964 resultados para denture teeth


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. Although most of the physical properties of denture base resin polymerized by microwave energy have been shown to be similar to resins polymerized by the conventional heat polymerization method, the presence of porosity is a problem.Purpose. This study evaluated the effect of different microwave polymerization cycles on the porosity of a denture base resin designed for microwave polymerization.Material and methods. Thirty-two rectangular resin specimens (65 X 40 X 5 mm) were divided into 3 experimental groups (A, B, and C; Onda-Cryl, microwave-polymerized resin) and I control group (T; Classico, heat-polymerized resin), according to the following polymerization cycles: (A) 500 W for 3 minutes, (B) 90 W for 13 minutes + 500 W for 90 seconds, (C) 320 W for 3 minutes + 0 W for 4 minutes + 720 W for 3 minutes, and (T) 74degreesC for 9 hours. Porosity was calculated by measurement of the specimen volume before and after its immersion in water. Data were analyzed using 1-way analysis of variance (alpha = .05).Results. The mean values and SDs of the percent mean porosity were: A = 1.05% +/- 0.28%, B = 0.91% +/- 0.15%, C = 0.88% +/- 0.23%, T = 0.93% +/- 0.23%. No significant differences were found in mean porosity among the groups evaluated.Conclusion. Within the limitations of this study, a denture base resin specifically designed for microwave Polymerization tested was not affected by different polymerization cycles. Porosity was similar to the conventional heat-polymerized denture base resin tested.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The objectives of this study were to evaluate, through panoramic radiographs, the mesiodistal axial inclinations of the maxillary anterior teeth at the beginning and end of nonextraction orthodontic treatment, and to compare the results with the mesiodistal axial inclinations of a control sample with normal (acceptable) occlusions. Methods: the experimental sample consisted of 40 white patients (20 male, 20 female; mean age, 14 years) with Class I maloccusions who were treated orthodontically with a standard edgewise (not preadjusted) technique without extractions. The mean treatment period was 1.6 years. The control sample comprised 42 white subjects (14 male, 28 female; age range, 12-17 years) with untreated normal (acceptable) occlusions. Panoramic radiographs were taken of the patients at the beginning (T1) and end (T2) of treatment. The mean values of the mesiodistal axial inclination at T1 were compared with the mean values at T2, and both were compared with the mesiodistal axial inclinations of the control sample. Results- the mesiodistal axial inclinations of the maxillary anterior teeth of the experimental group at T1 were different from those of the control group for 50% of the evaluated teeth. In contrast, the inclinations at T2 were consistent with the normal anatomical configuration of the controls. Conclusions: the panoramic radiograph is an effective tool for evaluating the mesiodistal axial inclinations of maxillary anterior teeth.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective. The objective of this study was to evaluate periapical repair following retrograde filling using different root-end filling materials.Study design. After induction of periapical lesions, 48 root canals from do teeth were partially filled. Endodontic surgery was performed and 3 different materials were used for root-end filling: Sealer 26, Sealapex plus zinc oxide, or mineral trioxide aggregate (NITA). No additional procedures were performed in the control group after partial filling of the root canal. After 180 days, the animals were killed, the rnaxillas and mandibles were removed, and specimens were submitted for histologic processing.Results. Histopathologic analysis revealed similar periapical repair for the groups in which Sealer 26, Sealapex plus zinc oxide, and MTA were used (P >.05). The control group showed unsatisfactory periapical repair W <.05).Conclusion. There was no difference in periapical tissue healing alter retrograde filling with the tested materials, which indicates that these 3 root-end filling materials are equally useful.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study was conducted to analyze the ablation rate and micromorphological aspects of microcavities in enamel and dentin of primary and permanent teeth using a Er:YAG laser system. Micromorphological evaluation has been performed in terms of permanent teeth; however, little information about Er: YAG laser interaction with primary teeth can be found in the literature. Because children have been the most beneficiary patients with laser therapy in our offices, it is extremely necessary to compare the effects of this kind of laser system on the enamel and dentin of permanent and primary teeth. In this study, we used eleven intact primary anterior exfoliated teeth and six extracted permanent molar teeth. We used