837 resultados para Vapor sample


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mercury is a toxic metal used in a variety of substances over the course history. One of its more dubious uses is in dental amalgam restorations. It is possible to measure very small concentrations of this metal in the urine of exposed subjects by the cold vapor atomic absorption technique. The present work features the validation as an essential tool to confirm the suitability of the analytical method chosen to accomplish such determination. An initial analysis will be carried out in order to evaluate the environmental and occupational levels of exposure to mercury in 39 members of the auxiliary dental staff at public consulting rooms in the city of Araguaína (TO).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, a TPR (Temperature Programmed Reduction) system is used as a powerful tool to monitor carbon nanotubes production during CVD (Chemical Vapour Deposition), The experiments were carried out using catalyst precursors based on Fe-Mo supported on Al2O3 and methane as carbon source. As methane reacts on the Fe metal surface, carbon is deposited and H2 is produced. TPR is very sensitive to the presence of H2 and affords information on the temperature where catalyst is active to form different forms of carbon, the reaction kinetics, the catalyst deactivation and carbon yields.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An UV-Ozone reactor was developed with an ignition tube extracted into HID mercury lamp used to irradiation on zinc oxide (ZnO) and fluorinated tin oxide (FTO) films for PLEDs devices. Different exposures times were used. In contact angle measurements revealed better results for ZnO and FTO by 15 and 5 min, respectively. In Diffuse Reflectance Infra-red Fourier Transformed (DRIFT) spectroscopy allowed the observation of water, hydrocarbon and carbon dioxide adsorbed on the untreated TCO surfaces. After the UV-Ozone treatment the contaminants were significantly reduced or eliminated and the PLEDs devices decreased threshold voltages in comparison with respectively untreated TCOs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of the present study was to validate a method for organic Hg determination in sediment. The procedure for organic Hg was adapted from literature, where the organomercurial compounds were extracted with dichloromethane in acid medium and subsequent destruction of organic compounds by bromine chloride. Total Hg was performed according to 3051A USEPA methodology. Mercury quantification for both methodologies was then performed by CVAAS. Methodology validation was verified by analyzing certified reference materials for total Hg and methylmercury. The uncertainties for both methodologies were calculated. The quantification limit of 3.3 µg kg-1 was found for organic Hg by CVAAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The catalytic performance of Ni/ZrO2 catalysts loaded with different lanthanum content for steam reforming of ethanol was investigated. Catalysts were characterized by BET surface area, X-ray diffraction, UV-vis spectroscopy, temperature programmed reduction, and X-ray absorption fine structure techniques. Results showed that lanthanum addition led to an increase in the degree of reduction of both NiO and nickel surface species interacting with the support, due to the higher dispersion effect. The best catalytic performance at 450 ºC was found for the Ni/12LZ catalyst, which exhibited an effluent gaseous mixture with the highest H2 yield.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of moisture content in the steam treatment and enzymatic hydrolysis of sugarcane bagasse was evaluated. Steam treatment was perfomed at 195-210 ºC for 4-8 min using cane bagasse with moisture contents in the range 16-100 wt% (dry basis). Increased moisture contents not only had a positive influence in recovery of main cane biomass components but also resulted in better substrates for enzymatic hydrolysis. As a result, drying is not required for optimal pretreatment and enzymatic hydrolysis of sugarcane bagasse, which can be processed into second generation ethanol immediately after crushing and hot water washing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this paper was to revive the accurate determination of the boiling point of organic compounds using the percolator technique developed in the 1960s. Although this method is simple, fast and efficient it is omitted from current textbooks. This method has several advantages over Siwoloboff such as high reproducibility and direct measurement of the boiling point of the sample obtained by observing the temperature of the vapor-liquid equilibrium. The experiments were performed in the organic chemistry laboratory but allow interdisciplinary integration with other disciplines of several academic areas.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A direct, extraction-free spectrophotometric method has been developed for the determination of acebutolol hydrochloride (ABH) in pharmaceutical preparations. The method is based on ion-pair complex formation between the drug and two acidic dyes (sulphonaphthalein) namely bromocresol green (BCG) and bromothymol blue (BTB). Conformity to Beer's law enabled the assay of the drug in the range of 0.5-13.8 µg mL-1 with BCG and 1.8-15.9 µg mL-1 with BTB. Compared with a reference method, the results obtained were of equal accuracy and precision. In addition, these methods were also found to be specific for the analysis of acebutolol hydrochloride in the presence of excipients, which are co-formulated in the drug.