999 resultados para Variance monitoring


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE:: To examine the accuracy of brain multimodal monitoring-consisting of intracranial pressure, brain tissue PO2, and cerebral microdialysis-in detecting cerebral hypoperfusion in patients with severe traumatic brain injury. DESIGN:: Prospective single-center study. PATIENTS:: Patients with severe traumatic brain injury. SETTING:: Medico-surgical ICU, university hospital. INTERVENTION:: Intracranial pressure, brain tissue PO2, and cerebral microdialysis monitoring (right frontal lobe, apparently normal tissue) combined with cerebral blood flow measurements using perfusion CT. MEASUREMENTS AND MAIN RESULTS:: Cerebral blood flow was measured using perfusion CT in tissue area around intracranial monitoring (regional cerebral blood flow) and in bilateral supra-ventricular brain areas (global cerebral blood flow) and was matched to cerebral physiologic variables. The accuracy of intracranial monitoring to predict cerebral hypoperfusion (defined as an oligemic regional cerebral blood flow < 35 mL/100 g/min) was examined using area under the receiver-operating characteristic curves. Thirty perfusion CT scans (median, 27 hr [interquartile range, 20-45] after traumatic brain injury) were performed on 27 patients (age, 39 yr [24-54 yr]; Glasgow Coma Scale, 7 [6-8]; 24/27 [89%] with diffuse injury). Regional cerebral blood flow correlated significantly with global cerebral blood flow (Pearson r = 0.70, p < 0.01). Compared with normal regional cerebral blood flow (n = 16), low regional cerebral blood flow (n = 14) measurements had a higher proportion of samples with intracranial pressure more than 20 mm Hg (13% vs 30%), brain tissue PO2 less than 20 mm Hg (9% vs 20%), cerebral microdialysis glucose less than 1 mmol/L (22% vs 57%), and lactate/pyruvate ratio more than 40 (4% vs 14%; all p < 0.05). Compared with intracranial pressure monitoring alone (area under the receiver-operating characteristic curve, 0.74 [95% CI, 0.61-0.87]), monitoring intracranial pressure + brain tissue PO2 (area under the receiver-operating characteristic curve, 0.84 [0.74-0.93]) or intracranial pressure + brain tissue PO2+ cerebral microdialysis (area under the receiver-operating characteristic curve, 0.88 [0.79-0.96]) was significantly more accurate in predicting low regional cerebral blood flow (both p < 0.05). CONCLUSION:: Brain multimodal monitoring-including intracranial pressure, brain tissue PO2, and cerebral microdialysis-is more accurate than intracranial pressure monitoring alone in detecting cerebral hypoperfusion at the bedside in patients with severe traumatic brain injury and predominantly diffuse injury.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Skin-to-skin contact, or kangaroo mother care (KMC) has been shown to be efficacious in diminishing pain response to heel lance in full term and moderately preterm neonates. The purpose of this study was to determine if KMC would also be efficacious in very preterm neonates. METHODS: Preterm neonates (n = 61) between 28 0/7 and 31 6/7 weeks gestational age in three Level III NICU's in Canada comprised the sample. A single-blind randomized crossover design was employed. In the experimental condition, the infant was held in KMC for 15 minutes prior to and throughout heel lance procedure. In the control condition, the infant was in prone position swaddled in a blanket in the incubator. The primary outcome was the Premature Infant Pain Profile (PIPP), which is comprised of three facial actions, maximum heart rate, minimum oxygen saturation levels from baseline in 30-second blocks from heel lance. The secondary outcome was time to recover, defined as heart rate return to baseline. Continuous video, heart rate and oxygen saturation monitoring were recorded with event markers during the procedure and were subsequently analyzed. Repeated measures analysis-of-variance was employed to generate results. RESULTS: PIPP scores at 90 seconds post lance were significantly lower in the KMC condition (8.871 (95%CI 7.852-9.889) versus 10.677 (95%CI 9.563-11.792) p < .001) and non-significant mean differences ranging from 1.2 to1.8. favoring KMC condition at 30, 60 and 120 seconds. Time to recovery was significantly shorter, by a minute(123 seconds (95%CI 103-142) versus 193 seconds (95%CI 158-227). Facial actions were highly significantly lower across all points in time reaching a two-fold difference by 120 seconds post-lance and heart rate was significantly lower across the first 90 seconds in the KMC condition. CONCLUSION: Very preterm neonates appear to have endogenous mechanisms elicited through skin-to-skin maternal contact that decrease pain response, but not as powerfully as in older preterm neonates. The shorter recovery time in KMC is clinically important in helping maintain homeostasis. TRIAL REGISTRATION: (Current Controlled Trials) ISRCTN63551708.