a commercial laser system: a Er: YAG Twin Light laser system (Fotona Medical Lasers, Slovenia) at 2940 nm, changing average energy levels per pulse ( 100, 200, 300, and 400 mJ) producing 48 microcavities in enamel and dentin of primary and permanent teeth. Primary teeth are more easily ablated than are permanent teeth, when related to enamel or dentin. However, while this laser system is capable of slowly revealing the enamel's microstructure, in dentin only the lowest laser energies permit this kind of observation, more easily decomposing the original tissue aspect, when related to primary or permanent teeth. Statistically, the only different factor at the 5% level was an energy per pulse of 400 mJ, confirming the results found in SEM. Our results showed that dentin in both primary and permanent teeth is less resistant to Er: YAG laser ablation; this fact is easily observed under SEM observation and through the ablation rate evaluation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Two newborn males, two adult males 9 and 72 months old, one newborn female and two adult females of 30 and 54 months old pacas were used. Animals were radiographed on lateral recumbency, teeth were extracted and the vestibulolingual and mesiodistal lengths were achieved at the occlusal surface, besides the longitudinal length. The lower incisors presented greater length in relation to the other ones and sinuous shape; the upper incisors, relatively smaller, are practically straight. There is no canine tooth, and after a great diastema there is one premolar and three molars in each hemiarcade. In adult pacas, the enamel of incisors presents yellowish colour, mainly in the labial surface; in the premolars and molars, the enamel is present as internal sheets disposed nearly in a parallel way and in vestibulolingual direction, through practically all the dental length, which provides several joined teeth aspect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This retrospective study examined some different types of treatment to primary teeth. The aim of this study was to assess the treatment of traumatized primary teeth and the importance of a long-term follow up. Brazilian children in the age group of 1-4 years from a baby clinic took part in the study. Three hundred and fifteen patients suffered some type of traumatic injury, a total of 338 affected teeth. Data were registered in specific records and submitted to statistic analysis. The most prevalent type of treatment was monitor only (85%) followed by tooth extraction and endodontic procedure. Invasive treatments were performed in case of severe traumas, usually 6 months after the injury. We verified that a careful follow up might be the preferential choice to the treatment of traumatic primary teeth even in some severe cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this study was to evaluate the relationship between Candida and denture wear during the night. Twenty-four edentulous volunteers were randomly divided into two groups. Group I (GI, n = 11) was composed of volunteers who wore their complete dentures day and night and Group H (GII, n = 13) was composed of volunteers who wore their complete dentures only during the day. Three examination periods were performed for both groups. In GI, the first examination (A) was carried out after overnight denture wearing. Subsequent examinations were conducted after one (B) and seven nights (C) without denture use during sleep. In GII, the first (A) was done without previous use during sleep, and the following were carried out after one (B) and seven nights (C) of overnight denture wearing. Total un-stimulated saliva was collected in a sterile container and cultured in duplicate inside Petri dishes. The values of colony forming units (CFU mL(-1) +/- s.d.) were obtained: GI A - 10.1 x 10(3) +/- 1.2 x 10(4), B - 2.0 x 10(3) +/- 2.6 x 10(3), and C - 2.6 x 10(3) +/- 5.9 x 10(3) and GII: A - 0.4 x 10(3) +/- 0.6 x 10(3), B - 9.4 x 10(3) +/- 17.7 x 10(3) and C - 6.3 x 10(3) +/- 15.3 x 10(3). The mean counts for Candida sp. were expressed as log (CFU + 1) mL(-1) and statistical significance of differences among groups was tested by ANOVA (alpha = 0.05). Multiple comparisons were performed according to Bonferroni test and indicated significant differences between A-B and A-C, but not between B and C for both groups. It was concluded that there is a significant relationship between continuous denture wear and Candida sp.