as a slow technique compared with the conventional rotary instruments, since it requires special surgical skill and involves a certain learning curve.
Complications of different ventilation strategies in endoscopic laryngeal surgery: a 10-year review.
Resumo:
BACKGROUND: Spontaneous ventilation, mechanical controlled ventilation, apneic intermittent ventilation, and jet ventilation are commonly used during interventional suspension microlaryngoscopy. The aim of this study was to investigate specific complications of each technique, with special emphasis on transtracheal and transglottal jet ventilation. METHODS: The authors performed a retrospective single-institution analysis of a case series of 1,093 microlaryngoscopies performed in 661 patients between January 1994 and January 2004. Data were collected from two separate prospective databases. Feasibility and complications encountered with each technique of ventilation were analyzed as main outcome measures. RESULTS: During 1,093 suspension microlaryngoscopies, ventilation was supplied by mechanical controlled ventilation via small endotracheal tubes (n = 200), intermittent apneic ventilation (n = 159), transtracheal jet ventilation (n = 265), or transglottal jet ventilation (n = 469). Twenty-nine minor and 4 major complications occurred. Seventy-five percent of the patients with major events had an American Society of Anesthesiologists physical status classification of III. Five laryngospasms were observed with apneic intermittent ventilation. All other 24 complications (including 7 barotrauma) occurred during jet ventilation. Transtracheal jet ventilation was associated with a significantly higher complication rate than transglottal jet ventilation (P < 0.0001; odds ratio, 4.3 [95% confidence interval, 1.9-10.0]). All severe complications were related to barotraumas resulting from airway outflow obstruction during jet ventilation, most often laryngospasms. CONCLUSIONS: The use of a transtracheal cannula was the major independent risk factor for complications during jet ventilation for interventional microlaryngoscopy. The anesthetist's vigilance in clinically detecting and preventing outflow airway obstruction remains the best prevention of barotrauma during subglottic jet ventilation.
Resumo:
For the detection and management of osteoporosis and osteoporosis-related fractures, quantitative ultrasound (QUS) is emerging as a relatively low-cost and readily accessible alternative to dual-energy X-ray absorptiometry (DXA) measurement of bone mineral density (BMD) in certain circumstances. The following is a brief, but thorough review of the existing literature with respect to the use of QUS in 6 settings: 1) assessing fragility fracture risk; 2) diagnosing osteoporosis; 3) initiating osteoporosis treatment; 4) monitoring osteoporosis treatment; 5) osteoporosis case finding; and 6) quality assurance and control. Many QUS devices exist that are quite different with respect to the parameters they measure and the strength of empirical evidence supporting their use. In general, heel QUS appears to be most tested and most effective. Overall, some, but not all, heel QUS devices are effective assessing fracture risk in some, but not all, populations, the evidence being strongest for Caucasian females over 55 years old. Otherwise, the evidence is fair with respect to certain devices allowing for the accurate diagnosis of likelihood of osteoporosis, and generally fair to poor in terms of QUS use when initiating or monitoring osteoporosis treatment. A reasonable protocol is proposed herein for case-finding purposes, which relies on a combined assessment of clinical risk factors (CR.F) and heel QUS. Finally, several recommendations are made for quality assurance and control.
Resumo:
This paper addresses primary care physicians, cardiologists, internists, angiologists and doctors desirous of improving vascular risk prediction in primary care. Many cardiovascular risk factors act aggressively on the arterial wall and result in atherosclerosis and atherothrombosis. Cardiovascular prognosis derived from ultrasound imaging is, however, excellent in subjects without formation of intimal thickening or atheromas. Since ultrasound visualises the arterial wall directly, the information derived from the arterial wall may add independent incremental information to the knowledge of risk derived from global risk assessment. This paper provides an overview on plaque imaging for vascular risk prediction in two parts: Part 1: Carotid IMT is frequently used as a surrogate marker for outcome in intervention studies addressing rather large cohorts of subjects. Carotid IMT as a risk prediction tool for the prevention of acute myocardial infarction and stroke has been extensively studied in many patients since 1987, and has yielded incremental hazard ratios for these cardiovascular events independently of established cardiovascular risk factors. However, carotid IMT measurements are not used uniformly and therefore still lack widely accepted standardisation. Hence, at an individual, practicebased level, carotid IMT is not recommended as a risk assessment tool. The total plaque area of the carotid arteries (TPA) is a measure of the global plaque burden within both carotid arteries. It was recently shown in a large Norwegian cohort involving over 6000 subjects that TPA is a very good predictor for future myocardial infarction in women with an area under the curve (AUC) using a receiver operating curves (ROC) value of 0.73 (in men: 0.63). Further, the AUC for risk prediction is high both for vascular death in a vascular prevention clinic group (AUC 0.77) and fatal or nonfatal myocardial infarction in a true primary care group (AUC 0.79). Since TPA has acceptable reproducibility, allows calculation of posttest risk and is easily obtained at low cost, this risk assessment tool may come in for more widespread use in the future and also serve as a tool for atherosclerosis tracking and guidance for intensity of preventive therapy. However, more studies with TPA are needed. Part 2: Carotid and femoral plaque formation as detected by ultrasound offers a global view of the extent of atherosclerosis. Several prospective cohort studies have shown that cardiovascular risk prediction is greater for plaques than for carotid IMT. The number of arterial beds affected by significant atheromas may simply be added numerically to derive additional information on the risk of vascular events. A new atherosclerosis burden score (ABS) simply calculates the sum of carotid and femoral plaques encountered during ultrasound scanning. ABS correlates well and independently with the presence of coronary atherosclerosis and stenosis as measured by invasive coronary angiogram. However, the prognostic power of ABS as an independent marker of risk still needs to be elucidated in prospective studies. In summary, the large number of ways to measure atherosclerosis and related changes in human arteries by ultrasound indicates that this technology is not yet sufficiently perfected and needs more standardisation and workup on clearly defined outcome studies before it can be recommended as a practice-based additional risk modifier.
