915 resultados para compression reinforcement
Resumo:
PURPOSE: Computer-based feedback systems for assessing the quality of cardiopulmonary resuscitation (CPR) are widely used these days. Recordings usually involve compression and ventilation dependent variables. Thorax compression depth, sufficient decompression and correct hand position are displayed but interpreted independently of one another. We aimed to generate a parameter, which represents all the combined relevant parameters of compression to provide a rapid assessment of the quality of chest compression-the effective compression ratio (ECR). METHODS: The following parameters were used to determine the ECR: compression depth, correct hand position, correct decompression and the proportion of time used for chest compressions compared to the total time spent on CPR. Based on the ERC guidelines, we calculated that guideline compliant CPR (30:2) has a minimum ECR of 0.79. To calculate the ECR, we expanded the previously described software solution. In order to demonstrate the usefulness of the new ECR-parameter, we first performed a PubMed search for studies that included correct compression and no-flow time, after which we calculated the new parameter, the ECR. RESULTS: The PubMed search revealed 9 trials. Calculated ECR values ranged between 0.03 (for basic life support [BLS] study, two helpers, no feedback) and 0.67 (BLS with feedback from the 6th minute). CONCLUSION: ECR enables rapid, meaningful assessment of CPR and simplifies the comparability of studies as well as the individual performance of trainees. The structure of the software solution allows it to be easily adapted to any manikin, CPR feedback devices and different resuscitation guidelines (e.g. ILCOR, ERC).
Resumo:
We study synaptic plasticity in a complex neuronal cell model where NMDA-spikes can arise in certain dendritic zones. In the context of reinforcement learning, two kinds of plasticity rules are derived, zone reinforcement (ZR) and cell reinforcement (CR), which both optimize the expected reward by stochastic gradient ascent. For ZR, the synaptic plasticity response to the external reward signal is modulated exclusively by quantities which are local to the NMDA-spike initiation zone in which the synapse is situated. CR, in addition, uses nonlocal feedback from the soma of the cell, provided by mechanisms such as the backpropagating action potential. Simulation results show that, compared to ZR, the use of nonlocal feedback in CR can drastically enhance learning performance. We suggest that the availability of nonlocal feedback for learning is a key advantage of complex neurons over networks of simple point neurons, which have previously been found to be largely equivalent with regard to computational capability.
Resumo:
Osteotomies of the proximal femur and stable fixation of displaced femoral neck fractures are demanding operations. An LCP Paediatric Hip Plate was developed to make these operations safer and less demanding. The article focuses on the surgical technique and critically analyses the device.
Resumo:
Cement augmentation using PMMA cement is known as an efficient treatment for osteoporotic vertebral compression fractures with a rapid release of pain in most patients and prevention of an ongoing kyphotic deformity of the vertebrae treated. However, after a vertebroplasty there is no chance to restore vertebral height. Using the technique of kyphoplasty a certain restoration of vertebral body height can be achieved. But there is a limitation of recovery due to loss of correction when deflating the kyphoplastic ballon and before injecting the cement. In addition, the instruments used are quite expensive. Lordoplasty is another technique to restore kyphosis by indirect fracture reduction as it is used with an internal fixateur. The fractured and the adjacent vertebrae are instrumented with bone cannulas bipediculary and the adjacent vertebrae are augmentated with cement. After curing of the cement the fractured vertebra is reduced by applying a lordotic moment via the cannulas. While maintaining the pretension the fractured vertebra is reinforced. We performed a prospective trial of 26 patients with a lordoplastic procedure. There was a pain relief of about 87% and a significant decrease in VAS value from 7.3 to 1.9. Due to lordoplasty there was a significant and permanent correction in vertebral and segmental kyphotic angle about 15.2 degrees and 10.0 degrees , respectively and also a significant restoration in anterior and mid vertebral height. Lordoplasty is a minimal invasive technique to restore vertebral body height. An immediate relief of pain is achieved in most patients. The procedure is safe and cost effective.
