929 resultados para area under the curve
Resumo:
BACKGROUND & AIMS It is not clear whether symptoms alone can be used to estimate the biologic activity of eosinophilic esophagitis (EoE). We aimed to evaluate whether symptoms can be used to identify patients with endoscopic and histologic features of remission. METHODS Between April 2011 and June 2014, we performed a prospective, observational study and recruited 269 consecutive adults with EoE (67% male; median age, 39 years old) in Switzerland and the United States. Patients first completed the validated symptom-based EoE activity index patient-reported outcome instrument and then underwent esophagogastroduodenoscopy with esophageal biopsy collection. Endoscopic and histologic findings were evaluated with a validated grading system and standardized instrument, respectively. Clinical remission was defined as symptom score <20 (range, 0-100); histologic remission was defined as a peak count of <20 eosinophils/mm(2) in a high-power field (corresponds to approximately <5 eosinophils/median high-power field); and endoscopic remission as absence of white exudates, moderate or severe rings, strictures, or combination of furrows and edema. We used receiver operating characteristic analysis to determine the best symptom score cutoff values for detection of remission. RESULTS Of the study subjects, 111 were in clinical remission (41.3%), 79 were in endoscopic remission (29.7%), and 75 were in histologic remission (27.9%). When the symptom score was used as a continuous variable, patients in endoscopic, histologic, and combined (endoscopic and histologic remission) remission were detected with area under the curve values of 0.67, 0.60, and 0.67, respectively. A symptom score of 20 identified patients in endoscopic remission with 65.1% accuracy and histologic remission with 62.1% accuracy; a symptom score of 15 identified patients with both types of remission with 67.7% accuracy. CONCLUSIONS In patients with EoE, endoscopic or histologic remission can be identified with only modest accuracy based on symptoms alone. At any given time, physicians cannot rely on lack of symptoms to make assumptions about lack of biologic disease activity in adults with EoE. ClinicalTrials.gov, Number: NCT00939263.
Resumo:
The aim of this study was to test the influence of different degrees of additional illumination on visual caries detection using the International Caries Detection and Assessment System (ICDAS). Two calibrated examiners assessed 139 occlusal surfaces of extracted permanent molars using a standard operation lamp with or without an additional headlamp providing three default brightness intensities. Histology served as the gold standard. Pooled data showed no differences in sensitivities. Specificities were not influenced by additional light. The area under the curve for the Marthaler classification D3 threshold was significantly lower when an additional strong headlamp was used (0.59 compared to 0.69-0.72 when reduced illumination intensities were used). One of the two examiners also had a significantly lower sensitivity for the D1 threshold when an additional headlamp was used. The use of additional white light led to a reduced detection of dentine lesions.
Resumo:
Endometriosis is a gynecologic disease that is characterized by nonspecific symptoms and invasive diagnostics. To date, there is no adequate noninvasive method for the diagnosis of endometriosis. Although more than 100 potential biomarkers have been investigated in blood and/or peritoneal fluid, none of these has proven useful in clinical practice. The aim to find a suitable panel of biomarkers that would allow noninvasive diagnosis thus remains of interest. We evaluated the concentrations of 16 cytokines and other secretory proteins in serum and peritoneal fluid of 58 women with ovarian endometriosis (cases) and 40 healthy women undergoing sterilization or patients with benign ovarian cysts (controls) using multiplexed double fluorescence-based immunometric assay platform and enzyme-linked immunosorbent assay. Significantly higher concentrations of glycodelin-A were shown in serum, and significantly higher levels of glycodelin-A, IL-6, and IL-8, and lower levels of leptin were measured in the peritoneal fluid of cases versus controls. In serum, the best performance was shown by models that included the ratio of leptin/glycodelin-A and the ratio of ficolin 2/glycodelin-A, whereas in the peritoneal fluid the best models included the ratio of biglycan/leptin, regulated on activation normal T-cell expressed and secreted/IL-6 and ficolin-2/glycodelin-A, and IL-8 per milligram of total protein, all in combination with age. The models using serum and peritoneal fluid distinguished between ovarian endometriosis patients and controls regardless of the menstrual cycle phase with relatively high sensitivity (72.5% to 84.2%), specificity (78.4% to 91.2%), and area under the curve (0.85 to 0.90).