Resumo:
Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
Resumo:
BACKGROUND: Colonic endoscopic submucosal dissection (ESD) is challenging as a result of the limited ability of conventional endoscopic instruments to achieve traction and exposure. The aim of this study was to evaluate the feasibility of colonic ESD in a porcine model using a novel endoscopic surgical platform, the Anubiscope (Karl Storz, Tüttlingen, Germany), equipped with two working channels for surgical instruments with four degrees of freedom offering surgical triangulation. METHODS: Nine ESDs were performed by a surgeon without any ESD experience in three swine, at 25, 15, and 10 cm above the anal verge with the Anubiscope. Sixteen ESDs were performed by an experienced endoscopist in five swine using conventional endoscopic instruments. Major ESD steps included the following for both groups: scoring the area, submucosal injection of glycerol, precut, and submucosal dissection. Outcomes measured were as follows: dissection time and speed, specimen size, en bloc dissection, and complications. RESULTS: No perforations occurred in the Anubis group, while there were eight perforations (50 %) in the conventional group (p = 0.02). Complete and en bloc dissections were achieved in all cases in the Anubis group. Mean dissection time for completed cases was statistically significantly shorter in the Anubis group (32.3 ± 16.1 vs. 55.87 ± 7.66 min; p = 0.0019). Mean specimen size was higher in the conventional group (1321 ± 230 vs. 927.77 ± 229.96 mm(2); p = 0.003), but mean dissection speed was similar (35.95 ± 18.93 vs. 23.98 ± 5.02 mm(2)/min in the Anubis and conventional groups, respectively; p = 0.1). CONCLUSIONS: Colonic ESDs were feasible in pig models with the Anubiscope. This surgical endoscopic platform is promising for endoluminal surgical procedures such as ESD, as it is user-friendly, effective, and safe.
Resumo:
Using a large prospective cohort of over 12,000 women, we determined 2 thresholds (high risk and low risk of hip fracture) to use in a 10-yr hip fracture probability model that we had previously described, a model combining the heel stiffness index measured by quantitative ultrasound (QUS) and a set of easily determined clinical risk factors (CRFs). The model identified a higher percentage of women with fractures as high risk than a previously reported risk score that combined QUS and CRF. In addition, it categorized women in a way that was quite consistent with the categorization that occurred using dual X-ray absorptiometry (DXA) and the World Health Organization (WHO) classification system; the 2 methods identified similar percentages of women with and without fractures in each of their 3 categories, but the 2 identified only in part the same women. Nevertheless, combining our composite probability model with DXA in a case findings strategy will likely further improve the detection of women at high risk of fragility hip fracture. We conclude that the currently proposed model may be of some use as an alternative to the WHO classification criteria for osteoporosis, at least when access to DXA is limited.