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper engages in an interdisciplinary survey of the current state of knowledge related to the theory, determinants and consequences of occupational safety and health (OSH). First, it synthesizes the available theoretical frameworks used by economists and psychologists to understand the issues related to the optimal provision of OSH in the labour market. Second, it reviews the academic literature investigating the correlates of a comprehensive set of OSH indicators, which portray the state of OSH infrastructure (social security expenditure, prevention, regulations), inputs (chemical and physical agents, ergonomics, working time, violence) and outcomes (injuries, illnesses, absenteeism, job satisfaction) within workplaces. Third, it explores the implications of the lack of OSH in terms of the economic and social costs that are entailed. Finally, the survey identifies areas of future research interests and suggests priorities for policy initiatives that can improve the health and safety of workers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Various methodologies in economic literature have been used to analyse the international hydrocarbon retail sector. Nevertheless at a Spanish level these studies are much more recent and most conclude that generally there is no effective competition present in this market, regardless of the approach used. In this paper, in order to analyse the price levels in the Spanish petrol market, our starting hypothesis is that in uncompetitive markets the prices are higher and the standard deviation is lower. We use weekly retail petrol price data from the ten biggest Spanish cities, and apply Markov chains to fill the missing values for petrol 95 and diesel, and we also employ a variance filter. We conclude that this market demonstrates reduced price dispersion, regardless of brand or city.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We provide field experimental evidence of the effects of monitoring in a context where productivity is multi-dimensional and only one dimension is monitored and incentivised. We hire students to do a job for us. The job consists of identifying euro coins. We study the effects of monitoring and penalising mistakes on work quality, and evaluate spillovers on non- incentivised dimensions of productivity (punctuality and theft). We .nd that monitoring improves work quality only if incentives are large, but reduces punctuality substantially irrespectively of the size of incentives. Monitoring does not affect theft, with ten per cent of participants stealing overall. Our setting also allows us to disentangle between possible theoretical mechanisms driving the adverse effects of monitoring. Our .ndings are supportive of a reciprocity mechanism, whereby workers retaliate for being distrusted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Durant les dernières années, les méthodes électriques ont souvent été utilisées pour l'investigation des structures de subsurface. L'imagerie électrique (Electrical Resistivity Tomography, ERT) est une technique de prospection non-invasive et spatialement intégrée. La méthode ERT a subi des améliorations significatives avec le développement de nouveaux algorithmes d'inversion et le perfectionnement des techniques d'acquisition. La technologie multicanale et les ordinateurs de dernière génération permettent la collecte et le traitement de données en quelques heures. Les domaines d'application sont nombreux et divers: géologie et hydrogéologie, génie civil et géotechnique, archéologie et études environnementales. En particulier, les méthodes électriques sont souvent employées dans l'étude hydrologique de la zone vadose. Le but de ce travail est le développement d'un système de monitorage 3D automatique, non- invasif, fiable, peu coûteux, basé sur une technique multicanale et approprié pour suivre les variations de résistivité électrique dans le sous-sol lors d'événements pluvieux. En raison des limitations techniques et afin d'éviter toute perturbation physique dans la subsurface, ce dispositif de mesure emploie une installation non-conventionnelle, où toutes les électrodes de courant sont placées au bord de la zone d'étude. Le dispositif le plus approprié pour suivre les variations verticales et latérales de la résistivité électrique à partir d'une installation permanente a été choisi à l'aide de modélisations numériques. Les résultats démontrent que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle et plus apte à détecter les variations latérales et verticales de la résistivité électrique, et cela malgré la configuration non-conventionnelle des électrodes. Pour tester l'efficacité du système proposé, des données de terrain ont été collectées sur un site d'étude expérimental. La technique de monitorage utilisée permet de suivre le processus d'infiltration 3D pendant des événements pluvieux. Une bonne corrélation est observée entre les résultats de modélisation numérique et les données de terrain, confirmant par ailleurs que le dispositif pôle-dipôle offre une meilleure résolution que le dispositif pôle-pôle. La nouvelle technique de monitorage 3D de résistivité électrique permet de caractériser les zones d'écoulement préférentiel et de caractériser le rôle de la lithologie et de la pédologie de manière quantitative dans les processus hydrologiques responsables d'écoulement de crue. ABSTRACT During the last years, electrical methods were often used for the investigation of subsurface structures. Electrical resistivity tomography (ERT) has been reported to be a useful non-invasive and spatially integrative prospecting technique. The ERT method provides significant improvements, with the developments of new inversion algorithms, and the increasing efficiency of data collection techniques. Multichannel technology and powerful computers allow collecting and processing resistivity data within few hours. Application domains are numerous and varied: geology and hydrogeology, civil engineering and