Resumo:
BACKGROUND The choice of imaging techniques in patients with suspected coronary artery disease (CAD) varies between countries, regions, and hospitals. This prospective, multicenter, comparative effectiveness study was designed to assess the relative accuracy of commonly used imaging techniques for identifying patients with significant CAD. METHODS AND RESULTS A total of 475 patients with stable chest pain and intermediate likelihood of CAD underwent coronary computed tomographic angiography and stress myocardial perfusion imaging by single photon emission computed tomography or positron emission tomography, and ventricular wall motion imaging by stress echocardiography or cardiac magnetic resonance. If ≥1 test was abnormal, patients underwent invasive coronary angiography. Significant CAD was defined by invasive coronary angiography as >50% stenosis of the left main stem, >70% stenosis in a major coronary vessel, or 30% to 70% stenosis with fractional flow reserve ≤0.8. Significant CAD was present in 29% of patients. In a patient-based analysis, coronary computed tomographic angiography had the highest diagnostic accuracy, the area under the receiver operating characteristics curve being 0.91 (95% confidence interval, 0.88-0.94), sensitivity being 91%, and specificity being 92%. Myocardial perfusion imaging had good diagnostic accuracy (area under the curve, 0.74; confidence interval, 0.69-0.78), sensitivity 74%, and specificity 73%. Wall motion imaging had similar accuracy (area under the curve, 0.70; confidence interval, 0.65-0.75) but lower sensitivity (49%, P<0.001) and higher specificity (92%, P<0.001). The diagnostic accuracy of myocardial perfusion imaging and wall motion imaging were lower than that of coronary computed tomographic angiography (P<0.001). CONCLUSIONS In a multicenter European population of patients with stable chest pain and low prevalence of CAD, coronary computed tomographic angiography is more accurate than noninvasive functional testing for detecting significant CAD defined invasively. CLINICAL TRIAL REGISTRATION URL http://www.clinicaltrials.gov. Unique identifier: NCT00979199.
Resumo:
Purpose To this day, the slit lamp remains the first tool used by an ophthalmologist to examine patient eyes. Imaging of the retina poses, however, a variety of problems, namely a shallow depth of focus, reflections from the optical system, a small field of view and non-uniform illumination. For ophthalmologists, the use of slit lamp images for documentation and analysis purposes, however, remains extremely challenging due to large image artifacts. For this reason, we propose an automatic retinal slit lamp video mosaicking, which enlarges the field of view and reduces amount of noise and reflections, thus enhancing image quality. Methods Our method is composed of three parts: (i) viable content segmentation, (ii) global registration and (iii) image blending. Frame content is segmented using gradient boosting with custom pixel-wise features. Speeded-up robust features are used for finding pair-wise translations between frames with robust random sample consensus estimation and graph-based simultaneous localization and mapping for global bundle adjustment. Foreground-aware blending based on feathering merges video frames into comprehensive mosaics. Results Foreground is segmented successfully with an area under the curve of the receiver operating characteristic curve of 0.9557. Mosaicking results and state-of-the-art methods were compared and rated by ophthalmologists showing a strong preference for a large field of view provided by our method. Conclusions The proposed method for global registration of retinal slit lamp images of the retina into comprehensive mosaics improves over state-of-the-art methods and is preferred qualitatively.
