955 resultados para analytical methods
Resumo:
The styrene levels of polystyrene (PS) glasses from the most consumed brands of disposable glasses intended for water and coffee in Brazil were determined. A GC-FID method was developed and validated, showing good precision and accuracy. The method was successfully used to determine styrene in 11 PS glass brands. The styrene levels ranged from 1.68 to 43.69 mg/100 g glass, depending on the kind of polymer, thickness, and glass brand. It could be used to control the content of styrene in the polymer. The migration of styrene from the glasses into water and 20 % ethanol was not detected.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
The present investigation reports the synthesis, characterization, and adsorption properties of a new nanomaterial based on organomodified silsesquioxane nanocages. The adsorption isotherms for CuCl,, CoCl2, ZnCl2, NiCl2, and FeCl3 from ethanol solutions were performed by using the batchwise method. The equilibrium condition is reached very quickly (3 min), indicating that the adsorption sites are well exposed. The results obtained in the flow experiments, showed a recovery of ca. 100% of the metal ions adsorbed in a column packed with 2 g of the nanomaterial, using 5 mL of 1.0 mol L-1 HCl solution as eluent. The sorption-desorption of the metal ions made possible the development of a method for preconcentration and determination of metal ions at trace level in commercial ethanol, used as fuel for car engines. The values determined by recommended method for plants 1, 2, and 3 indicated an amount of copper of 51, 60, and 78 mu g L-1, and of iron of 2, 15, and 13 mu g L-1, respectively. These values are very close to those determined by conventional analytical methods. Thus, these similar values demonstrated the accuracy of the determination by recommended method.
Resumo:
Soil contamination by pesticides is an environmental problem that needs to be monitored and avoided. However, the lack of fast, accurate and low cost analytical methods for discovering residual pesticide in complex matrices, such as soil, is a problem still unresolved. This problem needs to be solved before we are able to assess the quality of environmental samples. The intensive use of pesticides has increased since the 60s, because the dependence of their use, causing biological imbalances and promoting resistance and recurrence of high populations of pests and pathogens (upwelling). This has contributed to the appearance of new pests that were previously under natural control. To develop analytical methods that are able to quantify residues pesticide in complex environment. It is still a challenge for many laboratories. The integration of two analytical methods one ecotoxicological and another chemical demonstrates the potential for environmental analysis of methamidophos. The aim of this study was to evaluate an ecotoxicological method as "screening" analytical methamidophos in the soil and perform analytical confirmation in the samples of the concentration of the analyte by chemical method LC-MS/MS In this work we tested two soils: a clayey and sandy, both in contact with the kinetic methamidophos model followed pseudo-second order. The clay soil showed higher absorption of methamidophos and followed the Freundlich model, while the sandy, the Langmuir model. The chemical method was validated LC-MS/MS satisfactory, showing all parameters of linearity, range, precision, accuracy, and sensitivity adequate. In chronic ecotoxicological tests with C. dubia, the NOEC was 4.93 and 3.24 for ng L-1 of methamidophos to elutriate assays of sandy and clay soils, respectively. The method for ecotoxicological levels was more sensitive than LC-MS/MS detection of methamidophos, loamy and sandy soils. However, decreasing the concentration of the standard for analytical methamidophos and adjusting for the validation conditions chemical acquires a limit of quantification (LOQ) in ng L-1, consistent with the provisions of ecotoxicological test. The methods described should be used as an analytical tool for methamidophos in soil, and the ecotoxicological analysis can be used as a "screening" and LC-MS/MS as confirmatory analysis of the analyte molecule, confirming the objectives of this work
Resumo:
The development of more selective and sensitive analytical methods is of great importance in different areas of knowledge, covering, for example, food, biotechnological, environmental and pharmaceutical sectors. The study aimed to employ the technique electroanalytical differential pulse voltammetry (DPV) as an innovative and promising alternative for identification and quantification of organic compounds. The organic compounds were investigated in this study oxalic acid (OA) and folic acid (FA). The electrochemical oxidation of oxalic acid has been extensively studied as a model reaction in the boundary between the organic and inorganic electrochemistry. Since the AF, an essential vitamin for cell multiplication in all tissues, which is essential for DNA synthesis. The AF has been investigated using analytical techniques, liquid chromatography and molecular absorption spectrophotometry. The results obtained during the experimental procedure indicated that the process of electrochemical oxidation of oxalic acid is strongly dependent on the nature of the anode material and the oxidation mechanism, which affects their detection. Efficient removal was observed in Ti/PbO2 anodes, graphite, BDD and Pt 90, 85, 80 and 78% respectively. It was also shown that the DPV employing glassy carbon electrode offers a fast, simple, reliable and economical way to determine the AO during the process of electrochemical oxidation. Furthermore, electroanalytical methods are more expensive than commonly used chromatographic analysis and other instrumental methods involving toxic reagents and higher cost. Compared with the classical method of titration and DPV could be a good fit, confidence intervals and detection limits confirming the applicability of electroanalytical technique for monitoring the degradation of oxalic acid. For the study of AF was investigated the electrocatalytic activity of the carbon paste electrode for identification and quantification in pharmaceutical formulations by applying the DPV. The results obtained during the experimental procedure showed an irreversible oxidation peak at 9.1 V characteristic of FA. The carbon paste sensor showed low detection limit of 5.683×10−8 mol L-1 reducing matrix effects. The spectrophotometric analysis showed lower concentrations of HF compared with those obtained by HPLC and DPV. The levels of AF were obtained according to the methodology proposed by the Brazilian Pharmacopoeia. The electroanalytical method (DPV) proposed is cheaper than GC analysis commonly used by the pharmaceutical industry. The results demonstrated the potential of these electroanalytical techniques for future applications in environmental, chemical and biological sensors