geotechnics, archaeology and environmental studies. In particular, electrical methods are commonly used in hydrological studies of the vadose zone. The aim of this study was to develop a multichannel, automatic, non-invasive, reliable and inexpensive 3D monitoring system designed to follow electrical resistivity variations in soil during rainfall. Because of technical limitations and in order to not disturb the subsurface, the proposed measurement device uses a non-conventional electrode set-up, where all the current electrodes are located near the edges of the survey grid. Using numerical modelling, the most appropriate arrays were selected to detect vertical and lateral variations of the electrical resistivity in the framework of a permanent surveying installation system. The results show that a pole-dipole array has a better resolution than a pole-pole array and can successfully follow vertical and lateral resistivity variations despite the non-conventional electrode configuration used. Field data are then collected at a test site to assess the efficiency of the proposed monitoring technique. The system allows following the 3D infiltration processes during a rainfall event. A good correlation between the results of numerical modelling and field data results can be observed since the field pole-dipole data give a better resolution image than the pole-pole data. The new device and technique makes it possible to better characterize the zones of preferential flow and to quantify the role of lithology and pedology in flood- generating hydrological processes.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aquest article descriu els sensors enzimàtics i immunosensors electroquímics que s’han desenvolupat als nostres grups per a la detecció de la biotoxina marina àcid okadaic (OA), i discuteix la possibilitat d’integrar-los en programes de seguiment. Els sensors enzimàtics per a OA que es presenten es basen en la inhibició de la proteïna fosfatasa (PP2A) per aquesta toxina i la mesura electroquímica de l’activitat enzimàtica mitjançant l’ús de substrats enzimàtics apropiats, electroquímicament actius després de la seva desfosforació per l’enzim. Els immunosensors electroquímics descrits en aquest article es basen en un enzimoimmunoassaig sobre fase sòlida competitiu indirecte (ciELISA), amb fosfatasa alcalina (ALP) o peroxidasa (HRP) com a marcatges, i un sistema de reciclatge enzimàtic amb diaforasa (DI). Els biosensors presentats aquí s’han aplicat a l’anàlisi de dinoflagel·lats, musclos i ostres. Les validacions preliminars amb assaigs colorimètrics i LC-MS/MS han demostrat la possibilitat d’utilitzar les bioeines desenvolupades per al cribratge preliminar de biotoxines marines en mostres de camp o de cultiu, que ofereixen informació complementària a la cromatografia. En conclusió, tot i que encara cal optimitzar alguns paràmetres experimentals, la integració dels biosensors a programes de seguiment és viable i podria proporcionar avantatges respecte a altres tècniques analítiques pel que fa al temps d’anàlisi, la simplicitat, la selectivitat, la sensibilitat, el fet de poder ser d’un sol ús i l’efectivitat de cost. This article describes the electrochemical enzyme sensors and immunosensors that have been developed by our groups for the detection of marine biotoxin okadaic acid (OA), and discusses the possibility of integrating them into monitoring programmes. The enzyme sensors for OA reported herein are based on the inhibition of immobilised protein phosphatase 2A (PP2A) by this toxin and the electrochemical measurement of the enzyme activity through the use of appropriate enzyme substrates, which are electrochemically active after dephosphorylation by the enzyme. The electrochemical immunosensors described in this article are based on a competitive indirect Enzyme- Linked ImmunoSorbent Assay (ciELISA), using alkaline phosphatase (ALP) or horseradish peroxidase (HRP) as labels, and an enzymatic recycling system with diaphorase (DI). The biosensors presented herein have been applied to the analysis of dinoflagellates, mussels and oysters. Preliminary validations with colorimetric assays and LC-MS/MS have demonstrated the possibility of using the developed biotools for the preliminary screening of marine biotoxins in field or cultured samples, offering complementary information to chromatography. In conclusion, although optimisation of some experimental parameters is still required, the integration of biosensors into monitoring programmes is viable and may provide advantages over other analytical techniques in terms of analysis time, simplicity, selectivity, sensitivity, disposability of electrodes and cost effectiveness.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An active, solvent-free solid sampler was developed for the collection of 1,6-hexamethylene diisocyanate (HDI) aerosol and prepolymers. The sampler was made of a filter impregnated with 1-(2-methoxyphenyl)piperazine contained in a filter holder. Interferences with HDI were observed when a set of cellulose acetate filters and a polystyrene filter holder were used; a glass fiber filter and polypropylene filter cassette gave better results. The applicability of the sampling and analytical procedure was validated with a test chamber, constructed for the dynamic generation of HDI aerosol and prepolymers in commercial two-component spray paints (Desmodur(R) N75) used in car refinishing. The particle size distribution, temporal stability, and spatial uniformity of the simulated aerosol were established in order to test the sample. The monitoring of aerosol concentrations was conducted with the solid sampler paired to the reference impinger technique (impinger flasks contained 10 mL of 0.5 mg/mL 1-(2-methoxyphenyl)piperazine in toluene) under a controlled atmosphere in the test chamber. Analyses of derivatized HDI and prepolymers were carried out by using high-performance liquid chromatography and ultraviolet detection. The correlation between the solvent-free and the impinger techniques appeared fairly good (Y = 0.979X - 0.161; R = 0.978), when the tests were conducted in the range of 0.1 to 10 times the threshold limit value (TLV) for HDI monomer and up to 60-mu-g/m3 (3 U.K. TLVs) for total -N = C = O groups.