IMPORTANCE: Owing to a considerable shift toward bioprosthesis implantation rather than mechanical valves, it is expected that patients will increasingly present with degenerated bioprostheses in the next few years. Transcatheter aortic valve-in-valve implantation is a less invasive approach for patients with structural valve deterioration; however, a comprehensive evaluation of survival after the procedure has not yet been performed. OBJECTIVE: To determine the survival of patients after transcatheter valve-in-valve implantation inside failed surgical bioprosthetic valves. DESIGN, SETTING, AND PARTICIPANTS: Correlates for survival were evaluated using a multinational valve-in-valve registry that included 459 patients with degenerated bioprosthetic valves undergoing valve-in-valve implantation between 2007 and May 2013 in 55 centers (mean age, 77.6 [SD, 9.8] years; 56% men; median Society of Thoracic Surgeons mortality prediction score, 9.8% [interquartile range, 7.7%-16%]). Surgical valves were classified as small (≤21 mm; 29.7%), intermediate (>21 and <25 mm; 39.3%), and large (≥25 mm; 31%). Implanted devices included both balloon- and self-expandable valves. MAIN OUTCOMES AND MEASURES: Survival, stroke, and New York Heart Association functional class. RESULTS: Modes of bioprosthesis failure were stenosis (n = 181 [39.4%]), regurgitation (n = 139 [30.3%]), and combined (n = 139 [30.3%]). The stenosis group had a higher percentage of small valves (37% vs 20.9% and 26.6% in the regurgitation and combined groups, respectively; P = .005). Within 1 month following valve-in-valve implantation, 35 (7.6%) patients died, 8 (1.7%) had major stroke, and 313 (92.6%) of surviving patients had good functional status (New York Heart Association class I/II). The overall 1-year Kaplan-Meier survival rate was 83.2% (95% CI, 80.8%-84.7%; 62 death events; 228 survivors). Patients in the stenosis group had worse 1-year survival (76.6%; 95% CI, 68.9%-83.1%; 34 deaths; 86 survivors) in comparison with the regurgitation group (91.2%; 95% CI, 85.7%-96.7%; 10 deaths; 76 survivors) and the combined group (83.9%; 95% CI, 76.8%-91%; 18 deaths; 66 survivors) (P = .01). Similarly, patients with small valves had worse 1-year survival (74.8% [95% CI, 66.2%-83.4%]; 27 deaths; 57 survivors) vs with intermediate-sized valves (81.8%; 95% CI, 75.3%-88.3%; 26 deaths; 92 survivors) and with large valves (93.3%; 95% CI, 85.7%-96.7%; 7 deaths; 73 survivors) (P = .001). Factors associated with mortality within 1 year included having small surgical bioprosthesis (≤21 mm; hazard ratio, 2.04; 95% CI, 1.14-3.67; P = .02) and baseline stenosis (vs regurgitation; hazard ratio, 3.07; 95% CI, 1.33-7.08; P = .008). CONCLUSIONS AND RELEVANCE: In this registry of patients who underwent transcatheter valve-in-valve implantation for degenerated bioprosthetic aortic valves, overall 1-year survival was 83.2%. Survival was lower among patients with small bioprostheses and those with predominant surgical valve stenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Patients who have acute coronary syndromes with or without ST-segment elevation have high rates of major vascular events. We evaluated the efficacy of early clopidogrel administration (300 mg) (<24 hours) when given with aspirin in such patients. METHODS: We included 30,243 patients who had an acute coronary syndrome with or without ST segment elevation. Data on early clopidogrel administration were available for 24,463 (81%). Some 15,525 (51%) of the total cohort were administrated clopidogrel within 24h of admission. RESULTS: In-hospital death occurred in 2.9% of the patients in the early clopidogrel group treated with primary PCI and in 11.4% of the patients in the other group without primary percutaneous coronary intervention (PCI) and no early clopidogrel. The unadjusted clopidogrel odds ratio (OR) for mortality was 0.31 (95% confidence interval 0.27-0.34; p <0.001). Incidence of major adverse cardiac death (MACE) was 4.1% in the early clopidogrel group treated with 1°PCI and 13.5% in the other group without primary PCI and no early clopidogrel (OR 0.35, confidence interval 0.32-0.39, p <0.001). Early clopidogrel administration and PCI were the only treatment lowering mortality as shown by mutlivariate analysis. CONCLUSIONS: The early administration of the anti-platelet agent clopidogrel in patients with acute coronary syndromes with or without ST-segment elevation has a beneficial effect on mortality and major adverse cardiac events. The lower mortality rate and incidence of MACE emerged with a combination of primary PCI and early clopidogrel administration.