Resumo:
Detecting lame cows is important in improving animal welfare. Automated tools are potentially useful to enable identification and monitoring of lame cows. The goals of this study were to evaluate the suitability of various physiological and behavioral parameters to automatically detect lameness in dairy cows housed in a cubicle barn. Lame cows suffering from a claw horn lesion (sole ulcer or white line disease) of one claw of the same hind limb (n=32; group L) and 10 nonlame healthy cows (group C) were included in this study. Lying and standing behavior at night by tridimensional accelerometers, weight distribution between hind limbs by the 4-scale weighing platform, feeding behavior at night by the nose band sensor, and heart activity by the Polar device (Polar Electro Oy, Kempele, Finland) were assessed. Either the entire data set or parts of the data collected over a 48-h period were used for statistical analysis, depending upon the parameter in question. The standing time at night over 12 h and the limb weight ratio (LWR) were significantly higher in group C as compared with group L, whereas the lying time at night over 12 h, the mean limb difference (△weight), and the standard deviation (SD) of the weight applied on the limb taking less weight were significantly lower in group C as compared with group L. No significant difference was noted between the groups for the parameters of heart activity and feeding behavior at night. The locomotion score of cows in group L was positively correlated with the lying time and △weight, whereas it was negatively correlated with LWR and SD. The highest sensitivity (0.97) for lameness detection was found for the parameter SD [specificity of 0.80 and an area under the curve (AUC) of 0.84]. The highest specificity (0.90) for lameness detection was present for Δweight (sensitivity=0.78; AUC=0.88) and LWR (sensitivity=0.81; AUC=0.87). The model considering the data of SD together with lying time at night was the best predictor of cows being lame, accounting for 40% of the variation in the likelihood of a cow being lame (sensitivity=0.94; specificity=0.80; AUC=0.86). In conclusion, the data derived from the 4-scale-weighing platform, either alone or combined with the lying time at night over 12 h, represent the most valuable parameters for automated identification of lame cows suffering from a claw horn lesion of one individual hind limb.
Resumo:
INTRODUCTION The aim of the study was to identify the appropriate level of Charlson comorbidity index (CCI) in older patients (>70 years) with high-risk prostate cancer (PCa) to achieve survival benefit following radical prostatectomy (RP). METHODS We retrospectively analyzed 1008 older patients (>70 years) who underwent RP with pelvic lymph node dissection for high-risk prostate cancer (preoperative prostate-specific antigen >20 ng/mL or clinical stage ≥T2c or Gleason ≥8) from 14 tertiary institutions between 1988 and 2014. The study population was further grouped into CCI < 2 and ≥2 for analysis. Survival rate for each group was estimated with Kaplan-Meier method and competitive risk Fine-Gray regression to estimate the best explanatory multivariable model. Area under the curve (AUC) and Akaike information criterion were used to identify ideal 'Cut off' for CCI. RESULTS The clinical and cancer characteristics were similar between the two groups. Comparison of the survival analysis using the Kaplan-Meier curve between two groups for non-cancer death and survival estimations for 5 and 10 years shows significant worst outcomes for patients with CCI ≥ 2. In multivariate model to decide the appropriate CCI cut-off point, we found CCI 2 has better AUC and p value in log rank test. CONCLUSION Older patients with fewer comorbidities harboring high-risk PCa appears to benefit from RP. Sicker patients are more likely to die due to non-prostate cancer-related causes and are less likely to benefit from RP.
Resumo:
MRSI grids frequently show spectra with poor quality, mainly because of the high sensitivity of MRS to field inhomogeneities. These poor quality spectra are prone to quantification and/or interpretation errors that can have a significant impact on the clinical use of spectroscopic data. Therefore, quality control of the spectra should always precede their clinical use. When performed manually, quality assessment of MRSI spectra is not only a tedious and time-consuming task, but is also affected by human subjectivity. Consequently, automatic, fast and reliable methods for spectral quality assessment are of utmost interest. In this article, we present a new random forest-based method for automatic quality assessment of (1) H MRSI brain spectra, which uses a new set of MRS signal features. The random forest classifier was trained on spectra from 40 MRSI grids that were classified as acceptable or non-acceptable by two expert spectroscopists. To account for the effects of intra-rater reliability, each spectrum was rated for quality three times by each rater. The automatic method classified these spectra with an area under the curve (AUC) of 0.976. Furthermore, in the subset of spectra containing only the cases that were classified every time in the same way by the spectroscopists, an AUC of 0.998 was obtained. Feature importance for the classification was also evaluated. Frequency domain skewness and kurtosis, as well as time domain signal-to-noise ratios (SNRs) in the ranges 50-75 ms and 75-100 ms, were the most important features. Given that the method is able to assess a whole MRSI grid faster than a spectroscopist (approximately 3 s versus approximately 3 min), and without loss of accuracy (agreement between classifier trained with just one session and any of the other labelling sessions, 89.88%; agreement between any two labelling sessions, 89.03%), the authors suggest its implementation in the clinical routine. The method presented in this article was implemented in jMRUI's SpectrIm plugin. Copyright © 2016 John Wiley & Sons, Ltd.
