Resumo:
Objective To determine the diagnostic accuracy of prenatal fetal echocardiography. Methods The study was a retrospective chart review of 190 consecutive patients over a 3-year period from November 1998 to February 2002 of all women referred to the Maternal Fetal Medicine unit, Mater Mothers Hospital, for fetal echocardiography. The prenatal diagnosis was compared with the postnatal diagnosis made by postnatal echocardiography, surgical findings or post-mortem. The accuracy of prenatal diagnosis was described on a predetermined 4-point scale. Results Of the 89 patients, for whom complete diagnostic follow-up was available, there was complete agreement between the prenatal and postnatal diagnosis in 63 cases, minor discrepancies in 25 cases and major disagreement in 1 case. Conclusions In experienced hands, fetal echocardiography is accurate and allows medical staff and patients information in order manage a pregnancy appropriately. Copyright (C) 2004 John Wiley Sons, Ltd.
Resumo:
Background: Fetal scalp lactate testing has been shown to be as useful as pH with added benefits. One remaining question is What level of lactate should trigger intervention in the first stage of labour?' Aims: This study aimed to establish the lactate level in the first stage of labour that indicates the need for intervention to ensure satisfactory outcomes for both babies and mothers. Methods: A prospective study at Mater Mothers' Hospital, Brisbane, Australia, a tertiary referral centre. One hundred and forty women in labour, with non-reassuring fetal heart rate traces, were tested using fetal blood scalp sampling of 5 mu L of capillary blood tested on an Accusport (Boeringer, Mannheim, East Sussex, UK) lactate meter. Decision to intervene in labour was based on clinical assessment plus a predetermined cut off. Main outcome measures were APGAR scores, cord arterial pH, meconium stained liquor and Intensive Care Nursery admission. Results: Two-graph receiver operating characteristic (TG-ROC) analysis showed optimal specificity, and sensitivity for predicting adverse neonatal outcomes was a scalp lactate level above 4.2 mmol/L. Conclusions: Fetal blood sampling remains the standard for further investigating-non-reassuring cardiotocograph (CTG) traces. Even so, it is a poor predictor of fetal outcomes. Scalp lactate has been shown to be at least as good a predictor as scalp pH, with the advantages of being easier, cheaper and with a lower rate of technical failure. Our study, found that a cut off fetal scalp lactate level of 4.2 mmol/L, in combination with an assessment of the entire clinical picture, is a useful tool in identifying those women who need intervention.
Resumo:
This prospective study evaluated serum procalcitonin (PCT) and C-reactive protein (CRP) as markers for systemic inflammatory response syndrome (SIRS)/sepsis and mortality in patients with traumatic brain injury and subarachnoid haemorrhage. Sixty-two patients were followed for 7 days. Serum PCT and CRP were measured on days 0, 1, 4, 5, 6 and 7. Seventy-seven per cent of patients with traumatic brain injury and 83% with subarachnoid haemorrhage developed SIRS or sepsis (P= 0.75). Baseline PCT and CRP were elevated in 35% and 55% ofpatients respectively (P=0.03). There was a statistically non-significant step-wise increase in serum PCT levels from no SIRS (0.4 +/- 0.6 ng/ml) to SIRS (3.05 +/- 9.3 ng/ml) to sepsis (5.5 +/- 12.5 ng/ml). A similar trend was noted in baseline PCT in patients with mild (0.06 +/- 0.9 ng/ml), moderate (0.8 +/- 0.7 ng/ml) and severe head injury (1.2 +/- 1.9 ng/ml). Such a gradation was not observed with serum CRP There was a non-significant trend towards baseline PCT being a better marker of hospital mortality compared with baseline CRP (ROC-AUC 0.56 vs 0.31 respectively). This is the first prospective study to document the high incidence of SIRS in neurosurgical patients. In our study, serum PCT appeared to correlate with severity of traumatic brain injury and mortality. However, it could not reliably distinguish between SIRS and sepsis in this cohort. This is in pan because baseline PCT elevation seemed to correlate with severity of injury. Only a small proportion ofpatients developed sepsis, thus necessitating a larger sample size to demonstrate the diagnostic usefulness of serum PCT as a marker of sepsis. Further clinical trials with larger sample sizes are required to confirm any potential role of PCT as a sepsis and outcome indicator in patients with head injuries or subarachnoid haemorrhage.