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human genome comprises roughly 20 000 protein coding genes. Proteins are the building material for cells and tissues, and proteins are functional compounds having an important role in many cellular responses, such as cell signalling. In multicellular organisms such as humans, cells need to communicate with each other in order to maintain a normal function of the tissues within the body. This complex signalling between and within cells is transferred by proteins and their post-translational modifications, one of the most important being phosphorylation. The work presented here concerns the development and use of tools for phosphorylation analysis. Mass spectrometers have become essential tools to study proteins and proteomes. In mass spectrometry oriented proteomics, proteins can be identified and their post-translational modifications can be studied. In this Ph.D. thesis the objectives were to improve the robustness of sample handling methods prior to mass spectrometry analysis for peptides and their phosphorylation status. The focus was to develop strategies that enable acquisition of more MS measurements per sample, higher quality MS spectra and simplified and rapid enrichment procedures for phosphopeptides. Furthermore, an objective was to apply these methods to characterize phosphorylation sites of phosphopeptides. In these studies a new MALDI matrix was developed which allowed more homogenous, intense and durable signals to be acquired when compared to traditional CHCA matrix. This new matrix along with other matrices was subsequently used to develop a new method that combines multiple spectra from different matrises from identical peptides. With this approach it was possible to identify more phosphopeptides than with conventional LC/ESI-MS/MS methods, and to use 5 times less sample. Also, phosphopeptide affinity MALDI target was prepared to capture and immobilise phosphopeptides from a standard peptide mixture while maintaining their spatial orientation. In addition a new protocol utilizing commercially available conductive glass slides was developed that enabled fast and sensitive phosphopeptide purification. This protocol was applied to characterize the in vivo phosphorylation of a signalling protein, NFATc1. Evidence for 12 phosphorylation sites were found, and many of those were found in multiply phosphorylated peptides

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this work was to develop a simple and rapid preparation method for patulin analysis in apple juice without previous clean-up. This method combined sonication and liquid extraction techniques and was used for determination of patulin in 37 commercial apple juices available on the market in the South of Brazil. The method performance characteristics were determined using a sample obtained in a local market fortified at five concentration levels of patulin and done in triplicates. The coefficient of variation for repeatability at the fortification level of 20.70µg.L-1 was 3.53 % and the recovery 94.63 %, respectively. The correlation coefficient was 0.9996 and agrees with the requirements for a linear analytical method value. The detection limit was 0.21µg.L-1 and the quantification limit 0.70 µg.L-1. Only three of the analyzed samples were upper the allowed level of 50.00 µg.L-1 recommended for the World Health Organization.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: 1 - Verify the prevalence of depressive symptoms in first to fourth-year medical students using the Beck Depression Inventory (BDI). 2 - Establish correlations between target factors and higher or lower BDI scores. 3 - Investigate the relationship between the prevalence of depressive symptoms and the demand for psychological care offered by the Centro Universitário Lusíada. METHOD: Cross-sectional study of 290 first to fourth-year medical students; implementation of the BDI, socio-demographic survey, and evaluation of satisfaction with progress. RESULTS: The study sample was 59% female and 41% male. Mean BDI was 6.3 (SD 5.8). Overall prevalence of depressive symptoms was 23.1%. The following associations were statistically significant (p<0.05): among students for whom the course failed to meet original expectations, who were dissatisfied with the course, or who came from the interior of the State (20.5%, 12.5%, and 24.4% of the total sample, respectively), for 40%, 36.1% and 36.4%, respectively, the BDI was consistent with some degree of depression. CONCLUSION: The study showed that there is higher prevalence of depressive symptoms in medical students than in the general population

