963 resultados para automatic target detection
Resumo:
Objectives: To evaluate the accuracy of three different cutoff points for the detection of high blood pressure in adolescents, given the strong relationship between overweight and high blood pressure levels.Methods: A total of 1,021 adolescents of both sexes were enrolled in the study, selected at random from public and private schools in Londrina, Brazil. Their body weight was measured using a digital balance, and their height with a portable stadiometer with a maximum extension of 2 meters. Arterial blood pressure was measured using an automatic apparatus. The capacity of body mass index to detect high blood pressure was gauged using ROC curves and their parameters (sensitivity, specificity, and area under the curve).Results: The cutoff points proposed in a Brazilian standard exhibited greater accuracy (males: 0.636 +/- 0.038; females: 0.585 +/- 0.043) than the cutoff points proposed in an international (males: 0.594 +/- 0.040; females: 0.570 +/- 0.044) and a North-American standard (males: 0.612 +/- 0.039; females: 0.578 +/- 0.044).Conclusions: The Brazilian proposal offered greatest accuracy for indicating high blood pressure levels.
Resumo:
We present a new strategy for the label-free electrochemical detection of DNA hybridization for detecting hepatitis C virus based on electrostatic modulation of the ion-exchange kinetics of a polypyrrole film deposited at microelectrodes. Synthetic single-stranded 18-mer HCV genotype-1-specific probe DNA has been immobilized at a 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole film established by electropolymerization at the previously formed polypyrrole layer. HCV DNA sequences (244-mer) resulting from the reverse transcriptase-linked polymerase chain reaction amplification of the original viral RNA were monitored by affecting the ion-exchange properties of the polypyrrole film. The performance of this miniaturized DNA sensor system was studied in respect to selectivity, sensitivity, and reproducibility. The limit of detection was determined at 1.82 x 10(-21) mol L-1. Control experiments were performed with cDNA from HCV genotypes 2a/c, 2b, and 3 and did not show any unspecific binding. Additionally, the influence of the spacer length of 2,5-bis(2-thienyl)-N-(3-phosphoryl-n-alkyl)pyrrole on the behavior of the DNA sensor was investigated. This biosensing scheme was finally extended to the electrochemical detection of DNA at submicrometer-sized DNA biosensors integrated into bifunctional atomic force scanning electrochemical microscopy probes. The 18-mer DNA target was again monitored by following the ion-exchange properties of the polypyrrole film. Control experiments were performed with 12-base pair mismatched sequences.
Resumo:
Epstein-Barr virus (EBV) has been associated with 10% of gastric carcinomas. The aim of this study was to determine the frequency of EBV in gastric carcinomas in Brazil assessed by in situ hybridization (ISH) and PCR, which would contribute to the characterization of the clinical and pathological aspects of EBV-associated gastric carcinomas. One hundred and ninety-two gastric carcinoma cases were collected at hospitals in two Brazilian states. Seventy-three out of 151 cases were PCR(+), while 11/160 cases were ISH(+). Nine out of eleven ISH(+) cases displayed a diffuse staining pattern and 2 out of 11 a focal pattern. Both techniques showed that the EBV(+) cases were characterized by their association with males, older patients, lower gastric region, intestinal type, advanced stage and poorly to moderately differentiated tumors. The concordance between the two techniques was 55.8% (Cohen's kappa index = 0.034). Four cases were ISH(+)/PCR(-), while 49 cases were PCR(+)/ISH(-). Only two cases showed stained lymphocytes by ISH and one of them was PCR(-). The observed discrepancy between the two techniques could not be explained just by the elevated accuracy of PCR. ISH(+)/PCR(-) carcinomas may be encountered if EBV is not present in the whole tumor tissue or if there are polymorphisms in the sequences of the viral genome amplified. on the other hand, the high frequency of PCR(+) results associated with the absence of ISH staining in lymphocytes and/or tumors cells suggests that the virus may be present in tumor cells or other cell types without expressing EBER1, the target of the ISH technique.
Resumo:
Introduction ,,,,,Despite hepatocytes being the target cells of hepatitis C virus (HCV), viral ribonucleic acid RNA has been detected in other cells, including platelets, which have been described as carriers of the virus in the circulation of infected patients. Platelets do not express cluster differentiation 81 CD81, the main receptor for the virus in hepatocytes, although this receptor protein has been found in megakaryocytes. Still, it is not clear if HCV interacts with platelets directly or if this interaction is a consequence of its association with megakaryocytes. The aim of this study was to evaluate the interaction of HCV with platelets from non-infected individuals, after in vitro exposure to the virus. ,,,, ,,,, ,,,,,Methods ,,,,,Platelets obtained from 50 blood donors not infected by HCV were incubated in vitro at 37°C for 48h with serum containing 100,000IU∕mL of genotype 1 HCV. After incubation, RNA extracted from the platelets was assayed for the presence of HCV by reverse transcription – polymerase chain reaction RT-PCR. ,,,, ,,,, ,,,,,Results ,,,,,After incubation in the presence of virus, all samples of platelets showed HCV RNA. ,,,, ,,,, ,,,,,Conclusions ,,,,,The results demonstrate that, in vitro, the virus interacts with platelets despite the absence of the receptor CD81, suggesting that other molecules could be involved in this association.