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The time-lag between coronary occlusion and irreversible damage to the myocardium is ill-defined in man. In 10 patients the changes in left ventricular function have been studied after coronary occlusion during diagnostic or therapeutic cardiac catheterization of 1-2 hours' duration. Revascularization was achieved either surgically or through intracoronary streptokinase infusion. The interval between occlusion and onset of extracorporal circulation or reopening was 61 to 119 minutes. Despite enzyme elevation (CPK, CK-MB, SGOT) and appearance of Q-waves in 5 patients, no significant alteration of left ventricular function was noted on repeat cardiac catheterization 10 to 230 days after the accident. These observations, suggest that coronary occlusion of 1-2 hours' duration fails to produce significant irreversible damage to the myocardium despite electrocardiographic and enzymatic signs of myocardial infarction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The measurement of cardiac output is a key element in the assessment of cardiac function. Recently, a pulse contour analysis-based device without need for calibration became available (FloTrac/Vigileo, Edwards Lifescience, Irvine, CA). This study was conducted to determine if there is an impact of the arterial catheter site and to investigate the accuracy of this system when compared with the pulmonary artery catheter using the bolus thermodilution technique (PAC). DESIGN: Prospective study. SETTING: The operating room of 1 university hospital. PARTICIPANTS: Twenty patients undergoing cardiac surgery. INTERVENTIONS: CO was determined in parallel by the use of the Flotrac/Vigileo systems in the radial and femoral position (CO_rad and CO_fem) and by PAC as the reference method. Data triplets were recorded at defined time points. The primary endpoint was the comparison of CO_rad and CO_fem, and the secondary endpoint was the comparison with the PAC. MEASUREMENTS AND MAIN RESULTS: Seventy-eight simultaneous data recordings were obtained. The Bland-Altman analysis for CO_fem and CO_rad showed a bias of 0.46 L/min, precision was 0.85 L/min, and the percentage error was 34%. The Bland-Altman analysis for CO_rad and PAC showed a bias of -0.35 L/min, the precision was 1.88 L/min, and the percentage error was 76%. The Bland-Altman analysis for CO_fem and PAC showed a bias of 0.11 L/min, the precision was 1.8 L/min, and the percentage error was 69%. CONCLUSION: The FloTrac/Vigileo system was shown to not produce exactly the same CO data when used in radial and femoral arteries, even though the percentage error was close to the clinically acceptable range. Thus, the impact of the introduction site of the arterial catheter is not negligible. The agreement with thermodilution was low.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Spondylo-megaepiphyseal-metaphyseal dysplasia (SMMD; OMIM 613330) is a dysostosis/dysplasia caused by recessive mutations in the homeobox-containing gene, NKX3-2 (formerly known as BAPX1). Because of the rarity of the condition, its diagnostic features and natural course are not well known. We describe clinical and radiographic findings in six patients (five of which with homozygous mutations in the NKX3-2 gene) and highlight the unusual and severe changes in the cervical spine and the neurologic complications. In individuals with SMMD, the trunk and the neck are short, while the limbs, fingers and toes are disproportionately long. Radiographs show a severe ossification delay of the vertebral bodies with sagittal and coronal clefts, missing ossification of the pubic bones, large round "balloon-like" epiphyses of the long bones, and presence of multiple pseudoepiphyses at all metacarpals and phalanges. Reduced or absent ossification of the cervical vertebrae leads to cervical instability with anterior or posterior kinking of the cervical spine (swan neck-like deformity, kyknodysostosis). As a result of the cervical spine instability or deformation, five of six patients in our series suffered cervical cord injury that manifested clinically as limb spasticity. Although the number of individuals observed is small, the high incidence of cervical spine deformation in SMMD is unique among skeletal dysplasias. Early diagnosis of SMMD by recognition of the radiographic pattern might prevent of the neurologic complications via prophylactic cervical spine stabilization. © 2012 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Transcatheter aortic valve-in-valve implantation is an emerging therapeutic alternative for patients with a failed surgical bioprosthesis and may obviate the need for reoperation. We evaluated the clinical results of this technique using a large, worldwide registry. METHODS AND RESULTS: The Global Valve-in-Valve Registry included 202 patients with degenerated bioprosthetic valves (aged 77.7±10.4 years; 52.5% men) from 38 cardiac centers. Bioprosthesis mode of failure was stenosis (n=85; 42%), regurgitation (n=68; 34%), or combined stenosis and regurgitation (n=49; 24%). Implanted devices included CoreValve (n=124) and Edwards SAPIEN (n=78). Procedural success was achieved in 93.1% of cases. Adverse procedural outcomes included initial device malposition in 15.3% of cases and ostial coronary obstruction in 3.5%. After the procedure, valve maximum/mean gradients were 28.4±14.1/15.9±8.6 mm Hg, and 95% of patients had ≤+1 degree of aortic regurgitation. At 30-day follow-up, all-cause mortality was 8.4%, and 84.1% of patients were at New York Heart Association functional class I/II. One-year follow-up was obtained in 87 patients, with 85.8% survival of treated