Resumo:
OBJECTIVE Growth hormone (GH) has a strong lipolytic action and its secretion is increased during exercise. Data on fuel metabolism and its hormonal regulation during prolonged exercise in patients with growth hormone deficiency (GHD) is scarce. This study aimed at evaluating the hormonal and metabolic response during aerobic exercise in GHD patients. DESIGN Ten patients with confirmed GHD and 10 healthy control individuals (CI) matched for age, sex, BMI, and waist performed a spiroergometric test to determine exercise capacity (VO2max). Throughout a subsequent 120-minute exercise on an ergometer at 50% of individual VO2max free fatty acids (FFA), glucose, GH, cortisol, catecholamines and insulin were measured. Additionally substrate oxidation assessed by indirect calorimetry was determined at begin and end of exercise. RESULTS Exercise capacity was lower in GHD compared to CI (VO2max 35.5±7.4 vs 41.5±5.5ml/min∗kg, p=0.05). GH area under the curve (AUC-GH), peak-GH and peak-FFA were lower in GHD patients during exercise compared to CI (AUC-GH 100±93.2 vs 908.6±623.7ng∗min/ml, p<0.001; peak-GH 1.5±1.53 vs 12.57±9.36ng/ml, p<0.001, peak-FFA 1.01±0.43 vs 1.51±0.56mmol/l, p=0.036, respectively). There were no significant differences for insulin, cortisol, catecholamines and glucose. Fat oxidation at the end of exercise was higher in CI compared to GHD patients (295.7±73.9 vs 187.82±103.8kcal/h, p=0.025). CONCLUSION A reduced availability of FFA during a 2-hour aerobic exercise and a reduced fat oxidation at the end of exercise may contribute to the decreased exercise capacity in GHD patients. Catecholamines and cortisol do not compensate for the lack of the lipolytic action of GH in patients with GHD.
Resumo:
Symptoms of primary ciliary dyskinesia (PCD) are nonspecific and guidance on whom to refer for testing is limited. Diagnostic tests for PCD are highly specialised, requiring expensive equipment and experienced PCD scientists. This study aims to develop a practical clinical diagnostic tool to identify patients requiring testing.Patients consecutively referred for testing were studied. Information readily obtained from patient history was correlated with diagnostic outcome. Using logistic regression, the predictive performance of the best model was tested by receiver operating characteristic curve analyses. The model was simplified into a practical tool (PICADAR) and externally validated in a second diagnostic centre.Of 641 referrals with a definitive diagnostic outcome, 75 (12%) were positive. PICADAR applies to patients with persistent wet cough and has seven predictive parameters: full-term gestation, neonatal chest symptoms, neonatal intensive care admittance, chronic rhinitis, ear symptoms, situs inversus and congenital cardiac defect. Sensitivity and specificity of the tool were 0.90 and 0.75 for a cut-off score of 5 points. Area under the curve for the internally and externally validated tool was 0.91 and 0.87, respectively.PICADAR represents a simple diagnostic clinical prediction rule with good accuracy and validity, ready for testing in respiratory centres referring to PCD centres.