Resumo:
BACKGROUND: Some patients with a phenotypic appearance of eosinophilic oesophagitis (EoE) respond histologically to PPI, and are described as having PPI-responsive oesophageal eosinophilia (PPI-REE). It is unclear if PPI-REE is a GERD-related phenomenon, a subtype of EoE, or a completely unique entity. AIM: To compare demographic, clinical and histological features of EoE and PPI-REE. METHODS: Two databases were reviewed from the Walter Reed and Swiss EoE databases. Patients were stratified into two groups, EoE and PPI-REE, based on recent EoE consensus guidelines. Response to PPI was defined as achieving less than 15 eos/hpf and a 50% decrease from baseline following at least a 6-week course of treatment. RESULTS: One hundred and three patients were identified (63 EoE and 40 PPI-REE; mean age 40.2 years, 75% male and 89% Caucasian). The two cohorts had similar dysphagia (97% vs. 100%, P = 0.520), food impaction (43% vs. 35%, P = 0.536), and heartburn (33% vs. 32%, P = 1.000) and a similar duration of symptoms (6.0 years vs. 5.8 years, P = 0.850). Endoscopic features were also similar between EoE and PPI-REE; rings (68% vs. 68%, P = 1.000), furrows (70% vs. 70%, P = 1.000), plaques (19% vs. 10%, P = 0.272), strictures (49% vs. 30%, P = 0.066). EoE and PPI-REE were similar in the number of proximal (39 eos/hpf vs. 38 eos/hpf, P = 0.919) and distal eosinophils (50 vs. 43 eos/hpf, P = 0.285). CONCLUSIONS: EoE and PPI-responsive oesophageal eosinophilia are similar in clinical, histological and endoscopic features and therefore are indistinguishable without a PPI trial. Further studies are needed to determine why a subset of patients with oesophageal eosinophilia respond to PPI.
Resumo:
Objectives: Quantitative ultrasound (QUS) is an attractive method for assessing fracture risk because it is portable, inexpensive, without ionizing radiation, and available in areas of the world where DXA is not readily accessible or affordable. However, the diversity of QUS scanners and variability of fracture outcomes measured in different studies is an important obstacle to widespread utilisation of QUS for fracture risk assessment. We aimed in this review to assess the predictive power of heel QUS for fractures considering different characteristics of the association (QUS parameters and fracture outcomes measured, QUS devices, study populations, and independence from DXA-measured bone density).Materials/Methods : We conducted an inverse-variance randomeffects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound &SOS;, stiffness index &SI;, and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic, and major osteoporotic fractures) were reported based on study questions.Results : 21 studies including 55,164 women and 13,742 men were included with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fractures. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99), and QUI was 1.99 (95% CI 1.49-2.67). Validated devices from different manufacturers predicted fracture risks with a similar performance (meta-regression p-values>0.05 for difference of devices). There was no sign of publication bias among the studies. QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip DXA showed a significant and independent association with fracture risk (RR/SD for BUA =1.34 [95%CI 1.22-1.49]).Conclusions : This study confirms that QUS of the heel using validated devices predicts risk of different fracture outcomes in elderly men and women. Further research and international collaborations are needed for standardisation of QUS parameters across various manufacturers and inclusion of QUS in fracture risk assessment tools. Disclosure of Interest : None declared.
Resumo:
To compare the prediction of hip fracture risk of several bone ultrasounds (QUS), 7062 Swiss women > or =70 years of age were measured with three QUSs (two of the heel, one of the phalanges). Heel QUSs were both predictive of hip fracture risk, whereas the phalanges QUS was not. INTRODUCTION: As the number of hip fracture is expected to increase during these next decades, it is important to develop strategies to detect subjects at risk. Quantitative bone ultrasound (QUS), an ionizing radiation-free method, which is transportable, could be interesting for this purpose. MATERIALS AND METHODS: The Swiss Evaluation of the Methods of Measurement of Osteoporotic Fracture Risk (SEMOF) study is a multicenter cohort study, which compared three QUSs for the assessment of hip fracture risk in a sample of 7609 elderly ambulatory women > or =70 years of age. Two QUSs measured the heel (Achilles+; GE-Lunar and Sahara; Hologic), and one measured the heel (DBM Sonic 1200; IGEA). The Cox proportional hazards regression was used to estimate the hazard of the first hip fracture, adjusted for age, BMI, and center, and the area under the ROC curves were calculated to compare the devices and their parameters. RESULTS: From the 7609 women who were included in the study, 7062 women 75.2 +/- 3.1 (SD) years of age were prospectively followed for 2.9 +/- 0.8 years. Eighty women reported a hip fracture. A decrease by 1 SD of the QUS variables corresponded to an increase of the hip fracture risk from 2.3 (95% CI, 1.7, 3.1) to 2.6 (95% CI, 1.9, 3.4) for the three variables of Achilles+ and from 2.2 (95% CI, 1.7, 3.0) to 2.4 (95% CI, 1.8, 3.2) for the three variables of Sahara. Risk gradients did not differ significantly among the variables of the two heel QUS devices. On the other hand, the phalanges QUS (DBM Sonic 1200) was not predictive of hip fracture risk, with an adjusted hazard risk of 1.2 (95% CI, 0.9, 1.5), even after reanalysis of the digitalized data and using different cut-off levels (1700 or 1570 m/s). CONCLUSIONS: In this elderly women population, heel QUS devices were both predictive of hip fracture risk, whereas the phalanges QUS device was not.
Resumo:
This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.