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Utilizando-se como padrão as medidas lisimétricas de um gramado, avaliaram-se os resultados de estimativas de ETo obtidas com Dar_méd oriundos de 14 métodos para seu cálculo. Tais comparações permitiram separar os métodos de cálculo de Dar_méd em três grupos, ou seja: um grupo resultou sempre em superestimativa de ETo; em outro, a tendência foi de sempre subestimar, e no último a tendência foi de superestimar valores baixos (< 4,5 mm dia-1) e de subestimar valores altos de ETo. Não foram observadas diferenças significativas (teste t; p < 0,05) de ETo, em função dos métodos de Dar_méd ao utilizar a média horária da temperatura e/ou umidade relativa do ar em relação aos determinados com a média dos valores máximo e mínimo desses elementos. Dos métodos propostos pelo boletim FAO56, apenas o que utilizou a umidade relativa média para calcular a pressão parcial de vapor d'água (e a) apresentou estimativa satisfatória. As melhores estimativas de ETo foram obtidas com os métodos de Dar_méd, que utilizaram média da temperatura do ar na determinação da pressão de saturação (e s), e média da umidade relativa para ea. A utilização do déficit de pressão de saturação em um único horário (9 e 10 h local), como representativo para o Dar_méd, mostrou-se boa alternativa na estimativa da ETo, para as condições climáticas de Piracicaba - SP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This book is dedicated to celebrate the 60th birthday of Professor Rainer Huopalahti. Professor Rainer “Repe” Huopalahti has had, and in fact is still enjoying a distinguished career in the analysis of food and food related flavor compounds. One will find it hard to make any progress in this particular field without a valid and innovative sample handling technique and this is a field in which Professor Huopalahti has made great contributions. The title and the front cover of this book honors Professor Huopahti’s early steps in science. His PhD thesis which was published on 1985 is entitled “Composition and content of aroma compounds in the dill herb, Anethum graveolens L., affected by different factors”. At that time, the thesis introduced new technology being applied to sample handling and analysis of flavoring compounds of dill. Sample handling is an essential task that in just about every analysis. If one is working with minor compounds in a sample or trying to detect trace levels of the analytes, one of the aims of sample handling may be to increase the sensitivity of the analytical method. On the other hand, if one is working with a challenging matrix such as the kind found in biological samples, one of the aims is to increase the selectivity. However, quite often the aim is to increase both the selectivity and the sensitivity. This book provides good and representative examples about the necessity of valid sample handling and the role of the sample handling in the analytical method. The contributors of the book are leading Finnish scientists on the field of organic instrumental analytical chemistry. Some of them are also Repe’ s personal friends and former students from the University of Turku, Department of Biochemistry and Food Chemistry. Importantly, the authors all know Repe in one way or another and are well aware of his achievements on the field of analytical chemistry. The editorial team had a great time during the planning phase and during the “hard work editorial phase” of the book. For example, we came up with many ideas on how to publish the book. After many long discussions, we decided to have a limited edition as an “old school hard cover book” – and to acknowledge more modern ways of disseminating knowledge by publishing an internet version of the book on the webpages of the University of Turku. Downloading the book from the webpage for personal use is free of charge. We believe and hope that the book will be read with great interest by scientists working in the fascinating field of organic instrumental analytical chemistry. We decided to publish our book in English for two main reasons. First, we believe that in the near future, more and more teaching in Finnish Universities will be delivered in English. To facilitate this process and encourage students to develop good language skills, it was decided to be published the book in English. Secondly, we believe that the book will also interest scientists outside Finland – particularly in the other member states of the European Union. The editorial team thanks all the authors for their willingness to contribute to this book – and to adhere to the very strict schedule. We also want to thank the various individuals and enterprises who financially supported the book project. Without that support, it would not have been possible to publish the hardcover book.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The mechanical harvesting is an important stage in the production process of soybeans and, in this process; the loss of a significant number of grains is common. Despite the existence of mechanisms to monitor these losses, it is still essential to use sampling methods to quantify them. Assuming that the size of the sample area affects the reliability and variability between samples in quantifying losses, this paper aimed to analyze the variability and feasibility of using different sizes of sample area (1, 2 and 3 m²) in quantifying losses in the mechanical harvesting of soybeans. Were sampled 36 sites and the cutting losses, losses by other mechanisms of the combine and total losses were evaluated, as well as the water content in seeds, straw distribution and crop productivity. Data were subjected to statistical analysis (descriptive statistics and analysis of variance) and Statistical Control Process (SCP). The coefficients of variation were similar for the three frames available. Combine losses showed stable behavior, whereas cutting losses and total losses showed unstable behavior. The frame size did not affect the quantification and variability of losses in the mechanical harvesting of soybeans, thus a frame of 1 m² can be used for determining losses.