patients. CONCLUSIONS: The valve-in-valve procedure is clinically effective in the vast majority of patients with degenerated bioprosthetic valves. Safety and efficacy concerns include device malposition, ostial coronary obstruction, and high gradients after the procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Levofloxacin was investigated against viridans group streptococci in vitro and in rats with experimental aortic endocarditis. The MIC(90)s of levofloxacin and ciprofloxacin for 20 independent isolates of such bacteria were 1 and 8 mg/L, respectively. Rats were infected with two types of organism: either fully susceptible to levofloxacin MIC < or = 0.5 mg/L) or borderline susceptible (MIC 1-2 mg/L). Fully levofloxacin-susceptible bacteria comprised one penicillin-susceptible (MIC 0.004 mg/L) Streptococcus gordonii, and one penicillin-tolerant as well as one intermediate penicillin-resistant (MIC 0.125 mg/L) isogenic strains. Borderline levofloxacin-susceptible bacteria comprised one penicillin-susceptible Streptococcus sanguis and one highly penicillin-resistant Streptococcus mitis (MIC 2 mg/L). Rats were treated for 5 days with drug dosages simulating the following treatments in humans: (i) levofloxacin 500 mg orally once a day (q24 h), (ii) levofloxacin 500 mg orally twice a day (q12 h), (iii) levofloxacin 1 g orally q24 h, (iv) ciprofloxacin 750 mg orally q12 h, and (v) ceftriaxone 2 g iv q24 h. Levofloxacin was equivalent or superior to ceftriaxone, and was successful in treating experimental endocarditis irrespective of penicillin resistance. Nevertheless, standard levofloxacin treatment equivalent to 500 mg q24 h in human was less effective than twice daily 500 mg or once daily 1 g doses against borderline-susceptible organisms. Ciprofloxacin, used as a negative control, was ineffective and selected for resistant isolates. This underlines the importance of MIC determinations when treating severe streptococcal infection with quinolones. In the case of borderline-susceptible pathogens, total daily doses of 1 g of levofloxacin should be considered.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Alteplase has been shown to be effective in preventing central venous access clotting in patients on hemodialysis. Because of a high phosphorus content in its excipient, it can inadvertently contaminate blood samples, leading the physician in care of the patient to erroneously increase dialysis time or change diet in order to control the pseudo-hyperphosphatemia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A 56-year-old patient admitted to hospital for the suspicion of an acute coronary syndrome underwent coronary angiography without detection of significant lesions. Seven days later the echocardiography showed acute severe aortic valve insufficiency. Intraoperatively we found a perforated leaflet probably due to lesion during transcatheter procedure.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Der Autor befasst sich mit dem Thema e-Voting am Beispiel der Schweiz. Umwählen zu gehen, begibt sich der Bürger auf Wählerseiten im Internet. Dort beantwortet er zuerst 10 Fragen zu bedeutsamen politischen Themen. Je nach seinen Antworten werden die dafür politisch eintretenden Kandidaten vorgestellt. Der Wähler kann sich nun detailliert über sie und ihre politischen Positionen informieren und dann entscheiden, welchem Politiker er seine Stimme gibt. Voraussetzung hierfür ist, dass die Kandidaten präzise Angaben über ihre Person und die von ihnen vertretene Politik im Internet zugänglich machen, da sie ansonsten auf den Wahlseiten nicht zugelassen würden und somit ihre Chancen, gewählt zu werden, minimieren würden. Hat der Bürger sich festgelegt, schickt er das Dokument zur Auswertung an einen Server des Staates, der dann innerhalb von Stunden das neue Wahlergebnis präsentieren könnte. Die Wahlseiten selbst werden wahrscheinlich nicht vom Staat kontrolliert, da die Regierung diese manipulieren könnte. Wenn aber die Gestaltung der Seiten in private Hand gelegt wird, besteht die Gefahr, dass die Listen nicht als offizielle Wahllisten anerkannt werden. Hier besteht also noch Klärungsbedarf. Ein klarer Vorteil solcher Wahlseiten ist, dass die Ziele und Interessen der Politiker noch transparenter werden. Das Internet bietet dem Bürger die Möglichkeit, seine persönlichen Interessen mit denen der Politiker zu vergleichen und sich dann nach einem Abwägunsprozess zu entscheiden. ,,In einigen Jahren werden hier zu Lande Wahlurnen ganz verschwinden", prophezeit der Autor und verweist auf die Arbeit einer Projektgruppe, die die noch offenen Fragen des E-Votings klären will.