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyzes the delegation of contracting capacity in a moral hazard environment with sequential production in a project which involves a principal and two agents. The agent in charge of the …nal production can obtain soft information about the other agent's effort choice by investing in monitoring. I investigate the circumstances under which it is optimal for the principal to use a centralized organization in which she designs the contracts with both agents or to use a decentralized organization in which she contracts only one agent, and delegates the power to contract the other agent. It is shown that in this setting a decentralized organization can be superior to a centralized organization. This is because the principal is better off under monitoring and the incentives for an agent to invest in monitoring can be higher in a decentralized organization. The circumstances under which this is true are related to the monitoring costs and the importance of each agent for production. The results explain the recent application of the design-build method in public procurement. Journal of Economic Literature Classi…cation Numbers: D23, D82, L14, L22. Keywords: Decentralization of Contracting, Monitoring, Moral Hazard.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The FIFA has implemented an important antidoping programme for the 2014 FIFA World Cup. AIM: To perform the analyses before and during the World Cup with biological monitoring of blood and urine samples. METHODS: All qualified players from the 32 teams participating in the World Cup were tested out-of-competition. During the World Cup, 2-8 players per match were tested. Over 1000 samples were collected in total and analysed in the WADA accredited Laboratory of Lausanne. RESULTS: The quality of the analyses was at the required level as described in the WADA technical documents. The urinary steroid profiles of the players were stable and consistent with previously published papers on football players. During the competition, amphetamine was detected in a sample collected on a player who had a therapeutic use exemption for attention deficit hyperactivity disorder. The blood passport data showed no significant difference in haemoglobin values between out-of-competition and postmatch samples. CONCLUSIONS: Logistical issues linked to biological samples collection, and the overseas shipment during the World Cup did not impair the quality of the analyses, especially when used as the biological passport of football players.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A l'heure actuelle, le monitoring de la problématique du cannabis en Suisse constitue un ensemble de travaux qui permettent le suivi de la situation au niveau national et qui sont mis en oeuvre par un consortium d'instituts. Ce monitoring comprend l'étude présentée dans ce rapport, l'étude sentinelle. Elle s'intéresse à l'évolution de la situation en matière de cannabis ainsi qu'à la gestion de cette situation au niveau local. Ainsi, les observations relevées par des professionnels de terrain dans différents domaines (santé/social, école/formation professionnelle, police/justice) et dans quatre cantons suisses (St Gall, Tessin, Vaud, Zurich), dits "sentinelle", sont récoltées et analysées annuellement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In 1995 the working group "Drug Monitoring" of the Swiss Society of Clinical Chemistry (SSCC) has already published a printed version of drug monographs, which are now newly compiled and presented in a standardised manner. The aim of these monographs is to give an overview on the most important informations that are necessary in order to request a drug analysis or is helpful to interpret the results. Therefore, the targeted audience are laboratory health professionals or the receivers of the reports. There is information provided on the indication for therapeutic drug monitoring, protein binding, metabolic pathways and enzymes involved, elimination half life time and elimination routes as well as information on therapeutic or toxic concentrations. Because preanalytical considerations are of particular importance for therapeutic drug monitoring, there is also information given at which time the determination of the drug concentration is reasonable and when steady-state concentrations are reached after changing the dose. Furthermore, the stability of the drug and its metabolite(s), respectively, after blood sampling is described. For readers with a specific interest, references to important publications are given. The number of the monographs will be continuously enlarged. The updated files are presented on the homepage of the SSCC (www.sscc.ch).