964 resultados para Visual-system


Relevância:

40.00% 40.00%

Publicador:

Resumo:

Working memory is the process of actively maintaining a representation of information for a brief period of time so that it is available for use. In monkeys, visual working memory involves the concerted activity of a distributed neural system, including posterior areas in visual cortex and anterior areas in prefrontal cortex. Within visual cortex, ventral stream areas are selectively involved in object vision, whereas dorsal stream areas are selectively involved in spatial vision. This domain specificity appears to extend forward into prefrontal cortex, with ventrolateral areas involved mainly in working memory for objects and dorsolateral areas involved mainly in working memory for spatial locations. The organization of this distributed neural system for working memory in monkeys appears to be conserved in humans, though some differences between the two species exist. In humans, as compared with monkeys, areas specialized for object vision in the ventral stream have a more inferior location in temporal cortex, whereas areas specialized for spatial vision in the dorsal stream have a more superior location in parietal cortex. Displacement of both sets of visual areas away from the posterior perisylvian cortex may be related to the emergence of language over the course of brain evolution. Whereas areas specialized for object working memory in humans and monkeys are similarly located in ventrolateral prefrontal cortex, those specialized for spatial working memory occupy a more superior and posterior location within dorsal prefrontal cortex in humans than in monkeys. As in posterior cortex, this displacement in frontal cortex also may be related to the emergence of new areas to serve distinctively human cognitive abilities.

Relevância:

40.00% 40.00%

Publicador:

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Includes bibliographic references (216).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

This paper presents a case study of the use of a visual interactive modelling system to investigate issues involved in the management of a hospital ward. Visual Interactive Modelling systems are seen to offer the learner the opportunity to explore operational management issues from a varied perspective and to provide an interactive system in which the learner receives feedback on the consequences of their actions. However to maximise the potential learning experience for a student requires the recognition that they require task structure which helps them to understand the concepts involved. These factors can be incorporated into the visual interactive model by providing an interface customised to guide the student through the experimentation. Recent developments of VIM systems in terms of their connectivity with the programming language Visual Basic facilitates this customisation.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Investigates the degree of global standardisation of a corporate visual identity system (CVIS) in multinational operations. A special emphasis of this research is accorded to UK companies operating in Malaysia. In particular, the study seeks to reveal the reasons for developing a standardised CVIS; the behavioural issues associated with CVIS; and the determination in selecting a graphic design agency. The findings of the research revealed that multinational corporations in an increasingly corporate environment adopted a standardised CVIS for several reasons, including, aiding the sale of products and services, creating an attractive environment for hiring employees, and increasing the company’s stature and presence. Further findings show that the interest in global identity was stimulated by global restructuring, merger or acquisition. The above trends help explain why increased focus has been accorded to CVIS over the past five years by many UK companies operating in Malaysia. Additional findings reveal that both the UK design agencies and in-house design department are used in the development of the firms’ CVIS.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Multiple system atrophy (MSA) is a rare movement disorder and a member of a group of neurodegenerative diseases, which include Parkinson’s disease (PD) and progressive supranuclear palsy (PSP), and referred to as the ‘parkinsonian syndromes’. Although primarily a neurological disorder, patients with MSA may also develop visual signs and symptoms that could be useful in differential diagnosis. In addition, the eye-care practitioner may contribute to the management of visual problems of MSA patients and therefore, help to improve quality of life. This second article in the series considers the visual signs and symptoms of MSA with special reference to those features most useful in differential diagnosis of the parkinsonian syndromes.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Multiple system atrophy (MSA) is a rare movement disorder and a member of the 'parkinsonian syndromes', which also include Parkinson's disease (PD), progressive supranuclear palsy (PSP), dementia with Lewy bodies (DLB) and corticobasal degeneration (CBD). Multiple system atrophy is a complex syndrome, in which patients exhibit a variety of signs and symptoms, including parkinsonism, ataxia and autonomic dysfunction. It can be difficult to separate MSA from the other parkinsonian syndromes but if ocular signs and symptoms are present, they may aid differential diagnosis. Typical ocular features of MSA include blepharospasm, excessive square-wave jerks, mild to moderate hypometria of saccades, impaired vestibular-ocular reflex (VOR), nystagmus and impaired event-related evoked potentials. Less typical features include slowing of saccadic eye movements, the presence of vertical gaze palsy, visual hallucinations and an impaired electroretinogram (ERG). Aspects of primary vision such as visual acuity, colour vision or visual fields are usually unaffected. Management of the disease to deal with problems of walking, movement, daily tasks and speech problems is important in MSA. Optometrists can work in collaboration with the patient and health-care providers to identify and manage the patient's visual deficits. A more specific role for the optometrist is to correct vision to prevent falls and to monitor the anterior eye to prevent dry eye and control blepharospasm.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

