951 resultados para TRACE AMOUNTS


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Major, minor and trace elemental contents in northeast China soybeans were determined by using inductively, coupled plasma atomic emission spectrometry (ICP-AES). Three different sample digestion methods including two wet digestions, HNO3-HClO4 and HNO3-H2SO4 and a dry ash method were compared. Owing to the high oil content in soybeans, long time is needed and access acid should be added, with mixed acid digestion methods, which may result in higher sample blank. Therefore, the dry ask method would be more proper for the pre-treatment of soybean samples. Potassium and phosphorus are major elements in soybeans, so the effect of potassium and phosphorus on the other elements was investigated. Results showed that the potassium and phosphorus did not affect the determination. of other trace elements. There are not significant differences in trace elemental contents for the eleven northeast China soybeans.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new chemiluminescence(CL) system for the determination of ascorbic acid has been established. By the fast reduction reaction between chromium(VI) and ascorbic acid, chromium(M was generated to react with luminol and hydrogen peroxide in alkaline aqueous solution and hydrogen peroxide to produce CL. The CL emission intensity was correlated with ascorbic acid concentration in the range 8.0 x 10(-9) to 1.6 x 10(-4) mol/L, and the detection limit was 8.0 x 10(-9) mol/L ascorbic acid. The relative standard deviation (n = 11) for 1.0 x 10(-6) mol/L ascorbic acid is 0.9%. The method has been applied to the determination of ascorbic acid in vitamin C tablets with satisfactory results.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method was developed for the determination of trace and ultratrace amounts of REE. Cd. In. Tl. Th. Nb, Ta. Zr and Hf in soils and sediments. With NaOH-Na2O2 as the flux. Ti(OH)(4)-Fe(OH)(3) co-precipitation as the preconcentration technique and inductively coupled plasma mass spectrometry (ICP-MS) for measurement, the whole procedure was concise and suitable for batch analysis of multi-element solutions. An investigation was carried out of the Ti(OH)(4)-Fe(OH)(3) co-precipitation system, and the results obtained showed that the natural situation of Ti tightly coexisting with Nb. Ta, Zr and Hf in geological samples plays a very important role in the complete co-precipitation of the four elements. The accuracy of this procedure was established using six Chinese soil and sediment certified reference materials (GSS and GSD). and the relative errors between the found and certified values were mostly below 10%.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Using the Bridgeman-Stockbarger method, the KMgF3:EU2+ single crystal was grown. The color centers in unirradiated KMgF3:Eu crystal were studied. By thermal annealing, we confirmed the 422-nm emission resulted from color centers and oxygen centers, and we proved the energy transfer from EU2+ to color centers. From spectra, the relative oxygen content in crystal was calculated, and the relationships of oxygen displacing fluorine were studied.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The effect of the amount of the catalyst FeCl3, used during the direct oxidation polymerization, on the structure and properties of the obtained poly(3-dodecylthiophene) (P3DDT) was investigated in this paper. Such measurements as gel permeation chromatography (GPC), nuclear magnetic resonance (NMR) spectroscopy, thermal analysis, X-ray diffraction, infrared spectroscopy (FTIR) and ultraviolet-visible (W-vis) spectroscopy were applied. It is found that a suitable addition of FeCl3 can contribute to generate a P3DDT with greater percentage of head-to-tail head-to-tail (HT-HT) linkages, which are generally favored. The reduction of the other linkage defects helps to lengthen conjugation length, thus leading to more orderly chain packing. (C) 2000 Elsevier Science S.A. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Inductively coupled plasma mass spectrometry (ICP-MS),a highly sensitive inorgnic analytic technique,fits to determine ultra-nace rare-earth elements in human plasma. Under the optimized conditions detection limits for 15 rare-earth elements are in the range of 0.7 (for Eu)-5.4 (for Gd) ng.L-1. Indium as an internal standard element is used to compensate for matrix suppression effect and sensitivity drift. Three kinds of preparation methods, diluted with 1% HNO3, digested with HNO3-H2O2 and with HNO3-HClO4, are checked and compared,and the former is the simplest way to be measured. The samples diluted with 1% HNO3, stored in 4 degrees C, are very steady for 16 days. With the method, 11 healthy plasma samples in Changchun area of China are analysed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid linear analysis (HLA) was applied to resolution of overlapping spectra of Fe3+-salicylfluorone and Al3+-salicylfluorone complexes and simultaneous spectrophotometric determination of Fe3+ and Al3+. The absorbance matrix of 7 standard mixtures at 41 measuring points ranged from the wavelength of 550 nm to 630 nm was used for calibration. To avoid the effect of interaction between the two components on the determination, the column vector of K matrix obtained from the standard mixtures with least squares was used as the pure spectrum of component. The recoveries of the two elements for the analysis of the synthetic samples were 93.3% similar to 107.5% in the range of the concentration ratio of Fe3+:Al3+ = 10:1 to 1:8. Comparing with the partial least squares (PIS) model, the HLA method was simple, accuracy and precise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An experimental setup and the procedure for the laser resonant ionization mass spectrometry (RIMS) have been described. Both an optical spectrum and a mass spectum have been shown. The detection limit that can be reached by using this procedure has been estimated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The strong chelating ability of mercaptoacetic acid for certain metal ions is exploited for a new; kind of voltammetric sensor. Specifically, a glassy carbon electrode (GCE) surface was covalently covered br; mercaptoacetic acid. The preparation of mercap