Resumo:
Critically ill and injured patients require pain relief and sedation to reduce the body's stress response and to facilitate painful diagnostic and therapeutic procedures. Presently, the level of sedation and analgesia is guided by the use of clinical scores which can be unreliable. There is therefore, a need for an objective measure of sedation and analgesia. The Bispectral Index (BIS) and Patient State Index (PSI) were recently introduced into clinical practice as objective measures of the depth of analgesia and sedation. ^ Aim. To compare the different measures of sedation and analgesia (BIS and PSI) to the standard and commonly used modified Ramsay Score (MRS) and determine if the monitors can be used interchangeably. ^ Methods. MRS, BIS and PSI values were obtained in 50 postoperative cardiac surgery patients requiring analgesia and sedation from June to December 2004. The MRS, BIS and PSI values were assessed hourly for up to 6-h by a single observer. ^ The relationship between BIS and PSI values were explored using scatter plots and correlation between MRS, BIS and PSI was determined using Spearman's correlation coefficient. Intra-class correlation (ICC) was used to determine the inter-rater reliability of MRS, BIS and PSI. Kappa statistics was used to further evaluate the agreement between BIS and PSI at light, moderate and deep levels of sedation. ^ Results. There was a positive correlation between BIS and PSI values (Rho = 0.731, p<0.001). Intra-class correlation between BIS and PSI was 0.58, MRS and BIS 0.43 and MRS and PSI 0.27. Using Kappa statistics, agreement between MRS and BIS was 0.35 (95% CI: 0.27–0.43) and for MRS and PSI was 0.21 (95% CI: 0.15–0.28). The kappa statistic for BIS and PSI was 0.45 (95% CI: 0.37–0.52). Receiver operating characteristics (ROC) curves constructed to detect undersedation indicated an area under the curve (AUC) of 0.91 (95% CI = 0.87 to 0.94) for the BIS and 0.84 (95% CI = 0.79 to 0.88) for the PSI. For detection of oversedation, AUC for the BIS was 0.89 (95% CI = 0.84 to 0.92) and 0.80 (95% CI = 0.75 to 0.85) for the PSI. ^ Conclusions. There is a statistically significant positive correlation between the BIS and PSI but poor correlation and poor test agreement between the MRS and BIS as well as MRS and PSI. Both the BIS and PSI demonstrated a high level of prediction for undersedation and oversedation; however, the BIS and PSI can not be considered interchangeable monitors of sedation. ^
Resumo:
INTRODUÇÃO E OBJETIVO: A estenose de junção ureteropélvica (EJUP) é importante causa de obstrução do trato urinário e pode levar a deterioração progressiva da função renal. Há espaço para o aprimoramento de novos métodos diagnósticos capazes de discriminar hidronefrose e uropatia obstrutiva. Acredita-se que os biomarcadores urinários podem fornecer indícios de lesão renal precoce na obstrução urinária. Neste contexto, KIM-1 pode elevar-se na urina por lesão tubular proximal, NGAL por lesão no túbulo proximal, distal ou alça de Henle, CA19-9 por produção excessiva no túbulo obstruído e ?2-microglobulina (beta2M) por injúria ao glomérulo ou ao túbulo proximal. O objetivo do presente estudo foi avaliar as propriedades diagnósticas dos biomarcadores urinários citados em adultos com EJUP, sendo o primeiro estudo na literatura a avaliar tais moléculas nesta população. MÉTODOS: Foram estudados de modo prospectivo pacientes consecutivos acima de 18 anos com diagnóstico de EJUP submetidos a pieloplastia videolaparoscópica de dezembro de 2013 a fevereiro de 2015. Foram excluídos do estudo pacientes com EJUP bilateral, rim contralateral patológico, EJUP em rim