926 resultados para Ultrasonic Vocalizations
Resumo:
Thesis (M.S.)--University of Illinois.
Resumo:
"July 1974."
Resumo:
Senior thesis written for Oceanography 445
Resumo:
Background. The development of therapeutic interventions to prevent progressive valve damage is more likely to limit the progression of structural damage to the aortic valve with normal function (aortic sclerosis [ASC]) than clinically apparent aortic stenosis. Currently, the ability to appreciate the progression of ASC is compromised by the subjective and qualitative evaluation of sclerosis severity. Methods: We sought to reveal whether the intensity of ultrasonic backscatter could be used to quantify sclerosis severity in 26 patients with ASC and 23 healthy young adults. images of the aortic valve were obtained in the parasternal long-axis view and saved in raw data format. Six square-shaped 11 X 11 pixel regions of interest were placed on the anterior and posterior leaflets, and calibrated backscatter values were obtained by subtracting the regions of interest in the blood pool from the averaged backscatter values obtained from the leaflets. Results. Mean ultrasonic backscatter values for sclerotic valves exceeded the results in normal valve tissue (16.3 +/- 4.4 dB vs 9.8 +/- 3.3 dB, P < .0001). Backscatter values were greater (22.0 +/- 3.5 dB) in a group of 6 patients with aortic stenosis. Within the sclerosis group, the magnitude of backscatter was directly correlated (P < .05) with a subjective sclerosis score, and with transvalvular pressure gradient. mean reproducibility was 2.4 +/- 1.8 dB (SD) between observers, and 2.3 +/- 1.7 dB (SD) between examinations. Conclusion: Measurement of backscatter from the valve leaflets of patients with ASC may be a feasible means of following the progression and treatment response of aortic sclerosis.
Resumo:
We have used an animal model to test the reliability of a new portable continuous-wave Doppler ultrasonic cardiac output monitor, the USCOM. In six anesthetized dogs, cardiac output was measured with a high-precision transit time ultrasonic flowprobe placed on the ascending aorta. The dogs' cardiac output was increased with a dopamine infusion (0-15 mug (.) kg(-1) (.) min(-1)). Simultaneous flowprobe and USCOM cardiac output measurements were made. Up to 64 pairs of readings were collected from each dog. Data were compared by using the Bland and Altman plot method and Lin's concordance correlation coefficient. A total of 319 sets of paired readings were collected. The mean (+/-SD) cardiac output was 2.62 +/- 1.04 L/min, and readings ranged from 0.79 to 5.73 L/min. The mean bias between the 2 sets of readings was -0.01 L/min, with limits of agreement (95% confidence intervals) of -0.34 to 0.31 L/min. This represents a 13% error. In five of six dogs, there was a high degree of concordance, or agreement, between the 2 methods, with coefficients >0.9. The USCOM provided reliable measurements of cardiac output over a wide range of values. Clinical trials are needed to validate the device in humans.
Resumo:
The gelation profile of yoghurts from conventionally treated (85 degrees C/30 min) and UHT treated (143 degrees C/6s) milks at 16, 18, and 20% total solids was analyzed during fermentation for 4 hrs using the invasive Rapid Visco Analyzer (RVA) and the non-invasive ultrasonic spectroscope. The viscosity measured by the RVA and the ultrasonic velocity measured by the ultrasonic spectroscope exhibited similar sigmoid trends with respect to fermentation time. The ultrasonic spectroscope detected the onset of gelation of yoghurt milk earlier (by an average of 52 min) than did the RVA, indicating a higher sensitivity of ultrasonic spectroscopy. The delay of gelation time of UHT-treated yoghurt milk as compared to conventionally treated yoghurt milk was detected by both techniques. A non-significant ( P > 0.05) effect of solids content in the yoghurt milks on their gelation time was also observed by both instruments.
Resumo:
The in situ real time measurement of the regression rate of a melting interface (RRMI) is performed by the ultrasonic measurement system reported here. The RRMI is the rate at which a solid/liquid interface (SLI) moves along a metallic rod while burning in an oxygen-enriched atmosphere and is an important flatnmability indicator. The ultrasonic transducer and associated equipment used to drive the transducer and record the echo signal is described, along with the process that transforms the acquired signals into a RRMI value. Test rods of various metals and geometric shapes were burned at several test conditions in different test facilities. The RRMI results with quantified errors are presented and reviewed. The effect of reduced gravity on burning metals is important to space-applications and RRMI results obtained in a reduced gravity environment are also presented.
Resumo:
Smart structure sensors based on embedded fibre Bragg grating (FBG) arrays in aluminium alloy matrix by ultrasonic consolidation (UC) technique have been proposed and demonstrated successfully. The temperature, loading and bending responses of the embedded FBG arrays have been systematically characterized. The embedded FBGs exhibit an average temperature sensitivity of ~36 pm °C-1, which is three times higher than that of normal FBGs, a bending sensitivity of 0.73 nm/m-1 and a loading responsivity of ~0.1 nm kg-1 within the dynamic range from 0 kg to 3 kg. These initial experimental results clearly demonstrate that the UC produced metal matrix structures can be embedded with FBG sensor arrays to become smart structures with capabilities to monitor the structure operation and health conditions in applications.
Resumo:
The authors demonstrate that in-fibre Bragg gratings may be successfully used to measure megahertz acoustic fields if the grating length is sufficiently short and the optical fibre is appropriately desensitised. A noise-limited pressure resolution of 4.5 × 10 –3 atm vHz was found. The capability to simultaneously act as a temperature sensor is also demonstrated.
Resumo:
This thesis discusses the need for nondestructive testing and highlights some of the limitations in present day techniques. Special interest has been given to ultrasonic examination techniques and the problems encountered when they are applied to thick welded plates. Some suggestions are given using signal processing methods. Chapter 2 treats the need for nondestructive testing as seen in the light of economy and safety. A short review of present day techniques in nondestructive testing is also given. The special problems using ultrasonic techniques for welded structures is discussed in Chapter 3 with some examples of elastic wave propagation in welded steel. The limitations in applying sophisticated signal processing techniques to ultrasonic NDT~ mainly found in the transducers generating or receiving the ultrasound. Chapter 4 deals with the different transducers used. One of the difficulties with ultrasonic testing is the interpretation of the signals encountered. Similar problems might be found with SONAR/RADAR techniques and Chapter 5 draws some analogies between SONAR/RADAR and ultrasonic nondestructive testing. This chapter also includes a discussion on some on the techniques used in signal processing in general. A special signal processing technique found useful is cross-correlation detection and this technique is treated in Chapter 6. Electronic digital compute.rs have made signal processing techniques easier to implement -Chapter 7 discusses the use of digital computers in ultrasonic NDT. Experimental equipment used to test cross-correlation detection of ultrasonic signals is described in Chapter 8. Chapter 9 summarises the conclusions drawn during this investigation.
An ultrasonic instrumentation system for the study of vapour bubble formation and collapse in sodium