Resumo:
A label-free electrochemical detection method for DNA hybridization based on electrostatic modulation of the ion-exchange kinetics of a polypyrrole film deposited at microelectrodes is reported. Synthetic single-stranded 27-mer oligonucleotides (probe) have been immobilized at 2,5-bis(2-thienyl)-N-(3-phosphorylpropyl)pyrrole film formed by electropolymerization on the previously formed polypyrrole layer. The 27- or 18-mer target oligonucleotides were monitored via the electrochemically driven anion exchange of the inner polypyrrole film. The performance of the miniaturized DNA biosensor system was studied in respect to selectivity, sensitivity, reproducibility, and regeneration of the sensor. Control experiments were performed with a noncomplementary target of 27-mer DNA and 12 base-pair mismatched 18-mer sequences, respectively, and did not show any unspecific binding. Under optimized experimental conditions, the label-free electrochemical biosensor enabled the detection limits of 0.16 and 3.5 fmol for the 18- and 2 7-mer DNA strand, respectively. Furthermore, we demonstrate reusability of the electrochemical DNA biosensor after successful recovery of up to 100% of the original signal by regenerating the DNA label-free electrode with 50 mM HCl at room temperature.
Resumo:
A perylene derivative, n-(n-butyl)-n'-(4-aminobutyl) perylene-3,4,9,10-tetracarboxylic acid diimide (simplified as nBu-PTCD-(CH2)(4)-NH2) has been chosen as the target molecule for studies involving single molecule detection (SMD) using Raman scattering. The enhancement of the Raman signal is the result of the multiplicative effects of two phenomena, resonance Raman scattering (RRS) and surface-enhanced Raman scattering (SERS), which leads to the resulting surface-enhanced resonance Raman scattering (SERRS) process. The SERRS spectra from a single molecule have been collected using both silver and gold colloids. The SMD detection of the fundamental vibrational frequencies characteristic of nBu-PTCD-(CH2)(4)-NH2 is complemented with the detection of some overtones and combinations from ring stretching modes at the single molecule level. The background characterization of the ensemble vibrational spectroscopy of the target perylene and its SERRS is also presented, which includes the UV-vis absorption, experimental and calculated Raman scattering and infrared absorption, and molecular organization using reflection-absorption infrared spectroscopy (RAIRS).
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This paper presents results from an efficient approach to an automatic detection and extraction of human faces from images with any color, texture or objects in background, that consist in find isosceles triangles formed by the eyes and mouth.
Resumo:
The main purpose of this work is the development of computational tools in order to assist the on-line automatic detection of burn in the surface grinding process. Most of the parameters currently employed in the burning recognition (DPO, FKS, DPKS, DIFP, among others) do not incorporate routines for automatic selection of the grinding passes, therefore, requiring the user's interference for the choice of the active region. Several methods were employed in the passes extraction; however, those with the best results are presented in this article. Tests carried out in a surface-grinding machine have shown the success of the algorithms developed for pass extraction. Copyright © 2007 by ABCM.
Resumo:
This paper describes a program for the automatic generation of code for Intel's 8051 microcontroller. The code is generated from a place-transition Petri net specification. Our goal is to minimize programming time. The code generated by our program has been observed to exactly match the net model. It has also been observed that no change is needed to be made to the generated code for its compilation to the target architecture. © 2011 IFAC.
Resumo:
C-reactive protein (CRP) is an acute phase protein whose levels are increased in many disorders. There exists, in particular, a great deal of interest in the correlation between blood serum levels and the severity of risk for cardiovascular disease. A sensitive, label-free, non-amplified and reusable electrochemical impedimetric biosensor for the detection of CRP in blood serum was developed herein based on controlled and coverage optimised antibody immobilization on standard polycrystalline gold electrodes. Charge transfer resistance changes were highly target specific, linear with log. CRP. concentration across a 0.5-50. nM range and associated with a limit of detection of 176. pM. Significantly, the detection limits are better than those of current CRP clinical methods and the assays are potentially cheap, relatively automated, reusable, multiplexed and highly portable. The generated interfaces were capable not only of comfortably quantifying CRP across a clinically relevant range of concentrations but also of doing this in whole blood serum with interfaces that were, subsequently, reusable. The importance of optimising receptor layer resistance in maximising assay sensitivity is also detailed. © 2012.
Resumo:
The inelastic scattering of light, Raman scattering, presents a very low cross section. However, the signal can be amplified by several orders of magnitude, leading to the so-called surface-enhanced Raman scattering (SERS) phenomenon. Basically, the SERS effect is achieved when the target molecule (analyte) is adsorbed onto metallic nanoparticles, usually noble metals. This article presents an overview of the applications of SERS to cancer diagnosis and the detection of pesticides, explosives, and drugs (illicit and pharmacological). SERS is routinely applied nowadays to detect and identify analytes at very low concentrations, including for single-molecule detection. However, the application of SERS as an analytical tool requires reliable and reproducible SERS substrates, in terms of enhancement factors, which depends on the size, shape, and aggregation of the metallic nanoparticles. Therefore, the production of reliable and reproducible SERS substrates is a challenge in the field. Besides, the metallic nanoparticles can also induce changes in the system by possible interactions with the analyte under investigation, which must be taken into account. This review will present work in which, under certain specific experimental conditions, SERS has been analytically applied.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents a Computer Aided Diagnosis (CAD) system that automatically classifies microcalcifications detected on digital mammograms into one of the five types proposed by Michele Le Gal, a classification scheme that allows radiologists to determine whether a breast tumor is malignant or not without the need for surgeries. The developed system uses a combination of wavelets and Artificial Neural Networks (ANN) and is executed on an Altera DE2-115 Development Kit, a kit containing a Field-Programmable Gate Array (FPGA) that allows the system to be smaller, cheaper and more energy efficient. Results have shown that the system was able to correctly classify 96.67% of test samples, which can be used as a second opinion by radiologists in breast cancer early diagnosis. (C) 2013 The Authors. Published by Elsevier B.V.