único, antecedentes de tratamento cirúrgico para estenose de JUP ou taxa de filtração glomerular inferior a 60 ml/min/1,73m2. Cada paciente forneceu quatro amostras de urina para medição de biomarcadores, uma no pré-operatório e outras com 1, 3 e 6 meses de seguimento pós-operatório. O grupo controle foi constituído por voluntários saudáveis sem hidronefrose à ultrassonografia. RESULTADOS: Foram incluídos 47 pacientes com idade média de 38,6 ± 12,7 anos (intervalo 19 a 64 anos), sendo 17 (36,2%) do sexo masculino e 30 (62,8%) do sexo feminino. O grupo controle foi composto por 40 indivíduos semelhantes ao grupo com EJUP no que concerne idade (p = 0,95) e sexo (p = 0,82). KIM-1 foi o marcador com melhores propriedades diagnósticas, apresentando área sob a curva (AUC) de 0,79 (95% CI 0,70 a 0,89). O NGAL, por sua vez, teve AUC de 0,71 (95% CI 0,61 a 0,83), CA19- 9 teve AUC de 0,70 (95% CI 0,60 a 0,81) e (beta2M) apresentou AUC de 0,61 (95% CI 0,50 a 0,73), sendo o único biomarcador com propriedades inadequadas neste cenário. O KIM-1 foi o marcador mais sensível com o ponto de corte 170,4 pg/mg de creatinina (sensibilidade 91,4%, especificidade 59,1%) e o CA 19-9 o mais específico para o ponto de corte de 51,3 U/mg de creatinina (sensibilidade 48,9%, especificidade 88,0%), enquanto o NGAL foi o que apresentou maior queda após desobstrução, com 90,0% dos pacientes apresentando clareamento superior a 50%. CONCLUSÕES: A avaliação dos biomarcadores urinários é útil no diagnóstico de obstrução em adultos com EJUP submetidos a pieloplastia videolaparoscópica. O KIM-1 foi o marcador mais sensível e o CA 19-9 o mais específico, enquanto o NGAL foi o que apresentou maior que com a desobstrução. Houve queda das concentrações dos marcadores após pieloplastia no período estudado. O papel exato dos biomarcadores urinários no cenário de obstrução em adultos deve ser mais amplamente investigado
Resumo:
In this study, we compared contrast-enhanced ultrasound perfusion imaging with magnetic resonance perfusion-weighted imaging or perfusion computed tomography for detecting normo-, hypo-, and nonperfused brain areas in acute middle cerebral artery stroke. We performed high mechanical index contrast-enhanced ultrasound perfusion imaging in 30 patients. Time-to-peak intensity of 10 ischemic regions of interests was compared to four standardized nonischemic regions of interests of the same patient. A time-to-peak >3 s (ultrasound perfusion imaging) or >4 s (perfusion computed tomography and magnetic resonance perfusion) defined hypoperfusion. In 16 patients, 98 of 160 ultrasound perfusion imaging regions of interests of the ischemic hemisphere were classified as normal, and 52 as hypoperfused or nonperfused. Ten regions of interests were excluded due to artifacts. There was a significant correlation of the ultrasound perfusion imaging and magnetic resonance perfusion or perfusion computed tomography (Pearson`s chi-squared test 79.119, p < 0.001) (OR 0.1065, 95% CI 0.06-0.18). No perfusion in ultrasound perfusion imaging (18 regions of interests) correlated highly with diffusion restriction on magnetic resonance imaging (Pearson's chi-squared test 42.307, p < 0.001). Analysis of receiver operating characteristics proved a high sensitivity of ultrasound perfusion imaging in the diagnosis of hypoperfused area under the curve, (AUC = 0.917; p < 0.001) and nonperfused (AUC = 0.830; p < 0.001) tissue in comparison with perfusion computed tomography and magnetic resonance perfusion. We present a proof of concept in determining normo-, hypo-, and nonperfused tissue in acute stroke by advanced contrast-enhanced ultrasound perfusion imaging.
