824 resultados para Ultrasound (US)
Resumo:
OBJECTIVE: To evaluate morphological and perfusion changes in liver metastases of neuroendocrine tumours by contrast-enhanced ultrasound (CEUS) after transarterial embolisation with bead block (TAE) or trans-arterial chemoembolisation with doxorubicin-eluting beads (DEB-TACE). METHODS: In this retrospective study, seven patients underwent TAE, and ten underwent DEB-TACE using beads of the same size. At 1 day before embolisation, 2 days, 1 month and 3 months after the procedure, a destruction-replenishment study using CEUS was performed with a microbubble-enhancing contrast material on a reference tumour. Relative blood flow (rBF) and relative blood volume (rBV) were obtained from the ratio of values obtained in the tumour and in adjacent liver parenchyma. Morphological parameters such as the tumour's major diameter and the viable tumour's major diameter were also measured. A parameter combining functional and morphological data, the tumour vitality index (TVI), was studied. The Wilcoxon rank-sum test and Fisher's test were used to compare treatment groups. RESULTS: At 3 months rBF, rBV and TVI were significantly lower (P = 0.005, P = 0.04 and P = 0.03) for the group with doxorubicin. No difference in morphological parameters was found throughout the follow-up. CONCLUSIONS: One parameter, TVI, could evaluate the morphological and functional response to treatments.
Resumo:
As an emerging alternative to DXA, there is a growing interest in the use of quantitative ultrasound (QUS) measurements for the non invasive assessment of fracture risk in the management of osteoporosis. While the potential of QUS in the management of osteoporosis have been highly recognized by the scientific community and granted by the majority of the international bone disease organizations, it becomes important to develop strategies how to use ultrasound clinically. Our paper is highlighting Swiss operational clinical propositions for 2 QUS devices sold in Switzerland, on how to use the QUS in the management of osteoporosis.
Resumo:
The plant immune system relies to a great extent on the highly regulated expression of hundreds of defense genes encoding antimicrobial proteins, such as defensins, and antiherbivore proteins, such as lectins. The expression of many of these genes is controlled by a family of mediators known as jasmonates; these cyclic oxygenated fatty acid derivatives are reminiscent of prostaglandins. The roles of jasmonates also extend to the control of reproductive development. How are these complex events regulated? Nearly 20 members of the jasmonate family have been characterized. Some, like jasmonic acid, exist in unmodified forms, whereas others are conjugated to other lipids or to hydrophobic amino acids. Why do so many chemically different forms of these mediators exist, and do individual jasmonates have unique signaling properties or are they made to facilitate transport within and between cells? Key features of the jasmonate signal pathway have been identified and include the specific activation of E3-type ubiquitin ligases thought to target as-yet-undescribed transcriptional repressors for modification or destruction. Several classes of transcription factor are known to function in the jasmonate pathway, and, in some cases, these proteins provide nodes that integrate this network with other important defensive and developmental pathways. Progress in jasmonate research is now rapid, but large gaps in our knowledge exist. Aimed to keep pace with progress, the ensemble of jasmonate Connections Maps at the Signal Transduction Knowledge Environment describe (i) the canonical signaling pathway, (ii) the Arabidopsis signaling pathway, and (iii) the biogenesis and structures of the jasmonates themselves.
Resumo:
We have identified the specific ultrasonographical (US) changes in Schistosoma japonicum infected patients with the serological changes in general liver function markers. The US examination with the following haematological and biochemical serum analysis was performed on 102 patients in Shistosomiasis Hospital, Leyte, Philippines. The US liver images were classified into 4 patterns according to the development of periportal fibrosis and the patterns of echogenic bands. Among various haematological and biochemical serum parameters of liver damage. The serum levels of total bile acid (TBA) and procollagen-III-peptide (P-III-P) correlated well with the development of hepatic fibrosis and the portal hypertension. These patients were subsequently treated with praziquantel (3 x 20 mg/kg), and improvement of the thickening of the portal vein wall and the dintensity of the echogenic band formation was detected 6 months after treatment. The significant US changes could not be detected in the patients with severe hepatic fibrosis caused in the long term infection. The results revealed that the US examination with the serum TBa level would provider a sensitive tool monitor the severity of the infection and also the improvement occured shortly after praziquantel treatment.
Resumo:
Quantitative ultrasound (QUS) appears to be developing into an acceptable, low-cost and readily-accessible alternative to dual X-ray absorptiometry (DXA) measurements of bone mineral density (BMD) in the detection and management of osteoporosis. Perhaps the major difficulty with their widespread use is that many different QUS devices exist that differ substantially from each other, in terms of the parameters they measure and the strength of empirical evidence supporting their use. But another problem is that virtually no data exist outside of Caucasian or Asian populations. In general, heel QUS appears to be most tested and most effective. Some, but not all heel QUS devices are effective assessing fracture risk in some, but not all populations, the evidence being strongest for Caucasian females > 55 years old, though some evidence exists for Asian females > 55 and for Caucasian and Asian males > 70. Certain devices may allow to estimate the likelihood of osteoporosis, but very limited evidence exists supporting QUS use during the initiation or monitoring of osteoporosis treatment. Likely, QUS is most effective when combined with an assessment of clinical risk factors (CRF); with DXA reserved for individuals who are not identified as either high or low risk using QUS and CRF. However, monitoring and maintenance of test and instrument accuracy, precision and reproducibility are essential if QUS devices are to be used in clinical practice; and further scientific research in non-Caucasian, non-Asian populations clearly is compulsory to validate this tool for more widespread use.