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A method of analysis of high purity yttrium oxide with ICP-AES was described with emphasis on the study of Y_2O_3 matrix effects. The results showed that the line intensities of ana]ytes decreased with the increase of Y_2O_3 concentration in solution because of following factors. (1) The presence of matrix resulted in the decrease of the amount of analytes reaching ICP. (2) Matrix Y_2O_3 entering the plasma decreased the excitation temperature of the plasma and depressed the ionization of analytes in the pl...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hydrothermal fluid containing abundant matter erupts from seafloor, meets ambient cold seawater and forms chimneys. So the main matter origins of chimneys are seawater and matter which are taken by hydrothermal fluid from deep reservoir. However, because of seawater's little contribution to the forming of chimneys, it is usually covered by the abundant matter which is taken by hydrothermal fluid. Therefore, chimneys formed in ordinary deep seawater hydrothermal activity, containing complex elements, cannot be used to study the seawater's contribution to their formation. While the native sulfur chimneys, formed by hydrothermal activity near the sea area off Kueishantao, are single sulfur composition (over 99%), and within chimneys distinct layers are seen. Different layers were sampled for trace element determination, with Inductively Coupled Plasma Mass Spectrometry (ICP-MS). By analyzing the data, we consider C-layer (secondary inner-layer) as the framework layer of the chimney which formed early (Fig. 4), and its trace elements derive from hydrothermal fluid. While the trace elements within A, B, D layers have undergone later alteration. A, B layers are affected by seawater and D layer by hydrothermal fluid. The increase of trace elements of A and B layers was calculated using C layer as background. Based on the known typical volume of chimneys of the near sea area off Kueishantao, we calculated the volume of seawater that contributed trace element to chimneys formation to be about 6.37 x 10(4) L. This simple quantified estimate may help us better understand the seafloor hydrothermal activity and chimneys.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Peridotites from the southern Mariana forearc were sampled on the landward trench slope of the Izu-Bonin-Mariana (IBM) subduction zone by dredging. These mantle wedge peridotites underwent hydration by fluid derived from a dehydrated descending slab, and later interacted with seawater after emplacement at or near the seafloor. This study investigates how these two different rock-fluid interaction processes influenced trace element distribution in the southern Mariana forearc peridotites. We measured trace element concentrations of peridotites from the southern Mariana forearc. The southern Mariana forearc peridotites are characterized by a distinct seawater-like REE pattern with an obvious negative Ce anomaly, and La shows good correlation with other REEs (except Ce). In addition, there is a great enrichment of U, Pb, Sr and Li elements, which show a distinct positive anomaly relative to adjacent elements in the multi-element diagram. For the seawater-like REE pattern, we infer that REEs are mainly influenced by seawater during peridotite-seawater interactions after their emplacement at or near the seafloor, by serpentinization or by marine weathering. Furthermore, the anomalous behavior of Ce, compared with other rare earth elements in these samples, may indicate that they have undergone reactions involving Ce (IV) when the peridotites interacted with seawater. Positive U, Pb, Sr and Li anomalies are inferred to be related to seawater and/or fluids released during dehydration of the subducting slab.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The whole rock K-Ar ages of basalts from the South China Sea basin vary from 3.8 to 7.9 Ma, which suggest that intra-plate volcanism after the cessation of spreading of the South China Sea (SCS) is comparable to that in adjacent regions around the SCS, i.e., Leiqiong Peninsula, northern margin of the SCS, Indochina block, and so on. Based on detailed petrographic studies, we selected many fresh basaltic rocks and measured their major element, trace element, and Sr-Nd-Pb isotope compositions. Geochemical characteristics of major element and trace element show that these basaltic rocks belong to alkali basalt magma series, and are similar to OIB-type basalt. The extent of partial melting of mantle rock in source region is very low, and magma may experience crystallization differentiation and cumulation during the ascent to or storing in the high-level magma chamber. Sr-Nd-Pb isotopic data of these basaltic rocks imply an inhomogeneous mantle below the South China Sea. The nature of magma origin has a two end-member mixing model, one is EM2 (Enriched Mantle 2) which may be originated from mantle plume, the other is DMM (Depleted MORB Mantle). Pb isotopic characteristics show the Dupal anomaly in the South China Sea, and combined with newly found Dupal anomaly at Gakkel ridge in Arctic Ocean, this implies that Dupal anomaly is not only limited to South Hemisphere. In variation diagrams among Sr, Nd and Pb, the origin nature of mantle below the SCS is similar to those below Leiqiong peninsula, northern margin of the SCS and Indochina peninsula, and is different from those below north and northeast China. This study provides geochemical constraints on Hainan mantle plume.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An off-line chelation system combined with ICP-MS technique was developed for the quantitative determination of trace elements in seawater, namely V, Co, Ni, Cu, Zn, Mo, Cd, Pb, U and rare earth elements(REEs). The system was built based on an ion chromatography equipped with MetPac((R)) CC-I chelation columns which had a strong selective chelation to these target elements within a pH range 5.2-5.6. Acidified seawater samples and NH4Ac(2 mol/L) were blended to meet suitable pH before being injected into the chelation column, thus target elements were retained while alkali and alkaline metals were excluded. Then chelated elements were eluted by HNO3 (1 mol/L) and samples were collected for ICP-MS analysis. Varying the ratio of input( gen. 200 mL) to output( gen. 5 mL), the target elements which were concentrated as 40 times as their concentrations were far beyond instrumental quantification limits. At last, a certificated seawater CASS-4 was introduced and our detected values were in good agreement with those certified values.