Resumo:
Despite changes in patient demographics and short-ened length of hospital stay deep vein thrombosis (DVT) remains a major health care problem which may lead to a variety of other high risk complications. Current treatment guidelines focus on preventive measures. Beside drug therapy, physical measures executed by nursing professionals exist, the outcomes of which are discussed controversially. Based on 25 studies that were found in MEDLINE and the Cochrane library, this systematic literature review identifies the effectiveness of intermittent pneumatic compression (IPC) on thrombosis prophylaxis. In almost all medical settings IPC contributes to a significant reduction of the incidence of DVT. At the same time, IPC has minimal negative side effects and is also cost effective. Correct application of IPC and patient compliance are essential to achieve its effectiveness. An increased awareness within the healthcare team in identifying the risk for and implementing measures against DVT is needed. Guidelines need to be developed in order to improve the effectiveness of thrombosis prophylaxis with the implementation of IPC.
Resumo:
Total hip arthroplasty (THA) still carries a higher failure rate in patients with avascular necrosis of the femoral head (AVN) than in a similar patient population with THA for other reasons. This is particularly true for the acetabular component. One of the major factors accounting for this is the compromised acetabular bone quality with structural defects subsequent to collapsing of the femoral head in high-grade AVN. In this study we implanted an acetabular reinforcement ring with hook (ARRH), which had been used successfully for other indications with acetabular bone stock deficiency, in 32 consecutive THA's in 29 patients with AVN. Five patients died during the observation period of causes unrelated to the surgery, one patient was lost to follow-up and one patient could not be followed up due to chronic illness, leaving 25 hips (23 patients) with a minimum follow-up of ten years (mean: 11.8; range: 10-15). The mean Merle d'Aubigne score increased significantly from 7.7 preoperatively to 16.6 postoperatively (p < 0.001). One revision was performed for aseptic stem loosening. Of the unrevised hips, one acetabular component was classified as definitively loose. The cumulative 12-year survivorship for THA with ARRH in AVN was 95.2% (confidence interval: 86.1-100%) for both components, 100% for the cup and 95.2% for the stem (86.1-100%).
Resumo:
OBJECTIVE: To investigate whether intermittent pneumatic compression (IPC) augments skin blood flow through transient suspension of local vasoregulation, the veno-arteriolar response (VAR), in healthy controls and in patients with peripheral arterial disease (PAD). METHODS: Nineteen healthy limbs and twenty-two limbs with PAD were examined. To assess VAR, skin blood flow (SBF) was measured using laser Doppler fluxmetry in the horizontal and sitting positions and was defined as percentage change with postural alteration [(horizontal SBF--sitting SBF)/horizontal SBF x 100]. On IPC application to the foot, the calf, or both, SBF was measured with laser Doppler fluxmetry, the probe being attached to the pulp of the big toe. RESULTS: Baseline VAR was higher in the controls 63.8 +/- 6.4% than in patients with PAD (31.7 +/- 13.4%, P = .0162). In both groups SBF was significantly higher with IPC than at rest (P < .0001). A higher percentage increase with IPC was demonstrated in the controls (242 +/- 85% to 788 +/- 318%) than in subjects with PAD, for each one of the three different IPC modes investigated (98 +/- 33% to 275 +/- 72%) with IPC was demonstrated. The SBF enhancement with IPC correlated with VAR for all three compression modes (r = 0.58, P = .002 for calf compression, r = 0.65, P < .0001 for foot compression alone, and r = 0.64, P = .0002 for combined foot and calf compression). CONCLUSION: The integrity of the veno-arteriolar response correlates with the level of skin blood flow augmentation generated with intermittent pneumatic compression, indicating that this may be associated with a transient suspension of the autoregulatory vasoconstriction both in healthy controls and in patients with PAD.
