977 resultados para electronic device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents an adaptive metering algorithm for enhancing the electronic screening (e-screening) operation at truck weight stations. This algorithm uses a feedback control mechanism to control the level of truck vehicles entering the weight station. The basic operation of the algorithm allows more trucks to be inspected when the weight station is underutilized by adjusting the weight threshold lower. Alternatively, the algorithm restricts the number of trucks to inspect when the station is overutilized to prevent queue spillover. The proposed control concept is demonstrated and evaluated in a simulation environment. The simulation results demonstrate the considerable benefits of the proposed algorithm in improving overweight enforcement with minimal negative impacts on nonoverweighed trucks. The test results also reveal that the effectiveness of the algorithm improves with higher truck participation rates in the e-screening program.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pt/anodized TiO2/SiC based metal-oxide-semiconductor (MOS) devices were fabricated and characterized for their sensitivity towards propene (C3H6). Titanium (Ti) thin films were deposited onto the SiC substrates using a filtered cathodic vacuum arc (FCVA) method. Fluoride ions containing neutral electrolyte (0.5 wt% NH4F in ethylene glycol)were used to anodize the Ti films. The anodized films were subsequently annealed at 600 °C for 4 hrs in an oxygen rich environment to obtain TiO2. The current-voltage(I-V) characteristics of the Pt/TiO2/SiC devices were measured in different concentrations of propene. Exposure to the analyte gas caused a change in the Schottky barrier height and hence a lateral shift in the I-V characteristics. The effective change in the barrier height for 1% propene was calculated as 32.8 meV at 620°C. The dynamic response of the sensors was also investigated and a voltage shift of 157 mV was measured at 620°C during exposure to 1% propene.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Interest in nanowires of metal oxide oxides has been exponentially growing in the last years, due to the attracting potential of application in electronic, optical and sensor field. We have focused our attention on the sensing properties of semiconducting nanowires as conductometric and optical gas sensors. Single crystal tin dioxide nanostructures were synthesized to explore and study their capability in form of multi-nanowires sensors. The nanowires of SnO2 have been used to produce a novel gas sensor based on Pt/oxide/SiC structure and operating as Schottky diode. For the first time, a reactive oxide layer in this device has been replaced by SnO2 nanowires. Proposed sensor has maintained the advantageous properties of known SiC- based MOS devices, that can be employed for the monitoring of gases (hydrogen and hydrocarbons) emitted by industrial combustion processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction The onset of Personally Controlled Electronic Health Records in Australia demand healthcare decision making processes to comprise, understand and accept electronic health records (EHR). Nurses play a key, central role in the healthcare decision making process and their perceptions and attitudes of EHRs are significant [1], which develop during their academic life. However, studies aimed at nursing students’ attitudes of EHRs are very limited [2-4]. A proper understanding of these attitudes and how they evolve with academic progress is important. This paper presents results from a survey conducted at a leading University in Queensland, Australia as a first step to filling this gap.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research was a step forward in developing a data integration framework for Electronic Health Records. The outcome of the research is a conceptual and logical Data Warehousing model for integrating Cardiac Surgery electronic data records. This thesis investigated the main obstacles for the healthcare data integration and proposes a data warehousing model suitable for integrating fragmented data in a Cardiac Surgery Unit.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background and purpose: The purpose of the work presented in this paper was to determine whether patient positioning and delivery errors could be detected using electronic portal images of intensity modulated radiotherapy (IMRT). Patients and methods: We carried out a series of controlled experiments delivering an IMRT beam to a humanoid phantom using both the dynamic and multiple static field method of delivery. The beams were imaged, the images calibrated to remove the IMRT fluence variation and then compared with calibrated images of the reference beams without any delivery or position errors. The first set of experiments involved translating the position of the phantom both laterally and in a superior/inferior direction a distance of 1, 2, 5 and 10 mm. The phantom was also rotated 1 and 28. For the second set of measurements the phantom position was kept fixed and delivery errors were introduced to the beam. The delivery errors took the form of leaf position and segment intensity errors. Results: The method was able to detect shifts in the phantom position of 1 mm, leaf position errors of 2 mm, and dosimetry errors of 10% on a single segment of a 15 segment IMRT step and shoot delivery (significantly less than 1% of the total dose). Conclusions: The results of this work have shown that the method of imaging the IMRT beam and calibrating the images to remove the intensity modulations could be a useful tool in verifying both the patient position and the delivery of the beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Structural and electronic properties have been studied for Boron Nitride nanoribbons (BNNR) with both zigzag and armchair shaped edge (Z-BNNR and A-BNNR) by first-principle spin-polarized total energy calculations. We found that the energy band gap of Z-BNNR is indirect and decreases monotonically with the increasing ribbon width, whereas direct energy band gap oscillation was observed for A-BNNRs. Additionally, C-substitution at either single boron or nitrogen atom site in BNNRs could induce spontaneous magnetization. Our results could be potentially useful to design magnetic nano-devices based on BNNRs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, ab initio density functional theory (DFT) calculations are performed to study the structural and electronic properties of diazonium reagent functionalized (4, 4) single-walled carbon nanotube (SWCNT). We find the aryl group covalently bonds with SWCNT and prefers to be perpendicular to the side wall of nanotube. It has a rotational barrier of 0.35 eV around the formed aryl-tube bond axis and should be thermodynamically stable at room temperature. Additionally, new peaks appeared around the Fermi energy in the density of state (DOS) due to the weak band dispersion. Increasing of the coverage of the functional group will result in significant upshift of the Fermi level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This research introduces the proposition that Electronic Dance Music’s beat-mixing function could be implemented to create immediacy in other musical genres. The inclusion of rhythmic sections at the beginning and end of each musical work created a ‘DJ friendly’ environment. The term used in this thesis to refer to the application of beat-mixing in Rock music is ‘ClubRock’. Collaboration between a number of DJs and Rock music professionals applied the process of beat-mixing to blend Rock tracks to produce a continuous ClubRock set. The DJ technique of beat-mixing Rock music transformed static renditions into a fluid creative work. The hybridisation of the two genres, EDM and Rock, resulted in a contribution to Rock music compositional approaches and the production of a unique Rock album; Manarays—Get Lucky.