Resumo:
Background: Renal transplant recipients were noted to appear cushingoid while on low doses of steroid as part of a triple therapy immunosuppression of cyclosporin A (CsA), prednisolone, and azathioprine. Methods: The study group comprised adult renal transplant recipients with stable graft function who had received their renal allograft a minimum of 1 year previously (43 studies undertaken in 22 men and 20 women) with median daily prednisone dose of 7 mg (range 3-10). The control group was healthy nontransplant subjects [median dose 10 mg (10-30)]. Prednisolone bioavailability was measured using a limited 6-hour area under the curve (AUC), with prednisolone measured using specific HPLC assay. Results: The median prednisolone AUC/mg dose for all transplant recipients was significantly greater than the control group by approximately 50% (316 nmol(.)h/L/mg prednisolone versus 218). AUC was significantly higher in female recipients (median 415 versus 297 for men) and in recipients receiving cyclospotin (348 versus 285). The highest AUC was in women on estrogen supplements who were receiving cyclosporin (median 595). A significantly higher proportion of patients on triple therapy had steroid side effects compared with those on steroid and azathioprine (17/27 versus 4/15), more women than men had side effects (14/16 versus 7/22), and the AUC/mg prednisone was greater in those with side effects than without (median 377 versus 288 nmol-h/L/mg). Discussion: The results are consistent with the hypothesis that CsA increases the bioavailability of prednisolone, most likely through inhibition of beta-glycoprotein. The increased exposure to steroid increased the side-effect profile of steroids in the majority of patients. Because the major contributor to AUC is the maximum postdose concentration, it may be possible to use single-point monitoring (2 hours postdose) for routine clinical studies.
Resumo:
Background: Flexible video bronchoscopes, in particular the Olympus BF Type 3C160, are commonly used in pediatric respiratory medicine. There is no data on the magnification and distortion effects of these bronchoscopes yet important clinical decisions are made from the images. The aim of this study was to systematically describe the magnification and distortion of flexible bronchoscope images taken at various distances from the object. Methods: Using images of known objects and processing these by digital video and computer programs both magnification and distortion scales were derived. Results: Magnification changes as a linear function between 100 mm ( x 1) and 10 mm ( x 9.55) and then as an exponential function between 10 mm and 3 mm ( x 40) from the object. Magnification depends on the axis of orientation of the object to the optic axis or geometrical axis of the bronchoscope. Magnification also varies across the field of view with the central magnification being 39% greater than at the periphery of the field of view at 15 mm from the object. However, in the paediatric situation the diameter of the orifices is usually less than 10 mm and thus this limits the exposure to these peripheral limits of magnification reduction. Intraclass correlations for measurements and repeatability studies between instruments are very high, r = 0.96. Distortion occurs as both barrel and geometric types but both types are heterogeneous across the field of view. Distortion of geometric type ranges up to 30% at 3 mm from the object but may be as low as 5% depending on the position of the object in relation to the optic axis. Conclusion: We conclude that the optimal working distance range is between 40 and 10 mm from the object. However the clinician should be cognisant of both variations in magnification and distortion in clinical judgements.
Resumo:
Objectives: Cyclosporin is an immunosuppressant drug with a narrow therapeutic window. Trough and 2-h post-dose blood samples are currently used for therapeutic drug monitoring in solid organ transplant recipients. The aim of the current study was to develop a rapid HPLC-tandem mass spectrometry (HPLC-MS) method for the measurement of cyclosporin in whole blood that was not only suitable for the clinical setting but also considered a reference method. Methods: Blood samples (50 mu L) were prepared by protein precipitation followed by C-18 solid-phase extraction while using d(12) cyclosporin as the internal standard. Mass spectrometric detection was by selected reaction monitoring with an electrospray interface in positive ionization mode. Results: The assay was linear from 10 to 2000 mu g/L (r(2) > 0.996, n = 9). Inter-day,analytical recovery and imprecision using whole blood quality control samples at 10, 30, 400, 1500, and 2000 mu g/L were 94.9-103.5% and
Resumo:
The role of the therapeutic drug monitoring laboratory in support of immunosuppressant drug therapy is well established, and the introduction of sirolimus (SRL) is a new direction in this field. The lack of an immunoassay for several years has restricted the availability of SRL assay services. The recent availability of a CEDIA (R) SRL assay has the potential to improve this situation. The present communication has compared the CEDIA (R) SRL method with 2 established chromatographic methods, HPLC-UV and HPLC-MS/MS. The CEDIA (R) method, run on a Hitachi 917 analyzer, showed acceptable validation criteria with within-assay precision of 9.1% and 3.3%, and bias of 17.1% and 5.8%, at SRL concentrations of 5.0 mu g/L and 20 mu g/L, respectively. The corresponding between-run precision values were 11.5% and 3.3% and bias of 7.1% and 2.9% at 5.0 mu g/L and 20 mu g/L, respectively, The lower limit of quantification was found to be 3.0 mu g/L. A series of 96 EDTA whole-blood samples predominantly from renal transplant recipients were assayed by the 3 methods for comparison. It was found that the CEDIA (R) method showed a Deming regression line of CEDIA = 1.20 X HPLC-MS/MS - 0.07 (r = 0.934, SEE = 1.47), with a mean bias of 20.4%. Serial blood samples from 8 patients included in this evaluation showed that the CEDIA (R) method reflected the clinical fluctuations in the chromatographic methods, albeit with the variable bias noted. The CEDIA (R) method on the H917 analyzer is therefore a useful adjunct to SRL dosage individualization in renal transplant recipients.
Resumo:
Organosilica microspheres synthesised via a novel surfactant-free emulsion-based method show applicability towards optical encoding, solid-phase synthesis and high-throughput screening of bound oligonucleotide and peptide sequences.