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: the purpose of this study was to evaluate the effect of two post-polymerisation treatments and different cycles of polymerisation on the cytotoxicity of two denture base resins.Materials and methods: the resins tested were Lucitone 550 and QC 20. Discs of resins were fabricated following the manufacturer's instructions. Lucitone 550 was processed by long cycle or short cycle. The resin QC 20 was processed by reverse cycle or normal cycle. The specimens were divided into groups: (i) post-polymerised in microwave for 3 min at 500 W; (ii) post-polymerised in water-bath at 55 degrees C for 60 min and (iii) without post-polymerisation. Eluates were prepared by placing three discs into a sterile glass vial with 9 ml of Eagle's medium and incubated at 37 degrees C for 24 hours. L929 cells were seeded into 96 3 well culture plates and DNA synthesis was assessed by H-thymidine incorporation assay.Results: the results were submitted to two-way ANOVA and Tukey HSD test. QC 20 specimens polymerised by the normal cycle and submitted to microwave post-polymerisation were graded as moderately cytotoxic. Similar results were observed for Lucitone 550 processed by long cycle without post-polymerisation. The other experimental groups were graded as not cytotoxic. After water-bath post-polymerisation, specimens of Lucitone 550 processed by long cycle produced significantly lower inhibition of DNA synthesis than the other groups.Conclusion: the long cycle increased the cytotoxicity of Lucitone 550 and water-bath post-polymerisation reduced the cytotoxicity of Lucitone 550 processed by long cycle.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: the purpose of this study was to evaluate the correlation between central incisor form and face form in 4 racial groups and to investigate if there was agreement among experts in categorizing the central incisor forms. Method and Materials: A total of 160 subjects (40 whites, 40 mulattos, 40 blacks, and 40 Asians) ranging from 18 to 33 years of age were selected. Digital photographic records were made, 1 full-face and 1 intraoral view of the maxillary right central incisor. The outline tracings of the tooth and face images were obtained using Adobe Photoshop 5.0 software. The outline tracings were printed in distinct transparencies, and 3 prosthodontists determined if there was correspondence between the tooth and the face forms by superimposition of the transparencies. If there was disagreement among the prosthodontists' evaluations, the prevalent decision was considered. The experts also classified the central incisor forms into square, ovoid, tapering, or combination at 2 different sessions. At the first session, no instructions were given. At the second session, the prosthodontists were instructed to follow Williams' method of classification. Results: A correspondence between tooth and face forms was found in 23.75% of all cases. Agreement on the tooth form classifications among the prosthodontists occurred in 30.62% of all cases at the first session and 24.37% at the second session. Conclusion: There is not a highly defined correlation between central incisor form and face form in any racial group studied. In addition, the experts were not in fair agreement in categorizing tooth forms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Statement of problem. A clinically significant incisal pin opening may occur after processing complete dentures if a compression molding technique is used. To recover the proper vertical dimension of occlusion, a time-consuming occlusal adjustment is necessary that often destroys the anatomy of the artificial teeth. A new injection molding process claims to produce dentures that require few, if any, occlusal adjustments in the laboratory after processing.Purpose. This laboratory study compared incisal pin opening, dimensional accuracy, and laboratory working time for dentures fabricated by this new injection system with dentures constructed by the conventional compression molding technique.Material and methods. Two groups of 6 maxillary and 6 mandibular dentures were evaluated as follows: group 1 (control), Lucitone 199, compression molded with a long cure cycle; and group 2, Lucitone 199, injection molded with a long cure. Incisal pin opening was measured with a micrometer immediately after deflasking. A computerized coordinate measuring machine was used to measure dimensional accuracy of 3-dimensional variations in selected positions of artificial teeth in 4 stages of denture fabrication. Analysis of variance (ANOVA) and t tests were performed to compare the groups.Results. A significant difference was found in pin opening between groups (t test). Horizontal dimensional changes evaluated with repeated measures ANOVA revealed no significant differences between groups. However, analysis of vertical dimensional changes disclosed significant differences between the groups. There was no appreciable difference in laboratory working time for flasking and molding denture bases between the injection and compression molding techniques when polymethyl methacrylate resin was used.Conclusion. The injection molding method produced a significantly smaller incisal pin opening over the standard compression molding technique. The injection molding technique, using polymethyl methacrylate, was a more accurate method for processing dentures. There were no appreciable differences in laboratory working time between the injection and compression molding techniques.