Resumo:
REASONS FOR PERFORMING STUDY: Failure of transfer of passive immunity (FTPI) in foals is associated with a risk of infection and death. The current diagnostic gold standard is quantification of immunoglobulins using radial immunodiffusion (IgG-RID). Routine diagnosis is often performed using semi-quantitative tests. Concentrations of serum electrophoretic gamma globulins (EGG) and total globulins may be useful to assess FTPI, but few studies have investigated their use. OBJECTIVES: To assess agreement between IgG-RID and EGG, and evaluate the accuracy of total globulin concentration to diagnose FTPI based on both IgG-RID and EGG. STUDY DESIGN: Prospective study. METHODS: 360 serum samples were harvested at 6-24 hours post natum from 60 German Warmblood foals. Concentrations of EGG, IgG-RID and total globulin concentration (calculated from total proteins and albumin) were measured. Agreement between EGG and IgG-RID was assessed using Bland-Altman plots and Passing-Bablok regression. The accuracy of total globulin concentration was assessed using rank correlation and ROC curve analysis. RESULTS: Good agreement was found with slightly lower EGG than IgG-RID concentrations (Bland-Altman systemic bias, -1.9 g/L) which was more pronounced at higher concentrations (regression equation: IgG-RID = -0.78 +1.28xEGG). Correlations between total globulin concentration and EGG, and total globulin concentration and IgG-RID were 0.93 and 0.79, respectively. The area under the curve was 0.982 and 0.952 for EGG <4 g/L and <8 g/L, and 0.953 and 0.899 for IgG-RID <4 g/L and <8 g/L. Sensitivities and specificities of total globulin concentration in the diagnosis of FTPI were comparable to commonly used screening tests, but cut-offs could be selected to achieve sensitivities of >95% with 71.2% (IgG-RID) and 90.5% (EGG) specificity for <4 g/L, and >90% with 66.0% (IgG-RID) and 87.9% (EGG) specificity for <8 g/L. CONCLUSIONS: There is good agreement between EGG and IgG-RID, with slightly more conservative estimates of immunoglobulins obtained using EGG. Total globulins may be a useful and economic quantitative screening test with cut-offs achieving high sensitivities, but analyser-specific cut-offs may be necessary. This article is protected by copyright. All rights reserved. KEYWORDS: IgG; electrophoresis; foal; globulins; horse; radial immunodiffusion. This article is protected by copyright. All rights reserved.
Resumo:
Objective To determine the pharmacokinetics of carboplatin in sulphur-crested cockatoos, so that its use in clinical studies in birds can be considered. Design A pharmacokinetic study of carboplatin, following a single intravenous (IV) or intraosseus (10) infusion over 3 min, was performed in six healthy sulphur-crested cockatoos (Cacatua galerita). Procedure Birds were anaesthetised and a jugular vein cannulated for blood collection. Carboplatin (5 mg/kg) was infused over 3 min by the IV route in four birds via the contralateral jugular vein, and by the 10 route in two birds via the ulna. Serial blood samples were collected for 96 h after initiation of the infusion. Tissue samples from 11 organs were obtained at necropsy, 96 h after carboplatin administration. Total Pt and filterable Pt in plasma and tissue Pt concentrations were assayed by inductively coupled plasma-mass spectrometry. A noncompartmental pharmacokinetic analysis was performed on the plasma data. Results The mean +/- SD for the C-max of filterable Pt was 27.3 +/- 4.06 mg/L and in all six birds occurred at the end of the 3 min infusion, thenceforth declining exponentially over the next 6 h to an average concentration of 0.128 +/- 0.065 mg/L. The terminal half-life (T-1/2) was 1.0 +/- 0.17 h, the systemic clearance (CI) was 5.50 +/- 1.06 mL/min/kg and the volume of distribution (Vss) was 0.378 +/- 0.073 L/kg. The extrapolated area under the curve (AUC(0-x)) was 0.903 +/- 0.127 mg/mL.min; the area extrapolated past the last (6 h) data point to infinite time averaged only 1.25% of the total AUC(0-x). The kidneys had the greatest accumulation of Pt (7.04 +/- 3.006 mug/g), followed by the liver (3.08 +/- 1.785 mug/g DM). Conclusions and clinical relevance Carboplatin infusion in sulphur-crested cockatoos produced mild, transient alimentary tract signs and the Pt plasma concentration was similar whether carboplatin was given intravenously or intraosseously. Filterable plasma Pt concentrations for carboplatin persisted longer than for cisplatin, due mostly to the difference in systemic clearance between these drugs in sulphur-crested cockatoos. The distribution of tissue Pt after carboplatin administration was similar to that reported for cisplatin in sulphur-crested cockatoos. Despite anatomical, physiological and biochemical differences among animal species, the pharmacokinetic disposition of filterable Pt in the sulphur-crested cockatoo shares some features with the kinetics reported previously in other animals and human beings.