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: The arteries of bifurcation aneurysms are sometimes so angulated or tortuous that an exchange maneuver is necessary to catheterize them with a balloon or stent delivery catheter. Because of the risk of distal wire perforation associated with exchange maneuvers, we sought to find an alternative technique. METHODS: Our experience shows that a microcatheter tends to preferentially follow a previously placed microcatheter, even if the initial catheterization might be challenging. Accessing an artery with two microcatheters simultaneously may thus be an alternative to an exchange maneuver. Because of this tendency for catheters to behave like sheep following one another, we named this method the sheeping technique (ST). The ST consists of (a) first placing a 1.7 French microcatheter into the division branch requiring balloon or stent protection to straighten the course of the arteries in order to facilitate and (b) positioning in the same artery of a larger and stiffer balloon or stent microcatheter. Once the second balloon or stent microcatheter is in place, the first microcatheter can be pulled back and used to coil the aneurysm. RESULTS: Between January 2009 and December 2012, The ST was successfully used in 208/246 procedures (85 %). Conversion to an exchange maneuver was necessary in 38/246 (15 %). There were no arterial perforations or ischemic events related to the handling of both microcatheters. CONCLUSION: The sheeping technique may improve safety by replacing the need for an exchange maneuver during difficult balloon- or stent-assisted coiling.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: Totally implanted vascular (TIVA) ports are used in children for repeated blood samples or intravenous treatments. We have recently published a prospective evaluation of surgical incidents and early complications associated with these devices. This work is the final part of the same study, assessing late complications over a follow-up of 2 yrs. METHODS: From January 2006 to January 2008, children older than 1 yr of age with a diagnosis of solid or blood cell malignancy were included. Insertion technique and care of the device were standardized. Every manipulation was prospectively recorded by specialized nurses. Obstruction was documented clinically. When bacteremia was suspected, routine central and peripheral blood cultures were drawn. RESULTS: Forty-five consecutive patients were enrolled in the study. Mean age at the time of the procedure was 8.5 yrs. There was no catheter-related infection within the first 4 weeks post-surgery. No device had to be removed because of infection or obstruction during follow-up. Frequent accesses to the port (=3 per day over a 10-day period) were associated with an 8-fold risk of infection. CONCLUSION: Insertion and use of TIVA devices were frequently associated with complications. No device had to be removed because of infection or obstruction over the follow-up period, although no prophylactic antibiotic agent was used. Restrictive use of antibiotics may prevent opportunistic infection. Frequent access to the device was significantly associated with line infection (odds ratio=8.43). No risk factor was identified for obstruction which occurred at a rate of 5.3 per 10,000 accesses.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: A misleading blood tacrolimus concentration (BTC) value caused by the contamination of a central venous catheter previously used for tacrolimus administration is described. SUMMARY: A 59-year-old woman with severe chronic obstructive pulmonary disease successfully underwent double lung transplantation. In the intensive care unit, she received a continuous i.v. infusion of tacrolimus from days 1 to 5 after transplantation through the distal lumen of a polyurethane triple-lumen central venous catheter. The catheter lumen was flushed twice a day with 0.9% sodium chloride injection. The proximal lumen was used for blood sampling after being flushed; the first 10 mL of blood was discarded. BTCs determined in whole blood one, four, and five days after transplantation were within the therapeutic range of 5-15 ng/mL. On day five the patient was transferred to the thoracic surgery ward and was switched to oral tacrolimus 1.5 mg twice daily. The BTC on day 6 was unexpectedly high at 134.5 ng/mL. The patient's clinical status was normal, and no signs of tacrolimus toxicity were observed. On day 7, blood samples were drawn from a peripheral vein and simultaneously through the central venous catheter. Although the central venous catheter had not been exposed to tacrolimus during the preceding two days, it yielded blood with a BTC eight times higher than the BTC in blood from the peripheral vein (41.4 ng/mL versus 5.1 ng/mL). CONCLUSION: The collection of blood from a central venous catheter lumen that had been used for tacrolimus administration resulted in a BTC about eight times higher than what was measured in peripheral blood.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Drug eluting stent (DES) restenosis has emerged as a significant clinical entity owing to the increasing use of DES in complex lesions and patients. However, to date, there is a paucity of studies that have addressed the management of DES restenosis and the resulting outcome, leaving the interventional cardiologist with a therapeutic dilemma. The purpose of this paper is therefore to provide a concise review of available data's dealing with the treatment of DES restenosis, including the outcome of patients treated for DES restenosis, the prognostic importance of the angiographic pattern and the available therapeutic modalities.