Resumo:
Disposal of tons of sludge produced daily by sewage treatment plants in large cities is a serious problem. Because recycling and application in agriculture have been proposed, the Brazilian National Environmental Council (CONAMA, 2006) issued a legal norm that regulates the use of the sewage sludge (SS) in crops. Due to the complex chemical nature of such products, characterization by analytical methods for health and environmental risk assessment has severe limitations. To overcome such limitations, it is necessary to (1) assess the toxicological potential of SS and (2) identify possible adverse effects in vivo in order to provide critical information for future environmental regulations. The present study was conducted to determine the potential toxicity of SS obtained from a representative urban treatment plant located in the São Paulo State, Brazil. Male and female Wistar rats were fed ad libitum a pelleted diet containing varying amounts of SS. No relevant clinical, hematological, urinary, or gross organ morphological alterations were observed in both genders of rats orally exposed to SS at up to 3.8 g/kg/d for 90 d. Sewage slude produced increased incidence of centrilobular hepatocyte hyperplasia at the high dose and significantly increased aspartate aminotransferease (AST) activities at all doses in both genders. Although the present data indicate some liver involvement, these alterations were considered adaptative and not toxicologically relevant, as the responses were relatively mild, not dose dependent, and no other parameters were markedly affected. The present results may contribute to the establishment of protocols for potential usage in SS agricultural soil application.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
This paper presents a simple, fast, and sensitive method to determine zinc in samples of feces and fish feed by electrothermal atomic absorption spectrometry through the direct introduction of slurries of the samples into the spectrometer's graphite tube. The procedure is based on the injection of 10 mu L of an acidified aqueous solution containing 0.50% w/v of feces or feed and 0.50% v/v HNO(3) into graphite tube. The limits of detection and quantification calculated for 20 readings of the blank of the standard slurries (0.50% w/v of feces or feed devoid of zinc) were 0.04 and 0.13 mu g L(-1) for the standard feces slurries and 0.05 and 0.17 mu g L(-1) for the standard feed slurries. The proposed method was applied in studies of digestibility of zinc in different fish feeds, and their results proved compatible with that obtained from samples mineralized by acid digestion using microwave oven.
Resumo:
Electrochemical processes in industrial effluents have been studied as a means to obtain higher efficiency in wastewater treatment. Heterogeneous photocatalysis appears as a low-cost alternative through the use of lower wattage lamps and thermal TiO2 films. Photocatalysis became a clean process for water treatment due to hydroxyl radicals generated on semiconductor surface. Such radicals are able to degrade several organic compounds. This study used different electrodes and analytical methods for degradation of phenol molecules to reduce treatment costs, improve efficiency, and identify compounds formed during the decomposition of phenolic molecules. Thermal growth of TiO2 film was observed on the titanium electrode in rutile form. Application of an electrical potential on the Ti/TiO2 working electrode increases efficiency in reducing concentration of phenol after photocatalytic treatment. Still, high energy radiation (UVC) showed best degradation rates in photolytic process. Different compounds formed during the degradation of phenol were also identified in the UVC-PE treatment.
Resumo:
Vegetable oils are important sources of essential fatty acids. It is, therefore, important to characterize plant species that can be used as new oil sources. This study aimed to characterize the oils from guariroba (Syagrus oleracea), jeriva (Syagrus romanzoffiana), and macauba (Acrocomia aculeata). The physicochemical characterization was performed using official analytical methods for oils and fats, free fatty acids, peroxide value, refractive index, iodine value, saponification number, and unsaponifiable matter. The oxidative stability was determined using the Rancimat at 110 degrees C. The fatty acid composition was performed by gas chromatography. The results were submitted to Tukey's test for the medium to 5% using the ESTAT program. The pulp oils were more unsaturated than kernel oils, as evidenced by the higher refractive index and iodine value, especially the macauba pulp oil which gave 1.4556 and 80 g I(2)/100 g, respectively, for these indices. The kernel oils were less altered by oxidative process and had high induction period, free fatty acids below 0.5%, and peroxide value around 0.19 meq/kg. The guariroba kernel oil showed the largest induction period, 91.82 h.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Muitos métodos analíticos estão sendo desenvolvidos visando à determinação de contaminantes orgânicos, especialmente alteradores endócrinos. Tais métodos baseiam-se geralmente na extração em fase sólida (SPE) seguida por determinação cromatográfica (CG ou HPLC). No presente trabalho utilizou-se ferramentas quimiométricas no processo de SPE para avaliar os principais fatores que influenciam tal processo e as interações entre os mesmos. Foram analisadas matrizes de água subterrânea fortificada com hormônios (17 b estradiol, estrona e 17 b etinilestradiol) e a determinação analítica foi feita por HPLC/Fluorescência. Um planejamento fatorial completo foi utilizado. Os fatores escolhidos incluíram: condicionamento da fase sólida, concentração dos analitos, volume da amostra e solvente de eluição. As melhores condições obtidas foram: 500 mL da amostra, condicionamento da fase sólida (C18) com acetona (4mL), metanol (6 mL) e água pH 3(10 mL), e eluição dos analitos com 4 mL de acetona.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)