It has been well documented that traffic accidents that can be avoided occur when the motorists miss or ignore traffic signs. With the attention of drivers getting diverted due to distractions like cell phone conversations, missing traffic signs has become more prevalent. Also, poor weather and other unfriendly driving conditions sometimes makes the motorists not to be alert all the time and see every traffic sign on the road. Besides, most cars do not have any form of traffic assistance. Because of heavy traffic and proliferation of traffic signs on the roads, there is a need for a system that assists the driver not to miss a traffic sign to reduce the probability of an accident. Since visual information is critical for driving, processed video signals from cameras have been chosen to assist drivers. These inexpensive cameras can be easily mounted on the automobile. The objective of the present investigation and the traffic system development is to recognize the traffic signs electronically and alert drivers. For the case study and the system development, five important and critical traffic signs have been selected. They are: STOP, NO ENTER, NO RIGHT TURN, NO LEFT TURN, and YIELD. The system was evaluated processing still pictures taken from the public roads, and the recognition results were presented in an analysis table to indicate the correct identifications and the false ones. The system reached the acceptable recognition rate of 80% for all five traffic signs. The processing rate was about three seconds. The capabilities of MATLAB, VLSI design platforms and coding have been used to generate a visual warning to complement the visual driver support system with a Field Programmable Gate Array (FPGA) on a XUP Virtex-II Pro Development System.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

When teaching students with visual impairments educators generally rely on tactile tools to depict visual mathematical topics. Tactile media, such as embossed paper and simple manipulable materials, are typically used to convey graphical information. Although these tools are easy to use and relatively inexpensive, they are solely tactile and are not modifiable. Dynamic and interactive technologies such as pin matrices and haptic pens are also commercially available, but tend to be more expensive and less intuitive. This study aims to bridge the gap between easy-to-use tactile tools and dynamic, interactive technologies in order to facilitate the haptic learning of mathematical concepts. We developed an haptic assistive device using a Tanvas electrostatic touchscreen that provides the user with multimodal (haptic, auditory, and visual) output. Three methodological steps comprise this research: 1) a systematic literature review of the state of the art in the design and testing of tactile and haptic assistive devices, 2) a user-centered system design, and 3) testing of the system’s effectiveness via a usability study. The electrostatic touchscreen exhibits promise as an assistive device for displaying visual mathematical elements via the haptic modality.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diabetic Retinopathy (DR) is a complication of diabetes that can lead to blindness if not readily discovered. Automated screening algorithms have the potential to improve identification of patients who need further medical attention. However, the identification of lesions must be accurate to be useful for clinical application. The bag-of-visual-words (BoVW) algorithm employs a maximum-margin classifier in a flexible framework that is able to detect the most common DR-related lesions such as microaneurysms, cotton-wool spots and hard exudates. BoVW allows to bypass the need for pre- and post-processing of the retinographic images, as well as the need of specific ad hoc techniques for identification of each type of lesion. An extensive evaluation of the BoVW model, using three large retinograph datasets (DR1, DR2 and Messidor) with different resolution and collected by different healthcare personnel, was performed. The results demonstrate that the BoVW classification approach can identify different lesions within an image without having to utilize different algorithms for each lesion reducing processing time and providing a more flexible diagnostic system. Our BoVW scheme is based on sparse low-level feature detection with a Speeded-Up Robust Features (SURF) local descriptor, and mid-level features based on semi-soft coding with max pooling. The best BoVW representation for retinal image classification was an area under the receiver operating characteristic curve (AUC-ROC) of 97.8% (exudates) and 93.5% (red lesions), applying a cross-dataset validation protocol. To assess the accuracy for detecting cases that require referral within one year, the sparse extraction technique associated with semi-soft coding and max pooling obtained an AUC of 94.2 ± 2.0%, outperforming current methods. Those results indicate that, for retinal image classification tasks in clinical practice, BoVW is equal and, in some instances, surpasses results obtained using dense detection (widely believed to be the best choice in many vision problems) for the low-level descriptors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To verify perceptions and conduct of students with visual impairment regarding devices and equipment utilized in schooling process. METHODS: A transversal descriptive study on a population of 12-year-old or older students in schooling process, affected by congenital or acquired visual impairment, inserted in the government teaching system of Campinas during the year 2000. An interview quiz, created based on an exploratory study was applied. RESULTS: A group of 26 students, 46% of them with low vision and 53.8% affected by blindness was obtained. Most of the students were from fundamental teaching courses (65.4%), studying in schools with classrooms provided with devices (73.1%). Among the resources used in reading and writing activities, 94.1% of the students reported they used the Braille system and 81.8% reported that the reading subject was dictated by a colleague. Most of the students with low vision wore glasses (91.7%), and 33.3% utilized a magnifying glass as optical devices. Among the non-optical devices, the most common were the environmental ones, getting closer to the blackboard (75.0%) and to the window (66.7%) for better lighting. CONCLUSIONS: It became evident that students with low vision eye-sight made use of devices meant for bearers of blindness, such as applying the Braille system. A reduced number of low vision students making use of optical and non-optical devices applicable to their problems were observed, indicating a probable unawareness of their visual potential and the appropriate devices to improve efficiency.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Universidade Estadual de Campinas . Faculdade de Educação Física