Resumo:
Meta-analysis of prospective studies shows that quantitative ultrasound of the heel using validated devices predicts risk of different types of fracture with similar performance across different devices and in elderly men and women. These predictions are independent of the risk estimates from hip DXA measures.Introduction Clinical utilisation of heel quantitative ultrasound (QUS) depends on its power to predict clinical fractures. This is particularly important in settings that have no access to DXA-derived bone density measurements. We aimed to assess the predictive power of heel QUS for fractures using a meta-analysis approach.Methods We conducted an inverse variance random effects meta-analysis of prospective studies with heel QUS measures at baseline and fracture outcomes in their follow-up. Relative risks (RR) per standard deviation (SD) of different QUS parameters (broadband ultrasound attenuation [BUA], speed of sound [SOS], stiffness index [SI], and quantitative ultrasound index [QUI]) for various fracture outcomes (hip, vertebral, any clinical, any osteoporotic and major osteoporotic fractures) were reported based on study questions.Results Twenty-one studies including 55,164 women and 13,742 men were included in the meta-analysis with a total follow-up of 279,124 person-years. All four QUS parameters were associated with risk of different fracture. For instance, RR of hip fracture for 1 SD decrease of BUA was 1.69 (95% CI 1.43-2.00), SOS was 1.96 (95% CI 1.64-2.34), SI was 2.26 (95%CI 1.71-2.99) and QUI was 1.99 (95% CI 1.49-2.67). There was marked heterogeneity among studies on hip and any clinical fractures but no evidence of publication bias amongst them. Validated devices from different manufacturers predicted fracture risks with similar performance (meta-regression p values > 0.05 for difference of devices). QUS measures predicted fracture with a similar performance in men and women. Meta-analysis of studies with QUS measures adjusted for hip BMD showed a significant and independent association with fracture risk (RR/SD for BUA = 1.34 [95%CI 1.22-1.49]).Conclusions This study confirms that heel QUS, using validated devices, predicts risk of different fracture outcomes in elderly men and women. Further research is needed for more widespread utilisation of the heel QUS in clinical settings across the world.
Resumo:
Ultrasound segmentation is a challenging problem due to the inherent speckle and some artifacts like shadows, attenuation and signal dropout. Existing methods need to include strong priors like shape priors or analytical intensity models to succeed in the segmentation. However, such priors tend to limit these methods to a specific target or imaging settings, and they are not always applicable to pathological cases. This work introduces a semi-supervised segmentation framework for ultrasound imaging that alleviates the limitation of fully automatic segmentation, that is, it is applicable to any kind of target and imaging settings. Our methodology uses a graph of image patches to represent the ultrasound image and user-assisted initialization with labels, which acts as soft priors. The segmentation problem is formulated as a continuous minimum cut problem and solved with an efficient optimization algorithm. We validate our segmentation framework on clinical ultrasound imaging (prostate, fetus, and tumors of the liver and eye). We obtain high similarity agreement with the ground truth provided by medical expert delineations in all applications (94% DICE values in average) and the proposed algorithm performs favorably with the literature.
Resumo:
Introduction: A standardized three-dimensional ultrasonographic (3DUS) protocol is described that allows fetal face reconstruction. Ability to identify cleft lip with 3DUS using this protocol was assessed by operators with minimal 3DUS experience. Material and Methods: 260 stored volumes of fetal face were analyzed using a standardized protocol by operators with different levels of competence in 3DUS. The outcomes studied were: (1) the performance of post-processing 3D face volumes for the detection of facial clefts; (2) the ability of a resident with minimal 3DUS experience to reconstruct the acquired facial volumes, and (3) the time needed to reconstruct each plane to allow proper diagnosis of a cleft. Results: The three orthogonal planes of the fetal face (axial, sagittal and coronal) were adequately reconstructed with similar performance when acquired by a maternal-fetal medicine specialist or by residents with minimal experience (72 vs. 76%, p = 0.629). The learning curve for manipulation of 3DUS volumes of the fetal face corresponds to 30 cases and is independent of the operator's level of experience. Discussion: The learning curve for the standardized protocol we describe is short, even for inexperienced sonographers. This technique might decrease the length of anatomy ultrasounds and improve the ability to visualize fetal face anomalies.
Resumo:
The functional architecture of the occipital cortex is being studied with increasing detail. Functional and structural MR based imaging are altering views about the organisation of the human visual system. Recent advances have ranged from comparative studies with non-human primates to predictive scanning. The latter multivariate technique describes with sub-voxel resolution patterns of activity that are characteristic of specific visual experiences. One can deduce what a subject experienced visually from the pattern of cortical activity recorded. The challenge for the future is to understand visual functions in terms of cerebral computations at a mesoscopic level of description and to relate this information to electrophysiology. The principal medical application of this new knowledge has focused to a large extent on plasticity and the capacity for functional reorganisation. Crossmodality visual-sensory interactions and cross-correlations between visual and other cerebral areas in the resting state are areas of considerable current interest. The lecture will review findings over the last two decades and reflect on possible roles for imaging studies in the future.
Resumo:
In recent years, management of abdominal pain in emergency care units (ECU) has undergone a radical change. Chronic work overload of ECU and increase in severity and complexity of cases required an optimal medical imaging method, such as ultrasound, to establish an accurate diagnosis as quickly as possible. A great variety of causes may cause acute abdominal pain and the role of sonography is to accurately distinguish between these aetiologies. For the application of sonography, perhaps more so than with other imaging methods, a perfect knowledge of sonographical characteristics and technical possibilities is essential to achieve an optimal answer. The purpose of this review is to present and discuss the sonographic characteristics of extra-digestive causes of acute abdominal pain such as splenic infarction, thoracic pathologies, urinary and gynaecologic diseases or retroperitoneal pathologies.