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Information and communications technologies are a significant component of the healthcare domain and electronic health records play a major role within it. As a result, it is important that they are accepted en masse by healthcare professionals. How healthcare professionals perceive the usefulness of electronic health records and their attitudes towards them have been shown to have significant effects on their overall acceptance. This paper investigates the role of perceived usefulness and attitude on the intention to use electronic health records by future healthcare professionals using polynomial regression with response surface analysis. Results show that the relationship is more complex than predicted in prior research. The paper concludes that the predicting properties of the above determinants must be further investigated to clearly understand their role in predicting the intention to use electronic health records and in designing systems that are better adopted by healthcare professionals of the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Accuracy of dose delivery in external beam radiotherapy is usually verified with electronic portal imaging (EPI) in which the treatment beam is used to check the positioning of the patient. However the resulting megavoltage x-ray images suffer from poor quality. The image quality can be improved by developing a special operating mode in the linear accelerator. The existing treatment beam is modified such that it produces enough low-energy photons for imaging. In this work the problem of optimizing the beam/detector combination to achieve optimal electronic portal image quality is addressed. The linac used for this study was modified to produce two experimental photon beams. These beams, named Al6 and Al10, were non-flat and were produced by 4MeV electrons hitting aluminum targets, 6 and 10mm thick respectively. The images produced by a conventional EPI system (6MV treatment beam and camera-based EPID with a Cu plate & Gd2O2S screen ) were compared with the images produced by the experimental beams and various screens with the same camera). The contrast of 0.8cm bone equivalent material in 5 cm water increased from 1.5% for the conventional system to 11% for the combination of Al6 beam with a 200mg/cm2 Gd2O2S screen. The signal-to-noise ratio calculated for 1cGy flood field images increased by about a factor of two for the same EPI systems. The spatial resolution of the two imaging systems was comparable. This work demonstrates that significant improvements in portal image contrast can be obtained by simultaneous optimization of the linac spectrum and EPI detector.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We have taken a new method of calibrating portal images of IMRT beams and used this to measure patient set-up accuracy and delivery errors, such as leaf errors and segment intensity errors during treatment. A calibration technique was used to remove the intensity modulations from the images leaving equivalent open field images that show patient anatomy that can be used for verification of the patient position. The images of the treatment beam can also be used to verify the delivery of the beam in terms of multileaf collimator leaf position and dosimetric errors. A series of controlled experiments delivering an IMRT anterior beam to the head and neck of a humanoid phantom were undertaken. A 2mm translation in the position of the phantom could be detected. With intentional introduction of delivery errors into the beam this method allowed us to detect leaf positioning errors of 2mm and variation in monitor units of 1%. The method was then applied to the case of a patient who received IMRT treatment to the larynx and cervical nodes. The anterior IMRT beam was imaged during four fractions and the images calibrated and investigated for the characteristic signs of patient position error and delivery error that were shown in the control experiments. No significant errors were seen. The method of imaging the IMRT beam and calibrating the images to remove the intensity modulations can be a useful tool in verifying both the patient position and the delivery of the beam.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Knowledge of current trends in nurse-administered procedural sedation and analgesia (PSA) in the cardiac catheterisation laboratory (CCL) may provide important insights into how to improve safety and effectiveness of this practice. Objective To characterise current practice as well as education and competency standards regarding nurse-administered PSA in Australian and New Zealand CCLs. Design A quantitative, cross-sectional, descriptive survey design was used. Methods Data were collected using a web-based questionnaire on practice, educational standards and protocols related to nurse-administered PSA. Descriptive statistics were used to analyse data. Results A sample of 62 nurses, each from a different CCL, completed a questionnaire that focused on PSA practice. Over half of the estimated total number of CCLs in Australia and New Zealand was represented. Nurse-administered PSA was used in 94% (n = 58) of respondents CCLs. All respondents indicated that benzodiazepines, opioids or a combination of both is used for PSA (n = 58). One respondent indicated that propofol was also used. 20% (n = 12) indicated that deep sedation is purposefully induced for defibrillation threshold testing and cardioversion without a second medical practitioner present. Sedation monitoring practices vary considerably between institutions. 31% (n = 18) indicated that comprehensive education about PSA is provided. 45% (n = 26) indicated that nurses who administer PSA should undergo competency assessment. Conclusion By characterising nurse-administered PSA in Australian and New Zealand CCLs, a baseline for future studies has been established. Areas of particular importance to improve include protocols for patient monitoring and comprehensive PSA education for CCL nurses in Australia and New Zealand.