Resumo:
OBJECTIVE: The Ross operation remains a controversially discussed procedure, because concern exists regarding late dilatation of the neoaortic root and progressive regurgitation of the autograft valve. We present our early experience with an external reinforcement of the autograft, which is inserted into a prosthetic Dacron graft with an artificial aortic root configuration. This detail should help to prevent neoaortic root dilatation. PATIENTS AND METHODS: Between 2006 and 2007, 12 patients (mean age 16 +/- 38 years; range 15-38 years) underwent a Ross procedure by this technique. Indications were aortic regurgitation (n = 2), aortic stenosis (n = 5), and combined aortic stenosis and insufficiency (n = 5). A bicuspid aortic valve was present in 9 patients. Balloon valvuloplasty had been performed in 7 patients. Follow-up was performed by clinical and echocardiographic examinations. RESULTS: No early or late deaths occurred in this small series, and freedom from reoperation is 100%. Echocardiographic follow-up confirmed absence of aortic insufficiency in 11 patients after a mean of 11 months (range 2-30 months). In 1 patient, a small asymmetric regurgitation jet was already observed at discharge echocardiography. As expected, no neoaortic root dilatation was observed during follow-up. All patients are in New York Heart Association class I. CONCLUSIONS: The present technique is a simple and reproducible technical step that does not require significant additional time. Inclusion of the autograft within a root prosthesis may be especially indicated in situations known for late autograft dilatation, namely, bicuspid aortic valve, predominant aortic insufficiency, and ascending aortic enlargement.
Resumo:
INTRODUCTION: We report the results of a titanium acetabular reinforcement ring with a hook (ARRH) in primary total hip arthroplasty (THA), which was introduced in 1987 and continues to be used routinely in our center. The favorable results of this device in arthroplasty for developmental dysplasia and difficult revisions motivated its use in primary THA. With this implant only minimal acetabular reaming is necessary, anatomic positioning is achieved by placing the hook around the teardrop and a homogenous base for cementing the polyethylene cup is provided. MATERIALS AND METHODS: Between April 1987 and December 1991, 241 THAs with insertion of an ARRH were performed in 178 unselected, consecutive patients (average age 58 years; range 30-84 years) with a secondary osteoarthrosis in 41% of the cases. RESULTS: At the time of the latest follow-up, 33 patients (39 hips) had died and 17 cases had been lost to follow-up. The median follow-up was 122 months with a minimum of 10 years. Eight hips had been revised, leaving 177 hips in 120 living patients without revision. Six cups were revised because of aseptic loosening. Two hips were revised for sepsis. The mean Merle d'Aubigné score for the remaining hips was 16 (range 7-18) at the latest follow-up. For aseptic loosening, the probability of survival of the cup was 0.97 (95% confidence interval, 0.94-0.99). However, analysis of radiographs implied loosening in seven other cups without clinical symptoms. CONCLUSIONS: The results of primary THA using an acetabular reinforcement ring parallel the excellent results of these implants often observed in difficult primary and revision arthroplasty at a minimum of 10 years. Survivorship is comparable to modern cementless implants. Medial migration that occurs with loosening of the acetabular component seems to be prevented with this implant. Radiographic loosening signs can exist without clinical symptoms.
Resumo:
Due to the inherent limitations of DXA, assessment of the biomechanical properties of vertebral bodies relies increasingly on CT-based finite element (FE) models, but these often use simplistic material behaviour and/or single loading cases. In this study, we applied a novel constitutive law for bone elasticity, plasticity and damage to FE models created from coarsened pQCT images of human vertebrae, and compared vertebral stiffness, strength and damage accumulation for axial compression, anterior flexion and a combination of these two cases. FE axial stiffness and strength correlated with experiments and were linearly related to flexion properties. In all loading modes, damage localised preferentially in the trabecular compartment. Damage for the combined loading was higher than cumulated damage produced by individual compression and flexion. In conclusion, this FE method predicts stiffness and strength of vertebral bodies from CT images with clinical resolution and provides insight into damage accumulation in various loading modes.